Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transmission x-ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Effects on LDEF exposed copper film and bulk

Two forms of copper were exposed to the Long Duration Exposure Facility (LDEF) Mission 1 environment: a copper film, initially 74.2 plus or minus 1.1 nm thick sputter coated on a fused silica flat and a bulk piece of oxygen-free, high conductivity (OFHC) copper. The optical density of the copper film changed from 1.33 to 0.70 where exposed, and the film thickness increased to 106.7 plus or minus 0.5 nm where exposed. The exposed area appears purple by reflection and green by transmission for the thin film and maroon color for the bulk copper piece. The exposed areas increased in thickness, but only increase in the thickness of the thin film sample could be readily measured. The increase in film thickness is consistent with the density changes occurring during conversion of copper to an oxide. However, we have not been able to confirm appreciable conversion to an oxide by x-ray diffraction studies. We have not yet subjected the sample to e-beams or more abusive investigations out of concern that the film might be modified.

Peters, Palmer N.↗

A focusing collector for long wavelength X-ray astronomy.

Rocket studies of the low-energy X-ray sky conducted so far suffer from serious experimental problems. Therefore, an apparatus was design ed to overcome the outstanding experimental problems. The instrument developed was successfully flown in an Aerobee-170 rocket. The new device utilizes a grazing incidence paraboloid as an energy concentrator and low-pass filter. The effective bandpass of the instrument from 100 to 280 eV is determined by the combination of the counter window transmission and the mirror reflectivity.

Yentis, D. J.↗

X-ray satellite

An overview of the second quarter 1985 development of the X-ray satellite project is presented. It is shown that the project is proceeding according to plan and that the projected launch date of September 9, 1987 is on schedule. An overview of the work completed and underway on the systems, subsystems, payload, assembly, ground equipment and interfaces is presented. Problem areas shown include cost increases in the area of focal instrumentation, the star sensor light scattering requirements, and postponements in the data transmission subsystems.

Source record↗

Research relative to high resolution camera on the advanced X-ray astrophysics facility

The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the x-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft x-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15 ergs sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.

Source record↗

The Advanced X-ray Astrophysics Facility high resolution camera

The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the X-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft X-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15th ergs/sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.

Murray, Stephen S.↗

Laboratory Investigation of the Growth and Crystal Structure of Nitric Acid Hydrates by Transmission Electron Microscopy (TEM)

A great deal of recent laboratory work has focussed on the characterization of the nitric acid hydrates, thought to be present in type I Polar Stratospheric Clouds (PSCs). Phase relationships and vapor pressure measurements (1-3) and infrared characterizations (4-5) have been made. However, the observed properties of crystalline solids (composition, melting point, vapor pressure, surface reactivity, thermodynamic stability, extent of solid solution with other components, etc.) are controlled by their crystal structure. The only means of unequivocal structural identification for crystalline solids is diffraction (using electrons, X-rays, neutrons, etc.). Other observed properties of crystalline solids, such as their infrared spectra, their vapor pressure as a function of temperature, etc. yield only indirect information about what phases are present, their relative proportions, or whether they are crystalline or amorphous.

Blake, David F.↗

The interaction of atomic oxygen with copper: An XPS, AES, XRD, optical transmission, and stylus profilometry study

The University of Alabama in Huntsville (UAH) experiment A-0114 was designed to study the reaction of material surfaces with low earth orbits (LEO) atmospheric oxygen. The experiment contained 128 one-inch circular samples; metals, polymers, carbons, and semiconductors. Half of these samples were exposed on the front of the Long Duration Exposure Facility (LDEF) and remaining on the rear. Among metal samples, copper has shown some interesting new results. There were two forms of copper samples: a thin film sputter-coated on fused silica and a solid piece of OFHC copper. They were characterized by x-ray and Auger electron spectroscopies, x-ray diffraction, and high resolution profilometry. Cu 2p core level spectra were used to demonstrate the presence of Cu2O and CuO and to determine the oxidation states.

Raikar, Ganesh N.↗

Observation of hard X-rays from the Crab pulsar and A0535+26

The Crab pulsar PSR0531+21 was observed in a balloon flight from the Xianghe Balloon Station (China). Data were obtained in the range 20 to 200 keV with a poswish hard X-ray telescope which comprised a 150 sq cm primary crystal of 5 mm thick CsI(T1) which actively shielded the lower 2 pi steradians by a 5 cm thick NaI(T1) crystal. The scintillation pulses originating in CsI and NaI crystals are distinguished by pulse shape discrimination. The telescope has a field of view of approximately 4 deg H psi H pi determined by graded shield and collimator. The effective geometric area of the detector is 116 sq cm. It is noted that when folding a data flow on a long period interference from the data acquisition, transmission and recording system considerably affect the result.

Wu, M.↗

Coded aperture imaging with uniformly redundant arrays

The paper discusses uniformly redundant arrays (URA) as applied to coded aperture imaging. The URA system offers the high-transmission characteristics of random arrays as well as a flat sidelobe advantage. The high-transmission yields the imaging of very low-intensity sources and the flat sidelobes provide the suppression of inherent noise which obscures low-contrast sources. Simulations have shown that the URA with shot and background noise produces a better reconstructed object than random arrays without shot or background noise. The URA also offers an arrangement which involves a mosaic of basic URA patterns forming a circular correlation of the object on the picture plane. Thus the information needed to reconstruct the object is contained in an area equal to that of the basic aperture pattern. This smaller required detector is important in applications including X-ray astronomy.

Fenimore, E. E.↗

SPIKE: Application for ASTRO-D mission planning

SPIKE is a mission planning software system developed by a team of programmers at the STScI for use with the Hubble Space Telescope (HST). SPIKE has been developed for the purpose of automating observatory scheduling to increase the effective utilization and ultimately, scientific return from orbiting telescopes. High-level scheduling strategies using both rule-based and neural network approaches have been incorporated. Graphical displays of activities, constraints, and schedules are an important feature of the system. Although SPIKE was originally developed for the HST, it can be used for other astronomy missions including ground-based observatories. One of the missions that has decided to use SPIKE is ASTRO-D, a Japanese X-ray satellite for which the U.S. is providing a part of the scientific payload. Scheduled to fly in Feb. 1993, its four telescopes will focus X-rays over a wide energy range onto CCD's and imaging gas proportional counters. ASTRO-D will be the first X-ray imaging mission operating over the 0.5-12 keV band with high energy resolution. This combination of capabilities will enable a varied and exciting program of astronomical research to be carried out. ASTRO-D is expected to observe 5 to 20 objects per day and a total of several thousands per year. This requires the implementation of an efficient planning and scheduling system which SPIKE can provide. Although the version of SPIKE that will be used for ASTRO-D mission is almost identical to that used for the HST, there are a few differences. For example, ASTRO-D will use two ground stations for data downlinks, instead of the TDRSS system for data transmission. As a consequence ASTRO-D is constrained by limited on-board data storage capacity to schedule high data-rate observations during periods of frequent high bit rate observations accordingly. We will demonstrate the ASTRO-D version of SPIKE to show what SPIKE can provide and how efficiently it creates an observational schedule.

Isobe, T.↗

Determination of plasma temperatures and luminosities using multiple extreme-ultraviolet and X-ray filters

We carefully examine the techniques used to infer temperatures of stellar coronal plasmas from the count rates of several broadband instruments in the X-ray and extreme-ultraviolet spectral ranges. In particular, we determine to what extent temperatures can be constrained and the corresponding uncertainties in the luminosities and emission measures lowered by fitting simultaneously count rates from the Einstein imaging proportional counter (IPC), the ROSAT Position Sensitive Proportional Counter (PSPC), the ROSAT Wide Field Camera (WFC) (both filters), and the EXOSAT Low Energy Telescope (LET) with the 3-Lex filter. We use published plasma emissivities with solar photospheric abundances. Since it has been found that single-temperature plasmas do not fit IPC data well, we assume a two-temperature plasma model. We find that, even with count rates from all of the above filters and overly optimistic error estimates, it is still not possible to determine a unique two-temperature solution. However, since the use of count rates from many filters can reduce substantially the number of possible solutions, temperature solutions determined by other means can be tested. We carry out such an analysis on a set of 18 nearby late-type stars to determine possible two-temperature solutions using multifilter photometry, and we compare these results with the temperature solutions derived by Schmitt et al. (1990) using IPC spectral data. In general, the two-temperature fits derived from the IPC spectral data are inconsistent with our results, with our data implying that, for many stars, the two temperatures derived by the IPC may be too low by about a factor of 2. The EXOSAT transmission grating Spectrometer (TGS) spectra of capella and sigma(exp 2) CrB support this conclusion. For Procyon and 70 Oph, though, the presence of a temperature component cooler than a million degress (not detected by the IPC) is deduced. While our analysis suggests the existence of more than one temperature in the coronae of late-type stars, in many instances our WFC data appear to be inconsistent with the presence of significant emission measure over a broad temperature distribution. This, together with the success of two-temperature plasmas in fitting IPC and TGS data, implies that for many stars, the coronal emission measure distribution may in fact be dominated by two distinct temperature regimes.

Wood, Brian E.↗

Imaging slitless spectrometer for X-ray astronomy

Imaging slitless spectrometer, a combination of an X ray transmission /or reflection/ grating and image-forming X ray telescope, is capable of obtaining simultaneous spatial and spectral information about celestial X ray sources.

Gursky, H.↗

Microscopic observations of X-ray and gamma-ray induced decomposition of ammonium perchlorate crystals

The X-ray and gamma-ray induced decomposition of ammonium perchlorate was studied by optical, transmission, and scanning electron microscopy. This material is a commonly used oxidizer in solid propellents which could be employed in deep-space probes, and where they will be subjected to a variety of radiations for as long as ten years. In some respects the radiation-induced damage closely resembles the effects produced by thermal decomposition, but in other respects the results differ markedly. Similar radiation and thermal effects include the following: (1) irregular or ill-defined circular etch pits are formed in both cases; (2) approximately the same size pits are produced; (3) the pit density is similar; (4) the c face is considerably more reactive than the m face; and (5) most importantly, many of the etch pits are aligned in crystallographic directions which are the same for thermal or radiolytic decomposition. Thus, dislocations play an important role in the radiolytic decomposition process.

Herley, P. J.↗

Large-aperture high-resolution X-ray collimator for the Solar Maximum Mission

A description is presented of a flight-qualified large-aperture 12 x 12-arcsec angular resolution multigrid X-ray collimator developed for the Solar Maximum Mission (SMM) flat crystal spectrometer. This collimator, designed for the 1.4-22.4-A wavelength range, utilizes an optical bench/metering structure to align and support prealigned grid subassemblies. The optical bench is a lightweight, rigid, and stable aluminum honeycomb structure. The grids are of a compound and bimetallic design, having 63.5-micron square holes on an 88.9-micron spacing in 8-micron thick gold, which is in turn supported by a 76-micron thick Invar grid having 600-micron square holes on a 739-micron spacing. The small apertures in the gold provide the 12-arcsec collimation with the Invar grids providing wide angle off-axis blocking out to an approximately 35 arcmin view angle. The collimator has seven individual channels, four of a 5.1- x 10-cm area and three of a 1.3- x 10-cm area. Laboratory measurements gave an average angular resolution of 12.5 arcsec FWHM with 0.259 transmission for the large-area channels and 12.0 arcsec and 0.200 transmission for the small-area channels. A thermal filter composed of two layers of approximately 1000-A thick aluminum prevents solar heating of the front collimator grids by absorbing longer wavelength radiation while passing most of the X radiation in the band of interest.

Nobles, R. A.↗

Optical fibers and components experiment (A0138-7)

Fiber optics permanent damages induced by ionizing radiation after a long exposure in space and after laboratory tests were examined. Irradiation tests performed with radioactive sources (Sr90 - Y90) were validataed, computer coses used for the fluence and dose profile were verified. The performance of fiber optics waveguides in a low altitude orbit, and the origin of transmission losses in the material were dtermined. High sensitivity to ionizing radiations, however, may be a restriction for optic fiber use on satellites. Irradiation tests on these components using neutrons, gamma rays, and X-rays are carried out. Radiation damage on opticao materials, however, is strongly linked to the test conditions.

Bourrieau, J.↗

High-resolution imaging gamma-ray spectroscopy with externally segmented germanium detectors

Externally segmented germanium detectors promise a breakthrough in gamma-ray imaging capabilities while retaining the superb energy resolution of germanium spectrometers. An angular resolution of 0.2 deg becomes practical by combining position-sensitive germanium detectors having a segment thickness of a few millimeters with a one-dimensional coded aperture located about a meter from the detectors. Correspondingly higher angular resolutions are possible with larger separations between the detectors and the coded aperture. Two-dimensional images can be obtained by rotating the instrument. Although the basic concept is similar to optical or X-ray coded-aperture imaging techniques, several complicating effects arise because of the penetrating nature of gamma rays. The complications include partial transmission through the coded aperture elements, Compton scattering in the germanium detectors, and high background count rates. Extensive electron-photon Monte Carlo modeling of a realistic detector/coded-aperture/collimator system has been performed. Results show that these complicating effects can be characterized and accounted for with no significant loss in instrument sensitivity.

Callas, J. L.↗

Organometallic chemical vapor deposition and characterization of ZnGe(1-x)Si(x)P2-Ge alloys on GaP substrates

The epitaxial growth of ZnGe(1-x)Si(x)P2-Ge alloys on GaP substrates by open tube organometallic chemical vapor deposition (OMCVD) is reported. The chemical composition of the alloys characterized by energy dispersive X-ray spectroscopy shows that alloys with x up to 0.13 can be deposited on (001) GaP. Epitaxial growth with mirror smooth surface morphology was achieved for x less than or equal to 0.05. Transmission electron microscopy (TEM) micrographs of these alloys show specular epitaxy and the absence of microstructural defects indicating a defect density of less than 10(exp 7) cm(sup -2). Selected area electron diffraction pattern of the alloy shows that the epitaxial layer crystallizes in the chalcopyrite structure with relatively weak superlattice reflections indicating certain degree of randomness in the cation sublattice. Hall measurements show that the alloys are p-type, like the unalloyed films; the carrier concentration, however, dropped about 10 times from 2 x 10(exp 18) to 2 x 10(exp 17) cm(sup -3). Absorption measurements indicate that the band tailing in the absorption spectra of the alloy was shifted about 0.04 eV towards shorter wavelength as compared to the unalloyed material. Diodes fabricated from the n(+)-GaP/p-ZnSiP2-ZnGeP2-Ge heterostructure at x = 0.05 have a reverse break-down voltage of -10.8 V and a reverse saturation current density of approximately 6 x 10(exp -8) A/sq cm.

Xing, G. C.↗