A rotating, noncapillary heat pipe

Hollow rotating shaft operates like a heat pipe, with a small, sealed-in inventory of fluid that transfers heat by vaporizing at the hot end and condensing at the cold end. This heat pipe utilizes large centrifugal forces for pumping the condensate, and rotation to enforce liquid-vapor separation.

Gray, V. H.↗

Heat Treatments of ZnSe Starting Materials for Physical Vapor Transport

The effect of different heat treatments on stoichiometry and residual gas pressure in ZnSe physical vapor transport system was investigated. The dependence of the amount and composition of the residual gas on various heat treatment procedures is reported. Heat treatment of ZnSe starting materials by baking under the condition of dynamic vacuum to adjust its stoichiometry was performed and the effectiveness of the treatment was confirmed by the measurements of the partial pressure of Se2, P(sub Se2), in equilibrium with the heat treated samples. Optimum heat treatment procedures on the ZnSe starting material for the physical vapor transport process are discussed and verified experimentally.

Su, Ching-Hua↗

Heat Treatments of ZnSe Starting Materials for Physical Vapor Transport

The effect of different heat treatments on stoichiometry and residual gas pressure in ZnSe physical vapor transport system was investigated. The dependence of the amount and composition of the residual gas on various heat treatment procedures is reported. Heat treatment of ZnSe starting materials by baking under the condition of dynamic vacuum to adjust its stoichiometry was performed and the effectiveness of the treatment was confirmed by the measurements of the partial pressure of Se2, P(sub Se2), in equilibrium with the heat treated samples. Optimum heat treatment procedures on the ZnSe starting material for the physical vapor transport process are discussed and verified experimentally.

Su, Ching-Hua↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-stage heat pump with two-phase injection for cold climate applications implementing natural refrigerants

Heat pump adoption in cold climates is limited by various technical challenges, including heat capacity degradation, compressor deterioration, and frost accumulation on the outdoor heat exchanger. Furthermore, wide-spread adoption of heat pumps with high global warming potential presents a possible environmental concern. Thus, we present a heat pump concept termed the “saturation cycle,” which uses numerous compression stages to improve energy efficiency and injects two-phase refrigerant between compression stages to dramatically reduce compressor discharge temperatures. Given the growing interest in heat pumps, there is a need for a straightforward framework for parametric evaluation of natural refrigerants in high-efficiency heat pump cycle architectures, like the saturation cycle, in adverse climates. This work develops a thermodynamic modeling framework and focuses on the application of natural refrigerants to explore the performance trends at extremely cold climates down to −25 °C. This study shows that a two-stage saturation cycle and four-stage saturation cycle can reduce the compressor discharge superheating by up to 51–57 % or 73–80 %, respectively, depending on the refrigerant. Furthermore, at −25 °C, a two-stage R-290 saturation cycle heat pump theoretically can use 25 % less power than a single-stage heat pump or can provide up to 59 % more heating capacity when using the same compressor power as the baseline single-stage heat pump. The exergetic parametric analyses show that two-phase refrigerant injection fundamentally improves the thermodynamic performance of the heat pump, reducing overall exergy destruction by 10 % compared to a vapor-injection heat pump, compared at −25 °C. Thus, the saturation cycle is a promising heat pump cycle architecture for cold climate applications due to its superior energy savings (or capacity improvement) and substantial de-superheating capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical investigation of liquid wall ablation in inertial fusion energy chambers

This paper presents a novel approach for modeling liquid wall ablation in liquid wall-protected inertial fusion energy (IFE) chambers. These systems are promising candidates for the implementation of fusion technology, yet significant gaps remain in understanding the underlying physical processes and their implications for design. Following target ignition, a portion of the fusion energy is released as x-rays, which deposit their energy into an array of liquid jets, leading to partial vaporization. Accurately modeling this heat deposition and vaporization process remains challenging due to the complex geometries typical of (pre-conceptual) IFE chamber designs. Furthermore, the subsequent expansion of vaporized material into the chamber’s vacuum environment poses difficulties for conventional CFD methods based on continuum assumptions, which can lead to significant inaccuracies. To address some aspects of these challenges, this work introduces a ray-tracing-based methodology to map the spatial distribution of ablated material in liquid wall-protected systems. In addition, a vacuum-tracking scheme is developed to extend the applicability of an OpenFOAM-based solver to gas dynamics in rarefied environments. The proposed approach has been verified through numerical benchmarks and applied to a practical case involving the HYLIFE-II (High Yield Lithium Injection Fusion Energy) chamber. The methodology advances the modeling capabilities for liquid wall-protected IFE systems and provides valuable tools to support their design and optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computational Simulation of a Water-Cooled Heat Pump

A Fortran-language computer program for simulating the operation of a water-cooled vapor-compression heat pump in any orientation with respect to gravity has been developed by modifying a prior general-purpose heat-pump design code used at Oak Ridge National Laboratory (ORNL).

Bozarth, Duane↗

Technology Demonstration Mission (TDM) Evolvable Cryogenics (eCryo) Project: Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) - Test Plan

The initial test of the SHIIVER system includes multilayer insulation and vapor cooled structure. Testing will occur in the In-Space Propulsion Facility (thermal/vacuum) and RATF (acoustic) facilities at Plum Brook Station in Sandusky Ohio. The testing will demonstrate the performance benefits of multilayer insulation and vapor based heat intercept on a “large scale” test article in a manner befitting large upper stages.

Large Scale Hydrogen Testing, Cryogenics, Multilay↗

Heat pipe dynamic behavior

The vapor flow in a heat pipe was mathematically modeled and the equations governing the transient behavior of the core were solved numerically. The modeled vapor flow is transient, axisymmetric (or two-dimensional) compressible viscous flow in a closed chamber. The two methods of solution are described. The more promising method failed (a mixed Galerkin finite difference method) whereas a more common finite difference method was successful. Preliminary results are presented showing that multi-dimensional flows need to be treated. A model of the liquid phase of a high temperature heat pipe was developed. The model is intended to be coupled to a vapor phase model for the complete solution of the heat pipe problem. The mathematical equations are formulated consistent with physical processes while allowing a computationally efficient solution. The model simulates time dependent characteristics of concern to the liquid phase including input phase change, output heat fluxes, liquid temperatures, container temperatures, liquid velocities, and liquid pressure. Preliminary results were obtained for two heat pipe startup cases. The heat pipe studied used lithium as the working fluid and an annular wick configuration. Recommendations for implementation based on the results obtained are presented. Experimental studies were initiated using a rectangular heat pipe. Both twin beam laser holography and laser Doppler anemometry were investigated. Preliminary experiments were completed and results are reported.

Issacci, F.↗

Large-capacity pump vaporizer for liquid hydrogen and nitrogen

Pump vaporizer system delivers 500 standard cubic feet per minute of hydrogen or nitrogen, one system delivers both gases. Vacuum-jacketed pump discharges liquid hydrogen or liquid nitrogen into vaporizing system heated by ambient air. Principal characteristics of the flow and discharge system, pump, and vaporizer are given.

Hauser, J. A.↗

Nonmigrating tides

Recently an interesting advancement in the study of nonmigrating tides has occurred. There have been two distinct approaches in works on this subject. One is based on mechanistic models as considering nonuniform global distribution of water vapor or heating only on land, solving a set of linear equations. It is found that insolation absorption of the nonuniformly distributed water vapor produces only weak nonmigrating tides in the lower thermosphere; the planetary boundary layer heating on land can explain the enhanced tides on land and those with short vertical wavelengths in the stratosphere. The other approach is novel and uses simulation on the general circulation model (GCM). This realistic model can reproduce tides globally and in many details. The enhancement of two nonmigrating modes as eastward traveling modes with a wave number 3 and westward traveling modes with a wave number 5 is in surprisingly good agreement with observation at sea level, at 700 mb and even at 300 mb.

Kato, S.↗

External artery heat pipe

An improved heat pipe with an external artery. The longitudinal slot in the heat pipe wall which interconnects the heat pipe vapor space with the external artery is completely filled with sintered wick material and the wall of the external artery is also covered with sintered wick material. This added wick structure assures that the external artery will continue to feed liquid to the heat pipe evaporator even if a vapor bubble forms within and would otherwise block the liquid transport function of the external artery.

Gernert, Nelson J.↗

Evaporation-Cooled Protective Suits for Firefighters

Suits cooled by evaporation of water have been proposed as improved means of temporary protection against high temperatures near fires. When air temperature exceeds 600 F (316 C) or in the presence of radiative heating from nearby sources at temperatures of 1,200 F (649 C) or more, outer suits now used by firefighters afford protection for only a few seconds. The proposed suits would exploit the high latent heat of vaporization of water to satisfy a need to protect against higher air temperatures and against radiant heating for significantly longer times. These suits would be fabricated and operated in conjunction with breathing and cooling systems like those with which firefighting suits are now equipped

Weinstein, Leonard Murray↗

Energetics of Cu Adsorption on and Adhesion to Rutile-TiO 2 (100) Studied by Cu Vapor Adsorption Calorimetry

The heat of adsorption of Cu vapor versus coverage was measured on rutile-TiO 2 (100) at 300 and 100 K using single-crystal adsorption calorimetry. At these conditions, Cu nanoparticles nucleate and then grow larger. The average Cu particle size versus Cu coverage was measured using He + low-energy ion scattering spectroscopy. These data were analyzed with the recently introduced spherical cap model (SCM) to provide the heat of Cu adsorption and Cu chemical potential versus Cu particle size, as well as the contact angle (67°) and adhesion energy (2.50 J/m 2 ) at the Cu particle/rutile-TiO 2 (100) interface. The hemispherical cap model (HCM) was used to model the data first, and then those HCM results were converted to the more accurate SCM results using a recently published mathematical approximation whose high accuracy was validated here. Furthermore, the adhesion energy of Cu on rutile-TiO 2 (100) measured here is compared to prior values for Ag and Au on rutile-TiO 2 (100), showing a nearly proportional increase in adhesion energy with metal oxophilicity (per unit area).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of lunar base thermal control system options

Long duration human exploration missions to the Moon will require active thermal control systems which have not previously been used in space. The two technologies which are most promising for long term lunar base thermal control are heat pumps and radiator shades. Recent trade-off studies at the Johnson Space Center have focused development efforts on the most promising heat pump and radiator shade technologies. Since these technologies are in the early stages of development and many parameters used in the study are not well defined, a parametric study was done to test the sensitivity to each assumption. The primary comparison factor in these studies was the total mass system, with power requirements included in the form of a mass penalty for power. Heat pump technologies considered were thermally driven heat pumps such as metal hydride, complex compound, absorption and zeolite. Also considered were electrically driven Stirling and vapor compression heat pumps. Radiator shade concepts considered included step shaped, V-shaped and parabolic (or catenary) shades and ground covers. A further trade study compared the masses of heat pump and radiator shade systems.

Ewart, Michael K.↗