Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validated Models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Radiative transfer model validations during the First ISLSCP Field Experiment

Two simple radiative transfer models, the 5S model based on Tanre et al. (1985, 1986) and the wide-band model of Morcrette (1984) are validated by comparing their outputs with results obtained during the First ISLSCP Field Experiment on concomitant radiosonde, aerosol turbidity, and radiation measurements and sky photographs. Results showed that the 5S model overestimates the short-wave irradiance by 13.2 W/sq m, whereas the Morcrette model underestimated the long-wave irradiance by 7.4 W/sq m.

Frouin, Robert↗

NWEI Azura RTI 1/20th Model Validation Wave Tank Test Data

Data from the 1/20th wave tank test of the RTI model. NWEI has licensed intellectual property from RTI, and modified the PTO and retested the 1/20th RTI model that was tested as part of the Wave Energy Prize. The goal of the test was to validate NWEI's simulation models of the model. The test occurred at the University of Maine in Orono.

16 TIDAL AND WAVE POWER↗

NASA Engineering and Safety Center Technical Bulletin No. 14-03: COPV Mechanical Model Validation

Global and local deformation measurements should be incorporated into the composite overwrapped pressure vessel (COPV) design and analysis process to allow correlation of these measurements with finite element analysis (FEA) models. This correlation improves understanding of liner, liner/overwrap interface, and composite deformation response in COPVs. The improved accuracy reduces error in subsequent analyses, such as fracture, fatigue, and stress rupture that are critical for COPV qualification.

Composite Overwrap Pressure Vehicle↗

Noninvasive assessment of mitral inertness: clinical results with numerical model validation

Inertial forces (Mdv/dt) are a significant component of transmitral flow, but cannot be measured with Doppler echo. We validated a method of estimating Mdv/dt. Ten patients had a dual sensor transmitral (TM) catheter placed during cardiac surgery. Doppler and 2D echo was performed while acquiring LA and LV pressures. Mdv/dt was determined from the Bernoulli equation using Doppler velocities and TM gradients. Results were compared with numerical modeling. TM gradients (range: 1.04-14.24 mmHg) consisted of 74.0 +/- 11.0% inertial forcers (range: 0.6-12.9 mmHg). Multivariate analysis predicted Mdv/dt = -4.171(S/D (RATIO)) + 0.063(LAvolume-max) + 5. Using this equation, a strong relationship was obtained for the clinical dataset (y=0.98x - 0.045, r=0.90) and the results of numerical modeling (y=0.96x - 0.16, r=0.84). TM gradients are mainly inertial and, as validated by modeling, can be estimated with echocardiography.

NASA Discipline Cardiopulmonary↗

Chemical kinetics parameters and model validation for the gasification of PCEA nuclear graphite

A series of gasification experiments, using two right cylinder specimens (~ 12.7 x 25.4 mm and 25.4 x 25.4 mm) of PCEA nuclear graphite in ambient airflow, measured the total gasification flux at weight losses up to 41.5% and temperatures (893-1015 K) characteristics of those for in-pores gasification Mode (a) and in-pores diffusion-limited Mode (b). The chemical kinetics parameters for the gasification of PCEA graphite are determined using a multi-parameters optimization algorithm from the measurements of the total gasification rate and transient weight loss in experiments. These parameters are: (i) the pre-exponential rate coefficients and the Gaussian distributions and values of specific activation energies for adsorption of oxygen and desorption of CO gas; (ii) the specific activation energy and pre-exponential rate coefficient for the breakup of stable un-dissociated C(O2) oxygen radicals to form stable (CO) complexes; (iii) the specific activation energy and pre-exponential coefficient for desorption of CO2 gas and; (iv) the initial surface area of reactive free sites per unit mass. This area is consistently 13.5% higher than that for nuclear graphite grades of NBG-25 and IG-110 and decreases inversely proportional with the square root of the initial mass of the graphite specimens in the experiments. Experimental measurements successfully validate the chemical-reactions kinetics model that calculates continuous Arrhenius curves of the total gasification flux and the production rates of CO and CO2 gases. The model results at different total weight losses agree well with measurements and expand beyond the temperatures in the experiments to the diffusion-limited mode of gasification. Also calculated are the production rates of CO and CO2 gases and their relative contributions to the total gasification rate in the experiments as functions of temperature, for total weight losses of 5% and 10%.

kinetics↗

Tall Tower Wind Energy Monitoring and Numerical Model Validation in Northern Nevada

The main objectives of this project were to conduct a tall-tower and sodar field campaign in complex terrain, investigate wind properties relevant to wind energy assessment, and evaluate high-resolution models with fixed and adaptive grid structures. Two 60-m towers at Virginia Peak ridges near Washoe Valley, Nevada, were instrumented with cup and vane anemometers as well as sonic anemometers, and an acoustic sounder (hereafter sodar) was installed near one of the towers. The towers were located 2,700 m apart with a vertical distance of 140 m elevation between their bases. Each tower had a downhill exposure of rolling complex terrain, with the nearby valley floor 3,200 m to the west and 800 m below the summit. Cup anemometers were installed at both towers at 20, 40, and 60 m, wind vanes at 20 and 60 m, and sonic anemometers at 20 and 60 m. The sodar measurements were nominally provided every 10 m in vertical distance from 40 to 200 m with the quality of the data generally decreasing with height. Surface air temperature, atmospheric pressure, and radiation measurements were conducted at 1.5 m AGL at both of the towers. Although the plan was to conduct a 1-year period of data collection, we extended the period (October 5, 2012 through February 24, 2014) to cover for possible data loss from instrument or communication problems. We also present a preliminary analysis of the towers and sodar data, including a detailed inventory of available and missing data as well as outliers. The analysis additionally includes calculation of the Weibull parameters, turbulence intensity, and initial computation of wind power density at various heights.

17 WIND ENERGY↗

LIVVkit 2.1: automated and extensible ice sheet model validation

A collection of scientific analyses, metrics, and visualizations for robustvalidation of ice sheet models is presented using the Land Ice Verificationand Validation toolkit (LIVVkit), version 2.1, and the LIVVkit Extensionsrepository (LEX), version 0.1. This software collection targets stand-aloneice sheet or coupled Earth system models, and handles datasets and analysesthat require high-performance computing and storage. LIVVkit aims to enableefficient and fully reproducible workflows for postprocessing, analysis, andvisualization of observational and model-derived datasets in a shareableformat, whereby all data, methodologies, and output are distributed to usersfor evaluation. Extending from the initial LIVVkit software framework, wedemonstrate Greenland ice sheet simulation validation metrics using thecoupled Community Earth System Model (CESM) as well as an idealizedstand-alone high-resolution Community Ice Sheet Model, version 2 (CISM2),coupled to the Albany/FELIX velocity solver (CISM-Albany or CISM-A). As oneexample of the capability, LIVVkit analyzes the degree to which modelscapture the surface mass balance (SMB) and identifies potential sources ofbias, using recently available in situ and remotely sensed data ascomparison. Related fields within atmosphere and land surface models, e.g.,surface temperature, radiation, and cloud cover, are also diagnosed. Appliedto the CESM1.0, LIVVkit identifies a positive SMB bias that is focusedlargely around Greenland's southwest region that is due to insufficientablation.

58 GEOSCIENCES↗

SPHINX: An SEP Model Validation Infrastructure developed through Community Challenges and the SEP Scoreboards

Solar Energetic Particle (SEP) events are interesting from a scientific perspective as they are the product of a broad set of physical processes from the corona out through the extent of the heliosphere, and provide insight into processes of particle acceleration and transport that are widely applicable in astrophysics. From the operations perspective, SEP events pose a radiation hazard for aviation, electronics in space, and human space exploration, in particular for missions outside of the Earth’s protective magnetosphere including to the Moon and Mars (Whitman et al 2022). For these reasons, SEP modelers have developed a rich and diverse set of models with a wide variety of aims. Some models probe the basic physics at the heart of particle acceleration and transport. Others produce fast statistical forecasts or employ disruptive new techniques like Machine Learning with the goal to assist end users in making operational decisions. To enable a consistent and quantitative understanding of SEP model performance, a generalized, automated validation infrastructure, called SPHINX, is being developed at NASA SRAG in close collaboration with NASA CCMC, NASA M2M, NOAA SWPC, and BIRA-IASB. This infrastructure has been built up through a multi-year community challenge. Starting in 2018 at the SHINE workshop, an effort was launched through SHINE, ISWAT, and ESWW to encourage quantitative, comprehensive, and consistent validation of SEP models. This effort has defined a set of challenge SEP events with the aim of generating quantitative comparisons between forecasts and observations and a set of challenge “non-events” to assess false alarms. In 2023, these challenge lists have been extended to statistically significant numbers with a prescribed set of rules for producing forecasts and supported through the dedicated SEPVAL working meetings. The participation of the research community has allowed the infrastructure to validate all the types of outputs being produced by SEP models. In parallel, the SPHINX code is being applied to real time forecasts submitted to the SEP Scoreboards, ensuring that the validation infrastructure can interpret forecasts produced in an operational scenario and provide metrics meaningful for operations. Upon completion, SPHINX and its interactive user interface, SPHINX-Web, will be made available for public use.

space weather↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

15 GEOTHERMAL ENERGY↗

Characterization Report on Fuels for NEAMS Model Validation

ABSTRACT U3Si2 has become a material of interest for its potential as an accident tolerant fuel used in commercial light water reactors. In order to better understand the nature of the 5f-electrons and mechanisms that govern electrical and heat transport in U3Si2, and to accurately model this compound at all relevant temperatures we have performed detailed studies of this material by means of the heat capacity, electrical resistivity, Seebeck and Hall effects, and thermal conductivity. Polycrystalline samples of U3Si2 were prepared by arc-melting stoichiometric amounts of elemental U and Si. All the results obtained, especially small magneto-resistivity, large low-temperature heat capacity, and characteristic dependence of the Seebeck coefficient, point to delocalized nature of 5f-electrons in U3Si2. The thermal conductivity is ~8.5 W/m-K at room temperature and we show that the lattice part of the total thermal conductivity is small, with electrons dominating heat transport above 300 K. This knowledge of the details of the heat transport in U3Si2 will be useful for researchers working on modeling and simulations of this new advanced fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The executive disruption model of tinnitus distress: Model validation in two independent datasets using factor score regression

This study presents the executive disruption model (EDM) of tinnitus distress and subsequently validates it statistically using two independent datasets (the Construction Dataset: n = 96 and the Validation Dataset: n = 200). The conceptual EDM was first operationalised as a structural causal model (construction phase). Then multiple regression was used to examine the effect of executive functioning on tinnitus-related distress (validation phase), adjusting for the additional contributions of hearing threshold and psychological distress. For both datasets, executive functioning negatively predicted tinnitus distress score by a similar amount (the Construction Dataset: β = −3.50, p = 0.13 and the Validation Dataset: β = −3.71, p = 0.02). Theoretical implications and applications of the EDM are subsequently discussed; these include the predictive nature of executive functioning in the development of distressing tinnitus, and the clinical utility of the EDM.

Clarke, Nathan A.↗

Model Validation and Demonstration of a Hydrogen Fuel Cell Parcel Delivery Truck

With an emphasis on reducing fossil fuel consumption and emissions, major delivery service corporations have begun deploying and operating Class 6 battery electric delivery vans. Fuel cell hybrid delivery vans offer a zero emissions solution with extended range and route planning flexibility. This paper follows a prior publication [1] on the vehicle modeling and design and presents demonstration data and a validation of the prior modeling and design effort. Here, the validation exercise shows that the modeling tools predict performance and energy efficiency within 5% for most of the routes, while the demonstration data shows that in service operation fuel economy was over 14 km/kg of hydrogen gas. In addition, results from a range test showed the vehicle design and onboard hydrogen storage was able to surpass the design target range of 200 km.

08 HYDROGEN↗

Report on THMC Modeling of the Near Field Evolution of a Generic Clay Repository: Model Validation and Demonstration

Shale and clay-rich rock formations have been considered as potential host rocks for geological disposal of high-level radioactive waste throughout the world. Coupled thermal, hydrological, mechanical, and chemical (THMC) processes have a significant impact on the long-term safety of a repository in this type of rocks. For example, the excavation damaged zone (EDZ) near repository tunnels can modify local permeability (resulting from induced fractures), potentially leading to less confinement capability. Maximum allowable temperature is one of the most important design variables for a geological repository, because it determines waste package spacing, distance between disposal galleries, and therefore the overall size (and cost) of the repository for a given amount of waste. This report documents results from four R&D activities to address the above concerns: (1) development and validation of constitutive relationships (Chapter 2); (2) development of a discrete fracture network (DFN) model for investigating coupled processes in the EDZ (Chapter 3); (3) development and validation of a THM model for the Full-Scale Emplacement Experiment (FE) tests at Mont Terri, Switzerland (Chapter 4); and (4) investigation of high-temperature impacts, including both laboratory and modeling studies (Chapter 5). The overall objectives of these activities are to provide an improved understanding of and advanced modeling capabilities for EDZ evolution in clay repositories and the associated coupled processes, and to develop a technical basis for the maximum allowable temperature for a clay repository.

54 ENVIRONMENTAL SCIENCES↗