Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatility analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Chemical changes in thirdhand smoke associated with remediation using an ozone generator

Ozonation is a common remediation approach to eliminate odors from mold, tobacco and fire damage in buildings. Little information exists to: 1) assess its effectiveness; 2) provide guidance on operation conditions; and 3) identify potential risks associated with the presence of indoor ozone and ozonation byproducts. The goal of this study is to evaluate chemical changes in thirdhand smoke (THS) aerosols induced by high levels of ozone, in comparison with THS aerosols aged under similar conditions in the absence of ozone. Samples representing different stages of smoke aging in the absence of ozone, including freshly emitted secondhand smoke (SHS) and THS, were collected inside an 18-m 3 room-sized chamber over a period of 42 h after six cigarettes were consumed. The experiments involved collection and analysis of gas phase species including volatile organic compounds (VOCs), volatile carbonyls, semivolatile organic compounds (SVOCs), and particulate matter. VOC analysis was carried out by gas chromatography/mass spectrometry with a thermal desorption inlet (TD-GC/MS), and volatile carbonyls were analyzed by on-line derivatization with dinitrophenylhydrazine (DNPH), followed by liquid chromatography with UV/VIS detection. SVOCs were extracted from XAD-coated denuders and Teflon-coated fiberglass filters in the absence of ozone. In those extracts, tobacco-specific nitrosamines (TSNAs) and other SVOCs were analyzed by gas chromatography with positive chemical ionization-triple quadrupole mass spectrometric detection (GC/PCI-QQQ-MS), and polycyclic aromatic hydrocarbons (PAHs) were quantified by gas chromatography with ion trap mass spectrometric detection (GC/IT-MS) in selected ion monitoring mode. Particulate matter concentration was determined gravimetrically. In a second experiment, a 300 mg h -1 commercial ozone generator was operated during 1 h, one day after smoke was generated, to evaluate the remediation of THS by ozonation. VOCs and volatile carbonyls were analyzed before and after ozonation. Extracts from fabrics that were exposed in the chamber before and after ozonation as surrogates for indoor furnishings were analyzed by GC/IT-MS, and aerosol size distribution was studied with a scanning mobility particle sizer. Ozone concentration was measured with a photometric detector. An estimated 175 mg ozone reacted with THS after 1 h of treatment, corresponding to 58% of the total O 3 released during that period. Fabric-bound nicotine was depleted after ozonation, and the surface concentration of PAHs adsorbed to fabric specimens decreased by an order of magnitude due to reaction with ozone, reaching pre-smoking levels. These results suggest that ozonation has the potential to remove harmful THS chemicals from indoor surfaces. However, gas phase concentrations of volatile carbonyls, including formaldehyde, acetaldehyde and acetone were higher immediately after ozonation. Ultrafine particles (UFP, in most cases with size <60 nm) were a major ozonation byproduct. UFP number concentrations peaked shortly after ozonation ended, and remained at higher-than background levels for several hours. Based on these results, minimum re-entry times after ozone treatment were predicted for different indoor scenarios. Clearly defining re-entry times can serve as a practical measure to prevent acute exposures to ozone and harmful ozonation byproducts after treatment. This study evaluated potential benefits and risks associated with THS remediation using ozone, providing insights into this technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adventures in Astronomical Time Series Analysis

Welcome to a tour of the volatile, highly active Universe — in stark contrast to earlier serene ``clockwork’’ visions. Innovative data analysis techniques have illuminated explosive physical processes animating these systems. Examples include a Fourier transform suited to the irregular sampling characteristic of much astronomical data, but time domain techniques will be emphasized for these applications: gamma-ray activity in the Crab Nebula, gamma-ray bursts, active galactic nuclei, and gravitational waves. I hope this talk will change some of the ways you carry out statistical data analysis.

Jeffrey D Scargle↗

Launch Complex 39B, SWMU 009, 2023 Performance Monitoring and Air Sparge Expansion Construction Completion Report, Kennedy Space Center, Florida

The 2023 Performance Monitoring and Construction Completion Report (PM-CCR) presents the findings, observations, and results for Air Sparging (AS) operations and expansion activities, as well as sitewide groundwater monitoring for Launch Complex 39B (LC39B), Solid Waste Management Unit (SWMU) 009, at Kennedy Space Center (KSC), Florida. The reporting period for activities covered under this PM-CCR is from January 1, 2023, to December 31, 2023. At LC39B, AS operations began in 2017 in the area west of the launch pad, in the liquid oxygen (LOX) tank area located northwest of the launch pad, and in an area outside of the perimeter fence to protect nearby Outstanding Florida Waters (OFW). The LC39B AS system was installed with 279 AS wells to depths ranging from 23 to 60 feet below land surface (bls), including the sump, correlating to top of screen depths ranging from 20 to 57 feet bls. In December 2022, a total of 22 AS wells were abandoned to support launch pad crane operations, and in November 2023, the system was expanded with five additional AS wells installed to 13 or 17 feet bls near the LOX tank. The remedial objective of the LC39B AS Interim Measure (IM) is to actively decrease concentrations of contaminants of concern (COCs) in groundwater, specifically trichloroethene (TCE), cis-1,2-Dichloroethene (cDCE), and vinyl chloride (VC), to less than their respective Natural Attenuation Default Concentrations (NADCs), so LC39B can transition into a Long-Term Monitoring (LTM) program. This PM-CCR presents the following information for LC39B: • AS system operations and maintenance (O&M) (Year 7 of operation) from January 2023 to December 2023, to include AS trailer relocation in March 2023 and subsequent replacement and re-start in June 2023. • Construction completion details for AS system expansion, which included installation of five new AS wells and one new monitoring well in November 2023. As part of expansion activities, soil samples were also collected for petroleum analysis; no exceedances were identified, and no further investigation for petroleum is warranted. • Performance monitoring results for groundwater sampling events conducted in May/June 2023 (30 wells) and November 2023 (31 wells) in the AS IM area and in the Low Concentration Plume (LCP) areas located north and east of the launch pad for volatile organic compound (VOC) analysis. • Sampling results for one monitoring well, LOX-IW0012S, which is sampled for aluminum on an annual basis (May/June 2023). This well was resampled in November 2023 for both total and dissolved aluminum. Due to a communication error with the laboratory, the May/June 2023 sample was analyzed for total aluminum only. • Groundwater sampling results for per- and polyfluoroalkyl substances (PFAS) collected from seven monitoring wells during the May/June 2023 event to further investigate the Former Sewage Treatment Plant #6 and Percolation Pond area, west of the launch pad. O&M and performance monitoring results show that the AS system at LC39B is operating as designed and meeting performance criteria. Overall runtime was 45 percent (%) during the reporting period (January to December), but the operational runtime was 78% during the timeframe when the system could run (June to December). The most significant downtime contributor was post-launch crane operations following the Artemis launch on November 16, 2022, which lasted until June 2023. During that timeframe, the AS trailer at LC39B was relocated to another KSC remediation site (Wilson Corners) and was subsequently replaced with the AS trailer from the Paint & Oil Locker (POL) remediation site at KSC to resume AS system operations. Performance monitoring results in the AS IM and LCP areas continue to show reduction in COC concentrations over time when compared to baseline levels. In 2023, only one monitoring well (MW0048) detected a COC exceeding its NADC (VC at 740 micrograms per liter [µg/L]), which marks the baseline result for this new well installed during system expansion. Across the rest of the site, VC concentrations have declined or remained stable during the 2023 sampling events. Excluding MW0048, the highest VC result in 2023 was during the May/June sampling event with a concentration of 63 µg/L at MW0032, which is located near MW0048 and the AS expansion area by the LOX tank. TCE was detected in select monitoring wells in the IM area in 2023, but only two locations exceeded the State of Florida Groundwater Cleanup Target Level (GCTL): MW0032 (21 µg/L in May/June 2023 and 9.1 µg/L in November 2023) and MW0036 (5.0 µg/L in November 2023). MW0036 is also located near the LOX tank, on the north side, where the AS system is still operational (Zone Z4). cDCE and trans-1,2-dichloroethene concentrations were less than laboratory method detection limits or their respective GCTLs in all wells sampled in 2023. Near the OFW located northwest of the launch complex, all COC concentrations were less than laboratory method detection limits from monitoring wells (MW0039, MW0040, and LOXTA0002S) sampled in 2023. Aluminum results from LOX-IW0012S, which has been sampled routinely since 2006, detected a total aluminum concentration of 3,900 µg/L during the May/June 2023 sampling event. Results from the November 2023 event detected 5,700 µg/L for total aluminum and 5,500 µg/L for dissolved aluminum. These concentrations slightly decreased from the previous year but remain relatively consistent with historical detections. Aluminum will continue to be sampled on an annual basis at this well as results still exceed the GCTL of 200 µg/L and the Upper Limit of the KSC Background Concentration of 280 µg/L. PFAS results detected nine different PFAS compounds (out of 32 analyzed) from seven wells sampled. Two PFAS compounds, perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), currently have FDEP Provisional GCTLs of 70 nanograms per liter (ng/L). All seven samples collected resulted in concentrations less than the FDEP Provisional GCTLs for both PFAS compounds; no exceedances were observed. PFOS and PFOA also have assigned United States Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) of 4 nanograms per liter (ng/L). None of the PFOS results exceeded the USEPA MCLs. PFOA was detected in two samples above the USEPA MCL at concentrations of 5.8 ng/L (ECS-IW0009I) and 5.5 ng/L (ECS-IW0009S). Three other PFAS compounds, perfluorohexanesulfonic acid (PFHxS), perfluoro-n-nonanoic acid (PFNA), and hexafluoropropylene oxide dimer acid (GenX), currently have USEPA MCLs of 10 ng/L. PFHxS, PFNA, and GenX were not detected at concentrations greater than their respective USEPA MCLs in any of the seven wells. PFAS compounds without FDEP Provisional GCTLs or USEPA MCLs were screened against USEPA RSLs. No other detections exceeded their respective USEPA RSLs. Additional PFAS sampling will be conducted as part of a future PFAS Site Assessment. Based on O&M activities and performance monitoring, the following is recommended for LC39B: • Continue with Year 8 AS system operation within Zone Z4, which includes the AS expansion area. Zone Z3, which has been off since 2018, should remain off as no rebound has been observed. Zones Z1 and Z2, which were turned off at the end of 2022, will remain shut down as monitoring well results have consistently been below GCTLs or have low-level detections with stable or decreasing trends (Meeting Minute 2402-M10, Decision 2402-D30). • Continue with performance monitoring in 2024 with the same monitoring well network as 2023, except with the addition of MW0048 in both semi-annual events. Baseline concentrations for this well were collected during the November 2023 performance monitoring event. Semi-annual sampling should be planned for the May 2024 and November 2024 timeframes (Meeting Minute 2402-M10, Decision 2402-D31). • Continue sampling monitoring well, LOX-IW0012S, for aluminum (total and dissolved) on an annual basis in May 2024. It is also recommended to re-develop this well prior to the next sampling event (Meeting Minute 2402-M10, Decision 2402-D32). The above recommendations for LC39B were presented at the February 2024 KSCRT Meeting, with Team consensus reached on the path forward. The contents of this PM-CCR were also presented at this meeting.

Deborah M Wilson↗

A gas chromatograph experiment for a Titan entry probe

Development of a gas chromatographic technique for analysis of aerosols and volatile organics from a Titan probe is now in progress. Preliminary investigations of aerosol collectors have shown that an electrostatic device should be the most efficient for the particle sizes expected in Titan's atmosphere. Such a device particularly lends itself to development of a simple pyrolyzer which can be used to break down any collected organic conglomerate structures into volatile fragments. Those fragments can subsequently be analyzed by GC providing information about the original chemical structure of the aerosols. Studies show that as little as 1 to 5 micrograms of model aerosol can be successfully analyzed. High altitude atmospheric gas sampling will also be important on Titan due to the great depth of the atmosphere. Studies show that a GC analysis of model Titan atmospheres at pressures approximating this altitude can be made with a sensitivity of a few ten's of parts-per-billion for the trace gases of interest.

Carle, G. C.↗

Lonar crater glasses and high-magnesium australites - Trace element volatilization and meteoritic contamination

Radiochemical neutron activation analysis was used to detect six siderophile elements (Ni, Re, Os, Pd, Ir and Au) and three volatile elements (Zn, Se and Cd) in two basalts, a pumice and three impact glasses from Lonar crater, India, and in six high-magnesium australites. Significant depletions in Re and Se with respect to the parent basalts were found in the Lonar glasses. These depletions, apparently correlated with the degree of shock, are probably due to volatilization under the oxidizing conditions characteristic of earth. One of the australites is substantially enriched in siderophiles relative to the level of these elements in the other five tektites. The element patterns in the australites resemble those of the carbonaceous or cometary component of an Apollo 16 soil.

Morgan, J. W.↗

Two-Dimensional Distribution of Volatiles in the Lunar Regolith from Space Weathering Simulations

We present simulations of space weathering effects on ice deposits in regions of permanent shadow on the Moon. These Monte Carlo simulations follow the effects of space weathering processes on the distribution of the volatiles over time. The model output constrains the coherence of volatile deposits with depth, lateral separation, and time. The results suggest that ice sheets become broken and buried with time. As impacts begin to puncture an initially coherent surficial ice sheet, small areas with a deficit of ice compared to surrounding areas are formed first. As time progresses, holes become prevalent and the anomalous regions are local enhancements of ice concentration in a volume. The 3-D distribution is also heterogeneous because the ice is buried to varying depths in different locations. Analysis of the coherence of ice on 10 cm scales predicts that putative ice sheets in anomalous radar craters are < 100 Myr old. Surface frost becomes homogenized within 20 Myr. The simulations show the data from the LCROSS impact and surrounding region are consistent with the ice deposit in Cabeus being >1000 Myr old. For future in situ analysis of cold trap volatiles, a horizontal range of 10 m is sufficient to acquire surface-based measurements of heterogeneously distributed ice. These results also support previous analyses that Mercury's cold traps are young.

Hurley, Dana M.↗

Application of Long-Path Gas Cell Assisted Infrared Spectroscopy for Detection of Lunar Volatiles and Advanced Curation Efforts

The motivation behind analyzing gaseous samples from the Permanently Shadowed Regions (PSRs) on the lunar surface is built upon the volatiles observed during the LCROSS mission. Advanced curation techniques under cold conditions are essential to the critical scientific analysis of these returned samples. The detection of various volatiles in returned samples by gas-phase infrared (IR) spectroscopy is known to be a powerful tool to understand the resources present in planetary bodies and Astro-materials. The identification and quantification of volatile compounds in returned planetary samples and regolith simulants by advanced and custom-built analytical devices are areas of primary research interest in our group and the Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility. In this context, we discuss recent advancements and experimental results for quick analysis of the major volatiles detected by the LCROSS (water, CO 2 , CH 3 OH, and NH 3 ) by a long-path gas cell/FTIR (Fourier Transform Infrared) spectrometer system. The applicability of this system is demonstrated by qualitative analysis of a series of volatiles measured individually. In addition, the linear dependence of absorption intensity on headspace sample volumes was checked by measuring gas-phase IR absorption spectra of increasing volumes of pure CO 2 gas aliquots. Finally, the instrument performance was evaluated by measuring the relative concentration of NH 3 (g) in methanol solution.

Curation↗

Analysis of the Atmospheric Distribution, Sources, and Sinks of Oxygenated Volatile Organic Chemicals Based on Measurements over the Pacific during TRACE-P

Airborne measurements of a large number of oxygenated volatile organic chemicals (OVOC) were carried out in the Pacific troposphere (0.1-12 km) in winter/spring of 2001 (24 February to 10 April). Specifically, these measurements included acetone (CH3COCH3), methylethyl ketone (CH3COC2H5, MEK), methanol (CH3OH), ethanol (C2H5OH), acetaldehyde (CH3CHO), propionaldehyde (C2H5CHO), peroxyacylnitrates (PANs) (C(sub n)H(sub 2n+1)COO2NO2), and organic nitrates (C(sub n)H(sub 2n+1)ONO2). Complementary measurements of formaldehyde (HCHO), methyl hydroperoxide (CH3OOH), and selected tracers were also available. OVOC were abundant in the clean troposphere and were greatly enhanced in the outflow regions from Asia. Background mixing ratios were typically highest in the lower troposphere and declined toward the upper troposphere and the lowermost stratosphere. Their total abundance (Summation of OVOC) was nearly twice that of nonmethane hydrocarbons (Summation of C2-C8 NMHC). Throughout the troposphere, the OH reactivity of OVOC is comparable to that of methane and far exceeds that of NMHC. A comparison of these data with western Pacific observations collected some 7 years earlier (February-March 1994) did not reveal significant differences. Mixing ratios of OVOC were strongly correlated with each other as well as with tracers of fossil and biomass/biofuel combustion. Analysis of the relative enhancement of selected OVOC with respect to CH3Cl and CO in 12 plumes originating from fires and sampled in the free troposphere (3-11 km) is used to assess their primary and secondary emissions from biomass combustion. The composition of these plumes also indicates a large shift of reactive nitrogen into the PAN reservoir thereby limiting ozone formation. A three-dimensional global model that uses state of the art chemistry and source information is used to compare measured and simulated mixing ratios of selected OVOC. While there is reasonable agreement in many cases, measured aldehyde concentrations are significantly larger than predicted. At their observed levels, acetaldehyde mixing ratios are shown to be an important source of HCHO (and HO x ) and PAN in the troposphere. On the basis of presently known chemistry, measured mixing ratios of aldehydes and PANs are mutually incompatible. We provide rough estimates of the global sources of several OVOC and conclude that collectively these are extremely large (150-500 Tg C / yr) but remain poorly quantified.

Singh, H. B.↗

Battery metal recycling by flash Joule heating

The staggering accumulation of end-of-life lithium-ion batteries (LIBs) and the growing scarcity of battery metal sources have triggered an urgent call for an effective recycling strategy. However, it is challenging to reclaim these metals with both high efficiency and low environmental footprint. We use here a pulsed dc flash Joule heating (FJH) strategy that heats the black mass, the combined anode and cathode, to >2100 kelvin within seconds, leading to ~1000-fold increase in subsequent leaching kinetics. There are high recovery yields of all the battery metals, regardless of their chemistries, using even diluted acids like 0.01 M HCl, thereby lessening the secondary waste stream. The ultrafast high temperature achieves thermal decomposition of the passivated solid electrolyte interphase and valence state reduction of the hard-to-dissolve metal compounds while mitigating diffusional loss of volatile metals. Life cycle analysis versus present recycling methods shows that FJH significantly reduces the environmental footprint of spent LIB processing while turning it into an economically attractive process

36 MATERIALS SCIENCE↗

Integrated Pest Management (IPM) for Early Detection Algal Crop Protection. Final Report

During large-scale, outdoor algal biomass growth, production strain(s) are subject to attack by pathogens, predators, and non-productive competitors, compromising the biomass yield. The project team at UCSD developed and demonstrated the effectiveness of Volatile Organic Compound, VOC, analysis via mass spectrometry (MS) as an early detection system for the presence of production algal ponds infection. The MS detection can then trigger high-resolution melt analysis (HRMA) and enhanced quantitative PCR (qPCR) to identify predatory or pathogenic species precisely. This study gathered the foundational data informing how wholly automated systems monitor the health of production ponds. By detecting the presence of low molecular weight VOCs in the air space above ponds, the instrument was able to mimic “sniffing” the health of the algae pond. This early warning system will be free growers from time-consuming and costly regular surveillance of ponds with the current techniques, such as qPCR and flow-cam assays, which are slower, less sensitive, and not easily fully automated, resulting in increased production efficiency through the reduction of crop loss. This project demonstrated that Chemical Ionization Mass Spectrometry, CIMS, could serve as a real-time monitor of ponds health tracking up to 100 different VOCs simultaneously for continuous periods up to 60 days without interruption, signaling infection within an algal crop 24 to 36 hours prior to techniques such as qPCR and microscopy. While mass spectrometry is an expensive tool, this simple VOC sampling system proved not only to be sensitive and robust but could to multiplexed to monitor several ponds, lowering the overall cost serially. This technology demonstrated a reduction in biomass production cost by approximately 50% compared to growers not employing any detection methodology.

09 BIOMASS FUELS↗

Mariner mission to Encke 1980

Experimental design for the Mariner mission to Comet Encke is considered, examining the following experiments: volatile and nonvolatile chemical analysis, an imaging system for the comet nucleus, the ultraviolet spectrometer, and magnetic field and plasma experiments. Mission design is discussed, emphasizing the mission profile, trajectory and targeting and the spacecraft design.

Yeates, C. M.↗

Effects of Subsurface Sampling & Processing on Martian Simulant Containing Varying Quantities of Water

The presence of water-ice in the Martian subsurface is a subject of much debate and excited speculation. Recent results from the gammaray spectrometer (GRS) on board NASA's Mars Odyssey spacecraft indicate the presence of large amounts of hydrogen in regions of predicted ice stability. The combination of chemistry, low gravitational field (3.71 m/s(exp 2)) and a surface pressure of about 6.36 mbar at the mean radius, place limits on the stability of H2O on the surface, however, results from the GRS indicate that the hydrogen rich phase may be present at a depth as shallow as one meter in some locations on Mars. The potential for water on Mars leads directly to the speculation that life may once have existed there, since liquid water is the unifying factor for environments known to support life on Earth. Lubricant-free drilling has been considered as a means of obtaining water-rich subsurface samples on Mars, and two recent white papers sponsored by the Mars Program have attempted to identify the problems associated with this goal. The two major issues identified were: the engineering challenges of drilling into a water-soil mixture where phase changes may occur; and the potential to compromise the integrity of in-situ scientific analysis due to contamination, volatilization, and mineralogical or chemical changes as a result of processing. This study is a first attempt to simulate lubricantfree drilling into JSC Mars-1 simulant containing up to 50% water by weight. The goal is to address the following: 1) Does sample processing cause reactions or changes in mineralogy which will compromise the interpretation of scientific measurements conducted on the surface? 2) Does the presence of water-ice in the sample complicate (1)? 3) Do lubricant-free drilling and processing leave trace contaminants which may compromise our understanding of sample composition? 4) How does the torque/power required for drilling change as a function of water content and does this lead to unexpected thermal effects?

Menard, J.↗

Performance Assessment of ISS Water Processor Assembly Reactor

Due to modifications to the ISS waste water composition, the concentration of volatile organics has significantly increased in the feed to the Water Processor Assembly (WPA). In parallel, the oxygen supply pressure increased, resulting in a higher flow rate of oxygen to the WPA. Preliminary testing at Hamilton Sund strand indicated that the higher oxygen flow rate would increase the WPA capacity for volatile organics. Following an analysis of the expected waste water composition, personnel at NASA MSFC and Hamilton Sundstrand conducted a test of a flight-like reactor to assess its capacity for the higher organic loads. The results of this test indicate the WPA can accommodate the expected organic load in the ISS waste water with margin.

Carter, Layne↗

Advanced Laser Architecture for Two-Step Laser Tandem Mass Spectrometer

Future astrobiology missions will focus on planets with significant astrochemical or potential astrobiological features, such as small, primitive bodies and the icy moons of the outer planets that may host diverse organic compounds. These missions require advanced instrument techniques to fully and unambiguously characterize the composition of surface and dust materials. Laser desorptionionization mass spectrometry (LDMS) is an emerging instrument technology for in situ mass analysis of non-volatile sample composition. A recent Goddard LDMS advancement is the two-step laser tandem mass spectrometer (L2MS) instrument to address the need for future flight instrumentation to deconvolve complex organic signatures. The L2MS prototype uses a resonance enhanced multi-photon laser ionization mechanism to selectively detect aromatic species from a more complex sample. By neglecting the aliphatic and inorganic mineral signatures in the two-step mass spectrum, the L2MS approach can provide both mass assignments and clues to structural information for an in situ investigation of non-volatile sample composition. In this paper we will describe our development effort on a new laser architecture that is based on the previously flown Lunar Orbiter Laser Altimeter (LOLA) laser transmitter for the L2MS instrument. The laser provides two discrete midinfrared wavelengths (2.8 m and 3.4 m) using monolithic optical parametric oscillators and ultraviolet (UV) wavelength (266 nm) on a single laser bench with a straightforward development path toward flight readiness.

Laser↗

Numerical Study of Water Ice and Molecular Contamination Build Up during JWST Deployment

This paper summarizes a recent numerical analysis of water vapor and volatile condensible material deposition on the James Webb Space Telescope from the initial orbit insertion up to 180 days post launch. The analysis utilized 17 distinct geometry files capturing observatory configuration changes during the deployment. Surface temperature was set from a time-dependent thermal analysis solution. A vapor pressure model was used to calculate the net water ice adsorption. Molecular contamination included a contribution from UV photopolymerization. The analysis predicted levels of ice and molecular accumulation were found to be within the allowable limits specified by the observatory contamination control plan.

James Webb Space Telescope↗

Numerical Study of Water Ice and Molecular Contamination Build Up during JWST Deployment

This paper summarizes a recent numerical analysis of water vapor and volatile condensible material deposition on the James Webb Space Telescope from the initial orbit insertion up to 180 days post launch. The analysis utilized 17 distinct geometry files capturing observatory configuration changes during the deployment. Surface temperature was set from a time-dependent thermal analysis solution. A vapor pressure model was used to calculate the net water ice adsorption. Molecular contamination included a contribution from UV photopolymerization. The analysis predicted levels of ice and molecular accumulation were found to be within the allowable limits specified by the observatory contamination control plan.

James Webb Space Telescope↗

Revisiting the Effects of Seed Liquid Water Content on Isoprene Secondary Organic Aerosol Growth

Aerosol liquid water content (LWC) has been shown to enhance partitioning of water-soluble oxygenated organic vapors into the aerosol particles and facilitate aqueous chemistry, impact SOA formation, composition, and physicochemical properties. Here, this study examines the effect of aerosol liquid water content (LWC) on isoprene SOA formation using effloresced and deliquesced ammonium sulfate ((NH 4 ) 2 SO 4 ) and sodium chloride (NaCl) seed particles in an environmental chamber with photo-oxidation extending over hours under moderate relative humidity (50%-60%). Our findings indicate that isoprene SOA mass yield is not significantly influenced (p value >> 0.05) by the phase state or the chemical identity of the seed particles within a 3–4-hour reaction time scale. Detailed molecular analysis using advanced high resolution mass spectrometry indicates that while both effloresced and deliquesced seed types produced similar molecular formula distributions, deliquesced (NH 4 ) 2 SO 4 slightly favored the production of less volatile compounds. Depth-profiling analysis by single particle mass spectrometry confirmed that isoprene SOA predominantly located on the surfaces of particles with core-shell morphologies, with partial dissolution of the effloresced inorganic salt observed even below the deliquescence relative humidity (DRH) of salt. This finding suggests that assuming dry salt core particles do not interact with SOA coatings, based on salt deliquescence points, may overlook important aqueous chemistry. These results emphasize the critical role of reaction time scale and mixing state on SOA formation and call for further research to understand LWC effects on SOA from different precursors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗