Search NASA⌕ Search

SEARCH · Search NASA

Results for “Voltage drops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Extended testing of xenon ion thruster hollow cathodes

A hollow cathode wear-test of 508 hours was successfully completed at an emission current of 23.0 A and a xenon flow rate of 10 Pa-L/s. This test was the continuation of a hollow cathode contamination investigation. Discharge voltage was stable at 16.7 V. The cathode temperature averaged 1050 C with a 7 percent drop during the wear-test. Discharge ignition voltage was found to be approximately 20 V and was repeatable over four starts. Post-test analyses of the hollow cathode found a much improved internal cathode condition with respect to earlier wear-test cathodes. Negligible tungsten movement occurred and no formation of mono-barium tungstate was observed. These results correlated with an order-of-magnitude reduction in propellant feed-system leakage rate. Ba2CaWO6 and extensive calcium crystal formation occurred on the upstream end of the insert. Ba-Ca compound depositions were found on the Mo insert collar, on the Re electrical leads, and in the gap between the insert and cathode wall. This wear-test cathode was found to be in the best internal condition and had the most stable operating performance of any hollow cathode tested during this contamination investigation.

Sarver-Verhey, Timothy R.↗

Extended-testing of xenon ion thruster hollow cathodes

A hollow cathode wear-test of 508 hours was successfully completed at an emission current of 23.0 A and a xenon flow rate of 10 Pa-L/s. This test was the continuation of a hollow cathode contamination investigation. Discharge voltage was stable at 16.7 V. The cathode temperature averaged 1050 C with a 7 percent drop during the wear-test. Discharge ignition voltage was found to be approximately 20 V and was repeatable over four starts. Post-test analyses of the hollow cathode found a much improved internal cathode condition with respect to earlier wear-test cathodes. Negligible tungsten movement occurred and no formation of mono-barium tungsten was observed. These results correlated with an order-of-magnitude reduction in propellant feed-system leakage rate. Ba2CaWO6 and extensive calcium crystal formation occurred on the upstream end of the insert. Ba-Ca compound depositions were found on the Mo insert collar, on the Re electrical leads, and in the gap between the insert and cathode wall. This wear-test cathode was found to be in the best internal condition and had the most stable operating performance of any hollow cathode tested during this contamination investigation.

Sarver-Verhey, Timothy R.↗

Magnetic field line reconnection experiments. V - Current disruptions and double layers

An investigation is conducted of the stability of a large laboratory plasma current sheet, which has been generated in the process of magnetic field line reconnection, with respect to local current increases. Magnetic flux variations in regions remote from the current sheet generate an inductive voltage in the current loop that drops off inside the plasma in the form of a potential double layer, leading to particle acceleration with velocities much larger than those expected from the steady state electric fields in the plasma. A model for the mechanism of the current disruptions is formulated in which the potential structure leads to ion expulsion, creating a localized density drop. The associated current drop in an inductive circuit drives the potential structure, providing feedback for the disruptive instability. Similarities to, and differences from, magnetospheric substorm phenomena are noted.

Stenzel, R. L.↗

Analog bus driver and multiplexer

For a source-follower signal chain, the ohmic drop in the selection switch causes unacceptable voltage offset, non-linearity, and reduced small signal gain. For an op amp signal chain, the required bias current and the output noise rises rapidly with increasing the array format due to a rapid increase in the effective capacitance caused by the Miller effect boosting up the contribution of the bus capacitance. A new switched source-follower signal chain circuit overcomes limitations of existing op-amp based or source follower based circuits used in column multiplexers and data readout. This will improve performance of CMOS imagers, and focal plane read-out integrated circuits for detectors of infrared or ultraviolet light.

Pain, Bedabrata↗

Reduced T(sub c) Niobium Superconducting HEB Mixers

A reduction in the mixer noise is expected when using superconductors with a lower transition temperature (T(sub c)) since the thermal noise components of the mixer noise should scale with T(sub c). Also, the local oscillator (LO) power required for a diffusion-cooled device should decrease as T(sub c) when T(sub bath) << T(sub c). We previously studied mixing in aluminum based hot-electron bolometers (HEBs) at microwave frequencies (approximately 30 GHz), and observed a significant improvement in noise performance, and a reduction in LO power as predicted. However, the bias voltage range over which good mixer performance was observed was approximately 5 - 10 microV. These devices are thus susceptible to saturation effects, in particular output saturation. In the present work, we have investigated Nb HEBs whose T(sub c) is lowered by applying a magnetic field. The goal is to study a case intermediate between Nb and Al, and hopefully to find properties that will allow use in practical receivers. A 15 kOe perpendicular magnetic field was applied to a Nb HEB (L = 0.16 micrometers, W = 0.08 micrometers, R(sub N) = 90 ohms) to reduce T(sub c) from 5.2 K to 2.4 K. The mixer noise, as inferred from the output noise and the conversion efficiency, decreased from 390 K, DSB to 171 K, DSB. The LO power required for near optimum mixer conversion efficiency (eta(sub mixer) = -9 dB in this device) was 8 nW in zero field, and approximately 2 nW when T(sub c) was reduced to 2.4 K. T(sub bath) = 0.22 K. The conversion bandwidth was previously measured to be 2.4 GHz and the same bandwidth was observed in the presence of a magnetic field. By lowering T(sub c), the voltage range over which good mixing was observed also decreased. However, even with T(sub c) reduced to 2.4 K, the conversion efficiency dropped by 3 dB from its maximum value only when the bias voltage was changed by approximately 90 microV. Saturation effects should thus be much less of a concern in these devices than in Al HEBS. In situations where the application of a large magnetic field is not feasible, we suggest using Ta based HEBS. Ta HEBs should have T(sub c) = 3 - 3.5 K and material properties very similar to Nb.

Siddiqi, I.↗

Thermocouple, multiple junction reference oven

An improved oven for maintaining the junctions of a plurality of reference thermocouples at a common and constant temperature is described. The oven is characterized by a cylindrical body defining a heat sink with axially extended-cylindrical cavity a singularized heating element which comprises a unitary cylindrical heating element consisting of a resistance heating coil wound about the surface of metallic spool with an axial bore defined and seated in the cavity. Other features of the oven include an annular array of radially extended bores defined in the cylindrical body and a plurality of reference thermocouple junctions seated in the bores in uniformly spaced relation with the heating element, and a temperature sensing device seated in the axial bore for detecting temperature changes as they occur in the spool and circuit to apply a voltage across the coil in response to detected drops in temperatures of the spool.

Leblanc, L. P.↗

LabVIEW Serial Driver Software for an Electronic Load

A LabVIEW-language computer program enables monitoring and control of a Transistor Devices, Inc., Dynaload WCL232 (or equivalent) electronic load via an RS-232 serial communication link between the electronic load and a remote personal computer. (The electronic load can operate at constant voltage, current, power consumption, or resistance.) The program generates a graphical user interface (GUI) at the computer that looks and acts like the front panel of the electronic load. Once the electronic load has been placed in remote-control mode, this program first queries the electronic load for the present values of all its operational and limit settings, and then drops into a cycle in which it reports the instantaneous voltage, current, and power values in displays that resemble those on the electronic load while monitoring the GUI images of pushbuttons for control actions by the user. By means of the pushbutton images and associated prompts, the user can perform such operations as changing limit values, the operating mode, or the set point. The benefit of this software is that it relieves the user of the need to learn one method for operating the electronic load locally and another method for operating it remotely via a personal computer.

Scullin, Vincent↗

Simulating the Gradually Deteriorating Performance of an RTG

Degra (now in version 3) is a computer program that simulates the performance of a radioisotope thermoelectric generator (RTG) over its lifetime. Degra is provided with a graphical user interface that is used to edit input parameters that describe the initial state of the RTG and the time-varying loads and environment to which it will be exposed. Performance is computed by modeling the flows of heat from the radioactive source and through the thermocouples, also allowing for losses, to determine the temperature drop across the thermocouples. This temperature drop is used to determine the open-circuit voltage, electrical resistance, and thermal conductance of the thermocouples. Output power can then be computed by relating the open-circuit voltage and the electrical resistance of the thermocouples to a specified time-varying load voltage. Degra accounts for the gradual deterioration of performance attributable primarily to decay of the radioactive source and secondarily to gradual deterioration of the thermoelectric material. To provide guidance to an RTG designer, given a minimum of input, Degra computes the dimensions, masses, and thermal conductances of important internal structures as well as the overall external dimensions and total mass.

Wood, Eric G.↗

On the auroral current-voltage relationship

The auroral relationship between the upward parallel current and the parallel potential drop is predicted using Knight's (1973) collisionless-plasma kinetic theory, and the results are compared with near-simultaneously carried out measurements by DE 1 and DE 2. The agreement between the calculated and observed data is generally good. However, the Knight current, since it does not include upward ionospheric electrons, is not valid in the downward return current region. It was found that suprathermal electron bursts could be observed in the diffuse aurora at the same invariant latitudes, both at high and at low altitudes, suggesting that these bursts are a spatial rather than temporal phenomenon.

Lu, G.↗

Secondary electron emission from a dielectric film subjected to an electric field

An electric field in the range of 0.3,3.3 kV/mm is created normal to a thin film FEP teflon sample which accumulates potential of up to 8.8, 13.7 or 18.3 kV when exposed to an electron beam having energy of 10.0, 15.0 or 20.0 kV, respectively. It is found that the secondary electron emission from the charged sample varies with field. The threshold voltage, at which the secondary electron emission coefficient sigma is unity, drops down from a low field value of 13.73 kV to a high field value of 13.11 kV for a 15.0 kV beam. A computational technique was developed that generates equipotential lines or contours and field vectors above a plane where potential is known. The utilization of conformal transformations allows the extension of the technique to configurations which map into a plane.

Quoc-Nguyen, N.↗

Automatic Control of Arc Process for Making Carbon Nanotubes

An automatic-control system has been devised for a process in which carbon nanotubes are produced in an arc between a catalyst-filled carbon anode and a graphite cathode. The control system includes a motor-driven screw that adjusts the distance between the electrodes. The system also includes a bridge circuit that puts out a voltage proportional to the difference between (1) the actual value of potential drop across the arc and (2) a reference value between 38 and 40 V (corresponding to a current of about 100 A) at which the yield of carbon nanotubes is maximized. Utilizing the fact that the potential drop across the arc increases with the interelectrode gap, the output of the bridge circuit is fed to a motor-control circuit that causes the motor to move the anode toward or away from the cathode if the actual potential drop is more or less, respectively, than the reference potential. Thus, the system regulates the interelectrode gap to maintain the optimum potential drop. The system also includes circuitry that records the potential drop across the arc and the relative position of the anode holder as function of time.

Scott, Carl D.↗

Failure modes and low temperature performance of DC/DC converters

Several standard tests to evaluate key (direct current) DC/DC converter parameters were performed on different models of hybrid radiation-hard DC/DC converters. These tests were done to assess both performance and reliability during space applications that operate the converters at temperatures below the lower military range of -5°C. One of the converters failed near -110°C, but another DC/DC converter model started normally at temperatures as low as 140°C. The latter showed acceptable performance during turn-on, load transient, and synchronization tests even though some minor anomalies were observed. These results show good promise for its use in applications where the DC/DC converters will be operated at lower temperatures. An application circuit was also built and preliminary tests were performed on a commercial (low drop out) LDO type of DC to DC converter with adjustable output voltage. These can be used in point of load (POL) applications. This latter device functioned properly on the few tests that were performed; however, more testing is needed to identify potential issues with space use of this and similar devices.

Leon, Rosa↗

Evaluation of Cycle Life and Characterization of YTP 45 Ah Li-Ion Battery for EMU

Li-ion batteries, with longer cycle life and higher energy density features, are now more and more attractive and applied in multiple fields. The YTP 45 Ah Li-ion battery has been evaluated here and may be employed in EMU in the future. Evaluations were on: (1) Cycle life tests - 500 cycles total (completed 40 cycles in simulated shuttle use mode and 460 cycles in an accelerated use mode, and recorded differential voltage of individual cell in battery); (2) Characterization test - discharge capacity measurement in environment temperature of -10, 25, 50 C before and after 500 cycles; and (3) Thermal testing - charge and discharge at 50 C and -10 C before and after 500 cycles. The battery showed less than a 9% drop of initial discharge capacity and energy within 500 cycles with 475 cycles 59% DOD plus 25 cycles 100% DOD. The EOD voltage ranged from 16.0 to 18.0 V, which fits the requirement for operating the EMU.

Deng, Yi↗

Discharge of 1400 AH lithium thionyl chloride cells into voltage reversal

The development of a high energy density battery is discussed. Tests were conducted on a 1400 AH cell and they include: drop tests, crush tests, vibration and shock tests, hydrostatic pressure effects, charge current tests, and discharge tests. None of these tests led to a venting or explosion of the cell. Criteria are presented for extending RV safety of a 1400 AH cell.

Zolla, A. E.↗

Microfabricated Ice-Detection Sensor

Knowledge of ice conditions on important aircraft lift and control surfaces is critical for safe operation. These conditions can be determined with conventional ice-detection sensors, but these sensors are often expensive, require elaborate installation procedures, and interrupt the airflow. A micromachined, silicon-based, flush-mounted sensor which generates no internal heat has been designed, batch fabricated, packaged, and tested. The sensor is capable of distinguishing between an ice-covered and a clean surface. It employs a bulk micromachined wafer with a 7 micrometer-thick, boron-doped, silicon diaphragm which serves as one plate of a parallel-plate capacitor. This is bonded to a second silicon wafer which contains the fixed electrodes, one to drive the diaphragm by application of a voltage, the other to measure the deflection by a change in capacitance. The diaphragm sizes ranged from 1x1 mm to 3x3 mm, and the gap between parallel-plate capacitors is 2 micrometers. A 200 V d.c. was applied to the driving electrode which caused the capacitance to increase approximately 0.6pf, from a nominal capacitance of 0.6pf, when the surface was ice free. After the sensor was cooled below the freezing point of water, the same voltage range was applied to the drive electrode. The capacitance increased by the same amount. Then a drop of water was placed over the diaphragm and allowed to freeze. This created an approximately 2mm-thick ice layer. The applied 200V d.c. produced no change in capacitance, confirming that the diaphragm was locked to the ice layer. Since the sensor uses capacitive actuation, it uses very little power and is an ideal candidate for inclusion in a wireless sensing system.

DeAnna, Russell G.↗