Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volume Ray Tracing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Photographic Volume Estimation of CPAS Main Parachutes

Capsule Parachute Assembly System (CPAS) flight tests regularly stage a helicopter to observe inflation of 116 ft D o ringsail Main parachutes. These side views can be used to generate 3-D models of inflating canopies to estimate enclosed volume. Assuming a surface of revolution is inadequate because reefed canopies in a cluster are elongated due to mutual aerodynamic interference. A method was developed to combine the side views with upward looking HD video to account for non-circular cross sections. Approximating the cross sections as elliptical greatly improves accuracy. But since that correction requires manually tracing projected outlines, the actual irregular shapes can be used to generate high fidelity models. Compensation is also made for apparent tilt angle. Validation was accomplished by comparing perimeter and projected area with known line lengths and/or high quality photogrammetry.

Ray, Eric S.↗

Lunar Science Conference, 6th, Houston, Tex., March 17-21, 1975, Proceedings. Volume 2 - Chemical and isotopic studies

The chemical compositions of lunar rocks and soils are examined, taking into account sulfur abundances and distributions in mare basalts and their source magmas, lithophile trace and major elements in Apollo 16 and 17 lunar samples, the role of vaporization processes in lunar rock formation, chemical studies of the lunar regolith with emphasis on zirconium and hafnium, a model for the lunar anorthositic gabbro, and trace-element chemistry and reducing capacity of size fractions from the Apollo 16 regolith. Other topics considered are related to lunar chronology, volatile meteoritic elements, isotopic studies, light element geochemistry, and agglutinates and regolith processes. Attention is given to meteoritic material in four terrestrial meteorite craters, the state of meteoritic material on the moon, volatile elements in Allende inclusions, oxygen isotope fractionation in Apollo 17 rocks, cosmogenic isotope production in Apollo deep-core samples, and the effects of exposure conditions on cosmic-ray records in lunar rocks.

Merrill, R. B.↗

LLE Review Volume 115 (April-June 2008)

This volume of the LLE Review, covering April–June 2008, features “Development and Demonstration of Large-Aperture, Tiled-Grating Compressors for the OMEGA EP Petawatt-Class Laser System” by J. Qiao, A. Kalb, D. Canning, T. Nguyen, J. Bunkenburg, and J. H. Kelly. In this article (p. 113), the authors report on the OMEGA EP effort regarding the two large-aperture tiled-grating (1.5-m) compressors. Each compressor, consisting of four sets of tiled-grating assemblies, has been built for the OMEGA EP High-Energy, Petawatt-Class Laser System. The techniques used for tiling individual tiled-grating assemblies and for optimizing the overall performance of a tiled-grating compressor are described. Both compressors achieved subpicosecond-pulse duration without tiling-induced temporal degradation. A ray-tracing model predicted that the static wavefront of the grating tiles dominated focal-spot degradations when submicroradian tiling accuracy is achieved. The tiled-grating compressors delivered a tighter focal spot compared to sub-aperture grating compressors with single central tiles.

42 ENGINEERING↗

A CT-based analytical dose calculation method for HDR {sup 192}Ir brachytherapy

Purpose: This article presents an analytical dose calculation method for high-dose-rate {sup 192}Ir brachytherapy, taking into account the effects of inhomogeneities and reduced photon backscatter near the skin. The adequacy of the Task Group 43 (TG-43) two-dimensional formalism for treatment planning is also assessed. Methods: The proposed method uses material composition and density data derived from computed tomography images. The primary and scatter dose distributions for each dwell position are calculated first as if the patient is an infinite water phantom. This is done using either TG-43 or a database of Monte Carlo (MC) dose distributions. The latter can be used to account for the effects of shielding in water. Subsequently, corrections for photon attenuation, scatter, and spectral variations along medium- or low-Z inhomogeneities are made according to the radiological paths determined by ray tracing. The scatter dose is then scaled by a correction factor that depends on the distances between the point of interest, the body contour, and the source position. Dose calculations are done for phantoms with tissue and lead inserts, as well as patient plans for head-and-neck, esophagus, and MammoSite balloon breast brachytherapy treatments. Gamma indices are evaluated using a dose-difference criterion of 3% and a distance-to-agreement criterion of 2 mm. PTRAN{sub C}T MC calculations are used as the reference dose distributions. Results: For the phantom with tissue and lead inserts, the percentages of the voxels of interest passing the gamma criteria (P{sub {gamma}{>=}1}) are 100% for the analytical calculation and 91% for TG-43. For the breast patient plan, TG-43 overestimates the target volume receiving the prescribed dose by 4% and the dose to the hottest 0.1 cm{sup 3} of the skin by 9%, whereas the analytical and MC results agree within 0.4%. P{sub {gamma}{>=}1} are 100% and 48% for the analytical and TG-43 calculations, respectively. For the head-and-neck and esophagus patient plans, P{sub {gamma}{>=}1} are {>=}99% for both calculation methods. Conclusions: A correction-based dose calculation method has been validated for HDR {sup 192}Ir brachytherapy. Its high calculation efficiency makes it feasible for use in treatment planning. Because tissue inhomogeneity effects are small and primary dose predominates in the near-source region, TG-43 is adequate for target dose estimation provided shielding and contrast solution are not used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ambient occlusion – A powerful algorithm to segment shell and skeletal intrapores in computed tomography data

During the last decades, X-ray (micro-)computed tomography has gained increasing attention for the description of porous skeletal and shell structures of various organism groups. However, their quantitative analysis is often hampered by the difficulty to discriminate cavities and pores within the object from the surrounding region.Herein, we test the ambient occlusion (AO) algorithm and newly implemented optimisations for the segmentation of cavities (implemented in the software Amira). The segmentation accuracy is evaluated as a function of (i) changes in the ray length input variable, and (ii) the usage of AO (scalar) field and other AO-derived (scalar) fields. The results clearly indicate that the AO field itself outperforms all other AO-derived fields in terms of segmentation accuracy and robustness against variations in the ray length input variable. The newly implemented optimisations improved the AO field-based segmentation only slightly, while the segmentations based on the AO-derived fields improved considerably.Additionally, we evaluated the potential of the AO field and AO-derived fields for the separation and classification of cavities as well as skeletal structures by comparing them with commonly used distance-map-based segmentations. For this, we tested the zooid separation within a bryozoan colony, the stereom classification of an ophiuroid tooth, the separation of bioerosion traces within a marble block and the calice (central cavity)-pore separation within a dendrophyllid coral. The obtained results clearly indicate that the ideal input field depends on the three-dimensional morphology of the object of interest The segmentations based on the AO-derived fields often provided cavity separations and skeleton classifications that at were superior to or impossible to obtain with commonly used distance-map-based segmentations. The combined usage of various AO-derived fields by supervisd or unsupervised segmentation algorithms might provide a promising target for future research to further improve the results for this kind of high-end data segmentation and classification. Furthermore, the application of the developed segmentation algorithm is not restricted to X-ray (micro-)computed tomographic data but may potentially be useful for the segmentation of 3D volume data from other sources.

Computed tomography, Micro-computed tomography, Po↗

SU-E-T-355: Efficient Scatter Correction for Direct Ray-Tracing Based Dose Calculation

Purpose: To propose a scatter correction method with linear computational complexity for direct-ray-tracing (DRT) based dose calculation. Due to its speed and simplicity, DRT is widely used as a dose engine in the treatment planning system (TPS) and monitor unit (MU) verification software, where heterogeneity correction is applied by radiological distance scaling. However, such correction only accounts for attenuation but not scatter difference, causing the DRT algorithm less accurate than the model-based algorithms for small field size in heterogeneous media. Methods: Inspired by the convolution formula derived from an exponential kernel as is typically done in the collapsed-cone-convolution-superposition (CCCS) method, we redesigned the ray tracing component as the sum of TERMA scaled by a local deposition factor, which is linear with respect to density, and dose of the previous voxel scaled by a remote deposition factor, D(i)=aρ(i)T(i)+(b+c(ρ(i)-1))D(i-1),where T(i)=e(-αr(i)+β(r(i))2) and r(i)=Σ-(j=1,..,i)ρ(j).The two factors together with TERMA can be expressed in terms of 5 parameters, which are subsequently optimized by curve fitting using digital phantoms for each field size and each beam energy. Results: The proposed algorithm was implemented for the Fluence-Convolution-Broad-Beam (FCBB) dose engine and evaluated using digital slab phantoms and clinical CT data. Compared with the gold standard calculation, dose deviations were improved from 20% to 2% in the low density regions of the slab phantoms for the 1-cm field size, and within 2% for over 95% of the volume with the largest discrepancy at the interface for the clinical lung case. Conclusion: We developed a simple recursive formula for scatter correction for the DRT-based dose calculation with much improved accuracy, especially for small field size, while still keeping calculation to linear complexity. The proposed calculator is fast, yet accurate, which is crucial for dose updating in IMRT optimization.

60 APPLIED LIFE SCIENCES↗

Ordered Mesoporous CMK-5 Carbon with Ultra-Thin Pore Walls and Highly Dispersed Nickel Nanoparticles

Ordered mesoporous CMK-5 carbons with ultra-thin carbon pore walls and highly dispersed Ni nanoparticles have been successfully prepared by using two different SBA-15 silicas as hard templates and 2, 3-di-hydroxynaphtalene (DHN) as a carbon precursor. The nickel precursor was a concentrated nickel nitrate hexahydrate [Ni(NO3)2.6H2O] solution in isopropanol added to the carbon-silica nanocomposites prior to thermal treatments. The samples studied were analyzed by thermogravimetry (TG), nitrogen adsorption at -196 C, powder X-ray diffraction (XRD), Raman spectroscopy, scanning and transmission electron microscopy (STEM) and in situ electron diffraction X-ray spectroscopy (EDX). While TG revealed carbon contents lower than 30 wt%, nitrogen adsorption provided information about homogeneity of carbon thin film deposited onto mesopore walls of ordered silica templates, SBA-15. The templates, carbon-silica nanocomposites and carbon inverse replicas with nickel nanoparticles exhibited uniform pores, high surface areas and large pore volumes. Graphitic carbon was identified by the presence of a characteristic G band on Raman spectra, whereas the diffraction peak attributed to the stacking of graphene planes was not observed by powder XRD.The presence of ordered domains in the carbon materials studied was confirmed by small angle XRD and STEM imaging. In addition, the STEM images revealed that the nickel nanoparticles were uniform in size, ~3nm, and were homogeneously dispersed within ordered tubular carbon walls. A few larger clusters of nickel, ~60nm, present on the external surface, were identified by powder XRD as metallic Ni. The in situ EDX revealed that the small nanoparticles were largely composed of Ni with traces of NiO. Similar nanoparticles dispersions have been reported only for Ni-containing multi-walled carbon nanotubes (CNTs), whereas previously reported ordered mesoporous carbons possessed larger Ni/NiO nanoparticles within CMK-3 nanostructure.

36 MATERIALS SCIENCE↗

Soft x-ray spectrum unfold of K-edge filtered x-ray diode arrays using cubic splines

Cubic spline interpolation is able to recover temporally and spectrally resolved soft x-ray flux from an array of K-edge filtered x-ray diodes without the need for a priori assumptions about the spectrum or the geometry of the emitting volume. The mathematics of the cubic spline interpolation is discussed in detail. The analytic nature of the cubic spline solution allows for analytical error propagation, and the method of calculating the error for radiation temperature, spectral power, and confidence intervals of the unfolded spectrally resolved flux is explained. An unfold of a blackbody model demonstrates the accuracy of the cubic spline unfold. Tests of cubic spline performance using spectrally convolved detailed atomic model simulation results have been performed to measure the method's ability to conserve spectral power to within a factor of 2 or better in line-dominated regimes. The unfold is also demonstrated to work when information from the x-ray diode array is limited due to high signal-to-noise ratios or lack of signal due to over-attenuation or over-filtration of the x-ray diode signal. Here, the robustness of the unfold with respect to background subtraction and raw signal processing, signal alignment between diode traces, limited signal information, and initial conditions is discussed. Results from an example analysis of a halfraum drive are presented to demonstrate the capabilities of the unfold in comparison with previously established methods.

47 OTHER INSTRUMENTATION↗

SU-E-J-215: Onboard Split PET Including the Effects of Attenuation, Scatter, and Random Events

Purpose: Positron emission tomography (PET) using split PET geometry was investigated as an on-board system for functional imaging and PET marker tracking, specifically with tomotherapy. The open dual ring PET would allow measurement of both inter and intra-fractional variation, improving the delineation of tumor volume at any stage in the radiation treatment delivery process. We present results from data obtained using Monte Carlo simulations including the effects of attenuation, random events, and scatter. Methods: PET design was accomplished via Monte Carlo simulations with GATE, the Geant4 Application for Emission Tomography. Images were reconstructed using Software for Image Reconstruction (STIR) with a fully 3D ordered subset expectation maximization (OSEM) image reconstruction technique. Results: Monte Carlo simulations of the split PET geometry indicate that including physical factors that degrade image quality such as attenuation, random events, and scatter still prove the feasibility of near real-time PET for both inter and intra-fractional radiation delivery. The image quality of scan times under 1 minute reveals that it is possible to utilize PET scanning and reconstruction during the treatment session intrafractionally. GATE also simulates the depth information but does not correct obliqueness of the path of line of response so the data is much more realistic than the data obtained with ray tracing. Conclusion: Onboard split PET with TomoTherapy can generate quality images under 1 minute scan times without the need to correct for attenuation, scatter, random events, or depth information of the interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Traceable Ground to On-Orbit Radiometric Calibration System for the Solar Reflective Wavelength Region

This paper describes the combination of a Mie scattering spectral BSDF and BTDF albedo standard whose calibration is traceable to the NIST SIRCUS Facility or the NIST STARR II Facility. The Space-based Calibration Transfer Spectroradiometer (SCATS) sensor uses a simple, invariant optical configuration and dedicated narrow band spectral channel modules to provide very accurate, polarization-insensitive, stable measurements of earth albedo and lunar disk albedo. Optical degradation effects on calibration stability are eliminated through use of a common optical system for observations of the Sun, Earth, and Moon. The measurements from space would be traceable to SI units through preflight calibrations of radiance and irradiance at NIST's SIRCUS facility and the invariant optical system used in the sensor. Simultaneous measurements are made in multiple spectral channels covering the solar reflective wavelength range of 300 nm to 2.4 microns. The large dynamic range of signals is handled by use of single-element, highly-linear detectors, stable discrete electronic components, and a non imaging optical configuration. Up to 19 spectral modules can be mounted on a single-axis drive to give direct pointing at the Earth and at least once per orbit view of the Sun and Moon. By observing the Sun on every orbit, the most stringent stability requirements of the system are limited to short time periods. The invariant optical system for both radiance and irradiance measurements also give excellent transfer to-orbit SI traceability. Emerging instrumental requirements for remotely sensing tropospheric trace species have led to a rethinking by some of the paradigm for Systeme International d'Unites (SI) traceability of the spectral irradiance and radiance radiometric calibrations to spectral albedo (sr(exp -1)) which is not a SI unit. In the solar reflective wavelength region the spectral albedo calibrations are tied often to either the spectral albedo of a solar diffuser or the Moon. This new type of Mie scattering diffuser (MSD) is capable of withstanding high temperatures, and is more Lambertian than Spectralon(tm). It has the potential of covering the entire solar reflective wavelength region. Laboratory measurements have shown that the specular reflectance component is negligible, and indicate that internal absorption by multiple scattering is small. This MSD, a true volume diffuser, exhibits a high degree of radiometric stability which suggests that measurements at the National Institute of Standards and Technology (NIST) could provide a spectral albedo standard. Measurements have been made of its radiometric stability under a simulated space environment of high energy gamma rays, high energy protons, and UV radiation from ambient down to the vacuum ultraviolet H Lyman alpha at 121.6 nm for its eventual use in space as a solar diffuser.

Heath, Donald F.↗

Lyα emitter galaxies at z ∼ 2.8 in the extended Chandra Deep Field South. I. Tracing the large-scale structure via Lyα imaging

We present a narrowband survey with three adjacent filters for z = 2.8–2.9 Lyman alpha (Lyα) emitter (LAE) galaxies in the Extended Chandra Deep Field South (ECDFS), along with spectroscopic follow-up. With a complete sample of 96 LAE candidates in the narrowband NB466, we confirm the large-scale structure at z ∼ 2.8 suggested by previous spectroscopic surveys. Compared to the blank field detected with the other two narrowband filters NB470 and NB475, the LAE-density excess in NB466 (900 arcmin{sup 2}) is ∼ 6.0 ± 0.8 times the standard deviation expected at z ∼ 2.8, assuming a linear bias of 2. The overdense large-scale structure in NB466 can be decomposed into four protoclusters, whose overdensities (each within an equivalent comoving volume 15{sup 3} Mpc{sup 3}) relative to the blank field (NB470+NB475) are in the range of 4.6–6.6. These four protoclusters are expected to evolve into a Coma-like cluster (M ≥ 10{sup 15} M {sub ⊙}) at z ∼ 0. We also investigate the various properties of LAEs at z = 2.8–2.9 and their dependence on the environment. The average star formation rates derived from the Lyα, rest-frame UV, and X-ray bands are ∼4, 10, and <16 M {sub ⊙} yr{sup −1}, respectively, implying a Lyα escape fraction of 25% ≲ f{sub ESC}{sup Lyα} ≲ 40% and a UV continuum escape fraction of f{sub ESC}{sup UV,cont} ≳ 62% for LAEs at z ∼ 2.8. The Lyα photon density calculated from the integrated Lyα luminosity function in the overdense field (NB466) is ∼50% higher than that in the blank field (NB470+NB475), and more bright LAEs are found in the overdense field. The three brightest LAEs, including a quasar at z = 2.81, are all detected in the X-ray band and in NB466. These three LAE-active galactic nuclei contribute an extra 20%–30% Lyα photon density compared to other LAE galaxies. Furthermore, we find that LAEs in overdense regions have larger equivalent width values, bluer U − B and V − R (∼2–3σ) colors compared with those in lower density regions, indicating that LAEs in overdense regions are younger and possible less dusty. We conclude that the structure at z ∼ 2.8 in the ECDFS field is a very significant and rare density peak similar to the SSA22 protocluster, and narrowband imaging is an efficient method of detecting and studying such structures in the high-z universe.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-85: Comparison of Treatment Plans Calculated Using Ray Tracing and Monte Carlo Algorithms for Lung Cancer Patients Having Undergone Radiotherapy with Cyberknife

Purpose: The latest publications indicate that the Ray Tracing algorithm significantly overestimates the dose delivered as compared to the Monte Carlo (MC) algorithm. The purpose of this study is to quantify this overestimation and to identify significant correlations between the RT and MC calculated dose distributions. Methods: Preliminary results are based on 50 preexisting RT algorithm dose optimization and calculation treatment plans prepared on the Multiplan treatment planning system (Accuray Inc., Sunnyvale, CA). The analysis will be expanded to include 100 plans. These plans are recalculated using the MC algorithm, with high resolution and 1% uncertainty. The geometry and number of beams for a given plan, as well as the number of monitor units, is constant for the calculations for both algorithms and normalized differences are compared. Results: MC calculated doses were significantly smaller than RT doses. The D95 of the PTV was 27% lower for the MC calculation. The GTV and PTV mean coverage were 13 and 39% less for MC calculation. The first parameter of conformality, as defined as the ratio of the Prescription Isodose Volume to the PTV Volume was on average 1.18 for RT and 0.62 for MC. Maximum doses delivered to OARs was reduced in the MC plans. The doses for 1000 and 1500 cc of total lung minus PTV, respectively were reduced by 39% and 53% for the MC plans. The correlation of the ratio of air in PTV to the PTV with the difference in PTV coverage had a coefficient of −0.54. Conclusion: The preliminary results confirm that the RT algorithm significantly overestimates the dosages delivered confirming previous analyses. Finally, subdividing the data into different size regimes increased the correlation for the smaller size PTVs indicating the MC algorithm improvement verses the RT algorithm is dependent upon the size of the PTV.

60 APPLIED LIFE SCIENCES↗

Multi-Analytical Investigation of Arsenical Transfer and Remediation on Nineteenth-Century Green Books

Books containing heavy metals, specifically nineteenth-century green arsenical books, have been identified at Northwestern University Libraries, raising health and safety concerns related to handling. Copper acetoarsenite pigments, such as emerald green, were detected on book covers, decorative page edges, labels, and other components using noninvasive analytical techniques including X-ray fluorescence (XRF), Raman spectroscopy, and Fourier-transform infrared (FTIR) spectroscopy. Further examination of selected volumes using synchrotron radiation (SR) techniques revealed pigment migration, degradation, and arsenic transfer to adjacent books. This paper expands on initial findings through two related experiments. The first explored the transfer of arsenic using mechanical friction; Staedtler Mars® white vinyl erasers rubbed on arsenical books generated crumbs which were analyzed via scanning electron microscopy–energy-dispersive X-ray spectroscopy (SEM-EDX). Results confirmed the transfer of arsenic, copper, and lead, with decorative page edges being particularly prone to shedding arsenic onto other materials. The second experiment tested remediation methods on a book contaminated by prolonged exposure to an arsenical neighbor. Surface cleaning using erasers and a vacuum removed flecks of pigment but did not eliminate non-chromophoric arsenic as confirmed by SR analyses, which highlights its presence either as a degradation product embedded within the paper or present in the paper as part of its production process. Findings demonstrate the acute toxicity risk posed by arsenical books and support the need for safe handling protocols. However, materials with only trace levels of arsenic embedded during production may pose a lower risk of transfer. Cross contamination beyond prolonged direct contact appears limited. These results highlight critical considerations for library preservation practices and future research on arsenic in historical materials.

arsenic↗

TEMPORAL AND SPATIAL RELATIONSHIP OF FLARE SIGNATURES AND THE FORCE-FREE CORONAL MAGNETIC FIELD

We investigate the plasma and magnetic environment of active region NOAA 11261 on 2011 August 2 around a GOES M1.4 flare/CME (SOL2011-08-02T06:19). We compare coronal emission at the (extreme) ultraviolet and X-ray wavelengths, using SDO AIA and RHESSI images, in order to identify the relative timing and locations of reconnection-related sources. We trace flare ribbon signatures at ultraviolet wavelengths in order to pin down the intersection of previously reconnected flaring loops in the lower solar atmosphere. These locations are used to calculate field lines from three-dimensional (3D) nonlinear force-free magnetic field models, established on the basis of SDO HMI photospheric vector magnetic field maps. Using this procedure, we analyze the quasi-static time evolution of the coronal model magnetic field previously involved in magnetic reconnection. This allows us, for the first time, to estimate the elevation speed of the current sheet’s lower tip during an on-disk observed flare as a few kilometers per second. A comparison to post-flare loops observed later above the limb in STEREO EUVI images supports this velocity estimate. Furthermore, we provide evidence for an implosion of parts of the flaring coronal model magnetic field, and identify the corresponding coronal sub-volumes associated with the loss of magnetic energy. Finally, we spatially relate the build up of magnetic energy in the 3D models to highly sheared fields, established due to the dynamic relative motions of polarity patches within the active region.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-CD-201-05: Characterization of a Novel Light-Collimating Tank Optical-CT System for 3D Dosimetry

Purpose: Comprehensive 3D dosimetry is highly desirable for advanced clinical QA, but costly optical readout techniques have hindered widespread implementation. Here, we present the first results from a cost-effective Integrated-lens Dry-tank Optical Scanner (IDOS), designed for convenient 3D dosimetry readout of radiochromic plastic dosimeters (e.g. PRESAGE). Methods: The scanner incorporates a novel transparent light-collimating tank, which collimates a point light source into parallel-ray CT geometry. The tank was designed using an in-house Monte-Carlo optical ray-tracing simulation, and was cast in polyurethane using a 3D printed mould. IDOS spatial accuracy was evaluated by imaging a set of custom optical phantoms, with comparison to x-ray CT images. IDOS dose measurement performance was assessed by imaging PRESAGE dosimeters irradiated with simple known dose distributions (e.g., 4 field box 6MV treatment with Varian Linac). Direct comparisons were made to images from our gold standard DLOS scanner and calculated dose distributions from a commissioned Eclipse planning system. Results: All optical CT images were reconstructed at 1mm isotropic resolution. Comparison of IDOS and x-ray CT images of the geometric phantom demonstrated excellent IDOS geometric accuracy (sub-mm) throughout the dosimeter. IDOS measured 3D dose distribution agreed well with prediction from Eclipse, with 95% gamma pass rate at 3%/3mm. Cross-scanner dose measurement gamma analysis shows >90% of pixels passing at 3%/3mm. Conclusion: The first prototype of the IDOS system has demonstrated promising performance, with accurate dosimeter readout and negligible spatial distortion. The use of optical simulations and 3D printing to create a light collimating-tank has dramatically increased convenience and reduced costs by removing the need for expensive lenses and large volumes of refractive matching fluids.

60 APPLIED LIFE SCIENCES↗

Investigation on the structural and nonlinear optical properties of Pt doped TiO{sub 2} nanoparticles

Graphical abstract: The open aperture Z-scan traces of Pt doped TiO{sub 2} nanoparticles at different Pt concentrations were carried out at an irradiation wavelength of 532 nm. It was numerically found that, two photon absorption (TPA) type process gives the best fit to the obtained open aperture Z-scan data. The nonlinear transmission was found to be of third order as it fits to a two-photon absorption. The optical limiting performances of nanoparticles were greatly enhanced with increased volume ratio of Pt. Increasing particle size reduced the limiting threshold and enhanced the optical limiting performance. - Highlights: • Pt doped TiO{sub 2} nanoparticles with different concentrations of Pt have been synthesized by sol–gel method. • The average fluorescence lifetime decreases as the volume fraction of Pt dopant increases. • The effects of Pt content on the optical limiting property were investigated by open aperture Z-scan measurements done at 532 nm using 5 ns laser pulses. • The values of the third-order nonlinearities of nanoparticles are interesting from the application point of view which could be used as a potential candidate for the application of nonlinear optical device. - Abstract: Pt doped TiO{sub 2} nanoparticles with different concentrations of Pt were prepared by sol–gel method. X-ray diffraction (XRD) study reveals that the samples have a homogeneous anatase phase tetragonal system and the lattice parameter analysis indicates that Pt ions substitute into the lattice of TiO{sub 2}. The addition of dopant increases the growth of TiO{sub 2} grains, agglomerates them and shifts the absorption band of TiO{sub 2} from ultraviolet to visible region. The incorporation of Pt in TiO{sub 2} is also confirmed by fluorescence quenching and the fluorescence lifetime decreases as the volume fraction of Pt dopant increases. Open aperture Z-scan measurements done at 532 nm using 7 ns laser pulses show nonlinear absorption which arises from an effective two photon absorption process. The nonlinear optical properties are characterized by using fluence dependent transmittance measurements in order to reveal the optical limiting effects. It is found that the optical limiting performances of nanoparticles were greatly enhanced with increased concentration of Pt.

36 MATERIALS SCIENCE↗

The Universe at Moderate Redshift

The report covers the work done in the past year and a wide range of fields including properties of clusters of galaxies; topological properties of galaxy distributions in terms of galaxy types; patterns of gravitational nonlinear clustering process; development of a ray tracing algorithm to study the gravitational lensing phenomenon by galaxies, clusters and large-scale structure, one of whose applications being the effects of weak gravitational lensing by large-scale structure on the determination of q(0); the origin of magnetic fields on the galactic and cluster scales; the topological properties of Ly(alpha) clouds the Ly(alpha) optical depth distribution; clustering properties of Ly(alpha) clouds; and a determination (lower bound) of Omega(b) based on the observed Ly(alpha) forest flux distribution. In the coming year, we plan to continue the investigation of Ly(alpha) clouds using larger dynamic range (about a factor of two) and better simulations (with more input physics included) than what we have now. We will study the properties of galaxies on 1 - 100h(sup -1) Mpc scales using our state-of-the-art large scale galaxy formation simulations of various cosmological models, which will have a resolution about a factor of 5 (in each dimension) better than our current, best simulations. We will plan to study the properties of X-ray clusters using unprecedented, very high dynamic range (20,000) simulations which will enable us to resolve the cores of clusters while keeping the simulation volume sufficiently large to ensure a statistically fair sample of the objects of interest. The details of the last year's works are now described.

Cen, Renyue↗

General guide concepts for compact, high-brilliance neutron moderators

The trend in neutron sciences is toward integrating compact, high-brightness moderators into new or upgraded facilities. Transporting neutrons from the source to the sample position with a phase-space distribution tailored to specific requirements is crucial to leverage high source brilliance. Here we have investigated four guide concepts using Monte Carlo ray tracing simulations: Montel beamline with nested Kirkpatrick–Baez mirrors, curved-tapered beamline with a bender and straight sections, straight-elliptical beamline, and curved-elliptical beamline. The straight-elliptical (curved-elliptical) beamline features two half-ellipse guides connected by a straight (non-straight) guide section. The neutron transport efficiency and phase space homogeneity have been quantitatively compared. Our results show that the straight-elliptical beamline performs best because of few neutron bounces on the guide surface with small reflection angles, minimizing flux loss. The Montel beamline provides the best spatial confinement of neutrons within the desired region; however, there is a high thermal-neutron loss due to large reflection angles. The curved-tapered beamline suffers from significant flux loss due to high bounces, and it shows a non-uniform angular distribution related to broad ranges of bounces and reflection angles. The non-straight guide section of the curved-elliptical beamline increases the phase space inhomogeneity, leading to a spatially non-uniform beam profile. The results apply to general neutron instruments that require transporting thermal and cold neutrons from a compact, high-brilliance moderator to the sample location with a moderate phase-space volume.

47 OTHER INSTRUMENTATION↗