Search NASA⌕ Search

SEARCH · Search NASA

Results for “WIDTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Giant dipole resonance width in nuclei near Sn at low temperature and high angular momentum

High energy {gamma} rays in coincidence with low energy yrast {gamma} rays have been measured from {sup 113}Sb, at excitation energies of 109 and 122 MeV, formed by bombarding {sup 20}Ne on {sup 93}Nb at projectile energies of 145 and 160 MeV, respectively, to study the role of angular momentum (J) and temperature (T) over giant dipole resonance (GDR) width ({gamma}). The maximum populated angular momenta for fusion were 67({Dirac_h}/2{pi}) and 73({Dirac_h}/2{pi}), respectively, for the above-mentioned beam energies. The high energy photons were detected using a Large Area Modular BaF{sub 2} Detector Array (LAMBDA) along with a 24-element multiplicity filter. After pre-equilibrium corrections, the excitation energy E* was averaged over the decay steps of the compound nucleus (CN). The average values of temperature, angular momentum, CN mass, etc., have been calculated using the statistical model code CASCADE. Using those average values, results show the systematic increase of GDR width with T, which is consistent with Kusnezov parametrization and the thermal shape fluctuation model (TSFM). The rise of GDR width with temperature also supports the assumptions of adiabatic coupling in the TSFM. But the GDR widths and corresponding reduced plots with J are not consistent with those of the theoretical model at high spins.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nonlinear classical model for the decay widths of isoscalar giant monopole resonances

The decay of the isoscalar giant monopole resonance (ISGMR) in nuclei is studied by means of a nonlinear classical model consisting of several noninteracting nucleons (particles) moving in a potential well with an oscillating nuclear surface (wall). The motion of the nuclear surface is described by means of a collective variable that appears explicitly in the Hamiltonian as an additional degree of freedom. The total energy of the system is therefore conserved. Although the particles do not directly interact with each other, their motions are indirectly coupled by means of their interaction with the moving nuclear surface. We consider as free parameters in this model the degree of collectivity and the fraction of nucleons that participate to the decay of the collective excitation. Specifically, we have calculated the decay width of the ISGMR in the spherical nuclei {sup 208}Pb, {sup 144}Sm, {sup 116}Sn, and {sup 90}Zr. Despite its simplicity and its purely classical nature, the model reproduces the trend of the experimental data that show that with increasing mass number the decay width decreases. Moreover the experimental results (with the exception of {sup 90}Zr) can be well fitted using appropriate values for the free parameters mentioned above. It is also found that these values allow for a good description of the experimentally measured {sup 112}Sn and {sup 124}Sn decay widths. In addition, we give a prediction for the decay width of the exotic isotope {sup 132}Sn for which there is experimental interest. The agreement of our results with the corresponding experimental data for medium-heavy nuclei is dictated by the underlying classical mechanics, i.e., the behavior of the maximum Lyapunov exponent as a function of the system size.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron decay width of one-particle resonant levels in deformed nuclei

The neutron partial decay width of one-particle resonant levels that are the bandhead states in odd-N deformed nuclei is estimated in the formalism with a real-energy variable, using the width of one-particle resonance calculated in terms of eigenphase. It is shown that because of the presence of various (lj) components in a given one-particle resonant level of deformed nuclei, the neutron decay width can be quite different from the one obtained from assuming a spherically symmetric nuclear shape. As a numerical example, the formalism is applied to the case of the nucleus {sub 4}{sup 13}Be{sub 9}, which lies outside the neutron drip line by 100-200 keV. Considering that the core of the nucleus consisting of four protons and eight neutrons is most likely prolately deformed, we point out the possibility that two lowest lying levels have I{sup {pi}}=1/2{sup +} for the N=9 nucleus, and the higher lying one may have a neutron decay width that is much narrower than the one expected for an s{sub 1/2} level at the same resonance energy. The structure of some {omega}{sup {pi}}=1/2{sup +} one-particle resonant levels, which are smoothly connected to weakly bound one-particle levels as the potential strength becomes stronger, is also analyzed using the present formalism.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bounding the Higgs width at the LHC: complementary results from H→WW

We investigate the potential of the process gg → H→ WW to provide bounds on the Higgs width. Recent studies using off-shell H→ ZZ events have shown that Run 1 LHC data can constrain the Higgs width, $\Gamma_H < (25-45) \Gamma_{H}^{\rm SM}$. Using 20 fb-1 of 8 TeV ATLAS data, we estimate a bound on the Higgs boson width from the WW channel between $\Gamma_H < (100-500) \Gamma_H^{SM}$. The large spread in limits is due to the range of cuts applied in the existing experimental analysis. The stricter cuts designed to search for the on-shell Higgs boson limit the potential number of off-shell events, weakening the constraints. As some of the cuts are lifted the bounds improve. We show that there is potential in the high transverse mass region to produce upper bounds of the order of $(25-50) \Gamma_H^{SM}$, depending strongly on the level of systematic uncertainty that can be obtained. Thus, if these systematics can be controlled, a constraint on the Higgs boson width from the H → WW$ decay mode can complement a corresponding limit from H → ZZ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved measurements of two-photon widths of the χ c J states and helicity analysis for χ c 2 → γ γ

Based on 448.1 x 10 6 ψ(3686) events collected with the BESIII detector, the decays ψ(3686) → γχ cJ ,χ cJ → γγ(J = 0,1,2) are studied in this paper. The decay branching fractions of χ c0,2 → γγ are measured to be β(χ c0 → γγ) = (1.93 ± 0.08 ± 0.05 ± 0.05) x 10 -4 and β(χ c2 → γγ) = (3.10 ± 0.09 ± 0.07 ± 0.11) x 10 -4 , which correspond to two-photon decay widths of Γ γγ (χ c0 ) = 2.03 ± 0.08 ± 0.06 ± 0.13 keV and Γ γγ (χ c2 ) = 0.60 ± 0.02 ± 0.01 ± 0.04 keV with a ratio of R = Γ γγ (χ c2 )/Γ γγ (χ c0 ) = 0.295 ± 0.014 ± 0.007 ± 0.027, where the uncertainties are statistical, systematic and associated with the uncertainties of β(ψ(3686) → γχ c0,2 ) and the total widths Γ(χ c0,2 ), respectively. For the forbidden decay of χ c1 → γγ, no signal is observed, and an upper limit on the two-photon width is obtained to be Γ γγ (χ c1 ) < 5.3 eV at the 90% confidence level. Finally, the ratio of the two-photon widths between helicity-zero and helicity-two components in the decay χ c2 → γγ is also measured to be f 0/2 = Γ λ=0 γγ (χ c2 )/Γ λ=2 γγ (χ c2 ) = (0.0 ± 0.6 ± 1.2) x 10 -2 , where the uncertainties are statistical and systematic, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of frequency and pulse width on electron density, hydrogen peroxide generation, and perfluorooctanoic acid mineralization in a nanosecond pulsed discharge gas-liquid plasma reactor

Plasma electron density and temperature were characterized in a continuous flowing gas-liquid film reactor with argon carrier gas by time-resolved optical emission spectroscopy. The plasma parameters were studied as a function of time for varying pulse widths and frequencies. Pulse frequency was varied between 1 and 10 kHz at 16 kV (input voltage) and 40 ns (pulse width) using an Eagle Harbor Technologies, Inc. (EHT) power supply and 5–100 kHz using an Airity Technologies, LLC (AT) power supply. The pulse width was varied between 40 and 200 ns at 16 kV, 2 kHz with the EHT power supply. Optimal frequencies of 5 and 20 kHz were observed for peak electron density with EHT and AT power supplies, respectively. The peak electron density increased with increasing pulse width between 40 and 200 ns using the EHT power supply. Hydrogen peroxide exiting the reactor in the liquid phase increased with discharge power irrespective of the power supply or pulse parameters. Mineralization of 12.5, 50, and 200 ppm perfluorooctanoic acid (PFOA) dissolved in DI water to fluoride (F - ) correlated to the peak electron density. Glycerol, a liquid-phase hydroxyl radical scavenger, depleted hydrogen peroxide but did not affect PFOA mineralization. CO, a gas-phase hydroxyl radical scavenger, led to a reduction in the formation of F - production, suggesting hydroxyl radicals in the gas-liquid film play a necessary, but not singular, role in mineralization of PFOA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accurate quantification of width and density of bone structures by computed tomography

In computed tomography (CT), the representation of edges between objects of different densities is influenced by the limited spatial resolution of the scanner. This results in the misrepresentation of density of narrow objects, leading to errors of up to 70% and more. Our interest is in the imaging and measurement of narrow bone structures, and the issues are the same for imaging with clinical CT scanners, peripheral quantitative CT scanners or micro CT scanners. Mathematical models, phantoms and tests with patient data led to the following procedures: (i) extract density profiles at one-degree increments from the CT images at right angles to the bone boundary; (ii) consider the outer and inner edge of each profile separately due to different adjacent soft tissues; (iii) measure the width of each profile based on a threshold at fixed percentage of the difference between the soft-tissue value and a first approximated bone value; (iv) correct the underlying material density of bone for each profile based on the measured width with the help of the density-versus-width curve obtained from computer simulations and phantom measurements. This latter curve is specific to a certain scanner and is not dependent on the densities of the tissues within the range seen in patients. This procedure allows the calculation of the material density of bone. Based on phantom measurements, we estimate the density error to be below 2% relative to the density of normal bone and the bone-width error about one tenth of a pixel size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams

Monte Carlo simulations of x-ray beams typically take parameters of the electron beam in the accelerating waveguide to be free parameters. In this paper, a methodology is proposed and implemented to determine the energy, spectral width, and beam divergence of the electron source. All treatment head components were removed from the beam path, leaving only the exit window. With the x-ray target and flattener out of the beam, uncertainties in physical characteristics and relative position of the target and flattening filter, and in spot size, did not contribute to uncertainty in the energy. Beam current was lowered to reduce recombination effects. The measured dose distributions were compared with Monte Carlo simulation of the electron beam through the treatment head to extract the electron source characteristics. For the nominal 6 and 18 MV x-ray beams, the energies were 6.51{+-}0.15 and 13.9{+-}0.2 MeV, respectively, with the uncertainties resulting from uncertainties in the detector position in the measurement and in the stopping power in the simulations. Gaussian spectral distributions were used, with full widths at half maximum ranging from 20{+-}4% at 6 MV to 13{+-}4% at 18 MV required to match the fall-off portion of the percent-depth ionization curve. Profiles at the depth of maximum dose from simulations that used the manufacturer-specified exit window geometry and no beam divergence were 2-3 cm narrower than measured profiles. Two simulation configurations yielding the measured profile width were the manufacturer-specified exit window thickness with electron source divergences of 3.3 degree sign at 6 MV and 1.8 deg. at 18 MV and an exit window 40% thicker than the manufacturer's specification with no beam divergence. With the x-ray target in place (and no flattener), comparison of measured to simulated profiles sets upper limits on the electron source divergences of 0.2 deg. at 6 MV and 0.1 deg. at 18 MV. A method of determining source characteristics without mechanical modification of the treatment head, and therefore feasible in clinics, is presented. The energies and spectral widths determined using this method agree with those determined with only the exit window in the beam path.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-428: Dosimetric Impact of Multileaf Collimator Leaf Width On Single and multiple Isocenter Stereotactic IMRT Treatment Plans for multiple Brain Tumors

Purpose: To assess the impacts that multileaf collimator (MLC) leaf width has on the dose conformity and normal brain tissue doses of single and multiple isocenter stereotactic IMRT (SRT) plans for multiple intracranial tumors. Methods: Fourteen patients with 2–3 targets were studied retrospectively. Patients treated with multiple isocenter treatment plans using 9 to 12 non-coplanar beams per lesion underwent repeat planning using single isocenter and 10 to 12 non-coplanar beams with 2.5mm, 3mm and 5mm MLC leaf widths. Brainlab iPlan treatment planning system for delivery with the 2.5mm MLC served as reference. Identical contour sets and dose-volume constraints were applied. The prescribed dose to each target was 25 Gy to be delivered over 5 fractions with a minimum of 99% dose to cover ≥ 95% of the target volume. Results: The lesions and normal brains ranged in size from 0.11 to 51.67cc (median, 2.75cc) and 1090 to 1641cc (median, 1401cc), respectively. The Paddick conformity index for single and multiple isocenter (2.5mm vs. 3mm and 5mm MLCs) was (0.79±0.08 vs. 0.79±0.07 and 0.77±0.08) and (0.79±0.09 vs. 0.77±0.09 and 0.76±0.08), respectively. The average normal brain volumes receiving 15 Gy for single and multiple isocenter (2.5mm vs. 3mm and 5mm MLCs) were (3.65% vs. 3.95% and 4.09%) and (2.89% vs. 2.91% and 2.92%), respectively. Conclusion: The average dose conformity observed for the different leaf width for single and multiple isocenter plans were similar, throughout. However, the average normal brain volumes receiving 2.5 to 15 Gy were consistently lower for the 2.5mm MLC leaf width, especially for single isocenter plans. The clinical consequences of these integral normal brain tissue doses are still unknown, but employing the use of the 2.5mm MLC option is desirable at sparing normal brain tissue for both single and multiple isocenter cases.

60 APPLIED LIFE SCIENCES↗

SU-E-T-534: Dosimetric Effect of Multileaf Collimator Leaf Width On Volumetric Modulated Arc Stereotactic Radiotherapy for Spine Tumors

Purpose: To study the dosimetric impact of MLC leaf width in patients treated with Volumetric Modulated Arc Therapy (VMAT) for spine Stereotactic Body radiation Therapy (SBRT). Methods: Twelve spine SBRT patients were retrospectively selected for this study. The patients were treated with IMRT following the RTOG-0631 of spine metastasis. The prescription dose was 16 Gy in one fraction to 90% of the target volume (V16 > 90%). The maximum spinal cord dose of 14 Gy and 10% of the cord receiving < 10 Gy (V10) were set as dose constraints. For purpose of this study, three dual arc VMAT plans were created for each patient using three different MLC leaf widths: 2.5 mm, 4mm, and 5mm. The compliance to RTOG 0631, conformal index (CI), dose gradient index (DGI), and number of monitor units (MUs) were compared. Results: The average V16 of the target was 91.91±1.36%, 93.73±2.38%, and 92.25±2.49% for 2.5 mm, 4 mm, and 5 mm leaf widths, respectively (p=0.39). Accordingly, the average CI was 1.36±0.39, 1.36±0.34, and 1.41±0.3 (0.96), respectively. The average DGI was 0.24 ± 0.05, 0.22 ± 0.05, and 0.23 ± 0.04, respectively (p=0.86). The average spinal cord maximum dose was 12.10 ± 0.88 Gy, 12.52 ± 1.15 Gy, and 12.05 ± 1.12 (p=0.75) and V10 was 2.69 ± 1.71 cc, 5.43 ± 2.16 cc, and 3.71 ± 2.34 cc (p=0.15) for 2.5 mm, 4 mm, and 5 mm leaf widths, respectively. According, the average number of MUs was 4255 ± 431 MU, 5049 ± 1036 MU, and 4231 ± 580 MU respectively (p=0.17). Conclusion: The use of 2.5 mm, 4 mm, and 5 mm MLCs achieved similar VMAT plan quality as recommended by RTOG-0631. The dosimetric parameters were also comparable for the three MLCs.

60 APPLIED LIFE SCIENCES↗

SU-E-T-633: Dose Differences in Lung Cancer SBRT: The Influences of MLC Width

Purpose: The aim is to compare the plan dose distribution of lung SBRT with MLCs in different width. Methods: Cases with phase INSCLC were enrolled. 9 cases were undergone 4D-CT scanning in the supine position with both arms raised. 3D-CT images without IV contrast were afterwards acquired with 3mm thickness and used for dose calculations. ITV was generated by using the inspiration and expiration images. The ITV can be expanded by geometric set-up uncertainty (5 mm) to generate the PTV. All chest normal tissues including chest wall were contoured by doctors. A total dose of 55 Gy will be given in 5 fractions within 10–14 days with an inter fraction interval of 2–3 days. Guided by the RTOG trial 3502 protocol, 11–13 non-coplanar fields with 6MV photon were arranged. Three types of MLCs with width of 3mm, 5mm and 10mm at isocenter position, were used separately to generate a CRT plan for each case. Monte Carlo algorithm was applied to dose calculation. All plans were adjusted as possible to meet the dose constraints. Dose-volume parameters from plans as followed were compared and analysized: PTV V55Gy, COMPTV D70% (70% of normalization dose), volume A (body minus PTV), and R100% and R50% (the ratio of x% of prescription dose isoline volume to PTV volume). Results: MLCs, 3mm and 5mm wide, played the identical roles on dosimetry of the plans, excluding the parameter volume A (p<0.05). On the contrary, MLC with width of 10mm was significantly inferior to the other two types on most parameters (p<0.05). For R50%, all types contributed equally (p>0.05). Conclusion: For lung cancer SBRT, MLC width had influence to dosimetry, especially in irradiation area. Small size MLC, e.g. 3mm and 5mm, are helpful to generate a high quality treatment plan, which could meet the strict criteria for targets and OAR.

60 APPLIED LIFE SCIENCES↗

The S-D mixing and dielectron widths of higher charmonium 1{sup --} states

The dielectron widths of {psi}(4040), {psi}(4160), and {psi}(4415), and their ratios are shown to be in good agreement with experiment, if in all cases the S-D mixing with a large mixing angle {theta} {approx_equal} 34 deg. is taken. Arguments are presented why continuum states give small contributions to the wave functions at the origin. We find that the Y (4360) resonance, considered as a pure 3 {sup 3}D{sub 1} state, would have very small dielectron width, {Gamma}{sub ee}(Y (4360)) = 0.060 keV. On the contrary, for large mixing between the 4 {sup 3}S{sub 1} and 3 {sup 3}D{sub 1} states with the mixing angle {theta} = 34.8 deg., {Gamma}{sub ee}({psi}(4415)) = 0.57 keV coincides with the experimental number, while a second physical resonance, probably Y (4360), has also a rather large {Gamma}{sub ee}(Y ({approx}4400)) = 0.61 keV. For the higher Y (4660) resonance, considered as a pure 5 {sup 3}S{sub 1} state, we predict the dielectron width {Gamma}{sub ee}(Y (4660)) = 0.70 keV, but it becomes significantly smaller, namely 0.31 keV, if the mixing angle between the 5 {sup 3}S{sub 1} and 4 {sup 3}D{sub 1} states has the characteristic value {theta} = 34 deg. The mass and dielectron width of the 6 {sup 3}S{sub 1} charmonium state are calculated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Concerning the width of spark channels with different polarities in submicrosecond sliding discharges in noble gases

Previously, the parameters of submicrosecond (with a duration of <200 ns) multichannel high-current discharges sliding along a ceramic surface in Ne, Ar, and Xe were studied only for the negative polarity of the applied voltage. The experimental data indicate that the channels expand in the transverse direction mainly due to electron drift from the channel surface layer under the action of the electric field perpendicular to the channel axis and subsequent gas ionization by these electrons. To investigate mechanisms for the channel development in a sliding discharge-in particular, to determine the contribution of electron drift-it is necessary to carry out experiments similar to those performed earlier for the opposite polarity of the applied voltage. Here, the results of measurements of the widths of the spark channels of negativeand positive-polarity sliding discharges excited in Ne, Ar, and Xe at pressures of 30 and 100 kPa are presented and discussed. It is shown that, depending on the pressure and sort of gas, the averaged optical width of positive-polarity channels is smaller by a factor of 1.27-1.60 than that of negative-polarity channels. The experimental data are analyzed using the theory of propagation of ionization waves with different polarities in gases. Analysis has shown that electron diffusion contributes insignificantly to channel expansion and that, for both polarities, the channel expansion rate exceeds the electron drift velocity in the transverse electric field near the channel. In the framework of the so-called approximation of nonlocalized initial conditions, the measured ratio between of the widths of negativeand positive-polarity channels and their relation to the electron mobility are explained by the channel expansion governed by both electron drift and primary free electrons produced by a short-term source in a narrow region ahead of the front of the expansion wave. Numerical simulations show that the width of this region is comparable with that of the wave front and is more than one order of magnitude smaller than the observed channel radius. Gas photoionization by the channel radiation can serve as a source of primary electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Heuristic Drift-Based Model of the Power Scrape-Off Width in H-Mode Tokamaks

An heuristic model for the plasma scrape-off width in H-mode plasmas is introduced. Grad B and curv B drifts into the SOL are balanced against sonic parallel flows out of the SOL, to the divertor plates. The overall mass flow pattern posited is a modification for open field lines of Pfirsch-Shlüter flows to include sinks to the divertors. These assumptions result in an estimated SOL width of 2aρp/R. They also result in a first-principles calculation of the particle confinement time of H-mode plasmas, qualitatively consistent with experimental observations. It is next assumed that anomalous perpendicular electron thermal diffusivity is the dominant source of heat flux across the separatrix, investing the SOL width, defined above, with heat from the main plasma. The separatrix temperature is calculated based on a two-point model balancing power input to the SOL with Spitzer-Härm parallel thermal conduction losses to the divertor. This results in an heuristic closed-form prediction for the power scrape-off width that is in remarkable quantitative agreement both in absolute magnitude and in scaling with recent experimental data. Further work should include full numerical calculations, including all magnetic and electric drifts, as well as more thorough comparison with experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heuristic Drift-based Model of the Power Scrape-off width in H-mode Tokamaks

An heuristic model for the plasma scrape-off width in H-mode plasmas is introduced. Grad B and curv B drifts into the SOL are balanced against sonic parallel flows out of the SOL, to the divertor plates. The overall particle flow pattern posited is a modification for open field lines of Pfirsch-Shlüter flows to include sinks to the divertors. These assumptions result in an estimated SOL width of ~ 2aρp/R. They also result in a first-principles calculation of the particle confinement time of H-mode plasmas, qualitatively consistent with experimental observations. It is next assumed that anomalous perpendicular electron thermal diffusivity is the dominant source of heat flux across the separatrix, investing the SOL width, defined above, with heat from the main plasma. The separatrix temperature is calculated based on a two-point model balancing power input to the SOL with Spitzer-Härm parallel thermal conduction losses to the divertor. This results in a heuristic closed-form prediction for the power scrape-off width that is in reasonable quantitative agreement both in absolute magnitude and in scaling with recent experimental data from deuterium plasmas. Further work should include full numerical calculations, including all magnetic and electric drifts, as well as more thorough comparison with experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of the top-quark decay width and mass at CDF using the template method.

Measurements of the top quark decay width and mass are presented using the tt events produced in p p collisions at Fermilab's Tevatron collider and collected by the CDF II detector. A data sample corresponding to 4.3 fb -1 of integrated luminosity is used for the top quark width measurement. Two estimators, the reconstructed top quark mass and the mass of hadronically decaying W boson that comes from the top-quark decay are reconstructed for each event and compared with templates of different input top quark widths and deviations from nominal CDF jet energy scale (ΔJES) to perform a simultaneous fit for both parameters. ΔJES is used for the in situ calibration of the jet energy scale at CDF. By applying a Feldman-Cousins limit-setting approach, we establish an upper limit at 95% confidence level (CL) of Γtop < 7.6 GeV and a two-sided 68% CL interval of (0.3 GeV, 4.4) GeV assuming a top quark mass of 172.5 GeV/c 2 , which are consistent with the standard model prediction. The measurement of the top quark mass uses a data sample of tt events in 5.7 fb -1 of integrated luminosity collected by the same detector. Candidate events in the top quark mass measurement are required to have large missing transverse energy, no identified charged leptons, and four, five, or six jets with at least one jet tagged as coming from a b quark. This analysis considers events from the semileptonic tt decay channel, including events that contain tau leptons. The measurement is based on a multidimensional template method, in a similar way to the top quark width measurement, and the top quark mass is measured to be Mtop = 172.32 ± 2.37 ± 0.98 GeV/c 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Point Cloud Based Approach to Stem Width Extraction of Sorghum

A revolution in the field of genomics has produced vast amounts of data and furthered our understanding of the genotypephenotype map, but is currently constrained by manually intensive or limited phenotype data collection. We propose an algorithm to estimate stem width, a key characteristic used for biomass potential evaluation, from 3D point cloud data collected by a robot equipped with a depth sensor in a single pass in a standard field. The algorithm applies a two step alignment to register point clouds in different frames, a Frangi filter to identify stemlike objects in the point cloud and an orientation based filter to segment out and refine individual stems for width estimation. Individually, detected stems which are split due to occlusions are merged and then registered with previously found stems in previous camera frames in order to track temporally. We then refine the estimates to produce an accurate histogram of width estimates per plot. Since the plants in each plot are genetically identical, distributions of the stem width per plot can be useful in identifying genetically superior sorghum for biofuels.

09 BIOMASS FUELS↗

Width of atomic L2 and L3 vacancy states near Z=30.

Results of an investigation of the discontinuity in the L2 level width and the L3-M45M45/L2-M45M45 Auger intensity ratio at Z=30. The afore-mentioned intensity ratio is found to undergo a sudden decrease at Z=30. Relative L2 and L3 level widths of Cu and Zn are derived from photoelectron spectra; while the L3 width increases from Cu to Zn, the L2 width of Cu is greater than that of Zn, contrary to the general trend. The above-mentioned discontinuity is traced to a discontinuity in the Coster-Kronig transition probability f sub 23 predicted in earlier calculations.

Yin, L. I.↗