Search NASA⌕ Search

SEARCH · Search NASA

Results for “WIND GENERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The importance of combined cycle generating plants in integrating large levels of wind power generation

Integration of high wind penetration levels will require fast-ramping combined cycle and steam cycles that, due to higher operating costs, will require proper pricing of ancillary services or other forms of compensation to remain viable. Several technical and policy recommendations are presented to help realign the generation mix to properly integrate the wind. (author)

17 WIND ENERGY↗

Short-Term Frequency Response of a DFIG-Based Wind Turbine Generator for Rapid Frequency Stabilization

This paper proposes a short-term frequency-response scheme of a doubly-fed induction generator (DFIG)-based wind turbine generator (WTG) for improving rotor speed recovery and frequency nadir. In the energy-releasing period, to improve the frequency nadir and rotor speed convergence by releasing a large amount of kinetic energy stored in the rotating masses in a DFIG-based WTG, the power reference is increased up to the torque limit referred to the power and reduces along with it for a predefined period which is determined based on the occurrence time of the frequency nadir in a power grid. Then, the reference decreases so that the rotor speed is forced to be converged to the preset value in the stable operating region of the rotor speed. In the energy-absorbing period, to quickly recover the rotor speed, the reference smoothly decreases with the rotor speed and time during a predefined period until it intersects with the maximum power point tracking curve. The simulation results demonstrate that the proposed scheme successfully achieves rapid frequency stabilization with the improved frequency nadir under various wind conditions based on the IEEE 14-bus system.

17 WIND ENERGY↗

Background and system description of the Mod 1 wind turbine generator

The Mod-1 wind turbine considered is a large utility-class machine, operating in the high wind regime, which has the potential for generation of utility grade power at costs competitive with other alternative energy sources. A Mod-1 wind turbine generator (WTG) description is presented, taking into account the two variable-pitch steel blades of the rotor, the drive train, power generation/control, the Nacelle structure, and the yaw drive. The major surface elements of the WTG are the ground enclosure, the back-up battery system, the step-up transformer, elements of the data system, cabling, area lighting, and tower foundation. The final system weight (rotor, Nacelle, and tower) is expected to be about 650,000 pounds. The WTG will be capable of delivering 1800 kW to the utility grid in a wind-speed above 25 mph.

Ernst, E. H.↗

Utility experience with two demonstration wind turbine generators

Edison has committed 360 MW of nameplate generating capacity to wind energy by year 1990 in its long-range generation plan. To reach this goal the Company's wind energy program focuses on three areas: the continuous evaluation of the wind resource, the hands-on demonstration of wind turbine generators (WTG) and an association with wind park developers. Two demonstration WTGs have been installed and operated at Edison's Wind Energy Center near Palm Springs, California: a 3 MW horizontal axis Bendix/Schachle WTG and a 500 kW vertical axis Alcoa WTG. They are part of a one to two year test program during which the performance of the WTGs will be evaluated, their system operation and environmental impact will be assessed and the design criteria of future WTGs will be identified. Edison's experience with these two WTGs is summarized and the problems encountered with the operation of the two machines are discussed.

Wehrey, M. C.↗

Advanced multimaterial shape optimization methods as applied to advanced manufacturing of wind turbine generators

Abstract Currently, many utility‐scale wind turbine generator original equipment manufacturers are dependent on imported rare earth permanent magnets, which are susceptible to market risks from cost instability. To lower the production costs of these generators and stay competitive in the market, several small wind manufacturers are pursuing continuous improvements to both generator design and manufacturing. However, traditional design and manufacturing methods have yielded marginal improvements in wind power performance. This work presents novel methods to redesign a baseline 15‐kW wind turbine generator with reduced rare‐earth permanent magnets by leveraging cutting‐edge three‐dimensional (3D) printed polymer‐bonded permanent magnets and steel. Symmetric, asymmetric, and multimaterial‐magnet parametrization methods are introduced for shape optimization. We extend the symmetric and asymmetric methods to the back iron in the stator to further investigate the impact and opportunities for performance improvements with lesser active materials. We employ a design‐of‐experiments approach with parametric computer‐aided design for shape generation and evaluate different designs by magneto‐thermal modeling and finite‐element analysis. We use adaptive sampling technique to identify better performing designs with lesser magnet mass, higher efficiency, and lower cogging torque when compared with the baseline generator. Asymmetric pole designs resulted in a magnet mass in the range of 4.77–5.37 kg, which was 27%–35% lighter than the baseline generator, suggesting that a new design freedom exists that can be enabled by advanced manufacturing, such as 3D printing. Shaping the back iron in the stator resulted in material savings in electrical steel of up to 14.62 kg, which was 20% lighter than the baseline stator. We conducted a structural analysis to evaluate an optimized asymmetric rotor design from the point of view of mechanical integrity and air‐gap stiffness. The magnetically optimal shape profile was shown as having a positive impact on the radial stiffness, and an optimal solution was discovered to reduce the structural mass by nearly 30 kg, which was 29% lighter than the baseline.

17 WIND ENERGY↗

Operational-Condition-Independent Criteria Dedicated to Monitoring Wind Turbine Generators: Preprint

To date the existing wind turbine condition monitoring technologies and commercially available systems have not been fully accepted for improving wind turbine availability and reducing their operation and maintenance costs. One of the main reasons is that wind turbines are subject to constantly varying loads and operate at variable rotational speeds. As a consequence, the influences of turbinefaults and the effects of varying load and speed are coupled together in wind turbine condition monitoring signals. So, there is an urgent need to either introduce some operational condition de-coupling procedures into the current wind turbine condition monitoring techniques or develop a new operational condition independent wind turbine condition monitoring technique to maintain high turbineavailability and achieve the expected economic benefits from wind. The purpose of this paper is to develop such a technique. In the paper, three operational condition independent criteria are developed dedicated for monitoring the operation and health condition of wind turbine generators. All proposed criteria have been tested through both simulated and practical experiments. The experimentshave shown that these criteria provide a solution for detecting both mechanical and electrical faults occurring in wind turbine generators.

17 WIND ENERGY↗

Development tests for the 2.5 megawatt Mod-2 wind turbine generator

The 2.5 megawatt MOD-2 wind turbine generator test program is discussed. The development of the 2.5 megawatt MOD-2 wind turbine generator included an extensive program of testing which encompassed verification of analytical procedures, component development, and integrated system verification. The test program was to assure achievement of the thirty year design operational life of the wind turbine system as well as to minimize costly design modifications which would otherwise have been required during on site system testing. Computer codes were modified, fatigue life of structure and dynamic components were verified, mechanical and electrical component and subsystems were functionally checked and modified where necessary to meet system specifications, and measured dynamic responses of coupled systems confirmed analytical predictions.

Andrews, J. S.↗

Wind Turbine Generator System Power Performance Test Report for the ARE442 Wind Turbine

This report summarizes the results of a power performance test that NREL conducted on the ARE 442 wind turbine. This test was conducted in accordance with the International Electrotechnical Commission's (IEC) standard, Wind Turbine Generator Systems Part 12: Power Performance Measurements of Electricity Producing Wind Turbines, IEC 61400-12-1 Ed.1.0, 2005-12. However, because the ARE 442 is a small turbine as defined by IEC, NREL also followed Annex H that applies to small wind turbines. In these summary results, wind speed is normalized to sea-level air density.

17 WIND ENERGY↗

Variable speed generator application on the MOD-5A 7.3 mW wind turbine generator

This paper describes the application of a Scherbiustat type variable speed subsystem in the MOD-5A Wind Turbine Generator. As designed by General Electric Company, Advanced Energy Programs Department, under contract DEN3-153 with NASA Lewis Research Center and DOE, the MOD-5A utilizes the subsystem for both starting assistance in a motoring mode and generation in a controlled airgap torque mode. Reactive power control is also provided. The Scherbiustat type arrangement of a wound rotor machine with a cycloconverter in the rotor circuit was selected after an evaluation of variable speed technologies that followed a system evaluation of drivetrain cost and risk. The paper describes the evaluation factors considered, the results of the evaluations and summarizes operating strategy and performance simulations.

Barton, Robert S.↗

Wind Turbine Generator System Acoustic Noise Test Report for the Gaia Wind 11-kW Wind Turbine

This report details the acoustic noise test conducted on the Gaia-Wind 11-kW wind turbine at the National Wind Technology Center. The test turbine is a two- bladed, downwind wind turbine with a rated power of 11 kW. The test turbine was tested in accordance with the International Electrotechnical Commission standard, IEC 61400-11 Ed 2.1 2006-11 Wind Turbine Generator Systems -- Part 11 AcousticNoise Measurement Techniques.

17 WIND ENERGY↗

Method for predicting impulsive noise generated by wind turbine rotors

Large wind turbines can generate both broad band and impulsive noises. These noises can be controlled by proper choice of rotor design parameters such as rotor location with respect to the supporting tower, tower geometry and tip speed. A method was developed to calculate the impulsive noise generated when the wind turbine blade experiences air forces that are periodic functions of the rotational frequency. This phenomenon can occur when the blades operate in the wake of the support tower and the nonuniform velocity field near the ground due to wind shear. Results from this method were compared with measured sound spectra taken at locations of one to two rotor diameters from the DOE/NASA Mod-1 wind turbine. The calculated spectra generally agreed with the measured data in both the amplitude of the predominant harmonics and the roll of rate with frequency. Measured sound pressure levels far from the Mod-1 (15 rotor diameters), however, were higher than predicted. Simultaneous measurements in the near and far field indicated that the propagation effects could enhance the sound levels by more than 10 dB above that expected by spherical dispersion. These propagation effects are believed to be due to terrain and atmospheric characteristics of the Mod-1 site.

Viterna, L. A.↗

Sound measurements of the MOD-2 wind turbine generator

Sound measurements were made for the MOD-2 wind turbine generator for wind conditions of 7.6 to 13.4 m/sec and for output power ratings of about 1 to 2 NW. Both broad band and narrow band data wre obtained for a range of distances and azimuth angles from the machine. The rotor sound spectra are random in character and peak in the frequency ranges 30 to 50 Hz and 800 to 1300 Hz. Both peaks are predictable from experience with helicopter rotors and propellers. Results suggest that the lower frequency peak is due to the effects of inflow turbulence and the higher frequency peak is due to the interactions of the turbulent boundary layers with the trailing edges of the blades. The boundary layer related sound is the dominant component in the audible frequency range and determines the detectability of the machine. It could be detected at a distance of 1350 m in the upwind direction where the background noise was 30 dB (A) and at distances in excess of 2100 m in the downwind direction. Discrete frequency sound components associated with the power generation equipment are measurable in the direction normal to the axis of rotation but are not believed to be significant for detection or community response.

Hubbard, H. H.↗

Short Circuit Current Contribution for Different Wind Turbine Generator Types

An important aspect of wind power plant (WPP) impact studies is to evaluate the short circuit (SC) current contribution of the plant into the transmission network under different fault conditions. This task can be challenging to protection engineers due to the topology differences between different types of wind turbine generators (WTGs) and the conventional generating units. This paper represents simulation results for short circuit current contribution for different types of WTGs obtained through transient analysis using generic WTG models. The obtained waveforms are analyzed to explain the behavior, such as peak values and rate of decay, of the WTG. The effect of fault types and location, and the effect of the control algorithms of power converters on SC current contribution are investigated. It is shown that the response of the WPP to faults will vary based on the type of the installed WTGs. While in Type 1 and Type 2 WTGs, short circuit current will be determined by the physical characteristics of the induction generator, the contribu-tion of Type 3 and Type 4 WTG will be mostly characterized by the power converters control algorithms which are usually considered proprietary information by the wind turbine manufacturers.

17 WIND ENERGY↗

A theoretical study of the upper bound of surface elevation variance in the Phillips initial stage during wind-wave generation

The resonance mechanism in the initial of wind-wave generation proposed by Phillips is a foundation of wind-wave generation theory, but a precise theoretical quantification of wave energy growth in this initial stage has not been obtained yet after more than six decades of research. In this study, we aim to address this knowledge gap by developing an analytical approach based on a novel complex analysis method to theoretically investigate the temporal evolution of the wave energy in the Phillips initial stage. We quantitatively derive and analyse the growth behaviour of the surface wave energy and obtain an analytical solution for its upper bound. Our result highlights the crucial effects of surface tension. Because the phase velocity of gravity–capillary waves has a minimal value at a critical wavenumber, gravity–capillary waves and gravity waves (which neglect surface tension) exhibit distinct resonance curve properties and wave energy growth behaviours. For gravity waves, the resonance curve extends indefinitely; for gravity–capillary waves, it either forms a finite-length curve or does not exist, depending on the wind speed. The leading-order term of the upper-bound solution of the energy of gravity waves increases linearly over time, while for gravity–capillary waves, the term increases linearly over time under strong wind conditions but remains finite under weak wind conditions. This theoretical study provides an analytical framework for the generation of wind-waves in the Phillips initial stage, which may inspire further theoretical, numerical and experimental research.

58 GEOSCIENCES↗

Preliminary analysis of performance and loads data from the 2-megawatt mod-1 wind turbine generator

Preliminary test data on output power versus wind speed, rotor blade loads, system dynamic behavior, and start-stop characteristics on the Mod-1 wind turbine generator are presented. These data were analyzed statistically and are compared with design predictions of system performance and loads. To date, the Mod-1 wind turbine generator has produced up to 1.5 MW of power, with a measured power versus wind speed curve which agrees closely with design. Blade loads were measured at wind speeds up to 14 m/s and also during rapid shutdowns. Peak transient loads during the most severe shutdowns are less than the design limit loads. On the inboard blade sections, fatigue loads are approximately equal to the design cyclic loads. On the outboard blade sections, however, measured cyclic loads are significantly larger than design values, but they do not appear to exceed fatigue allowable loads as yet.

Spera, D. A.↗