Search NASA⌕ Search

SEARCH · Search NASA

Results for “WORKING FLUID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Study of Standing Pressure Waves Within Open and Closed Acoustic Resonators

The first section of the results presented herein was conducted on an axisymmetric resonator configured with open ventilation ports on either end of the resonator, but otherwise closed and free from obstruction. The remaining section presents the results of a similar resonator shape that was closed, but contained an axisymmetric blockage centrally located through the axis of the resonator. Ambient air was used as the working fluid. In each of the studies, the resonator was oscillated at the resonant frequency of the fluid contained within the cavity while the dynamic pressure, static pressure, and temperature of the fluid were recorded at both ends of the resonator. The baseline results showed a marked reduction in the amplitude of the dynamic pressure waveforms over previous studies due to the use of air instead of refrigerant as the working fluid. A sharp reduction in the amplitude of the acoustic pressure waves was expected and recorded when the configuration of the resonators was modified from closed to open. A change in the resonant frequency was recorded when blockages of differing geometries were used in the closed resonator, while acoustic pressure amplitudes varied little from baseline measurements.

Daniels, C.↗

Bearing development program for a 25 kWe solar-powered organic Rankine-cycle engine

The bearing development program is summarized for a 25-kWe power conversion subsystem (PCS) consisting of an organic Rankine-cycle engine, and permanent magnetic alternator (PMA) and rectifier to be used in a 100-kWe point-focusing distributed receiver solar power plant. The engine and alternator were hermetically sealed and used toluene as the working fluid. The turbine, alternator, and feed pump (TAP) were mounted on a single shaft operating at speeds up to 60,000 rev/min. Net thermal-to-electric efficiencies in the range of 21 to 23% were demonstrated at the maximum working fluid temperature of 400 C (750 F). A chronological summary of the bearing development program is presented. The primary causes of bearing wear problems were traced to a combination of rotordynamic instability and electrodynamic discharge across the bearing surfaces caused by recirculating currents from the PMA. These problems were resolved by implementing an externally supplied, flooded-bearing lubrication system and by electrically insulating all bearings from the TAP housing. This program resulted in the successful development of a stable, high-speed, toluene-lubricated five-pad tilting-pad journal bearing and Rayleigh step thrust bearing system capable of operating at all inclinations between horizontal and vertical.

Nesmith, B.↗

Multi-dimensional modeling of a thermal energy storage canister

The Solar Dynamic Power Module being developed for Space Station Freedom uses a eutectic mixture of LiF-CaF2 phase change material (PCM) contained in toroidal canisters for thermal energy storage. Presented are the results from heat transfer analyses of a PCM containment canister. One and two dimensional finite difference computer models are developed to analyze heat transfer in the canister walls, PCM, void, and heat engine working fluid coolant. The modes of heat transfer considered include conduction in canister walls and solid PCM, conduction and pseudo-free convection in liquid PCM, conduction and radiation across PCM vapor filled void regions, and forced convection in the heat engine working fluid. Void shape, location, growth or shrinkage (due to density difference between the solid and liquid PCM phases) are prescribed based on engineering judgment. The PCM phase change process is analyzed using the enthalpy method. The discussion of the results focuses on how canister thermal performance is affected by free convection in the liquid PCM and void heat transfer. Characterizing these effects is important for interpreting the relationship between ground-based canister performance (in 1-g) and expected on-orbit performance (in micro-g). Void regions accentuate canister hot spots and temperature gradients due to their large thermal resistance. Free convection reduces the extent of PCM superheating and lowers canister temperatures during a portion of the PCM thermal charge period. Surprisingly small differences in canister thermal performance result from operation on the ground and operation on-orbit. This lack of a strong gravity dependency is attributed to the large contribution of container walls in overall canister energy redistribution by conduction.

Kerslake, Thomas W.↗

High temperature heat pipe research at NASA Lewis Research Center

In the course of studies of thermionic power plants for space applications, high-temperature refractory metal heat pipes have been designed and built for alkali metal working fluids. Fabrication of tungsten wire-reinforced tantalum pipes by chemical vapor deposition is discussed; the development of reinforced pipes with integral arteries produced by chemical vapor deposition is also mentioned. The feasibility of using lithium, sodium, potassium, cesium or mercury as the working fluid in the heat pipes is also reviewed. Operation of a lithium-filled heat pipe of about 3-kW capacity for several thousand hours is reported.

Tower, L. K.↗

Leakage Correlation

The allowable leakage rate for space hardware is typically specified as scc/sec of helium. It is important to be able to use the measured helium leakage rate to calculate the expected leakage rate of the working fluid. In this U.S. Spacesuit Knowledge Capture seminar, Dr. Eugene Ungar will explore the physical configuration of typical leak paths, discuss the physics of molecular, transition, and continuum flow, and present the accepted method of conservatively calculating the expected leakage rate of the working fluid.

Ungar, Eugene↗

Intermediate Temperature Ceramic Heat Pipe Modeling and Optimization

Spacecraft nuclear electric propulsion, as well as other emerging technologies, can benefit from heat pipes with optimal performance in the intermediate temperature, 450–700 K, regime. In this work, a 1D model was developed to investigate the performance of halide working fluids coupled with 3D printed-ceramic shells to operate at 500–600 K and interface with a nuclear electric propulsion system. An initial conceptual design and performance limits of a 3D printed-AlN heat pipe radiator with AlBr 3 as the working fluid is presented. An areal density of 5.2 kg/m 2 and mass per unit heat performance of 1.00kg/kW is estimated.

thermal management↗

An Overview of the NASA Ames Millimeter-Wave Thermal Launch System

The Millimeter-Wave Thermal Launch System (MTLS) is a beamed-energy propulsion concept being designed at NASA Ames Research Center. This effort is in response to the NASA Office of the Chief Technologist s announcement of the Ride the Light program. Our objective is to produce a design that goes beyond the feasibility analysis level of previous studies and provides a solid foundation for low cost access to space. The MTLS is designed to place a 500 lb payload into Low Earth Orbit (LEO) two times a day. This frequent launch, small payload niche is well suited for the particular advantages and constraints of beamed-energy propulsion, and has the potential to drastically increase access to space by reducing the cost per kilogram of placing payloads into LEO. This paper summarizes the findings of the MTLS study. The chemical rocket engine is in principle a simple device. It acts by releasing the chemical energy stored in propellants such as hydrogen and oxygen through combustion, then converting that thermal energy into kinetic energy by expansion through a nozzle. As such, it is fundamentally limited by the energy released in combustion reactions and the molecular weight of the products of those reactions. The highest performing conventional propellant combination, liquid oxygen and liquid hydrogen, can produce vacuum specific impulses of around 450 seconds. The design space of current launch vehicles (which tend to be large, multi-stage, and expendable) are defined by these limitations. An entirely new approach may be necessary in order to enable future launch vehicles of radically improved capabilities. Beamed-energy propulsion (BEP) is an alternative approach that bypasses the energy limitations of chemical propulsion. Instead of relying on a chemical reaction as the energy source, it is supplied externally via a beam of electromagnetic energy produced on the ground. In the concept examined in the MTLS, this energy is absorbed by a heat exchanger which then transfers the energy to the propellant. This decouples the energy source from the working fluid, vastly expanding the design space. For example, a launch vehicle could use only water as propellant, making it very safe and easy to handle. However, the most commonly proposed way to take advantage of this decoupling is to use pure hydrogen as the working fluid, which enables specific impulses of around 800 seconds1 if the heat exchanger material can operate at 2200 K. With such a significantly increased Isp, it may be possible to build single-stage to orbit vehicles, with enough mass margins left over to permit lower cost fabrication techniques.

Murakami, David↗

Analytical Investigation of Cycle Characteristics for Advanced Turboelectric Space Power Systems

An investigation was made of the relative influence of turbine inlet temperature, radiator temperature, and turbine efficiency on radiator area for Rankine cycles with rubidium, potassium, and sodium as working fluids. It was determined that, whereas turbine inlet temperature and turbine efficiency have gross effects on radiator size for a given inlet temperature a considerable latitude in the selection of radiator temperature may be accepted with only minor effects on required radiator size. Also investigated was the influence on turbine efficiency and design of the factors that distinguish alkali-metal vapor turbines from conventional gas turbines. The turbine configuration was determined to be a function of the involved working fluids and rotor blade speed. For a given blade speed, the number of stages required for high turbine efficiency was found to vary directly with turbine specific work output, and therefore to vary in the ratio 5 to 2.5 to 1 for sodium, potassium, and rubidium, respectively. Lower blade speeds than employed in conventional gas turbines may be required to satisfy critical stress considerations resulting from the elevated temperatures involved and the criterion of long-duration reliability. This will increase the number of turbine stages necessary to obtain high turbine efficiency and consequently increase turbine weight. The question of moisture formation was discussed and a calculation was made to indicate the nature of the aerodynamic losses due to moisture content. Various means of reducing moisture content were considered, including mechanical removal, increased radiator temperature, inefficient expansion, superheat, and reheat. Sample calculations were made in most cases to indicate their comparative effectiveness and resultant penalty in required radiator area.

Moffitt, Thomas P.↗

Heat Sponge: A Concept for Mass-Efficient Heat Storage

The heat sponge is a device for mass-efficient storage of heat. It was developed to be incorporated in the substructure of a re-entry vehicle to reduce thermal- protection-system requirements. The heat sponge consists of a liquid/vapor mixture contained within a number of miniature pressure vessels that can be embedded within a variety of different types of structures. As temperature is increased, pressure in the miniature pressure vessels also increases so that heat absorbed through vaporization of the liquid is spread over a relatively large temperature range. Using water as a working fluid, the heat-storage capacity of the liquid/vapor mixture is many times higher than that of typical structural materials and is well above that of common phase change materials over a temperature range of 200 F to 700 F. The use of pure ammonia as the working fluid provides a range of application between 432 deg R and 730 deg R, or the use of the more practical water-ammonia solution provides a range of application between 432 deg R and 1160 deg R or in between that of water and pure ammonia. Prototype heat sponges were fabricated and characterized. These heat sponges consisted of 1.0-inch-diameter, hollow, stainless-steel spheres with a wall thickness of 0.020 inches which had varying percentages of their interior volumes filled with water and a water-ammonia solution. An apparatus to measure the heat stored in these prototype heat sponges was designed, fabricated, and verified. The heat-storage capacity calculated from measured temperature histories is compared to numerical predictions.

Splinter, Scott C.↗

Lithium and potassium heat pipes for thermionic converters

A prototypic heat pipe system for an out-of-core thermionic reactor was built and tested. The emitter of the concentric thermionic converter consists of the condenser of a tungsten heat pipe utilizing a lithium working fluid. The evaporator section of the emitter heat pipe is radiation heated to simulate the thermal input from the nuclear reactor. The emitter heat pipe thermal transport is matched to the thermionic converter input requirement. The collector heat pipe of niobium, 1% zirconium alloy uses potassium as the working fluid. The thermionic collector is coupled to the heat pipe by a tapered conical joint designed to minimize the temperature drop. The collector heat flux matches the design requirements of the thermionic converter.

Miskolczy, G.↗

Lithium and potassium heat pipes for thermionic converters

A prototypic heat pipe system for an out-of-core thermionic reactor has been built and tested. The emitter of the concentric thermionic converter consists of the condenser of a tungsten heat pipe utilizing a lithium working fluid. The evaporator section of the emitter heat pipe is radiation heated to simulate the thermal input from the nuclear reactor. The emitter heat pipe thermal transport is matched to the thermionic converter input requirement. The collector heat pipe of niobium, 1%-zirconium alloy uses potassium as the working fluid. The thermionic collector is coupled to the heat pipe by a tapered conical joint designed to minimize the temperature drop. The area ratio of the evaporator to condenser is 16:1, which increases the radiation area. The composite wick structure consists of seven arteries and cylindrical wraps. The collector heat flux matches the design requirements of the thermionic converter.

Miskolczy, G.↗

Modeling of Transient Heat Pipe Operation

The major goal of this project is to develop mathematical models of heat pipes which can be used to predict transient behavior under normal and adverse conditions. The models and solution techniques are to be formulated so that they can be incorporated into existing NASA structural design codes. The major parameters of interest are heat flux distribution, temperature distribution, working fluid pressure distribution, fluid and containment thermal and mechanical properties and geometry. Normal transient operation is taken to be operating conditions where the capillary structure remains fully wetted. Adverse transient operation occurs when drying, re-wetting, choking, non-continuum flow, thawing, freezing, etc., occur in the internal heat pipe working fluid.

Colwell, G. T.↗

Experimental Visualization of Flows in Packed Beds of Spheres

The flow experiment consisted of an oil tunnel, 76 x 76 mm in cross-section, packed with lucite spheres. The index of refraction of the working fluid and the spheres were matched such that the physical spheres invisible to the eye and camera. By seeding the oil and illuminating the packed bed with planar laser light sheet, aligned in the direction of the bulk flow, the system fluid dynamics becomes visible and the 2-D projection was recorded at right angles to the bulk flow. The planar light sheet was traversed from one side of the tunnel to the other providing a simulated 3-D image of the entire flow field. The boundary interface between the working fluid and the sphere rendered the sphere black permitting visualization of the exact locations of the circular interfaces in both the axial and transverse directions with direct visualization of the complex interstitial spaces between the spheres within the bed. Flows were observed near the surfaces of a plane and set of spheres as well as minor circles that appear with great circles and not always uniformly ordered. In addition to visualizing a very complex flow field, it was observed that flow channeling in the direction of the bulk flow occurs between sets of adjacent spheres. Still photographs and video recordings illustrating the flow phenomena will be presented.

Hendricks, R. C.↗

A Liquid-Liquid Thermoelectric Heat Exchanger as a Heat Pump for Testing Phase Change Material Heat Exchangers

The primary objective of the Phase Change HX payload on the International Space Station (ISS) is to test and demonstrate the viability and performance of Phase Change Material Heat Exchangers (PCM HX). The system was required to pump a working fluid through a PCM HX to promote the phase change material to freeze and thaw as expected on Orion's Multipurpose Crew Vehicle. Due to limitations on ISS's Internal Thermal Control System, a heat pump was needed on the Phase Change HX payload to help with reducing the working fluid's temperature to below 0degC (32degF). This paper will review the design and development of a TEC based liquid-liquid heat exchanger as a way to vary to fluid temperature for the freeze and thaw phase of the PCM HX. Specifically, the paper will review the design of custom coldplates and sizing for the required heat removal of the HX.

Sheth, Rubik B.↗

Nuclear Brayton turboalternator-compressor (TAC) conceptual design study

A comprehensive analysis and conceptual design study of the turboalternator-compressor components was performed using HeXe as the working fluid. Individual turbine, alternator, compressor, and bearing and seal designs were evaluated. Six turboalternator-compressor TAC configurations were completed. One TAC configuration was evaluated to calculate its performance when operating under new cycle conditions,namely, one higher and one lower turbine inlet temperature and one case with krypton as the working fluid. Based on the results, a TAC configuration that incorporated a radial compressor, a radial turbine, a Lundell Alternator, and gas bearings was selected. A new layout of the TAC was prepared that reflects the cycle state points necessary to accommodate a zirconium hydride moderated reactor and a 400 Hz alternator. The final TAC design rotates at 24,000 rpm and produces 160 kWe, 480V, 3-phase, 400 hertz power.

Mock, E. A.↗

Turbulent Skin Friction at High Mach Numbers and Reynolds Numbers

For a number of years now, experimenters have been making measurements of skin friction. Formerly, the main interest was at low Mach numbers; later, measurements were made at supersonic Mach numbers. However, almost all of these measurements were over a limited range of Reynolds numbers. On the other hand, these measurements fairly well determined the effects of Mach number and heat transfer on skin friction. The purpose of this paper is to give the results of skin-friction measurements in turbulent boundary layers at high Mach numbers and high Reynolds numbers where data have not previously existed. The equipment used was expressly designed to provide these conditions. As is well known, it is difficult to obtain high Mach numbers and high Reynolds numbers simultaneously with air in a wind tunnel. In order to avoid condensation, it is necessary to heat the air, with a resulting loss in density and Reynolds number. It is desirable, then, to use a gas that does not condense at high Mach numbers. This suggested helium, which was used as a working fluid in some of the tests. At high Mach numbers in a given wind tunnel, higher Reynolds numbers can be obtained with helium than with air, principally because no heating of the helium is required. The different ratios of specific heats also contribute to the increase. In using helium as a working fluid, it is, of course, necessary to determine the equivalence of air and helium in the turbulent boundary layer.

Matting, Fred W.↗

Hall current effects in the Lewis magnetohydrodynamic generator

Data obtained in a magnetohydrodynamic generator are compared with theoretical values calculated by using the Dzung theory. The generator was operated with cesium-seeded argon as the working fluid. The gas temperature varied from 1800 to 2100 K, the gas pressure from 19 to 22 N/sq cm, the Mach number from 0.3 to 0.5, and the magnetic field strength from 0.2 to 1.6 T. The analysis indicates that there is incomplete seed vaporization and that Hall current shorting paths (through the working fluid to ground at both the entrance and exit of the channel) limit generator performance.

Nichols, L. D.↗

Hall current effects in the Lewis magnetohydrodynamic generator.

Data obtained in the Lewis MHD generator are compared with theoretical values calculated using the Dzung (1966) theory. The generator is operated with cesium seeded argon as the working fluid. The gas temperature varies from 1800 to 2100 K, the gas pressure from 19 to 22 N/sq cm, the Mach number from .3 to .5, and the magnetic field strength from .2 to 1.6 tesla. The analysis indicates that there is incomplete seed vaporization and that Hall current shorting paths (through the working fluid to ground at both the entrance and exit of the channel) are limiting generator performance.

Nichols, L. D.↗