Search NASASearch

SEARCH · Search NASA

Results for “Water Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

212 records · Page 9

Scalable slot-die coating of phyllosilicate membranes for selective ion separations

Abstract Two-dimensional (2D) materials have recently drawn attention as candidate materials for molecular-scale membrane separations due to their tunable nanoscale interlayer properties. Phyllosilicates, a broad class of naturally abundant 2D clay minerals, offer significant advantages over synthetic 2D materials, including low cost, stability, and environmental compatibility. While these properties make phyllosilicates attractive for industrial-scale nanofiltration applications, phyllosilicate-based membranes have, to date, only been fabricated at the lab scale via vacuum filtration. Scalable fabrication methods are essential to advance the technical maturity of phyllosilicate membranes and bring these promising materials closer to large-scale adoption. Herein, we have successfully scaled up phyllosilicate (vermiculite) membrane fabrication via slot-die coating and roll-to-roll coating of an ethylenediamine–vermiculite (EDAVM) mixture onto nylon. The coated membranes are 1–2 μm $ \unicode{x03BC} \mathrm{m} $ mu m in thickness and exhibit similar structure and performance to vacuum-filtered EDAVM membranes. The membranes also show selectivity for monovalent ions over multivalent ions in binary salt mixtures. This work represents a major step toward scaling up phyllosilicate membranes for industrial ion separation applications such as resource recovery from water.

Booth, Austin [Princeton University]

Heat metrics and thresholds reshape population exposure and inequality signals

Extreme heat is intensifying worldwide, yet estimates of heat hazard and exposure inequality depend on both the heat metric and how extreme days are defined. Using summer 2022 across the Mediterranean, we quantify population heat exposure with four metrics—land surface temperature (LST), air temperature (Ta), heat index (HI), and wet-bulb globe temperature (WBGT)—under absolute (fixed-value) and relative (anomaly-based) thresholds. Under absolute thresholds, total heat exposure differs by more than two orders of magnitude across metrics (31.3 billion person-days for Ta vs 0.3 billion for HI). Geographic hotspots also diverge: WBGT concentrates in humid coastal North Africa (e.g. the Nile Delta), whereas Ta and LST are more widespread. Under relative thresholds, exposure totals converge and cross-metric hotspot agreement increases (e.g. Ta–WBGT top-tercile overlap increases from 10.7% to 29.0%), shifting hotspots toward densely populated southern Europe. Crucially, the exposure–deprivation relationship also reverses across threshold frameworks: absolute thresholds concentrate exposure in more deprived North Africa and the Middle East, whereas relative thresholds shift the burden toward less-deprived European cities. This sensitivity is decision-relevant: city rankings based on WBGT exposure duration are almost completely reordered when switching threshold frameworks. Threshold choice therefore systematically reshapes hotspot patterns and inequality signals. Reporting both absolute and relative exposures can reveal hidden hotspots and support more targeted heat-risk monitoring and intervention planning.

Mediterranean

Radiolytically reworked Archean organic matter in a habitable deep ancient high-temperature brine

Abstract Investigations of abiotic and biotic contributions to dissolved organic carbon (DOC) are required to constrain microbial habitability in continental subsurface fluids. Here we investigate a large (101–283 mg C/L) DOC pool in an ancient (>1Ga), high temperature (45–55 °C), low biomass (10 2 −10 4 cells/mL), and deep (3.2 km) brine from an uranium-enriched South African gold mine. Excitation-emission matrices (EEMs), negative electrospray ionization (–ESI) 21 tesla Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR MS), and amino acid analyses suggest the brine DOC is primarily radiolytically oxidized kerogen-rich shales or reefs, methane and ethane, with trace amounts of C 3 –C 6 hydrocarbons and organic sulfides. δ 2 H and δ 13 C of C 1 –C 3 hydrocarbons are consistent with abiotic origins. These findings suggest water-rock processes control redox and C cycling, helping support a meagre, slow biosphere over geologic time. A radiolytic-driven, habitable brine may signal similar settings are good targets in the search for life beyond Earth.

Science & Technology - Other Topics

Development of Ternary Transition Metal Oxide Catalysts for Oxygen Evolution Reaction

Electrochemical water splitting, a promising method for green hydrogen production, is currently hindered by the high cost of precious-group metal (PGM)-based catalysts for the oxygen evolution reaction (OER). This study addresses this challenge by advancing the development of catalysts for OER, focusing on the development of high-performance PGM-free catalysts using nickel-iron-cobalt (NiFeCo)-based aerogels. The catalysts were synthesized via a sol-gel method and critical point drying to achieve a highly porous structure with an exceptionally high surface area. The designed catalyst structure provides an ideal platform for maximizing catalytic active sites and enhancing mass transport kinetics. Co has been systematically incorporated into the current PGM-free state-of-the-art, NiFeOx catalyst, and the metal ratios have been optimized. In addition to the experimental studies, density functional theory calculations were performed to study the material’s properties of this ternary catalyst and the effect of Co addition on enhancing OER catalysis.

Mizrahi, Michal [Bar-Ilan University, Ramat Gan, I

Benchmarking of ENDF/B-VIII.1 Thermal Scattering Library for Hydrogen

In correctly characterizing the energy and momentum transfer at thermal and cold energies between neutrons and its interacting medium, thermal scattering libraries, which details energy states due to the intra- and inter-molecular bond effects for the medium materials, are applied in place of free-gas cross section libraries in a particle transport simulation code. They are essential to the neutron performance of a neutron facility like SNS, where thermalized neutrons from 20 K liquid hydrogen and ambient (~300 K) water are transported to the beamlines for neutron scattering experiments in studying materials. Recently, a new version of thermal scattering library for parahydrogen and orthohydrogen at 14-20 K was developed and to be released in ENDF/B-VIII.1. It is, therefore, important to benchmark its impacts on the prediction of moderator performance due to the updates in the thermal scattering library. In this study, the recent ENDF/B-VIII.1 thermal scattering library was compared to the current ENDF/B-VII.1 one in the neutron performance calculations for the decoupled and coupled hydrogen moderators at SNS under theorized and real working conditions. In addition, the predictions using both thermal scattering libraries were benchmarked to the measurements of moderator performance. The consistency between the libraries was observed mostly for parahydrogen and the difference in orthohydrogen at cold neutron energies was noted.

Lu, Wei [Oak Ridge National Laboratory (ORNL), Oak

Treatment of Lagoon Dairy Manure Wastewater via Iron Electrocoagulation, Microfiltration, and Adsorption

Dairy manure wastewater generated by flushing barn cow waste contains nutrients, pathogens, and organic and inorganic contaminants. This study utilized a process consisting of iron electrocoagulation (Fe-EC), microfiltration (MF), and activated carbon (AC) adsorption to treat farm wastewater and explore the reclamation of clean water for irrigation and livestock consumption. Significant removal (>99.9%) of chemical oxygen demand (COD), total organic carbon (TOC), phosphorus (P), turbidity, and microorganisms, as well as ions including magnesium, calcium, sulfur, and silica was achieved by the combined EC-MF-AC process. Specifically, a charge loading of ∼37,500 C/L in a continuous-flow EC configuration, followed by MF, achieved more than 95% removal of TOC and COD. Characterization of produced flocs and foam via scanning-electron microscopy with energy-dispersal spectroscopy and Fourier transform infrared spectroscopy confirmed the removal of ions, including calcium, sulfur, and silica. A key finding was the electrocatalytic conversion of nitrogen species to ammonia gas through the intermediate reduction of nitrate/nitrite, which led to ∼60% total nitrogen (TN) removal. AC treatment further improved TN removal to ∼70%. The Fe-EC process also eradicated >99.9% of bacteria. Preliminary process cost assessment, based on recycled materials for EC electrodes, showed significant cost savings (∼2 times) compared to commercial electrodes.

Dutta, Swapnamoy [ORNL]

Material efficiency technologies in the food and beverage industry

The U.S. food and beverage (F&B) sector is a major contributor to manufacturing gross domestic product and supports substantial employment and economic activity, while exerting significant pressures on land and water resources. At the same time, the industry faces growing expectations to balance its resource-intensive operations without compromising cost competitiveness. Material inefficiencies across the F&B value chain, particularly in raw material use and product loss/waste, lead to substantial financial losses and resource depletion. Thus, the F&B sector requires adoption of solutions and measures to avoid food wastage, reduce raw material consumption and valorize waste to high-value added products. This work presents a comprehensive understanding of the various technology solutions available for the F&B sector. The following two research questions are addressed: “What are the mid-to-high Technology Readiness Level technologies or measures to reduce material use and enable waste valorization in the F&B sector? What are the barriers to their commercial deployment? Additionally, what targeted research and development efforts are needed to overcome these barriers and accelerate their scale-up?” The findings are intended to support evidence-based decision-making, guide strategic investment, and help stakeholders strengthen resilience and competitiveness across the F&B sector.

Nain, Preeti [ORNL] (ORCID:0000000258358959)

Final Technical Report: Transport of Complex Mixtures in Ion-Containing Polymer Membranes

Permselective ion-containing membranes are an integral component for many applications from water treatment, fuel cells, and solar fuels devices where the selective transport of molecules and ions is desired. In solar fuels devices, ion-containing polymer membranes are responsible for permitting selective transport of ions between electrodes to maintain overall charge neutrality yet limit transport of reaction products produced at the electrodes. While the transport of single solutes through such membranes has been fairly well described, binary and multicomponent transport is poorly understood due to the myriad of interactions that occur in these systems (i.e. between co-permeants and between permeants and the membrane). Solar fuels devices are just one example of an application where understanding the transport of multiple simultaneous species is critically important to improving device performance as product crossover leads to reductions in overall device performance. The objectives of this research was to improve our understanding of the complex array of factors that influence transport behavior of multiple solutes within ion-containing polymer membranes. This experimental project addressed the lack of fundamental understanding of multicomponent transport behavior by synthesizing ion exchange membranes with varied incorporation of comonomers (ionic and neutral moieties) to investigate fundamental relationships between membrane structure, membrane physiochemical properties, and transport behavior of solutes and complex solute mixtures through dense, hydrated membranes.

25 ENERGY STORAGE

Studies of laser stimulated photodetachment from nanoparticles for particle charge measurements

Determining nanoparticle charge is more challenging than that for microparticles due to change in the particle size during the synthesis substantial plasma property variations, and difficulties in visualizing individual particles, rendering conventional microparticle charge diagnostics ineffective in dusty plasma. In this work, we utilized laser-stimulated photodetachment (LSPD) to deduce the mean charge of nanoparticles. Nanoparticles were grown in an Ar/C 2 H 2 mixture using a capacitively coupled RF discharge and the LSPD induced changes in the electron current monitored by a cylindrical Langmuir probe. LSPD signals were obtained and analyzed across different dust growth phases. The prolonged decay of electron current pulses was attributed to the presence of residual negative ions, caused by the effective electrostatic trapping of these ions and the potential post—LSPD re-formation of new ones. The particle charge was estimated by combining the laser-stimulated photodetachment signal from the probe with the dust density obtained from laser-light extinction using the measured nanoparticle size distribution. For a nanoparticles size range of approximately 100–250 nm and mean diameter of $d$ p ∼154.37 nm, the effective mean charge was estimated to be $\langle$$Q$$\rangle$ d $≈$ 37 elementary charge units. The measured charge values are lower than those predicted by orbital motion limited theory, which may be attributed to significant electron depletion in the nanodusty plasma. LSPD results in Ar/C 2 H 2 nano-dusty plasma confirm the applicability of this method for estimating individual nanoparticle charges. However, it has also been demonstrated that electron detachment from residual background negative ions can influence the detachment current decay and must be carefully considered.

dust particle charge

Amazonian fog harbors viable microbes

Fog formation over tropical forests remains poorly characterized, despite its potential role in bioaerosol dispersion and ecosystem processes. Here, we analyzed fog samples collected at the Amazon Tall Tower Observatory using flow cytometry and culture-based techniques to characterize viable microbial communities. Microbial cell concentrations varied over an order of magnitude across 13 fog events, reaching up to 8 × 104 cells per ml of fog water. Flow cytometry consistently detected metabolically active cells, while culturing and mass spectrometry-based identification yielded eight viable bacterial species and seven fungal taxa. The bacteria Serratia marcescens, Ralstonia pickettii and Sphingomonas paucimobilis exhibited seasonal variations in prevalence. The fungal species identified were primarily mesophilic saprophytes and endophytes, commonly associated with soil and plant surfaces. Our findings indicate that fog harbors viable microbes, including Serratia marcescens and Ralstonia pickettii, which may imply a relevance of fog for microbial dispersal, colonization and nutrient cycling in the Amazon rainforest.

Godoi, Ricardo H. (ORCID:0000000247744870)

A stable high-humidity bubbler design to supply steam for solid oxide electrolysis cells

A stable steam supply is required for the operation of solid oxide electrolysis cells. Heated water bubblers are the most common method due to the simplicity and inherent safety of the method, however, several design challenges hinder effective implementation. Here, a stable and validated bubbler design is presented, capable of achieving very high steam concentrations, relatively high flow rates, and continuous operation. A piping and instrumentation diagram and bill of materials are provided to enable easy duplication. Critical design parameters are discussed, including safety considerations and materials requirements, which are applicable to any bubbler design. The practical implementation of bubblers is also presented, including methods to prevent condensation instability and reduce backpressure to achieve a stable steam supply. The 3″ x 6″ (7.6 cm × 15.2 cm) bubbler achieves up to 98% steam balance hydrogen at 200 sccm and up to 1 slpm at 96% steam.

08 - HYDROGEN

Crustal Deformation and Gravitational Effects From Dynamic Ocean Mass Redistribution Impact Projected Sea‐Level Change

As the climate warms, associated changes in ocean dynamics will redistribute sea‐water mass within the ocean, contributing to relative sea‐level change. This mass redistribution will cause additional sea‐level changes due to gravitational self‐attraction, deformation of the solid Earth, and shifts in the Earth's rotation axis (GRD), which are not incorporated in sea‐level projections. Using CMIP6 climate model output, we quantify relative sea‐level changes induced by GRD from ocean‐dynamic mass loading through 2100. These effects act to amplify projected ocean‐dynamic sea‐level patterns, causing sea‐level rise in coastal regions, particularly along wide continental shelves and at high latitudes. On average, the magnitude of such GRD‐induced sea‐level change is equivalent to ∼15% of the signal due to dynamic ocean mass redistribution. Although our results show substantial inter‐model spread, they reveal that GRD‐induced relative sea‐level changes from ocean mass redistribution represent a non‐negligible component of regional sea‐level change and should be considered in projections.

58 GEOSCIENCES

Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering

Characterizing and modeling the mechanical behavior of an anion exchange membrane for carbon capture applications

A new direct air capture (DAC) technology uses a moisture swing (MS) process with anion exchange membranes, potentially offering a more energy-efficient way to remove CO₂ from the air. In this MS process, the membrane absorbs CO₂ as it dries and releases it when water is added. Understanding the mechanical behavior of these membranes is essential for improving the design and efficiency of DAC systems and prolonging sorbent lifetime. This study tested one anion exchange membrane, Fumasep’s FAA-3, under mechanical loading and various temperature and humidity conditions to measure its swelling, stiffness, strength, plastic deformation, and stress relaxation. Experimental results were used to identify a mechanical model for FAA-3 that can be used to predict the material’s nonlinear viscous behavior under various loads and environments. Unlike prior studies that assumed linear elastic behavior, this work incorporates humidity-dependent swelling, thermal expansion, and nonlinear viscoelasticity of FAA-3 in both the experiments and the model.

Direct air capture

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN

Carbon Tetrachloride Degradation Results for 200-ZP-1 Operable Unit

Carbon tetrachloride (CT) contamination in the 200-ZP-1 Operable Unit (OU) at the Hanford Site originated from large-volume discharges to the subsurface during plutonium production operations between 1955 and 1973. Contamination migrated through more than 70 meters of unsaturated sediment to reach the underlying unconfined aquifer, where it persists as a large and complex groundwater plume. The 200-ZP-1 OU Record of Decision (ROD) requires that groundwater CT concentrations be reduced to 3.4 µg/L within 125 years. Current groundwater modeling projections estimate that the existing pump-and-treat, even when combined with monitored natural attenuation (specifically hydrolysis), will not achieve this target within the designated timeframe. A fundamental contributor to this shortfall is the extremely slow rate of CT hydrolysis under Hanford aquifer conditions, which has been estimated to have a half-life of 630 years. If faster-acting biotic and abiotic degradation processes are operating within the aquifer, their contribution to CT mass reduction could have a meaningful impact. However, site-specific measurements of these processes and their rates have not previously been performed. This report documents the results of a two-phase laboratory investigation designed to characterize and quantify the capacity of site-specific 200-ZP-1 OU sediments and groundwater to support natural attenuation of CT through biotic and abiotic pathways. In this context, degradation capacity is defined as the intrinsic potential of the subsurface matrix to transform CT under optimized, controlled conditions. System capacity is evaluated in two ways: (1) as rate-limited capacity, which establishes the maximum kinetic velocity of CT transformation and is measured using half-lives and first order rate constants; and (2) as mass limited capacity, which defines the total contaminant mass the batch experimental system can degrade before reactants are exhausted, representing the maximum amount of contaminant the microbial community and reactive mineral phases can transform under the experimental conditions.

abiotic degradation

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS

Multi-contrast machine learning improves schistosomiasis diagnostic performance

Schistosomiasis currently affects over 250 million people and remains a public health burden despite ongoing global control efforts. Conventional microscopy is a practical tool for diagnosis and screening ofSchistosoma haematobium, but identification of eggs requires a skilled microscopist. Here we present a machine learning (ML)-based strategy for automated detection ofS. haematobiumthat combines two imaging contrasts, brightfield (BF) and darkfield (DF), to improve diagnostic performance. We collected BF and DF images of urine samples, many of them containingS. haematobiumeggs, during two different field studies in Côte d’Ivoire using a mobile phone-based microscope, the SchistoScope. We then trained separate egg-detection ML models and compared the patient-level performance of BF and DF models alone to combinations of BF and DF models, using annotations from trained microscopists as the gold standard. We found that models trained on DF images, and almost all BF and DF combinations, performed significantly better than models trained on BF images only. When models were trained on images from the first field study (n = 349 patients, 748 images of each contrast), patient-level classification performance on patient images from the second study (n = 375 patients, 752 images of each contrast) met the WHO Diagnostic Target Product Profile (TPP) sensitivity and specificity for the monitoring and evaluation use case (sensitivity for all models and combinations was >75% when evaluated at a confidence score threshold that resulted in specificity >96.5%). When we used images from both field studies for the training set, performance of the models was improved. Overall, this work shows that the use of DF and BF increases the performance of ML models on images from devices with low-cost optics, while retaining the portability, power, and time-to-results of the WHO’s diagnostic TPP. DF requires no additional sample preparation and does not increase the complexity of the imaging system. It thus offers a practical means to improve performance of automated diagnostics forS. haematobiumas well as other microscopy-based diagnostics.

Infectious Diseases