Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

Evolution of Metastable Phases During Mg Metal Corrosion: An In Situ Cryogenic X-ray Photoelectron Spectroscopy Study

Magnesium and its alloys are potential structural materials candidates for a wide variety of applications due to their high strength-to-weight ratio. However, ductility and poor corrosion resistance under ambient environmental conditions are the bottleneck for industrial deployment. Designing passivation layers and/or corrosion resistant alloys requires fundamental understanding of the corrosion process. The traditional ex-situ spectroscopic measurements of polycrystalline metal surface with ubiquitous surface impurities and grain boundaries only provided an indistinct view of the corrosion process. To clearly distinguish the mechanism and sequence of corrosion process, we employed in-situ cryo-based x-ray photoelectron spectroscopy (XPS) measurements on Mg single crystal surface exposed to aqueous salt solution. Clean Mg (0001) surfaces were exposed to pure D2O and NaCl aqueous solution (5 wt% NaCl+95 wt% D2O). The interfacial reactions were studied using multimodal analysis including XPS, x-ray diffraction (XRD) and scanning electron microscopy (SEM). In contrast to previous studies, our experiments demonstrated the formation of magnesium chloride hydroxide hydrate during aqueous salt corrosion processes. Evidence of metastable ClO* radicals were also found during the initial aqueous salt solution exposure.

Shutthanandan, Vaithiyalingam↗

Quantitative measurements of density in shock-compressed silver up to 330 GPa using x-ray diffraction

This work presents a structural study of shock-compressed states in Ag to 331 GPa, accessed via laser shock compression. Structures of the resulting crystalline phases and the average atomic distribution of the liquid state are determined using in situ x-ray diffraction. We employ structure factor analysis, adapted for a non-monochromatic x-ray source, to determine the density of the liquid phase from analysis of x-ray diffraction data for the first time in shock compressed Ag. We also present a detailed analysis of the crystalline phases, which shows good agreement with the phase boundaries reported in previous experimental and theoretical works. We utilize the whole powder pattern fitting approach implemented in the MAUD package to constrain stacking faults in the face centered cubic structure. We observe the ambient fcc structure up to a stress of 146 GPa before a transition to a body-centered cubic structure and liquid phase at 179 GPa, with full melting above 212 GPa.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray free electron laser heating of water and gold at high static pressure

Probing of reactive materials such as H 2 O ices and fluids at the high pressures and temperatures of planetary interiors is limited by unwanted chemical reactions and confinement failure. Faster experiments can mitigate such issues, but the common approach of adiabatic compression limits the conditions achieved. This study demonstrates a fast experimental strategy for the creation and probing of selected extreme states using static compression coupled with ultrafast X-ray laser heating. Indirect X-ray heating of H 2 O through the use of a gold absorber is evidenced by sample melting inferred from textural changes in the H 2 O diffraction lines and inter-dispersion of gold and H 2 O melts. Coupled with numerical analysis of femtosecond energy absorption, thermal equilibration, and heat transfer, all evidence indicates that temperatures in excess of an electron volt have been reached in the H 2 O at high pressure. Even after repeated heating, samples stayed chemically unchanged from the starting material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II

In this work, we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.

36 MATERIALS SCIENCE↗

Atomic-Site-Specific Surface Valence-Band Structure from X-Ray Standing-Wave Excited Photoemission

X-ray standing-wave (XSW) excited photoelectron emission was used to measure the site-specific valence band (VB) for ½ monolayer (ML) Pt grown on a SrTiO 3 (001) surface. The XSW induced modulations in the core level (CL), and VB photoemission from the surface and substrate atoms were monitored for three ℎ⁡kl substrate Bragg reflections. The XSW CL analysis shows the Pt to have a face-centered-cubic-like cube-on-cube epitaxy with the substrate. The XSW VB information compares well to a density functional theory calculated projected density of states from the surface and substrate atoms. Altogether, this Letter represents a novel method for determining the contribution to the density of states by valence electrons from specific atomic surface sites.

74 ATOMIC AND MOLECULAR PHYSICS↗

In Situ X-ray Diffraction of High Density Polyethylene During Dynamic Compression: Polymer Chain Compression and Phase Transformations

Polymers are widely implemented materials often used for safety and security in our daily lives. However, we do not have a thorough understanding of the phase transformations of these materials when exposed to extreme condition, high strain rate, events. To study polymers in these severe environments, we performed plate impact experiments that impart a one-dimensional shock wave, at high pressures and temperatures, to observe the materials response. Generally, velocimetry is the experimental diagnostic used to capture the movement of high velocity interfaces to then calculate the mechanical variables associated with shock compression. However, when a material undergoes a phase transition, such as between two crystalline phases or melting to decomposition during shock compression, velocimetry does not explicitly indicate what structural change occurred. At the Dynamic Compression Sector at the Advanced Photon Source gas gun driven compression has been paired with x-ray diffraction, providing the ability to study both the shock parameters and structural changes concurrently. We explored high density polyethylene (HDPE) both on its reactants Hugoniot (<10.12 GPa) and within its transition region (24.3 GPa) where HDPE is hypothesized to decompose from reactants to products. With x-ray diffraction we observed both polymer chain compression and crystal structure reorientation from orthorhombic to monoclinic above 6 GPa, as well as either a possible phase change or chemical decomposition at 24.3 GPa. With these experiments we were able to determine the crystalline and amorphous Hugoniot loci at pressures below the polymer transition region.

36 MATERIALS SCIENCE↗