Search NASA⌕ Search

SEARCH · Search NASA

Results for “Xenon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Evidence of charge exchange pumping in calcium-xenon system

A flowing xenon plasma seeded with calcium was used to investigate the population mechanism for the 5s and 4d levels of Ca(+). From the dependence of certain line intensity ratios on electron temperature it was concluded that charge exchange between Xe(+) and Ca is the predominate mechanism for populating the 5s and 4d levels. Comparison with intensity ratios obtained in Ca-Ar and Ca-Kr imply the same conclusion.

Chubb, D. L.↗

Near-threshold photoionization of xenon metastable atoms

Photoionization from metastable levels of atomic xenon has been studied in the wavelength range from the threshold at 4622 A to 2700 A. Structure in the photoionization signal, due to autoionization, is analyzed to provide term values, lifetimes, and line-shape parameters of the autoionizing states. These parameters, together with the estimated absolute cross sections, are used to derive discrete and continuum oscillator strengths.

Rundel, R. D.↗

Graphite and ablative material response to CO2 laser, carbon-arc, and xenon-arc radiation

The behavior was investigated of graphite and several charring ablators in a variety of high-radiative heat-flux environments. A commercial-grade graphite and nine state-of-the-art charring ablators were subjected to various radiative environments produced by a CO2 laser and a carbon arc. Graphite was also tested in xenon-arc radiation. Heat-flux levels ranged from 10 to 47 MW/sq m. Tests were conducted in air, nitrogen, helium, and a CO2-N2 mixture which simulated the Venus atmosphere. The experimental results were compared with theoretical results obtained with a one-dimensional charring-ablator analysis and a two-dimensional subliming-ablator analysis. Neither the graphite nor the charring ablators showed significant differences in appearance or microstructure after testing in the different radiative environments. The performance of phenolic nylon and graphite was predicted satisfactorily with existing analyses and published material property data. Good agreement between experimental and analytical results was obtained by using sublimation parameters from a chemical nonequilibrium analysis of graphite sublimation. Some charring ablators performed reasonably well and could withstand radiative fluxes of the level encountered in certain planetary entries. Other materials showed excessive surface recession and/or large amounts of cracking and spalling, and appear to be unsuitable for severe radiative environments.

Brewer, W. D.↗

A theoretical investigation of isotopic anomalies of xenon in terrestrial and extra-terrestrial samples

The abundance and isotopic composition of noble gases in meteorites is discussed in relation to the composition of the early solar system. Carbonaceous chondrites contain a unique Xenon-X, which is rich in heavy and light isotopes. Variations in the occurrence of type-X and type-Y (the normal component) noble gases are of such magnitude that neither the injection of material from a nearby supernova nor presence of presolar grains can account for the anomalies in meteorites. Therefore, it is suggested that the entire solar system may have condensed from the debris of a single local supernova.

Sabu, D. D.↗

Krypton and xenon in Apollo 14 samples - Fission and neutron capture effects in gas-rich samples

Gas-rich Apollo 14 breccias and trench soil are examined for fission xenon from the decay of the extinct isotopes Pu-244 and I-129, and some samples have been found to have an excess fission component which apparently was incorporated after decay elsewhere and was not produced by in situ decay. Two samples have excess Xe-129 resulting from the decay of I-129. The excess is correlated at low temperatures with excess Xe-128 resulting from neutron capture on I-127. This neutron capture effect is accompanied by related low-temperature excesses of Kr-80 and Kr-82 from neutron capture on the bromine isotopes. Surface correlated concentrations of iodine and bromine are calculated from the neutron capture excesses.

Drozd, R.↗

s-process studies - Xenon and krypton isotopic abundances

We propose an analysis of the s-process contributions to the isotopes of xenon and krypton. The object is to aid studies of the possibility that meteorites may contain gas that was carried in presolar grains that were grown in stellar ejecta and that were not degassed prior to incorporation into parent bodies. That model suggests routine interstellar fractionation of s-isotopes from r-isotopes owing to differential incorporation into dust. We show that a deficiency of s-process nuclei cannot yield details of Xe-X, but the gross similarities are strong enough to lead one to think that such a deficiency may play a role in a more complicated explanation. We predict the existence of an s-rich complement somewhere if fractional separation of this type has played a role in Xe-X. We show that the analogous decomposition of krypton is more uncertain, and we call for measurements of neutron-capture cross sections to alleviate these uncertainties.

Clayton, D. D.↗

Laser excited fluorescence in the cesium-xenon excimer and the cesium dimer

Argon ion laser lines are used to excite fluorescence in a mixture of cesium and xenon. Excimer band fluorescence is observed at higher pressures (about 1 atm) while at lower pressures (several torr) a diffuse fluorescence due to the cesium dimer is observed whose character changes with exciting wavelength. The excimer fluorescence is shown to be directly related to the location of the exciting wavelength within previously measured Cs/Xe line shapes. This fact suggests that the excimer systems may be efficiently pumped through these line shapes. Qualitative energy-level schemes are proposed to explain the observations in both the excimer and dimer systems.

Exton, R. J.↗

Absorption and resonance Raman spectra of Pb2, Pb3 and Pb4 in xenon matrices

Lead metal was vaporized and trapped in solid xenon at 12K. Electronic absorption and resonance Raman spectra were recorded of the resulting matrix, which was shown to contain Pb2, Pb3, and possibly Pb4 molecular species. The vibrational frequency for Pb2 is determined to be 108/cm for the ground state, with a dissociation energy of 82000/cm. Ad3h symmetry is indicated for the Pb3 species, with nu sub 1=117/cm and nu sub 2 = 96 /cm. The existence of Pb4 is suggested by a fundamental and overtone of 111/cm spacing.

Stranz, D. D.↗

Absorption and resonance Raman spectra of Pb2, Pb3, and Pb4 in xenon matrices

Matrix isolation techniques are used to investigate the spectra of lead molecules and, in particular, to obtain resonance Raman spectra of lead vapors isolated in solid xenon matrices. The presence of Pb2 is confirmed by the visible adsorption, and Raman spectra yield a vibrational frequency for the ground state of 108 per cm and a dissociation energy of 8200 per cm. A second resonance Raman progression indicates a Pb3 species of D3h symmetry. Finally, two additional Raman features at approximately 111 per cm spacing are evidence for a third species, tentatively identified as Pb4.

Stranz, D. D.↗

Krypton and xenon in the atmosphere of Venus

The paper reports a determination by the Pioneer Venus large probe neutral mass spectrometer of upper limits to the concentration of krypton and xenon along with most of their isotopes in the atmosphere of Venus. The upper limit to the krypton mixing ratio is estimated at 47 ppb, with a very conservative estimate at 69 ppb. The probable upper limit to the sum of the mixing ratios of the isotopes Xe-128, Xe-129, Xe-130, Xe-131, and Xe-132 is 40 ppb by volume, with a very conservative upper limit three times this large.

Donahue, T. M.↗

Isotopically anomalous xenon in meteorites - A new clue to its origin

The CCF xenon component in primitive meteorites, which has been attributed either to fission of a superheavy element or to nucleosynthesis in a supernova, does not show the large enrichment in Xe-129 (from decay of 16 Myr I-129) expected for supernova ejecta. Although this problem can be circumvented by ad hoc assumptions, a fission origin of CCFXe seems more likely.

Lewis, R. S.↗

Relativistic rise measurement for heavy cosmic rays in xenon

Potential advantages of the use of the relativistic rise of energy loss in gas-filled counters for cosmic ray energy measurement have been noted by Tueller et al. (1979) and Gregory and Parnell (1979). Gregory and Parnell have reported measurements on the relativistic rise for cosmic ray iron nuclei in parallel plate ionization chambers 8.4 cm thick filled with a xenon and methane mixture. The present investigation is concerned with the observed rise and ionization signal fluctuations for a sample of elements from carbon through iron in the cosmic rays. The results are compared with a calculation of the energy deposit within the ion chamber.

Gregory, J. C.↗

Performance capabilities of the 12-centimeter Xenon ion thruster

The 8- and 12-cm mercury ion thruster systems were developed primarily to provide N-S station keeping of satellites with masses up to about 1800 to 3600 kg respectively. The on-orbit propulsion requirements of recently proposed Large Space Systems (LSS) are beyond the thrust capabilities of the baseline 8- and 12-cm thruster systems. This paper presents a characterization of the performance capabilities of the 12-cm Xenon ion thruster to enable an evaluation of its application to LSS auxiliary propulsion requirements. With minor thruster modifications and simplifications the thrust was increased to 64 mN, a factor of six over the baseline 12-cm mercury thruster performance. The thruster was operated over a range of specific impulse of about 2000 to 4000 seconds and at total efficiencies up to 68.0 percent. The operating levels reached in this study were found to be close to the operating limits of the thruster design in terms of perveance, grid breakdown voltage and thruster component temperatures such as those of the magnets and cathode baffle.

Mantenieks, M.↗

Ultranarrow linewidth, magnetically switched, long pulse, xenon chloride laser

A spectral linewidth of less than 70 fm and diffraction-limited beam divergence have been obtained from a long-pulse, electric-discharge xenon chloride laser with intracavity Fabry-Perot etalons. A gain duration of 100 ns provided for multipass operation of the etalons, significantly improving both contrast and finesse. The electrical-discharge circuit required to produce this long gain duration was comprised of a pulse-forming network, a saturable-inductor magnetic switch, and a tapered constant-impedance interface transmission line.

Pacala, T. J.↗

Performance capabilities of the 12-centimeter Xenon ion thruster

The 8- and 12-cm mercury ion thruster systems were developed primarily to provide N-S station keeping of satellites with masses up to about 1800 to 3600 kg respectively. The on-orbit propulsion requirements of recently proposed Large Space Systems (LSS) are beyond the thrust capabilities of the baseline 8- and 12-cm thruster systems. This paper presents a characterization of the performance capabilities of the 12-cm Xenon ion thruster to enable an evaluation of its application to LSS auxiliary propulsion requirements. With minor thruster modifications and simplifications the thrust was increased to 64 mN, a factor of six over the baseline 12-cm mercury thruster performance. The thruster was operated over a range of specific impulse of about 2000 to 4000 seconds and at total efficiencies up to 68.0 percent. The operating levels reached in this study were found to be close to the operating limits of the thruster design in terms of perveance, grid breakdown voltage and thruster component temperatures such as those of the magnets and cathode baffle.

Mantenieks, M.↗

Trapping of xenon in ice - Implications for the origin of the earth's noble gases

Although the earth's atmosphere contains Ne, Ar, and Kr in about C1,2-chondrite proportions, Xe is depleted about 20-fold. To test the suggestion that the 'missing' Xe is trapped in Antarctic ice, distribution coefficients for Xe in artifically formed frost at -20 to -60 C were measured, using Xe-127 tracer. The values are 0.098 + or - 0.004 cc STP/g atm for trapping and less than 5 cc STP/g atm for trapping plus adsorption. If these results are representative of natural ice, then the Antarctic ice cap contains less than 1 percent of the atmospheric Xe inventory, or not greater than about 0.001 the amount needed for a C1,2-chondrite pattern. Two possibilities remain for the 'missing' Xe, both on the premise that the earth's noble gases, along with other volatiles, came from chondritic material: (1) xenon is preferentially retained in the mantle and lower crust, due to the strong affinity of Xe for clean silicate surfaces and amorphous carbon; and (2) the source material of the earth's volatiles had high, relatively unfractionated, Ar/Xe and Kr/Xe ratios, like the non-carbonaceous noble gas carriers in C3O and E-chondrites.

Wacker, J. F.↗

Etching Silicon Films With Xenon Difluoride

Microscopic circuit structures prepared for probing. Xenon difluoride removes relatively large amounts of silicon from integratedcircuit or solar-cell structures while leaving SiO2, Si3N4, Al2O3, and other compounds intact. In Etching Apparatus, solid XeF2 sublimated in vacuum, then allowed to flow over sample at controlled rate and pressure. Wafer etched from back to expose SiO2 and Al layers for spectroscopic analysis of SiO2/Al interface. Using XeF2 technique, silicon wafer with oxide layer reduced in thickness from standard 300 micrometer to as little as 10 nanometer without adversely affecting oxide.

Hecht, M. H.↗

Xenon-Ion Drilling of Tungsten Films

High-velocity xenon ions used to drill holes of controlled size and distribution through tungsten layer that sheaths surface of controlled-porosity dispenser cathode of traveling wave-tube electron emitter. Controlled-porosity dispenser cathode employs barium/calcium/ aluminum oxide mixture that migrates through pores in cathode surface, thus coating it and reducing its work function. Rapid, precise drilling technique applied to films of other metals and used in other applications where micron-scale holes required. Method requires only few hours, as opposed to tens of hours by prior methods.

Garner, C. E.↗