Search NASA⌕ Search

SEARCH · Search NASA

Results for “absorbed power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Cold compressor performance and energy consumption improvements at Jefferson Lab’s Central Helium Liquefiers

Abstract Jefferson Lab operates two central helium liquefiers (CHLs) which both utilize full cold compression from the saturation pressure at operating temperature (approximately 2.1 K) to just over atmospheric pressure. The original plant, CHL1, was recently outfitted with a replacement subatmospheric cold box (SC1R) containing state-of-the-art cold compressor technology, while the newer plant, CHL2, uses an older cold compressor system. In both cases, the heat of compression is absorbed at low temperature at the expense of electrical power consumed by the warm compressors. Due to the superior efficiency and turndown capabilities of SC1R, a new operating mode has been identified for CHL1 in which the required number of operating warm compressors is reduced by one. A cost-based method for optimizing cold compressor stability and efficiency has been developed and applied to CHL2, improving its turndown and lowering the warm compressor discharge pressure. As a result of these efforts, power consumption of the combined CHLs during normal operations has been reduced by nearly 10%, or a total of 650 kW. The observed performance of CHL1 with SC1R, as well as the cold compressor optimization method, leading to this improved energy consumption rate will be discussed in detail.

Mastracci, B [Thomas Jefferson National Accelerato↗

Performance and Regulation of Photosystem II Energy Conversion in Oxygenic Phototrophs: From PSII Crystals to Living Cells

New information not previously accessible to answer remaining questions about the mechanism of PSII catalyzed water oxidation, its intrinsic inefficiencies and the regulation of PSII in living cells were obtained. This effort was done in collaboration with an expert in PSII crystallography (led by Prof. Petra Fromme, ASU). We applied a set of tools for fluorometric, oximetric, potentiometric and absorbance measurements. Transformational knowledge from PSII crystals and a powerful new fluorescence technique were developed. Three aims were addressed and 18 peer-reviewed publications were generated.

59 BASIC BIOLOGICAL SCIENCES↗

IPL-Annealed Mixed-Cation Perovskites with Robust Coating Window toward Scalable Manufacturing of Commercial Perovskite Solar Cells

Perovskite solar cells (PSCs) are a promising alternative solar technology, but the technical challenges of (1) stability/durability, (2) efficiency at scale, and (3) manufacturability must be overcome to achieve widespread PSC commercialization. The challenge of balancing solution ink formulation and scalable manufacturing is often overlooked in the literature, where focus is on adopting inks from processes that will not scale. In this study, we apply a classical roll-to-roll manufacturing perspective, utilizing both compositional engineering and intense pulsed light (IPL) annealing, to develop a mixed-cation perovskite ink with a robust coating window that simultaneously solve issues of stability and manufacturability for PSCs. Our method resulted in blade-coated, flexible, mixed-cation PSCs on ITO-PET substrates with a champion power conversion efficiency (PCE) efficiency of 16.7% using IPL annealing of the absorber layer and, to our knowledge, is one of the fastest processing methods for the perovskite layer. This overall reduction in processing time with a stable ink represents an advance toward the scaled production of perovskite solar cells on flexible substrates.

flexible perovskite solar cells↗

Designing Dynamic Wireless Power Transfer Corridors for Heavy Duty Battery Electric Commercial Freight Vehicles

The use of wireless power transfer systems, consisting of inductive electrical coils on the vehicle and the power source may be designed for dynamic operations where the vehicle will absorb energy at highway speeds from transmitting coils in the road. This has the potential to reduce the onboard energy storage requirements for vehicles while enabling significantly longer missions. This paper presents an approach to architecting a dynamic wireless power transfer corridor for heavy duty battery electric commercial freight vehicles. By considering the interplay of roadway power capacity, roadway and vehicle coil coverage, seasonal road traffic loading, freight vehicle class and weight, vehicle mobility energy requirements, on-board battery chemistry, non-electrified roadway vehicle range requirements, grid capacity, substation locations, and variations in electricity costs, we minimize the vehicle TCO by architecting the electrified roadway and the vehicle battery simultaneously. The idea optimizes battery size and chemistry so that the depth of discharge between recharge events and expected life are balanced, thus fully utilizing the energy available throughout the course of the battery system's life. The approach is illustrated by applying it to the I-75 freight corridor, where the framework developed may be expanded and applied to a larger interstate system, expanded regional corridor, or other transportation network.

Sujan, Vivek↗

SPC-70773 Rev 0 MARVEL Central Insurance Absorber Gray Rod Build to Print Specification

A. Idaho National Laboratory (INL) is developing a microreactor to produce electrical power utilizing a small nuclear core and Stirling engines under the Microreactor Application Research Validation and Evaluation (MARVEL) program. This procurement specification defines the requirements for fabrication of the Central Insurance Absorber Structure (CIAS) Gray Rod (Hafnium). B. Any conflict between this specification and referenced Codes and Standards, or any supplementary specifications in the procurement documents requires written clarification from the Contractor prior to proceeding with any work. Any deviation from the procurement documents requires approval by the Contractor with the change request process.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗

Highly efficient small molecule multi-junction organic photovoltaic cells

A highly efficient multi junction photovoltaic device, such as a two, three, or four junction device, is disclosed. The multi-junction device may include a first subcell comprising a first photoactive region and a second subcell comprising a second photoactive region. The first and second photoactive regions are designed to minimize spectral overlap and maximize photocurrent across a broad absorption spectra, such as wavelengths ranging from 400 nm to 900 nm. The device may further include an inter-connecting layer, disposed between the first subcell and the second subcell, that is at least substantially transparent. By introducing a transparent interconnecting layer, a dual element (tandem) cell achieves a power conversion efficiency of 10.0±0.5%. By adding an additional (3rd) sub-cell that absorbs at the second order optical interference maximum within the stack. The triple junction cell significantly improves the quantum efficiency at shorter wavelengths, achieving a power conversion efficiency of 11.1±0.5%. Adding additional sub-cells has been shown to increase power conversion efficiency above 12%.

Che, Xiaozhou↗

Adapting Optimal Velocity Tracking Control to Account for WEC Constraints and Power-Take-Off Efficiencies: Preprint

Wave energy converters (WECs) come in many different forms, from point absorbers, oscillating water columns, to bulge wave devices. This paper focuses on the control of point absorber WECs, which typically have a narrow-banded frequency response and, therefore, control is well placed to improve the energy capture of such WECs. The acausal nature of the control problem means that theoretically optimal control is almost impossible to achieve inpractice; however optimal velocity tracking (OVT) offers a simple and robust approximation to optimal control that can achieve better power capture than passive linear damping methods, albeit with necessarily higher force demands. OVT is a form of impedance matching and the magnitude of the power-take off (PTO) force demand is often not linearly proportional to the WEC velocity, which can lead to PTO force and speed combinations far from the optimalPTO efficiency. The highly non-linear PTO force and speed to efficiency mapping can, without remedial measures, severely diminish the effectiveness of OVT techniques. In this paper, limits to the movement and force of the PTO are demonstrated, allowing OVT to be more easily applied in practice. The effect of PTO efficiency is explored, and a potential solution to the problem of adapting control to account for efficiency is presented. Both aspects of the work presented highlight the requirement for co-design of the WEC, PTO, and controller.

conversion efficiency↗

Influence of Copper Composition on Cu 2 BaSn(S,Se) 4 Solution-Deposited Films and Photovoltaic Devices with Over 5% Efficiency

Cu 2 BaSn(S,Se) 4 is currently in the spotlight for prospective environmentally friendly, stable, thin-film solar cell application, with demonstrated device power conversion efficiency (PCE) exceeding 5% for vacuum-deposited absorbers. As suggested by first-principles calculations, experimental studies involving related Cu 2 ZnSn(S,Se) 4 and Cu(In,Ga)(S,Se) 2 absorbers prove that the detailed chemical composition typically plays a sensitive role in altering defects and electronic properties of these complicated compound semiconductors. Herein, the copper composition of Cu 2 BaSn(S,Se) 4 has been systematically modified, employing a solution-based deposition approach, to provide a more complete picture of the phase stability and optoelectronic property sensitivity for this material. X-ray diffraction and scanning electron microscopy show that phase purity is preserved over a film Cu content range of nominally 0.94 ≤ [Cu]/[Ba + Sn] ≤ 1.01. Terahertz spectroscopy and Hall effect measurements reveal that the majority carrier hole density of ~10 13 cm –3 and mobility (~5 cm 2 /V s), as well as the minority carrier lifetime (a bulk lifetime of 180 ps and a surface recombination velocity >106 cm/s), are nominally independent of Cu content. The champion PCEs exceed 4.7% for all copper compositions in the phase-pure region, with a record value of 5.1%, similar to the reported values for record vacuum-deposited devices. Furthermore, these results suggest that Cu 2 BaSn(S,Se) 4 films and solar cells (at the current performance level) may be less sensitive to Cu stoichiometry compared to kesterite materials and therefore may provide a more stable material platform to prepare thin-film solar cells.

(CBTSSe)↗

Revisiting Theoretical Limits for One Degree-of-Freedom Wave Energy Converters

This work revisits the theoretical limits of one degree-of-freedom wave energy converters (WECs). This work considers the floating sphere used in the OES Task 10 WEC modeling and verification effort for analysis. Analytical equations are derived to determine bounds on displacement amplitude, time-averaged power (TAP), and power-take-off (PTO) force. A unique result found shows that the TAP absorbed by a WEC can be defined solely by the inertial properties and radiation hydrodynamic coefficients. In addition, a unique expression for the PTO force was derived that provides lower and upper bounds when resistive control is used to maximize power generation. For complex conjugate control, this same expression only provides a lower bound, as there is theoretically no upper bound. These bounds assist in comparing the performance of the floating sphere if it were to extract energy using surge or heave motion. The analysis shows because of differences in hydrodynamic coefficients for each oscillating mode, there are different frequency ranges that provide better power capture efficiency. The influence of a motion constraint on TAP while utilizing a nonideal power take-off is examined and found to reduce the losses associated with bidirectional energy flow. The expression to calculate TAP with a nonideal PTO is modified by the electrical conversion efficiency and the ratio of the PTO spring and damping coefficients. Furthermore, the PTO spring and damping coefficients were separated in the expression, allowing for limits to be set on the PTO coefficients to ensure net power generation.

16 TIDAL AND WAVE POWER↗

Using Resin to Reduce Silica in Borated Fluid - 20072

The Electric Power Research Institute (EPRI) strongly recommends the concentration of silica in the reactor coolant be limited, potential ingress be carefully controlled, and frequently monitored to assess potential silica deposits on fuel cladding surfaces. Boraflex is a product with silicone rubber encasing a neutron absorber for criticality control, and it was installed in the majority of nuclear power plant spent fuel pools. Over time and in the presence of radiation, the silicone rubber lining degrades into silica (SiO{sub 2}) and hydrogen gas. Silica is somewhat soluble in water and spent fuel pool water communicates with other plant systems during refueling outages, leading to a buildup of silica in the reactor coolant and connected systems. Due to the prevalence of Boraflex racks in spent fuel pools, the presence of silica is a chronic nuclear industry concern. To address this concern, many nuclear plants have installed reverse osmosis skid systems to remove the silica from their spent fuel pools and, by extension, from reactor coolant. These skids are expensive to install and maintain. Arcadis personnel demonstrated that an iron-impregnated resin could be used to remove silica from borated systems without impacting the water quality. The resin was readily available, inexpensive, and easy to install in existing plant equipment. During a nuclear power plant's refueling outage the iron-impregnated resin proved to be effective in reducing the need for feed and bleed operations, with concurrent cost savings and reduction in required outage water management activities. Thus, the following savings were realized: - Eliminated the need to purchase, install, and maintain a reverse osmosis system avoiding more than $10 million in up-front capital cost and ongoing operating and maintenance costs. - Removed 9.57 kilograms (21 pounds) of silica dioxide from the primary system fluid. - Reduced the volume of feed and bleed from 70,000 gallons (2.65 E+05 liters) to 35,000 gallons (1.32 E+05 liters). - Saved $380,000 in water production and disposal costs. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Small Scale WEC Performance Modeling Data

Small Scale WEC Performance Modeling Data is performance data from downscaled models of common WEC devices and their calculated performance outputs. This data is used by the Small WEC interactive modeling tool hosted by PRIMRE. The devices include a point absorber, a two-body point absorber (RM3), an oscillating surge device (OSWEC), and an attenuator type device (McCabe Wave Pump). One of the primary use cases for this work is to give an easy way to compare power output for a variety of WECs and model sizes.

16 TIDAL AND WAVE POWER↗

Cracked Film Lithography with CuGaO x Buffers for Bifacial CdTe Photovoltaics

Abstract Bifacial CdTe solar cells with greater power density than the monofacial baselines are demonstrated by using a CuGaO x rear interface buffer that passivates while reducing sheet resistance and contact resistance. Inserting CuGaO x between the CdTe and Au increases mean power density from 18.0 ± 0.5 to 19.8 ± 0.4 mW cm −2 for one sun front illumination. However, coupling CuGaO x with a transparent conductive oxide leads to an electrical barrier. Instead, CuGaO x is integrated with cracked film lithography (CFL)‐patterned metal grids. CFL grid wires are spaced narrowly enough (≈10 µm) to alleviate semiconductor resistance while retaining enough passivation and transmittance for a bifacial power gain: bifacial CuGaO x /CFL grids generate 19.1 ± 0.6 mW cm −2 for 1 sun front + 0.08 sun rear illumination and 20.0 ± 0.6 mW cm −2 at 1 sun front + 0.52 sun rear—the highest reported power density at field albedo conditions for a scaled polycrystalline absorber.

14 SOLAR ENERGY↗

Transpiration-powered desalination water bottle

Inspired by mangrove trees, we present a theoretical design and analysis of a portable desalinating water bottle powered by transpiration. The bottle includes an annular fin for absorbing solar heat, which is used to boost the evaporation rate of water from the interior synthetic leaf. This synthetic leaf comprises a nanoporous film deposited atop a supporting micromesh. Water evaporating from the leaf generates a highly negative Laplace pressure, which pulls the overlying source water across an upstream reverse osmosis membrane. Evaporated water is re-condensed in the bottom of the bottle for collection. The benefit of our hybrid approach to desalination is that reverse osmosis is spontaneously enabled by transpiration, while the thermal evaporation process is enhanced by heat localization and made more durable by pre-filtering the salt. Finally, we estimate that a 9.4 cm diameter bottle, with a 10 cm wide annular fin, could harvest about a liter of fresh water per day from ocean water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

OmniXAS: A universal deep-learning framework for materials x-ray absorption spectra

X-ray absorption spectroscopy (XAS) is a powerful characterization technique for probing the local chemical environment of absorbing atoms. However, analyzing XAS data presents significant challenges, often requiring extensive, computationally intensive simulations, as well as significant domain expertise. These limitations hinder the development of fast, robust XAS analysis pipelines that are essential in high-throughput studies and for autonomous experimentation. Here, we address these challenges with OmniXAS, a framework that contains a suite of transfer learning approaches for XAS prediction, each uniquely contributing to improved accuracy and efficiency, as demonstrated on the K-edge spectra database covering eight 3⁢d transition metals (Ti–Cu). The OmniXAS framework is built upon three distinct strategies. First, we use M3GNet [Nat. Comput. Sci. 2, 718 (2022)] to derive latent representations of the local chemical environment of absorption sites as input for XAS prediction, achieving significant improvements over conventional featurization techniques. Second, we employ a hierarchical transfer learning strategy, training a universal multitask model across elements before fine-tuning for element-specific predictions. Models based on this cascaded approach after elementwise fine-tuning outperform element-specific models by up to 69%. Third, we implement cross-fidelity transfer learning, adapting a universal model to predict spectra generated by simulation of a different fidelity with a much higher computational cost. This approach improves prediction accuracy by up to 11% over models trained on the target fidelity alone. Our approach significantly boosts the throughput of XAS modeling by orders of magnitude as compared to first-principles simulations and is extendable to XAS prediction for a broader range of elements. The proposed transfer learning framework is generalizable to enhance deep-learning models that target other properties in materials research.

36 MATERIALS SCIENCE↗

Effects of Heave Plate Topology on Reaction Forces

Multi-body wave energy converters often rely on "heave plates" to generate the reaction forces required for energy harvesting. However, the influence of threedimensional heave plate topology on these reaction forces is relatively unexplored in the literature. Using laboratory experiments, we investigate the reaction forces generated by three distinct heave plate topologies: A flat hexagonal plate, an open hexagonal-conic, and an enclosed hexagonalconic (i.e., interior cavity flooded with water). Though the flat plate is the least massive of the topologies, it generates the greatest total reaction force for nearly all experimental cases due to higher fluid force. Our results also demonstrate that the flat plate generally experiences the greatest force variability between the three topologies, especially during relatively large oscillations (KC greater than 2). Globally, force variability increases with the Keulegan Carpenter (KC) number. These results highlight the importance of heave plate topology on multi-body point wave energy converter performance.

heave plate↗

A model investigation of the impact of lower hybrid wave scattering angle on current drive profile in EAST and Alcator C-Mod

Lower hybrid current drive (LHCD) is beneficial for developing a steady-state operation scenario in a tokamak. This paper conducts a modeling investigation to identify an optimum rotation angle of the initial lower hybrid perpendicular (to the background magnetic field $\overrightarrow{B}$) wavevector for best matching the experimental RF current profile. It is hypothesized that central RF power deposition widely observed in the present-day LHCD experiments arises from wave scattering by turbulence. In a standard model without considering such interactions, the predicted power deposition profile is generally broad with off-axis peaking, not in agreement with experimental observations. A heuristic approach is adopted by introducing a spectral broadening mechanism by modifying the initial orientation of the perpendicular wavevector. The ray-tracing/Fokker–Planck solver GENRAY/CQL3D is utilized within the python-based π-scope framework. A focus is given to identify the perpendicular wavenumber orientation angle with respect to the magnetic surface normal vector at the initial ray location. Our modeling study shows that rotating the perpendicular wavevector in such a way as to increase the initial poloidal component is effective in reproducing the centrally peaked current profile observed in normal shear plasmas on both EAST and C-Mod. These waves can readily be absorbed to the central plasma, which reduces the sensitivity of the power deposition profile to a slight change of the plasma condition. The same approach is also found to help broaden the off-axis power deposition profile in a reverse-shear EAST plasma, leading to a better agreement with the experiment. The results presented here suggest that spectral modification arising from edge density fluctuations in a tokamak may need to be considered in understanding wave propagation and absorption. A further experimental and theoretical/modeling study is vital as a reverse approach is adopted in this study. Finally, our work suggests that mitigation or control measures are critical for parasitic effects occurring on the first pass in a reactor regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unstructured mesh-based multi-physics reactor transient simulation with iMC code

In this study, we present a time-dependent Monte Carlo simulation result about a complex fuel-loaded light water reactor system with thermal-hydraulic feedback using the KAIST iMC code. The intra-pin temperature distribution is calculated based on Monte Carlo-tallied detailed power distribution and the finite element heat transfer method. The temperature effect of fuel, absorber, and coolant are adequately reflected into the dynamic response by the on-the-fly Doppler broadened cross-section correction. For the time-dependent Monte Carlo transport simulation, the predictor-corrector quasi-static Monte Carlo method is used for this study. We tested the coupled analysis framework with a 17-by-17 fuel assembly loaded with the centrally-shielded burnable absorber (CSBA) fuel element. The temperature feedback effect on the material cross-section and the moderator density incurred negative reactivity in response to the external positive reactivity insertion, showing the inherent stability of the reactor system. The pin-wise power and temperature change during the system transient are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗