Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Building a Community Infrastructure for Scalable On-Line Performance Analysis Tools around Open|Speedshop (Final Technical Report)

Peta-scale computing environments pose significant challenges for both system and application developers and addressing them required more than simply scaling up existing tera-scale solutions. Performance analysis tools play an important role in gaining this understanding, but previous monolithic tools with fixed feature sets have not sufficed. Instead, this project worked on the design, implementation, and evaluation of a general, flexible tool infrastructure supporting the construction of performance tools as “pipelines” of high-quality tool building blocks. These tool building blocks provide common performance tool functionality, and are designed for scalability, lightweight data acquisition and analysis, and interoperability. For this project, we built on Open|SpeedShop, a modular and extensible open source performance analysis tool set.

97 MATHEMATICS AND COMPUTING↗

Creation of System Validation Platform

SNL and SunSpec were to create a System Validation Platform to verify the functionality of DERs with advanced grid functionality and utility communication capabilities. The Validation Platform software was to ensure DERs are compatible with new grid interconnection requirements for these advanced functions by communicating to equipment under test, data acquisition software, and test equipment.

97 MATHEMATICS AND COMPUTING↗

Sweet Sorghum Genotypes Tolerant and Sensitive to Nitrogen Stress Select Distinct Root Endosphere and Rhizosphere Bacterial Communities

The belowground microbiomes have many beneficial functions that assist plant growth, including nutrient cycling, acquisition and transport, as well as alleviation of stresses caused by nutrient limitations such as nitrogen (N). Here we analyzed the root endosphere, rhizosphere and soil bacterial communities of seven sweet sorghum genotypes differing in sensitivity to N-stress. Sorghum genotypes were grown in fields with no (low-N) or sufficient (high-N) N. The dry shoot weight ratio (low-N/high-N) was used to determine N-stress sensitivity. Our hypothesis was that genotypes tolerant and sensitive to N-stress select distinct bacterial communities. The endosphere and rhizosphere bacterial community structure were significantly different between the N-stress sensitive and tolerant genotypes in the high-N field, but not in the low-N field. However, significant changes in the relative abundance of specific bacterial taxa were observed in both fields. Streptomyces, a bacterial genus known to alleviate plant abiotic stresses, was enriched in the endosphere and rhizosphere of the tolerant genotypes in the low-N field. Our study indicates that sweet sorghum genotypes tolerant to N-stress select taxa that can potentially mitigate the N-stress, suggesting that the interactions between N-stress tolerant lines and the root-associated microbiome might be vital for coping with N-stress.

59 BASIC BIOLOGICAL SCIENCES↗

WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice. Fluoroscopy 2.0: Physics support of fluoroscopy should be operationally as opposed to compliance focused. Testing protocols must address new hardware, acquisition methods, and image processing. Future available tools are discussed. Proper configuration of acquisition parameters (focal spot size, voltage and added filter, tube current, pulse width, pulse rate, scatter removal) as a function of patient size from the neonate to bariatric patient is key to providing diagnostic image quality at properly managed radiation doses. Learning Objectives: Appreciate the limitations of the currently available tools and techniques in clinical medical physics in radiography, mammography, and fluoroscopy, and ways to improve upon current deficiencies. Appreciate the changing environment of imaging practice and the need for the medical physicist to be an expert consultant and educator in a capacity that extends beyond the annual survey of equipment. Understand the status of the rapidly changing environment in breast imaging from planar imaging to tomosynthesis and possibly to breast CT. Identify appropriate configuration of acquisition parameters as a function of patient size to manage radiation dose and ensure diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

Sub-Ångstrom electric field measurements on a universal detector in a scanning transmission electron microscope

Scanning transmission electron microscopy (STEM) excels in accessing atomic-scale structure and chemistry. Enhancing our ability to directly image the functionalities of local features in materials has become one of the most important topics in the future development of STEM. Recently, differential phase contrast (DPC) imaging has been utilized to map the internal electric and magnetic fields in materials from nanoscale features such as p–n junctions, skyrmions, and even from individual atoms. Here, we use an ultra-low noise SCMOS detector in as the diffraction plane camera to collect four-dimensional (4D) datasets. The high angular resolution, efficient high-SNR acquisition, and modifiability of the camera allow it to function as a universal detector, where STEM imaging configurations, such as DPC, bright field, annular bright field, and annular dark field can all be reconstructed from a single 4D dataset. By examining a distorted perovskite, DyScO3, which possesses projected lattice spacings as small as 0.83 Å, we demonstrate DPC spatial resolution almost reaching the information limit of a 100 keV electron beam. In addition, the perovskite has ordered O-coordinations with alternating octahedral tilts, which can be quantitatively measured with single degree accuracy by taking advantage of DPC’s sensitivity to light atoms. The results, acquired on a standard Ronchigram camera as opposed to a specialized DPC detector, open up new opportunities to understand and design functional materials and devices that involve lattice and charge coupling at nano- and atomic-scales.

47 OTHER INSTRUMENTATION↗

SOX1 links the function of neural patterning and Notch signalling in the ventral spinal cord during the neuron-glial fate switch

During neural development the transition from neurogenesis to gliogenesis, known as the neuron-glial ({Nu}/G) fate switch, requires the coordinated function of patterning factors, pro-glial factors and Notch signalling. How this process is coordinated in the embryonic spinal cord is poorly understood. Here, we demonstrate that during the N/G fate switch in the ventral spinal cord (vSC) SOX1 links the function of neural patterning and Notch signalling. We show that, SOX1 expression in the vSC is regulated by PAX6, NKX2.2 and Notch signalling in a domain-specific manner. We further show that SOX1 regulates the expression of Hes1 and that loss of Sox1 leads to enhanced production of oligodendrocyte precursors from the pMN. Finally, we show that Notch signalling functions upstream of SOX1 during this fate switch and is independently required for the acquisition of the glial fate perse by regulating Nuclear Factor I A expression in a PAX6/SOX1/HES1/HES5-independent manner. These data integrate functional roles of neural patterning factors, Notch signalling and SOX1 during gliogenesis.

60 APPLIED LIFE SCIENCES↗

Adsorption Hysteresis Under Control: Tuning Host–Guest Interactions via a Genetic Algorithm

Mesoporous adsorbent materials offer a large volumetric capacity; however, cyclic adsorption/desorption processes in these systems often suffer from hysteresis and may require a significant pressure swing to access this capacity. To mitigate hysteresis, a proposed strategy is to include nucleation sites on the walls of the mesoporous material to facilitate droplet and bubble formation, lowering the free energy barriers to the respective phase transitions. It is unclear, however, what combination of adsorbate− adsorbent interactions and spatial patterning would be beneficial for a given application, considering that improvements to some sorption properties may come at the expense of other attributes. To understand these interconnected observables, we examine two model systems, planar-slit and cylindrical pores with tunable interaction sites, using GPU-accelerated transition matrix Monte Carlo simulations. The simulations provide a free energy map of the pressure−adsorption space in a matter of minutes, which we use to track adsorption isotherm characteristics as a function of adsorbent properties. We then leverage the rapid acquisition of simulation data to construct a genetic algorithm to iteratively modify interaction sites of the slit-pore wall to minimize the hysteresis of this system without sacrificing uptake. We find that the adsorption branch of the isotherm is easily modulated via the average host−guest interaction strength, but desorption is only adjustable if there is a suitable bubble nucleation site. Within the context of a slit-pore system, we identify relative interaction strengths and patch sizes required to gain control over both branches of the hysteresis loop.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The digital mirror Langmuir probe: Field programmable gate array implementation of real-time Langmuir probe biasing

High bandwidth, high spatial resolution measurements of electron temperature, density, and plasma potential are valuable for resolving turbulence in the boundary plasma of tokamaks. While conventional Langmuir probes can provide such measurements, either their temporal or spatial resolution is limited: the former by the sweep rate necessary for obtaining I-V characteristics and the latter by the need to use multiple electrodes, as is the case in triple and double probe configurations. The Mirror Langmuir Probe (MLP) bias technique overcomes these limitations by rapidly switching the voltage on a single electrode cycling between three bias states, each dynamically optimized for the local plasma conditions. The MLP system on Alcator C-Mod used analog circuitry to perform this function, measuring Te, VF, and Isat at 1.1 MSPS. Recently, a new prototype digital MLP controller has been implemented on a Red Pitaya Field Programmable Gate Array (FPGA) board which reproduces the functionality of the original controller and performs all data acquisition. There is also the potential to provide the plasma parameters externally for use with feedback control systems. The use of FPGA technology means the system is readily customizable at a fraction of the development time and implementation cost. A second Red Pitaya was used to test the MLP by simulating the current response of a physical probe using C-Mod experimental measurements. This project is available as a git repository to facilitate extensibility (e.g., real-time control outputs and more voltage states) and scalability through collaboration.

47 OTHER INSTRUMENTATION↗

SU-C-12A-06: A Universal Definition for CT Irradiated Length

Purpose: The length of scan shown or calculated from the console is the distance between the center of the starting and ending images. The irradiated length for such a set of images can vary substantially from this distance, depending on the acquisition mode. We propose that the rise to equilibrium function h(λ) be used to uniquely define an irradiated length independent of the details of the scanning process. This method also seamlessly accommodates recent developments in active collimation. Method: h(λ) is determined along the central axis of a long cylindrical phantom, ideally from integration of the dose spread function. For practical reasons h(λ) may be approximated from helical scans with real-time dose rate measurements or from a series of central dose measurements using finite irradiated length exposures. For a particular scan then, the irradiated length λ is calculated from a central dose measurement of h and then applying the inverse function h(λ){sup -1}. Results: h(λ) was determined from measurements made in a prototype ICRU/TG200 phantom, 60 cm long and 30 cm in diameter. The resultant λ generally agreed with indicated scan length plus one beam width for axial and indicated scan length for helical scans if overscanning was accounted for. For most scanners, DLP/CTDIvol is a good measure of irradiated length allowing for another index of comparison. Conclusion: Central dose measurements with a small chamber along with the rise to equilibrium function h(λ) provide us with a robust and consistent means of determining scan length independent of the means of irradiation over a variety of scanners and scanning conditions. The method is limited to λ significantly less than the equilibrium.

60 APPLIED LIFE SCIENCES↗

SU-E-I-12: Characterization of Edge Effects in a Commercial Low-Dose Image Processing System

Purpose: Minimizing radiation dose while preserving image quality is critical in fluoroscopic imaging. One recent development is a noise reduction system (Allura Clarity) offered by Philips. Others have reported approximately 50% reduction in air kerma when using Clarity. These studies, however, provide only a cursory look at how the Clarity system affects image quality. The purpose of this work was to evaluate the effect of Clarity on the appearance of high-frequency image information. Methods: A lead attenuator with a smooth edge was imaged on two Philips Allura FD20 detectors: one with Clarity and one without. The edge was positioned in the center of the field of view and images were obtained under the following conditions: 40cm and 11cm fields of view, single shot and continuous fluoroscopy modes, and using abdomen and cardiac protocols, for a total of sixteen imaging conditions. Profiles were drawn perpendicular to the edge across 80% of its length, averaged to reduce noise, normalized to the maximum pixel value, and plotted as a function of distance. Results: For all single-shot acquisitions and most fluoroscopic images, overshoot of the edge was observed. This effect was more substantial for single-shot acquisitions (∼20%) than for fluoroscopic images (∼50%). For fluoroscopic acquisition, the overshoot decayed more quickly with the Clarity system. However, the system with Clarity introduced a ringing effect for both single-shot and fluoroscopic images that is not present on the non-Clarity system. Conclusion: Previous reports have demonstrated a substantial dose reduction when using Clarity but the impact this has on image appearance has not been characterized. One demonstrated difference is the change in appearance of high-frequency image information. It remains to be determined whether this effect may impact clinical images adversely.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensor Commercialization

The objective of this CRADA was the transfer the BaDx technology to a commercial partner, Aquila Technologies, to develop BaDx for medium-scale production. BaDx is a stand-alone, diagnostics cartridge for use in resourcelimited and challenging environments to sense low concentrations (<100 spores) of virulent pathogenic bacteria. The fully sealed cartridge also contains a “self-destruct” feature in which the device contents are sterilized post-assay. The ultimate goal of this CRADA was realized as validated and full-functioning BaDx cartridges are currently available for purchase and acquisition from Aquila. This project also resulted in significant and prestigious recognitions including, a R&D100 Award (2014), a Federal Laboratory Consortium (FLC) Excellence in Technology Transfer Award (2015), Popular Science Magazine naming BaDx ‘One of the Greatest Innovations of 2015,” and a TechConnect National Innovation Award (2015). Further, this CRADA resulted in a commercially viable bioagent detection platform transitioned from a national laboratory to industry that may significantly enhance national security by reducing the threat from biological agents that are stored and maintained in laboratories with poor safety and security protocols. Hospital, health clinic and at-home healthcare could also be revolutionized by this technology. This work has already lead to two follow-on projects, one funded by the US Department of Homeland Security (DHS), and the other by the US State Department.

47 OTHER INSTRUMENTATION↗

The Digital Mirror Langmuir Probe: Field Programmable Gate Array Implementation of Real-Time Langmuir Probe Biasing

High bandwidth, high spatial resolution measurements of electron temperature, density and plasma potential are valuable for resolving turbulence in the boundary plasma of tokamaks. While conventional Langmuir probes can provide such measurements either their temporal or spatial resolution is limited: the former by the sweep rate necessary for obtaining I-V characteristics and the latter by the need to use multiple electrodes, as is the case in triple and double probe configurations. The Mirror Langmuir Probe (MLP) bias technique overcomes these limitations by rapidly switching the voltage on a single electrode cycling between three bias states, each dynamically optimised for the local plasma conditions. The MLP system on Alcator C-Mod used analog circuitry to perform this function, measuring Te, VF, and Isat at 1.1 MSPS. Recently, a new prototype digital MLP controller has been implemented on a Red Pitaya Field Programmable Gate Array (FPGA) board which reproduces the functionality of the original controller and performs all data acquisition. There is also the potential to provide the plasma parameters externally for use with feedback control systems. The use of FPGA technology means the system is readily customisable at a fraction of the development time and implementation cost. A second Red Pitaya was used to test the MLP by simulating the current response of a physical probe using C-Mod experimental measurements. This project is available as a git repository to facilitate extensibility (e.g. real-time control outputs, more voltage states) and scalability through collaboration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional fourier transform spectrometer

The present invention relates to a system and methods for acquiring two-dimensional Fourier transform (2D FT) spectra. Overlap of a collinear pulse pair and probe induce a molecular response which is collected by spectral dispersion of the signal modulated probe beam. Simultaneous collection of the molecular response, pulse timing and characteristics permit real time phasing and rapid acquisition of spectra. Full spectra are acquired as a function of pulse pair timings and numerically transformed to achieve the full frequency-frequency spectrum. This method demonstrates the ability to acquire information on molecular dynamics, couplings and structure in a simple apparatus. Multi-dimensional methods can be used for diagnostic and analytical measurements in the biological, biomedical, and chemical fields.

47 OTHER INSTRUMENTATION↗

Two-dimensional fourier transform spectrometer

The present invention relates to a system and methods for acquiring two-dimensional Fourier transform (2D FT) spectra. Overlap of a collinear pulse pair and probe induce a molecular response which is collected by spectral dispersion of the signal modulated probe beam. Simultaneous collection of the molecular response, pulse timing and characteristics permit real time phasing and rapid acquisition of spectra. Full spectra are acquired as a function of pulse pair timings and numerically transformed to achieve the full frequency-frequency spectrum. This method demonstrates the ability to acquire information on molecular dynamics, couplings and structure in a simple apparatus. Multi-dimensional methods can be used for diagnostic and analytical measurements in the biological, biomedical, and chemical fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of fungistatics in soil reduces N uptake by an arctic ericoid shrub (Vaccinium vitis-idaea)

In arctic tundra soil N is highly limiting, N mineralization is slow and organic N greatly exceeds inorganic N. We studied the effects of fungistatics (azoxystrobin [Quadris{reg_sign}] or propiconazole [Tilt{reg_sign}]) on the fungi isolated from ericaceous plant roots in vitro. In addition to testing the phytotoxicity of the two fungistatics we also tested their effects on growth and nitrogen uptake of an ericaceous plant (Vaccinium uliginosum) in a closed Petri plate system without root-associated fungi. Finally, to evaluate the fungistatic effects in an in vivo experiment we applied fungistatics and nitrogen isotopes to intact tundra soil cores from Toolik Lake, Alaska, and examined the ammonium-N and glycine-N use by Vaccinium vitis-idaea with and without fungistatics. The experiments on fungal pure cultures showed that Tilt{reg_sign} was more effective in reducing fungal colony growth in vitro than Quadris{reg_sign}, which was highly variable among the fungal strains. Laboratory experiments aiming to test the fungistatic effects on plant performance in vitro showed that neither Quadris{reg_sign} nor Tilt{reg_sign} affected V. uliginosum growth or N uptake. In this experiment V. uliginosum assimilated more than an order of magnitude more ammonium-N than glycine-N. The intact tundra core experiment provided contrasting results. After 10 wk of fungistatic application in the growth chamber V. vitis-idaea leaf %N was 10% lower and the amount of leaf {sup 15}N acquired was reduced from labeled ammonium (33%) and glycine (40%) during the 4 d isotope treatment. In contrast to the in vitro experiment leaf {sup 15}N assimilation from glycine was three times higher than from {sup 15}NH{sub 4} in the treatments that received no-fungistatics. We conclude that the function of the fungal communities is essential to the acquisition of N from organic sources and speculate that N acquisition from inorganic sources is mainly inhibited by competition with complex soil microbial communities.

54 ENVIRONMENTAL SCIENCES↗

On the Viability of Using Autonomous Three-Component Nodal Geophones to Calculate Teleseismic Ps Receiver Functions with an Application to Old Faithful, Yellowstone

Recent advances in seismic data-acquisition technology paired with an increasing interest from the academic passive source seismological community have opened up new scientific targets and imaging possibilities, often referred to as Large-N experiments (large number of instruments). The success of these and other deployments has motivated individual researchers, as well as the larger seismological community, to invest in the next generation of nodal geophones. Although the new instruments have battery life and bandwidth limitations compared to broadband instruments, the relatively low deployment and procurement cost of these new nodal geophones provides an additional novel tool for researchers. In this paper, we explore the viability of using autonomous three-component nodal geophones to calculate teleseismic Ps receiver functions by comparison of co-located broadband stations and highlight some potential advantages with a dense nodal array deployed around the Upper Geyser basin in Yellowstone National Park. Two key findings from this example include (1) very dense nodal arrays can be used to image small-scale features in the shallow crust that typical broadband station spacing would alias, and (2) nodal arrays with a larger footprint could be used to image deeper features with greater or equal detail as typical broadband deployments but at a reduced deployment cost.

15 GEOTHERMAL ENERGY↗

Novel Transporter Required for Biogenesis of cbb3-Type Cytochrome c Oxidase in Rhodobacter capsulatus

The acquisition, delivery, and incorporation of metals into their respective metalloproteins are important cellular processes. These processes are tightly controlled in order to prevent exposure of cells to free-metal concentrations that could yield oxidative damage. Copper (Cu) is one such metal that is required as a cofactor in a variety of proteins. However, when present in excessive amounts, Cu is toxic due to its oxidative capability. Cytochrome c oxidases (Coxs) are among the metalloproteins whose assembly and activity require the presence of Cu in their catalytic subunits. In this study, we focused on the acquisition of Cu for incorporation into the heme-Cu binuclear center of the cbb3-type Cox (cbb3-Cox) in the facultative phototroph Rhodobacter capsulatus. Genetic screens identified a cbb3-Cox defective mutant that requires Cu 2+ supplementation to produce an active cbb3-Cox. Complementation of this mutant using wild-type genomic libraries unveiled a novel gene (ccoA) required for cbb3-Cox biogenesis. In the absence of CcoA, the cellular Cu content decreases and cbb3-Cox assembly and activity become defective. CcoA shows homology to major facilitator superfamily (MFS)-type transporter proteins. Members of this family are known to transport small solutes or drugs, but so far, no MFS protein has been implicated in cbb3-Cox biogenesis. These findings provide novel insights into the maturation and assembly of membrane-integral metalloproteins and on a hitherto-unknown function(s) of MFS-type transporters in bacterial Cu acquisition.

59 BASIC BIOLOGICAL SCIENCES↗

Results from a multi-laboratory ocean metaproteomic intercomparison: effects of LC-MS acquisition and data analysis procedures

Metaproteomics is an increasingly popular methodology that provides information regarding the metabolic functions of specific microbial taxa and has potential for contributing to ocean ecology and biogeochemical studies. A blinded multi-laboratory intercomparison was conducted to assess comparability and reproducibility of taxonomic and functional results and their sensitivity to methodological variables. Euphotic zone samples from the Bermuda Atlantic Time-series Study (BATS) in the North Atlantic Ocean collected by in situ pumps and the autonomous underwater vehicle (AUV) Clio were distributed with a paired metagenome, and one-dimensional (1D) liquid chromatographic data-dependent acquisition mass spectrometry analysis was stipulated. Analysis of mass spectra from seven laboratories through a common bioinformatic pipeline identified a shared set of 1056 proteins from 1395 shared peptide constituents. Quantitative analyses showed good reproducibility: pairwise regressions of spectral counts between laboratories yielded R 2 values averaged 0.62±0.11, and a Sørensen similarity analysis of the top 1000 proteins revealed 70 %–80 % similarity between laboratory groups. Taxonomic and functional assignments showed good coherence between technical replicates and different laboratories. A bioinformatic intercomparison study, involving 10 laboratories using eight software packages, successfully identified thousands of peptides within the complex metaproteomic datasets, demonstrating the utility of these software tools for ocean metaproteomic research. Lessons learned and potential improvements in methods were described. Future efforts could examine reproducibility in deeper metaproteomes, examine accuracy in targeted absolute quantitation analyses, and develop standards for data output formats to improve data interoperability. Together, these results demonstrate the reproducibility of metaproteomic analyses and their suitability for microbial oceanography research, including integration into global-scale ocean surveys and ocean biogeochemical models.

59 BASIC BIOLOGICAL SCIENCES↗