Search NASA⌕ Search

SEARCH · Search NASA

Results for “actuation devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Auxiliary Control Mechanisms For RUM Actuators

RUM actuator proposed device mounted on gimbaled, pivoted, or freely floating instrument and used to make instrument oscillate about one or more axes. Includes one or more (typically, two) unbalanced masses (e.g., lump masses on arms) for each axis about which oscillation desired. Unbalanced masses driven to rotate at constant angular velocity to produce oscillating centrifugal forces, which, in turn, exerts cyclic torques that make instrument oscillate about desired axis. Used in both terrestrial and spacecraft applications: for example, to oscillate instruments as diverse as x-ray telescopes, magnetometers, accelerometers, and agricultural spraying nozzles in variety of scan patterns that include linear, circular, and raster. Weights, power demands, and costs reduced.

Polites, Michael E.↗

Active Member Design, Modeling, and Verification

The design and development of active members intended for use in structural control applications is presented. The use of three different solid state actuation materials, namely, piezoelectric, electrostictive, and magnetostrictive, is discussed. Test data is given in order to illustrate the actuator and device characteristics and performance.

Designpiezoelectric electrostrictive magnetostrict↗

Cryogenic shutter

A magnetically operated shutter mechanism is provided that will function in cryogenic or cryogenic zero gravity environments to selectively block radiation such as light from passing through a window to a target object such as a mirror or detector located inside a cryogenic container such as a dewar. The mechanism includes a shutter paddle blade that is moved by an electromagnetically actuated torquing device between an open position where the target object is exposed to ambient radiation or light and a closed position where the shutter paddle blade shields the ambient radiation or light from the target object. The purpose of the shuttering device is to prevent the mirror or other target object from being directly exposed to radiation passing through the window located on the side wall of the dewar, thereby decreasing or eliminating any temperature gradient that would occur within the target object due to exposure to the radiation. A special nylon bearing system is utilized to prevent the device from binding during operation and the paddle blade is also termally connected to a reservoir containing the cryogen to further reduce the internal temperature.

Barney, Richard D.↗

Docking system for spacecraft

A mechanism for the docking of a space vehicle to a space station where a connection for transfer of personnel and equipment is desired. The invention comprises an active docking structure on a space vehicle 10 and a passive docking structure on a station 11. The passive structure includes a docking ring 50 mounted on a tunnel structure 35 fixed to the space station. The active structure including a docking ring 18 carried by actuator-attenuator devices 20, each attached at one end to the ring 18 and at its other end in the vehicle's payload bay 12. The devices 20 respond to command signals for moving the docking ring 18 between a stowed position in the space vehicle to a deployed position suitable for engagement with the docking ring 50. The devices 20 comprise means responsive to signals of sensed loadings to absorb impact energy and retraction means for drawing the coupled space vehicle and station into final docked configuration and moving the tunnel structure to a berthed position in the space vehicle 10. Latches 60 couple the space vehicle and space station upon contact of docking rings 18 and 50 and latches 41-48 establish a structural tie between the spacecraft when retracted.

Kahn, Jon B.↗

Pressure and Thrust Measurements of a High-Frequency Pulsed-Detonation Actuator

This paper describes the development of a small-scale, high-frequency pulsed detonation actuator. The device utilized a fuel mixture of H2 and air, which was injected into the device at frequencies of up to 1200 Hz. Pulsed detonations were demonstrated in an 8-inch long combustion volume, at approx.600 Hz, for the lambda/4 mode. The primary objective of this experiment was to measure the generated thrust. A mean value of thrust was measured up to 6.0 lb, corresponding to specific impulse of 2611 s. This value is comparable to other H2-fueled pulsed detonation engines (PDEs) experiments. The injection and detonation frequency for this new experimental case was approx.600 Hz, and was much higher than typical PDEs, where frequencies are usually less than 100 Hz. The compact size of the model and high frequency of detonation yields a thrust-per-unit-volume of approximately 2.0 lb/cu in, and compares favorably with other experiments, which typically have thrust-per-unit-volume values of approximately 0.01 lb/cu in.

Nguyen, Namtran C.↗

Simulator for Testing Spacecraft Separation Devices

A report describes the main features of a system for testing pyrotechnic and mechanical devices used to separate spacecraft and modules of spacecraft during flight. The system includes a spacecraft simulator [also denoted a large mobility base (LMB)] equipped with air thrusters, sensors, and data-acquisition equipment. The spacecraft simulator floats on air bearings over an epoxy-covered concrete floor. This free-flotation arrangement enables simulation of motion in outer space in three degrees of freedom: translation along two orthogonal horizontal axes and rotation about a vertical axis. The system also includes a static stand. In one application, the system was used to test a bolt-retraction system (BRS) intended for separation of the lifting-body and deorbit-propulsion stages of the X- 38 spacecraft. The LMB was connected via the BRS to the static stand, then pyrotechnic devices that actuate the BRS were fired. The separation distance and acceleration were measured. The report cites a document, not yet published at the time of reporting the information for this article, that is said to present additional detailed information.

Johnston, Nick↗

Backed Bending Actuator

Bending actuators of a proposed type would partly resemble ordinary bending actuators, but would include simple additional components that would render them capable of exerting large forces at small displacements. Like an ordinary bending actuator, an actuator according to the proposal would include a thin rectangular strip that would comprise two bonded layers (possibly made of electroactive polymers with surface electrodes) and would be clamped at one end in the manner of a cantilever beam. Unlike an ordinary bending actuator, the proposed device would include a rigid flat backplate that would support part of the bending strip against backward displacement; because of this feature, the proposed device is called a backed bending actuator. When an ordinary bending actuator is inactive, the strip typically lies flat, the tip displacement is zero, and the force exerted by the tip is zero. During activation, the tip exerts a transverse force and undergoes a bending displacement that results from the expansion or contraction of one or more of the bonded layers. The tip force of an ordinary bending actuator is inversely proportional to its length; hence, a long actuator tends to be weak. The figure depicts an ordinary bending actuator and the corresponding backed bending actuator. The bending, the tip displacement (d(sub t)), and the tip force (F) exerted by the ordinary bending actuator are well approximated by the conventional equations for the loading and deflection of a cantilever beam subject to a bending moment which, in this case, is applied by the differential expansion or contraction of the bonded layers. The bending, displacement, and tip force of the backed bending actuator are calculated similarly, except that it is necessary to account for the fact that the force F(sub b) that resists the displacement of the tip could be sufficient to push part of the strip against the backplate; in such a condition, the cantilever beam would be effectively shortened (length L*) and thereby stiffened and, hence, made capable of exerting a greater tip force for a given degree of differential expansion or contraction of the bonded layers. Taking all of these effects into account, the cantilever-beam equations show that F(sub b) would be approximately inversely proportional to d(sup 1/2) for d less than a calculable amount, denoted the transition displacement (dt). For d less than d(sub t), part of the strip would be pressed against the backplate. Therefore, the force F(sub b) would be very large for d at or near zero and would decrease as d increases toward d(sub t). At d greater than d(sub t), none of the strip would be pressed against the backplate and F(sub b) would equal the tip force F of the corresponding ordinary bending actuator. The advantage of the proposal is that a backed bending actuator could be made long to obtain large displacement when it encountered little resistance but it could also exert a large zero-displacement force, so that it could more easily start the movement of a large mass, throw a mechanical switch, or release a stuck mechanism.

Costen, Robert C.↗

Towards Prognostics of Electrolytic Capacitors

A remaining useful life prediction algorithm and degradation model for electrolytic capacitors is presented. Electrolytic capacitors are used in several applications ranging from power supplies on critical avionics equipment to power drivers for electro-mechanical actuators. These devices are known for their low reliability and given their criticality in electronics subsystems they are a good candidate for component level prognostics and health management research. Prognostics provides a way to assess remaining useful life of a capacitor based on its current state of health and its anticipated future usage and operational conditions. In particular, experimental results of an accelerated aging test under electrical stresses are presented. The capacitors used in this test form the basis for a remaining life prediction algorithm where a model of the degradation process is suggested. This preliminary remaining life prediction algorithm serves as a demonstration of how prognostics methodologies could be used for electrolytic capacitors.

Celaya, Jose R.↗

Towards A Model-Based Prognostics Methodology for Electrolytic Capacitors: A Case Study Based on Electrical Overstress Accelerated Aging

A remaining useful life prediction methodology for electrolytic capacitors is presented. This methodology is based on the Kalman filter framework and an empirical degradation model. Electrolytic capacitors are used in several applications ranging from power supplies on critical avionics equipment to power drivers for electro-mechanical actuators. These devices are known for their comparatively low reliability and given their criticality in electronics subsystems they are a good candidate for component level prognostics and health management. Prognostics provides a way to assess remaining useful life of a capacitor based on its current state of health and its anticipated future usage and operational conditions. We present here also, experimental results of an accelerated aging test under electrical stresses. The data obtained in this test form the basis for a remaining life prediction algorithm where a model of the degradation process is suggested. This preliminary remaining life prediction algorithm serves as a demonstration of how prognostics methodologies could be used for electrolytic capacitors. In addition, the use degradation progression data from accelerated aging, provides an avenue for validation of applications of the Kalman filter based prognostics methods typically used for remaining useful life predictions in other applications.

Celaya, Jose R.↗

A Model-based Prognostics Methodology for Electrolytic Capacitors Based on Electrical Overstress Accelerated Aging

A remaining useful life prediction methodology for electrolytic capacitors is presented. This methodology is based on the Kalman filter framework and an empirical degradation model. Electrolytic capacitors are used in several applications ranging from power supplies on critical avionics equipment to power drivers for electro-mechanical actuators. These devices are known for their comparatively low reliability and given their criticality in electronics subsystems they are a good candidate for component level prognostics and health management. Prognostics provides a way to assess remaining useful life of a capacitor based on its current state of health and its anticipated future usage and operational conditions. We present here also, experimental results of an accelerated aging test under electrical stresses. The data obtained in this test form the basis for a remaining life prediction algorithm where a model of the degradation process is suggested. This preliminary remaining life prediction algorithm serves as a demonstration of how prognostics methodologies could be used for electrolytic capacitors. In addition, the use degradation progression data from accelerated aging, provides an avenue for validation of applications of the Kalman filter based prognostics methods typically used for remaining useful life predictions in other applications.

Electrolytic capacitors↗

Propulsion Wheel Motor for an Electric Vehicle

A wheel assembly for an electric vehicle includes a wheel rim that is concentrically disposed about a central axis. A propulsion-braking module is disposed within an interior region of the wheel rim. The propulsion-braking module rotatably supports the wheel rim for rotation about the central axis. The propulsion-braking module includes a liquid cooled electric motor having a rotor rotatable about the central axis, and a stator disposed radially inside the rotor relative to the central axis. A motor-wheel interface hub is fixedly attached to the wheel rim, and is directly attached to the rotor for rotation with the rotor. The motor-wheel interface hub directly transmits torque from the electric motor to the wheel rim at a 1:1 ratio. The propulsion-braking module includes a drum brake system having an electric motor that rotates a cam device, which actuates the brake shoes.

Figuered, Joshua M.↗

Launch Lock Assemblies with Reduced Preload and Spacecraft Isolation Systems Including the Same

Launch lock assemblies with reduced preload are provided. The launch lock assembly comprises first and second mount pieces, a releasable clamp device, and a pair of retracting assemblies. Each retracting assembly comprises a pair of toothed members having interacting toothed surfaces. The releasable clamp device normally maintains the first and second mount pieces in clamped engagement. When the releasable clamp device is actuated, the first and second mount pieces are released from clamped engagement and one toothed member of each retracting assembly moves in an opposite direction relative to the other one toothed member of the other retracting assembly to define an axial gap on each side of the first mount piece.

Barber, Tim Daniel↗

Electrical sensing, tracking, and actuation of droplets

Devices, techniques, and processes are disclosed that use electrical impedance to detect of the presence and contents of droplets including cells, nucleic acids, proteins, or solute concentrations in an array of retrievable, trackable, trapped droplets in a fluidic system. Electrodes may be positioned underneath individual droplet traps in a microchannel to assay droplet contents and/or actuating droplets for the release of the droplets from corresponding traps. The disclosed technology may be used for detection of the results of solvent extraction processes including time-dependent quantification of metal ion concentration in the aqueous and organic phases, for wastewater treatment, heavy metal detection, pharmaceutical industry, and/or biotechnology, or for environmental monitoring of wastewater for toxic metal, monitoring of biological cell viability and proliferation, monitoring of extraction processes used in heavy metal mining, monitoring of extraction processes used in nuclear fuel processing, monitoring kinetics of enzyme processes, and/or assessing pharmacodynamics and drug efficacy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hand Held Device for Wireless Powering and Interrogation of Biomems Sensors and Actuators

A compact, hand-held device for wireless powering, interrogation and data retrieval from at least one implanted sensor. The hand-held device includes an antenna for powering an implanted sensor and for receiving data from the implanted sensor to the hand-held device for at least one of storage, display or analysis. The hand-held device establishes electromagnetic coupling with a low radiating radio frequency power inductor in the implanted sensor at a predefined separation and the antenna geometry allows for the antenna to power, interrogate and retrieve data from the implanted sensor without strapping the hand-held device to a human body housing the implanted sensor The hand-held device optionally allows for activation of the implanted sensor only during interrogation and data retrieval.

Miranda, Felix Antonio↗

Cyclical biodirectional rotary actuator

Thermally powered device flips magnetometer between one of two positions located 180 deg apart and permits instrument calibration. Pair of heat-extensible springs selectively rotate shaft from one position to other when electric heaters bonded to them are energized.

Stange, W. C.↗

Two-Fault-Tolerant Release Mechanism

Remotely-operated, compact quick-release mechanism still functions in event that one or even two attempts to actuate it fail. Contains three independent pyrotechnic devices. Firing of any one of devices sufficient to actuate mechanism. Three pins hold toggle at its base. Retraction of any one of pins allows toggle head to rotate in spherical bearing to free itself from remaining pin or pins. Besides allowing rotation after retraction, bearing also aligns toggle during assembly.

Graves, Thomas J.↗

Reflectivity Control Device (RCD) Roll Momentum Management for Solar Cruiser and Beyond

Reflectivity control devices (RCDs), thin film optical devices that are actuated (by application of a voltage across the device) to control the reflection of sunlight on their surfaces, can effectively enable roll momentum management (MM) of a solar sail operating in deep space, outside any magnetic field. This enables solar sails to maintain adequate attitude control in these challenging environments without sacrificing mission life by using expendables. They were planned and developed for use on Solar Cruiser, operating sunward of the Sun-Earth Lagrange Point 1 (sub-L1) in a propulsion-intensive artificial halo orbit. Located in pairs of panels near the distal end of each of four booms, each articulated at a slight angle out of the sail plane to produce a force tangent to the sail at a large moment arm, the RCDs provide roll torque capabilities by using simple switching logic to determine which panels should be activated (voltage applied) to produce torque in the desired direction. The performance capabilities and constraints of these devices across a range of operating conditions, namely sun-relative attitude, is well characterized, granting designers insight on how to properly size the system and optimize the system and component designs to maximize roll torque per unit area. With an informed design, RCDs can be very effective actuators for managing roll momentum with minimal detrimental system impacts (mass, power, complexity, etc.) on Solar Cruiser and other future deep space solar sail missions.

Andrew F Heaton↗