Search NASA⌕ Search

SEARCH · Search NASA

Results for “advanced metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Mapping the Upper Subsurface of MARS Using Radar Polarimetry

Future human exploration of Mars will require detailed knowledge of the surface and upper several meters of the subsurface in potential landing sites. Likewise, many of the Planetary Science Decadal Survey science goals, such as understanding the history of Mars climate change, determining how the surface was altered through processes like volcanism and fluvial activity, and locating regions that may have been hospitable to life in the past, would be significantly advanced through mapping of the upper meters of the surface. Synthetic aperture radar (SAR) is the only remote sensing technique capable of penetrating through meters of material and imaging buried surfaces at high (meters to tens-of-meters) spatial resolution. SAR is capable of mapping the boundaries of buried units and radar polarimetry can provide quantitative information about the roughness of surface and subsurface units, depth of burial of stratigraphic units, and density of materials. Orbital SAR systems can obtain broad coverage at a spatial scale relevant to human and robotic surface operations. A polarimetric SAR system would greatly increase the safety and utility of future landed systems including sample caching.

Carter, L. M.↗

A study of orbit determination accuracies for future earth observatory missions

It is anticipated that global orbital accuracies of 10 meters will be required for future earth observatory missions. Results are presented of a study of the LANDSAT-1 orbit to determine position accuracies obtainable today so as to assess what future advancements are necessary to meet a 10-meter goal. Accuracies of 50 meters were determined to be achievable now from two-day tracking arcs. One-half-day arcs yield accuracies of about 30 meters. The dominant error source was found to be geopotential model uncertainty. All other systematic errors produced less than 10 meters total position error.

Bryant, W. C., Jr.↗

On data-driven energy flexibility quantification: A framework and case study

Building energy flexibility is an important resource for a sustainable and resilient power grid, and an important measure to reduce utility costs for building owners. Quantifying energy flexibility for existing buildings can provide critical insights in optimizing their operation. Data-driven methods for building energy modeling and analytics are gaining popularity due to the increasingly available sensor and meter infrastructure, affordable computational resources, and advanced modeling algorithms. However, their application in quantifying the energy flexibility of real buildings is still limited due to the heterogeneous data types and limited data availability. Here, this study proposes a framework for building-level data-driven energy flexibility quantification that considers different levels of data availability and use cases. Two case studies with real building data collected at different scales were conducted to demonstrate the proposed framework for different purposes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A tool for assessing demand side management and operating strategies for isolated microgrids

Globally, power system operators are exploring ways to leverage the capabilities of smart meters to implement fine-grained demand side management (DSM). Here this paper presents a new simulation tool to evaluate operating strategies for smart-meter-enabled (SME) islanded microgrids being advanced for sustainable rural electrification in emerging economies. Based on MATLAB/Simulink, the tool's component-level models of small microgrids can be easily configured. Alternative rule-based operating strategies are implemented with controllable supply and storage components as well as other components driven by external factors (e.g., weather and time of day). To account for the wide range of possible operating conditions in real-world applications, statistical metrics can be evaluated using Monte Carlo (MC) methods based on user-defined, time-dependent probability distributions for demands, supplies, and environmental variables. Features of the tool are demonstrated with case studies for a representative microgrid in rural Rwanda.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SFAI and Related Technologies

Researchers at Los Alamos have developed Swept-Frequency Acoustic Interferometry (SFAI) a technology that enables businesses to have greater control over their industrial processes, allowing for significantly improved efficiency by giving operators vital composition and flow rate information in real-time. This technology fills the information gap by providing this data non-invasively and at a fraction of the cost of traditional composition meters. SFAI uses engineered ultrasound and advanced signal processing to characterize multiphase flow (e.g., liquids, gasses, multi-phase mixtures) and other flows inside sealed containers and flow pipes. By being both low-cost and non-invasive, this technology is set to disrupt the current oil field monitoring state-of-the-art by providing individual well-level composition data, compared to the multi-well macroscopic information that is currently available. We are seeking a commercialization partner to license the technology or fund us through a Cooperative Research and Development Agreement (CRADA) to a further develop a usable product for commercial purposes.

03 NATURAL GAS↗

Remote Sensing of Atlanta's Urban Sprawl and the Distribution of Land Cover and Surface Temperatures

Between 1973 and 1992, an average of 20 ha of forest was lost each day to urban expansion of Atlanta, Georgia. Urban surfaces have very different thermal properties than natural surfaces-storing solar energy throughout the day and continuing to release it as sensible heat well after sunset. The resulting heat island effect serves as catalysts for chemical reactions from vehicular exhaust and industrialization leading to a deterioration in air quality. In this study, high spatial resolution multispectral remote sensing data has been used to characterize the type, thermal properties, and distribution of land surface materials throughout the Atlanta metropolitan area. Ten-meter data were acquired with the Advanced Thermal and Land Applications Sensor (ATLAS) on May 11 and 12, 1997. ATLAS is a 15-channel multispectral scanner that incorporates the Landsat TM bands with additional bands in the middle reflective infrared and thermal infrared range. The high spatial resolution permitted discrimination of discrete surface types (e.g., concrete, asphalt), individual structures (e.g., buildings, houses) and their associated thermal characteristics. There is a strong temperature contrast between vegetation and anthropomorphic features. Vegetation has a modal temperature at about 20 C, whereas asphalt shingles, pavement, and buildings have a modal temperature of about 39 C. Broad-leaf vegetation classes are indistinguishable on a thermal basis alone. There is slightly more variability (plus or minus 5 C) among the urban surfaces. Grasses, mixed vegetation and mixed urban surfaces are intermediate in temperature and are characterized by broader temperature distributions with modes of about 29 C. Thermal maps serve as a basis for understanding the distribution of "hotspots", i.e., how landscape features and urban fabric contribute the most heat to the lower atmosphere.

Laymon, Charles A.↗

Remote Sensing of Atlanta's Urban Sprawl and the Distribution of Land Cover and Surface Temperature

Between 1973 and 1992, an average of 20 ha of forest was lost each day to urban expansion of Atlanta, Georgia. Urban surfaces have very different thermal properties than natural surfaces-storing solar energy throughout the day and continuing to release it as sensible heat well after sunset. The resulting heat island effect serves as catalysts for chemical reactions from vehicular exhaust and industrialization leading to a deterioration in air quality. In this study, high spatial resolution multispectral remote sensing data has been used to characterize the type, thermal properties, and distribution of land surface materials throughout the Atlanta metropolitan area. Ten-meter data were acquired with the Advanced Thermal and Land Applications Sensor (ATLAS) on May 11 and 12, 1997. ATLAS is a 15-channel multispectral scanner that incorporates the Landsat TM bands with additional bands in the middle reflective infrared and thermal infrared range. The high spatial resolution permitted discrimination of discrete surface types (e.g., concrete, asphalt), individual structures (e.g., buildings, houses) and their associated thermal characteristics. There is a strong temperature contrast between vegetation and anthropomorphic features. Vegetation has a modal temperature at about 20 C, whereas asphalt shingles, pavement, and buildings have a modal temperature of about 39 C. Broad-leaf vegetation classes are indistinguishable on a thermal basis alone. There is slightly more variability (+/-5 C) among the urban surfaces. Grasses, mixed vegetation and mixed urban surfaces are intermediate in temperature and are characterized by broader temperature distributions with modes of about 29 C. Thermal maps serve as a basis for understanding the distribution of "hotspots", i.e., how landscape features and urban fabric contribute the most heat to the lower atmosphere.

Laymon, Charles A.↗

Stability and control results for advanced turboprop aft-mount installations

An experimental investigation was recently conducted in the NASA-Langley Research Center 4- by 7-Meter Tunnel to explore the effects of aft-mounted advanced turboprop installations on the low-speed stability and control characteristics of a representative transport aircraft configuration. For the conditions investigated, the experimental results indicate that the longitudinal and directional stability of the configuration was not adversely affected by aft-pylon-mounted single-rotation tractor or counter-rotation pusher propeller installations. The results indicate that for the single-rotation tractor configuration the propeller induced aerodynamics are dominated by the interaction of the propeller slipsteam with the pylon, and that the propeller contribution to the stability characteristics for the counter-rotating pusher configuration is dominated by propeller normal forces. The longitudinal and directional control effectiveness, engine-out characteristics, and ground effects are also presented.

Coe, P. L., Jr.↗

Pressure distributions from high Reynolds number tests of a Boeing BAC 1 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

A wind-tunnel investigation designed to test a Boeing advanced-technology airfoil from low to flight-equivalent Reynolds numbers has been completed in the Langley 0.3-Meter Transonic Cryogenic Tunnel. This investigation represents the first in a series of NASA/U.S. industry two-dimensional airfoil studies to be completed in the Advanced Technology Airfoil Test program. Test temperature was varied from ambient to about 100 K at pressures ranging from about 1.2 to 6.0 atm. Mach number was varied from about 0.40 to 0.80. These variables provided a Reynolds number (based on airfoil chord) range from 4.4 X 10 to the 6th power to 50.0 X 10 to the 6th power. All the test objectives were met. The pressure data are presented without analysis in plotted and tabulated formats for use in conjunction with the aerodynamic coefficient data published as NASA TM-81922. At the time of the test, these pressure data were considered proprietary and have only recently been made available by Boeing for general release. Data are included which demonstrate the effects of fixed transition. Also included are remarks on the model design, the model structural integrity, and the overall test experience.

Johnson, W. G., Jr.↗

Analysis of Conservation Voltage Reduction under Inverter-Based VAR-Support [Slides]

Conservation voltage reduction (CVR) is a common technique used by utilities to strategically reduce demand during peak periods. As penetration levels of distributed generation (DG) continue to rise and advanced inverter capabilities become more common, it is unclear how the effectiveness of CVR will be impacted and how CVR interacts with advanced inverter functions. In this work, we investigated the mutual impacts of CVR and DG from photovoltaic (PV) systems (with and without autonomous Volt-VAR enabled). The analysis was conducted on an actual utility dataset, including a feeder model, measurement data from smart meters and intelligent reclosers, and metadata for more than 30 CVR events triggered by the utility over the year. The installed capacity of the modeled PV systems represented 66% of peak load, but reached instantaneous penetrations reached up to 2.5x the load consumption over the year. While the objectives of CVR and autonomous Volt-VAR are opposed to one another, this study found that their interactions were mostly inconsequential since the CVR events occurred when total PV output was low.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A digital twin platform for building performance monitoring and optimization: Performance simulation and case studies

Advancements in sensor technology, data analytics, affordable compute, and communication infrastructure have paved the way for Digital Twin technology in optimizing building operations and controls. This study presents the development of an open and interoperable web-based Digital Twin platform for integrating diverse data streams and facilitating effective user interactions. The platform utilizes modern technologies for the web framework and time-series data management, ensuring scalability and responsiveness. The backend supports seamless integration of diverse data sources and emulators, incorporating data from building sensors and meters, external weather Application Programming Interfaces, and advanced EnergyPlus simulation models of the building and its energy systems including the Distributed Energy Resources that are formulated in Functional Mockup Units. A simulation case study was conducted with FlexLab, a test facility on Lawrence Berkeley National Laboratory campus. The case study includes normal operations, Distributed Energy Resource integration, and power outage scenarios, to illustrate the Digital Twin’s ability to provide critical insights into energy performance and thermal resilience. The results demonstrated the platform’s potential as a decision-support tool for optimizing building energy performance and enhancing resilience against extreme weather events. Future work will focus on deploying the Digital Twin platform to a real building for field validation, extending its capabilities to cover more scenarios such as bidirectional Electric Vehicle interactions, and enhancing user engagement.

EnergyPlus↗

A Comparison of Interactional Aerodynamics Methods for a Helicopter in Low Speed Flight

Recent advances in computing subsonic flow have been applied to helicopter configurations with various degrees of success. This paper is a comparison of two specific methods applied to a particularly challenging regime of helicopter flight, very low speeds, where the interaction of the rotor wake and the fuselage are most significant. Comparisons are made between different methods of predicting the interactional aerodynamics associated with a simple generic helicopter configuration. These comparisons are made using fuselage pressure data from a Mach-scaled powered model helicopter with a rotor diameter of approximately 3 meters. The data shown are for an advance ratio of 0.05 with a thrust coefficient of 0.0066. The results of this comparison show that in this type of complex flow both analytical techniques have regions where they are more accurate in matching the experimental data.

Berry, John D.↗

A Comparison of Interactional Aerodynamics Methods for a Helicopter in Low Speed Flight

Recent advances in computing subsonic flow have been applied to helicopter configurations with various degrees of success. This paper is a comparison of two specific methods applied to a particularly challenging regime of helicopter flight, very low speeds, where the interaction of the rotor wake and the fuselage are most significant. Comparisons are made between different methods of predicting the interactional aerodynamics associated with a simple generic helicopter configuration. These comparisons are made using fuselage pressure data from a Mach-scaled powered model helicopter with a rotor diameter of approximately 3 meters. The data shown are for an advance ratio of 0.05 with a thrust coefficient of 0.0066. The results of this comparison show that in this type of complex flow both analytical techniques have regions where they are more accurate in matching the experimental data.

Berry, John D.↗

Advanced Manufacturing of High-Performance Superconductor Wires for Next Generation Electric Machines

While the transition of RE-Ba-Cu-O (REBCO, RE = rare earth) wires from lab-scale to initial manufacturing demonstrations has been accomplished, the high manufacturing cost is a major impediment to a commercial market. At the onset of this project, commercial REBCO wires exhibiting a critical current of ~ 340 A/cm at 65 K, 1.5T (operating condition of superconducting rotating machines targeted in this project) costed about $\$$300/kA-m which is well above the cost of copper wire. In this project, the UH-led team employed multiple innovative techniques to meet the aggressive performance and cost targets established. The key technology that was developed in this project was advanced metal organic chemical vapor deposition (MOCVD) to fabricate REBCO wires with films as thick as 5 µm and with excellent critical current performance at 65 K, 1.5 T. In addition to excellent performance in short samples, a major accomplishment of this project was to scale up the Advanced MOCVD technology to lengths of 50 meters while maintaining the superior critical current. Multiple 50-m-long tapes were demonstrated in the project with uniform critical current, that confirmed the viability of our technology for industrial manufacturing. Beyond scaling up our technology to long lengths, we worked with our industrial partners to design a REBCO-based motor coil, constructed one such coil and fabricated it using long tapes made in this project. This motor coil was successfully tested at 77 K and 65 K which affirmed the viability of high-performance REBCO wires made in this work for industrial applications. In addition to high critical current, we also demonstrated >4x precursor-to-film conversion efficiency in the advanced MOCVD process which has a first order impact on wire cost.

36 MATERIALS SCIENCE↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The promise of advanced technology for future air transports

Progress in all weather 4-D navigation and wake vortex attenuation research is discussed and the concept of time based metering of aircraft is recommended for increased emphasis. The far term advances in aircraft efficiency were shown to be skin friction reduction and advanced configuration types. The promise of very large aircraft, possibly all wing aircraft is discussed, as is an advanced concept for an aerial relay transportation system. Very significant technological developments were identified that can improve supersonic transport performance and reduce noise. The hypersonic transport was proposed as the ultimate step in air transportation in the atmosphere. Progress in the key technology areas of propulsion and structures was reviewed. Finally, the impact of alternate fuels on future air transports was considered and shown not to be a growth constraint.

Bower, R. E.↗

Guest Editorial: Advanced Data-Analytics for Power System Operation, Control, and Enhanced Situational Awareness

Along with the smart grid development, modern power systems are entering a ‘data-intensive’ era. A vast volume of data from power grids is being collected through advanced sensing and communication technologies, such as smart metering data, phasor measurement data, as well as meteorological data (e.g., wind speed and solar irradiance) related to renewable power generation. Such data contains comprehensive information about the power system covering equipment's health status, power grid's static and dynamic characteristics, renewable power generation, customers’ electricity usage pattern, etc. Therefore, advanced data-analytics techniques are needed to convert such data to knowledge for practical applications. In line with the trend of widespread data-driven applications in power systems, this Special Issue aims to present state-of-the-art research works on advanced data-analytics for power system's operation, control, and situational awareness. There are in total twenty-six papers accepted for publication in this Special Issue through careful peer reviews and revisions. Under the overarching theme of data-driven applications in power systems, the selected papers are broadly categorised into five topics. The summary of every topic is given below. You are, however, strongly encouraged to read the full paper if interested.

Xu, Yan↗