Search NASA⌕ Search

SEARCH · Search NASA

Results for “air pollution exposure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Small Particle Pollutants

NASA and the EPA are cooperating to measure particle size of all elements in aerosols from airports, coal-fired power stations, municipal waste incinerators, and other combustion aerosol sources. Langley intends to sample the air using its proton-induced x-ray emission technique initially developed to determine aerosols in jet-engine exhaust. Proton technique is important because no other rapid, nondestructive method now exists for measuring trace element compositions of massive amounts of air. Method can also analyze human tissue and hair samples to determine exposure to toxic elements.

Source record↗

Space Station atmospheric monitoring systems

A technology assessment study on atmospheric monitoring systems was performed by Battelle Columbus Division for the National Aeronautics and Space Administration's John F. Kennedy Space Center under Contract No. NAS 10-11033. In this assessment, the objective was to identify, analyze, and recommend systems to sample and measure Space Station atmospheric contaminants and identify where additional research and technology advancements were required. To achieve this objective, it was necessary to define atmospheric monitoring requirements and to assess the state of the art and advanced technology and systems for technical and operational compatibility with monitoring goals. Three technical tasks were defined to support these needs: Definition of Monitoring Requirements, Assessment of Sampling and Analytical Technology, and Technology Screening and Recommendations. Based on the analysis, the principal candidates recommended for development at the Space Station's initial operational capability were: (1) long-path Fourier transform infrared for rapid detection of high-risk contamination incidences, and (2) gas chromatography/mass spectrometry utilizing mass selective detection (or ion-trap) technologies for detailed monitoring of extended crew exposure to low level (ppbv) contamination. The development of a gas chromatography/mass spectrometry/matrix isolation-Fourier transform infrared system was recommended as part of the long range program of upgrading Space Station trace-contaminant monitoring needs.

Air Pollution, Indoor/analysis↗

Radiological Impact of 2024 Operations at the Savannah River Site

This report presents the environmental dose assessment methods and the estimated potential doses to the public from 2024 Savannah River Site (SRS) air and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios, such as the consumption of wildlife or goat milk.

54 ENVIRONMENTAL SCIENCES↗

Development of ASTM International D8405—Standard Test Method for Evaluating PM 2.5 Sensors or Sensor Systems Used in Indoor Applications

Sensors and sensor systems for monitoring fine particles with aerodynamic diameters smaller than 2.5 µm can provide real-time feedback on indoor air quality and thus can help guide actions to manage indoor air pollutant concentrations. Standardized verification of the performance and accuracy of sensors and sensor systems is crucial for predicting the efficacy of such monitoring. A new ASTM International standard test method (ASTM D8405) was created for this need and is the most exacting laboratory protocol published to date for evaluating indoor air quality sensors and sensor systems measuring particles smaller than 2.5 µm in diameter. ASTM D8405 subjects sensors and sensor systems to five test phases: (1) an initial particle concentration ramp; (2) exposure to various temperature and humidity conditions; (3) exposure to interfering particles; (4) temperature cycling; and (5) a final particle concentration ramp to assess drift. This paper discusses the development of the standard test method, key aspects of the testing process, example evaluation results, and a comparison of this standard test method against peer evaluation protocols.

47 OTHER INSTRUMENTATION↗

Surface reservoirs dominate dynamic gas-surface partitioning of many indoor air constituents

Human health is affected by indoor air quality. One distinctive aspect of the indoor environment is its very large surface area that acts as a poorly characterized sink and source of gas-phase chemicals. In this work, air-surface interactions of 19 common indoor air contaminants with diverse properties and sources were monitored in a house using fast-response, on-line mass spectrometric and spectroscopic methods. Enhanced-ventilation experiments demonstrate that most of the contaminants reside in the surface reservoirs and not, as expected, in the gas phase. They participate in rapid air-surface partitioning that is much faster than air exchange. Phase distribution calculations are consistent with the observations when assuming simultaneous equilibria between air and large weakly polar and polar absorptive surface reservoirs, with acid-base dissociation in the polar reservoir. Chemical exposure assessments must account for the finding that contaminants that are fully volatile under outdoor air conditions instead behave as semivolatile compounds indoors.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Optical Sensors Based on Single Arm Thin Film Waveguide Interferometer

Single-arm double-mode double-order optical waveguide interferometer utilizes interference between two propagating modes of different orders. Sensing effect results from the change in propagation conditions of the modes caused by the environment. The waveguide is made as an open asymmetric slab structure containing a dye-doped polymer film onto a fused quartz substrate. It is more sensitive to the change of environment than its conventional polarimetric analog using orthogonal modes (TE and TM) of the same order. The sensor still preserves the option of operating in polarimetric regime using a variety of mode combinations such as TE(sub 0)/TM(sub 0) (conventional), TE(sub 0)/TM(sub 1), TE(sub 1)/TM(sub 0), or TE(sub 1)/TM(sub 1) but can also work in nonpolarimetric regime using combinations TE(sub 0)/TM(sub 1) or TE(sub 0)/TM(sub 1). Utilization of different mode combinations simultaneously makes the device more versatile. Application of the sensor to gas sensing is based on doping polymer film with an organic indicator dye sensitive to a particular gas. Change of optical absorption spectrum of the dye caused by the gaseous pollutant results change of the reactive index of the dye-doped polymer film that can be detected by the sensor. As an indicator dyes, we utilize Bromocresol Purple doped into polymer poly(methyl) methacrylate, which shows a reversible growth of the absorption peak neat 600 nm after exposure to wet ammonia. We have built a breadboard prototype of the sensor with He-Ne laser as a light source and with a single mode fiber input and a multimode fiber output. The prototype showed sensitivity to temperature change of the order of 2 C per one full oscillation of the signal. The sensitivity of the sensor to the presence of wet ammonia is 200 ppm per one full oscillation of the signal. The further improvements include switching to a longer wavelength laser source (750-nm semiconductor laser), substitution of poly(methyl) methacrylate with hydrophilic high-temperature polyimide, and increase the doping rate of indicator dye. All these improvements are expected to bring sensitivity to 10 ppm of ammonia per one full oscillation of signal independent on the humidity of ambient air. The proposed sensor can be used as a robust and inexpensive stand-alone instrument for continuous environment pollution monitoring.

Sarkisov, S. S.↗

Updated Application of Frequency of Detection Methods for the INL Site Ambient Air Monitoring Network

This report presents a quantitative assessment of the current INL Site air monitoring network using frequency of detection (FD) methods. The first assessment of the INL network was performed in 2015 and made recommendations for improving the network. As a result of changes made in response to the recommendations and the addition of new source locations, the network was modified and reassessed in 2017. Since 2017, administration of the air sampling program has been consolidated under one contractor, which resulted in additional changes to the network (sampler numbers and locations) and changes in radionuclide detection levels. As a result of these changes and others, an updated assessment of the INL Site ambient air monitoring network was performed. The same two exposure scenarios used in previous assessments were used for this assessment: a resident scenario and a shepherd/rancher scenario. The resident was assumed to be continuously present at their residence/business/farm operation outside the INL Site boundary while the shepherd/rancher was assumed to be present 24-hours at the nearest INL grazing allotment boundary in each of the 22.5-degree sectors along the sector centerline from each source. Updates to both the resident and shepherd/rancher receptor locations were included. Other changes include updates to flow rates for stack sources, expansion of the list of important radionuclides based on the most recent National Emission Standards for Hazardous Pollutants (NESHAPs) analysis, and updated dose coefficients. The assessment was conducted to determine whether the current INL monitoring network is capable of detecting releases of important radionuclides from INL Site sources that have the potential to exceed a conservative dose threshold for the two exposure scenarios. The assessment revealed that for the resident scenario, the current network meets the desired performance objective (FD = 95%) for all radionuclides and sources except for Cl-36 from the TRA-770 stack (94.4%). For the shepherd/rancher scenario, the FD performance objective is met for all radionuclides and sources except tritium from MFC-774 and TAN 679 (91% for both). An investigation of reported emissions for the past three years revealed that Cl 36 is not emitted from TRA-770, and routine tritium emissions from MFC-774 and TAN-679 are very small and the sources are likely incapable of emitting enough tritium to cause a release that should be detectable by the monitoring network. This assessment is based on a conservative dose threshold. This coupled with fact that the FD for Cl 36 is only slightly less than the performance objective and Cl-36 is not emitted from TRA-770, modifying the network (i.e. adding another sampler, increasing sampler flow rate, moving samplers) to meet the 95% performance objective for this radionuclide/source/receptor scenario is not warranted. Similarly, because tritium emissions from MFC-774 and TAN-679 are very small and these two sources are likely incapable of causing a dose due to tritium release that should be detectable by the network, modifications to increase tritium detection for these sources is also unwarranted at this time. However, if it is required to meet the performance objective for tritium for all sources and receptor scenarios, additional analysis determined the FD could be raised from 91% to > 99% for both sources by adding two tritium samplers to the network.

61 RADIATION PROTECTION AND DOSIMETRY↗

Estimation of Daily PM(sub 10) Concentrations in Italy (2006-2012) Using Finely Resolved Satellite Data, Land Use Variables and Meteorology

Health effects of air pollution, especially particulate matter (PM), have been widely investigated. However, most of the studies rely on few monitors located in urban areas for short-term assessments, or land use/dispersion modelling for long-term evaluations, again mostly in cities. Recently, the availability of finely resolved satellite data provides an opportunity to estimate daily concentrations of air pollutants over wide spatio-temporal domains. Italy lacks a robust and validated high resolution spatio-temporally resolved model of particulate matter. The complex topography and the air mixture from both natural and anthropogenic sources are great challenges difficult to be addressed. We combined finely resolved data on Aerosol Optical Depth (AOD) from the Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm, ground-level PM10measurements, land-use variables and meteorological parameters into a four-stage mixed model framework to derive estimates of daily PM10concentrations at 1-km2 grid over Italy, for the years 2006-2012. We checked performance of our models by applying 10-fold cross-validation (CV) for each year. Our models displayed good fitting, with mean CV-R2=0.65 and little bias (average slope of predicted VS observed PM10=0.99). Out-of-sample predictions were more accurate in Northern Italy (Po valley) and large conurbations (e.g. Rome), for background monitoring stations, and in the winter season. Resulting concentration maps showed highest average PM10levels in specific areas (Po river valley, main industrial and metropolitan areas) with decreasing trends over time. Our daily predictions of PM10concentrations across the whole Italy will allow, for the first time, estimation of long-term and short-term effects of air pollution nationwide, even in areas lacking monitoring data. Copyright © 2016 Elsevier Ltd. All rights reserved.

Particulate Matter/analysis↗

The impact of urban configuration types on urban heat islands, air pollution, CO 2 emissions, and mortality in Europe: a data science approach

The world is becoming increasingly urbanized. As cities around the world continue to grow, it is important for urban planners and policymakers to understand how different urban configuration patterns affect the environment and human health. We aimed at identifying European urban configuration types, based on the Local Climate Zones categories and street design variables from Open Street Map, and evaluating their association with motorized traffic flows, Surface Urban Heat Island (SUHI) intensities, tropospheric nitrogen dioxide (NO 2 ), CO 2 per capita emissions and age-standardized mortality. We considered 946 European cities from 31 countries for the analysis defined in the 2018 Urban Audit database, of which 919 European cities were analysed. Data were collected at a 250 m × 250 m grid cell resolution. We divided all cities into five concentric rings based on the Burgess concentric urban planning model and calculated the mean values of all variables for each ring. First, to identify distinct urban configuration types, we applied the Uniform Manifold Approximation and Projection for Dimension Reduction method, followed by the k-means clustering algorithm. Next, statistical differences in exposures (including SUHI) and mortality between the resulting urban configuration types were evaluated using a Kruskal–Wallis test followed by a post-hoc Dunn's test. We identified four distinct urban configuration types characterising European cities: compact high density (n=246), open low-rise medium density (n=245), open low-rise low density (n=261), and green low density (n=167). Compact high density cities were a small size, had high population densities, and a low availability of natural areas. In contrast, green low-density cities were a large size, had low population densities, and a high availability of natural areas and cycleways. The open low-rise medium and low-density cities were a small to medium size with medium to low population densities and low to moderate availability of green areas. Motorised traffic flows and NO 2 exposure were significantly higher in compact high density and open low rise medium density cities when compared with green low density and open low-rise low density cities. Additionally, green low-density cities had a significantly lower SUHI effect compared with all other urban configuration types. Per person CO 2 emissions were significantly lower in compact high density cities compared with green low density cities. Lastly, green low density cities had significantly lower mortality rates when compared with all other urban configuration types. Our findings indicate that, although the compact city model is more sustainable, European compact cities still face challenges related to poor environmental quality and health. Our results have notable implications for urban and transport planning policies in Europe and contribute to the ongoing discussion on which city models can bring the greatest benefits for the environment, climate, and health.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tax Credits for Clean Electricity: The Distributional Impacts of Supply-Push Policies in the Power Sector

We evaluate distributional and efficiency consequences of the bulk power clean electricity tax credits authorized by the 2022 Inflation Reduction Act. To do so, we link detailed electricity capacity expansion, computable general equilibrium, microsimulation, and air pollution models to estimate economic welfare and health incidence across demographic groups. We evaluate trade-offs between policy efficiency and income progressivity by comparing the tax credits to cap-and-trade policies. The tax credits encourage increased clean electricity investment, resulting in a reallocation of capital from elsewhere in the economy, higher prices for capital and other goods, lower power prices, and lower emissions. The tax credits yield progressive outcomes for economic welfare at the expense of efficiency while all modeled policies demonstrate progressivity in health impacts. The health benefits, absent climate benefits, exceed total policy costs and provide greater benefits for low-income and historically marginalized households given coincidence of household locations and emissions exposure intensity.

distributional impacts↗

Development of a Photoacoustic Formaldehyde Monitor

Key indoor air quality pollutant formaldehyde (H2CO) is tracked on International Space Station (ISS) using passive badges returned to the ground periodically for analysis. The process is time-consuming both in preparation and for analysis upon return 6-12 months later. Badges also require precious crew time for deploy, retrieval and stow. As NASA’s focus in space exploration shifts to the Moon and Mars, archival sample return becomes increasingly impractical, so the aim of this project is to develop a highly reliable real-time analyzer for H2CO at low concentrations with data downlinked. Potential sources of H2CO include materials off gassing, use of formalin as a tissue fixative in biological payloads and overheating of acetal polymers. The Spacecraft Maximum Allowable Concentration (SMAC) for H2CO is 100 ppb for exposures of 7 days or longer. ISS concentrations recently run only 10 - 30 ppb but have spiked as high as 60 ppb in the past. Gateway real time monitoring requirements call for a range of 8 - 140 ppb. For this project, a concentration range of 5 - 500 ppb H2CO is targeted. The core tunable diode laser spectroscopy (TDLS) technology was developed by Vista Photonics through the NASA and US Navy Small Business Innovation Research (SBIR) programs. Monitors based on this technology have been demonstrated on ISS, trialed on a nuclear submarine and are in production as Anomaly Gas Analyzers for both ISS and Orion. Initially, direct absorption TDLS was used exclusively in these monitors, however, the H2CO target concentration is much lower, and a longer wavelength required, so a photoacoustic spectroscopy (PAS) technique was adapted, where the laser excitation is detected by a sensitive microphone vs. a conventional photodetector. This paper will discuss the results of NASA-JSC laboratory testing of a prototype PAS based formaldehyde monitor and explore potential adaptations for Gateway missions and beyond.

Paul D Mudgett↗

Quantile-specific heritability of plasma fibrinogen concentrations

Fibrinogen is a moderately heritable blood protein showing different genetic effects by sex, race, smoking status, pollution exposure, and disease status. These interactions may be explained in part by “quantile-dependent expressivity”, where the effect size of a genetic variant depends upon whether the phenotype (e.g. plasma fibrinogen concentration) is high or low relative to its distribution. Determine whether fibrinogen heritability (h 2 ) is quantile-specific, and whether quantile-specific h 2 could account for fibrinogen gene-environment interactions. Plasma fibrinogen concentrations from 5689 offspring-parent pairs and 1932 sibships from the Framingham Heart Study were analyzed. Quantile-specific heritability from offspring-parent (β OP , h 2 = 2β OP /(1+r spouse )) and full-sib regression slopes (β FS , h 2 = {(1+8r spouse β FS ) 0.05 –1}/(2r spouse )) were robustly estimated by quantile regression with nonparametric significance assigned from 1000 bootstrap samples. Quantile-specific h 2 (±SE) increased with increasing percentiles of the offspring’s age- and sex-adjusted fibrinogen distribution when estimated from β OP (P trend = 5.5x10 -6 ): 0.30±0.05 at the 10 th , 0.37±0.04 at the 25 th , 0.48±0.05 at the 50 th , 0.61±0.06 at the 75 th , and 0.65±0.08 at the 90 th percentile, and when estimated from β FS (P trend = 0.008): 0.28±0.04 at the 10 th , 0.31±0.04 at the 25 th , 0.36±0.03 at the 50 th , 0.41±0.05 at the 75 th , and 0.50±0.06 at the 90 th percentile. The larger genetic effect at higher average fibrinogen concentrations may contribute to fibrinogen’s greater heritability in women than men and in Blacks than Whites, and greater increase from smoking and air pollution for the FGB -455G>A A-allele. It may also explain greater fibrinogen differences between: 1) FGB -455G>A genotypes during acute phase reactions than usual conditions, 2) GTSM1 and IL-6 -572C>G genotypes in smokers than nonsmokers, 3) FGB -148C>T genotypes in untreated than treated diabetics, and LPL PvuII genotypes in macroalbuminuric than normoalbuminuric patients. Fibrinogen heritability is quantile specific, which may explain or contribute to its gene-environment interactions. The analyses do not disprove the traditional gene-environment interpretations of these examples, rather quantile-dependent expressivity provides an alternative explanation that warrants consideration.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a Photoacoustic Formaldehyde Monitor

Key indoor air quality pollutant formaldehyde (H 2 CO) is tracked on International Space Station (ISS) using passive badges returned to the ground periodically for analysis. The process is time-consuming both in preparation and for analysis upon return 6-12 months later. Badges also require precious crew time for deploy, retrieval and stow. As NASA’s focus in space exploration shifts to the Moon and Mars, archival sample return becomes increasingly impractical, so the aim of this project is to develop a highly reliable real-time analyzer for H 2 CO at low concentrations with data downlinked. Potential sources of H 2 CO include materials off gassing, use of formalin as a tissue fixative in biological payloads and overheating of acetal polymers. The Spacecraft Maximum Allowable Concentration (SMAC) for H 2 CO in air is 100 ppb for exposures of 7 days or longer. ISS concentrations of H 2 CO are running only 10 - 30 ppb in the recent several years but have spiked as high as 60 ppb. Gateway real time monitoring requirements for H 2 CO call for a range of 8 - 138 ppb. For this project, a concentration range of 5 - 500 ppb H 2 CO is targeted. The core tunable diode laser spectroscopy (TDLS) technology used for this project was developed by Vista Photonics through the NASA and US Navy Small Business Innovation Research (SBIR) programs. Monitors based on TDLS have been demonstrated on ISS, trialed on a nuclear submarine and are being certified as portable Anomaly Gas Analyzers (AGA) for both ISS and Orion. Initially, direct absorption TDLS was used exclusively in these devices. The H 2 CO target concentration, however, is low ppb, and a longer wavelength is required, so a photoacoustic spectroscopy (PAS) technique was adapted, where the laser excitation is detected by a sensitive microphone vs. a conventional photodetector. This paper will discuss the results of NASA-JSC laboratory testing of a prototype PAS based formaldehyde in air monitor and briefly discuss next steps.

Photoacoustic Formaldehyde Monitor↗

Gulf of Mexico Air Quality: CALIPSO Support for Gulf of Mexico Air Quality Relating to the Deepwater Horizon Oil Spill

On April 20, 2010, an oil platform belonging to BP exploded and leaked a huge volume of oil into the Gulf of Mexico. In an effort to control the spread of the oil, BP applied dispersants such as Corexit and conducted in-situ burnings of the oil. This catastrophe created a complex chain of events that affected not only the fragile water and land ecosystems, but the humans who breathe the air every day. Thousands of people were exposed to fumes associated with oil vapors from the spill, burning of the oil, and the toxic mixture of dispersants. While aiding in clean-up efforts, local fishermen were directly exposure to fumes when working on the Gulf. A notable amount of Gulf Coast residents were also exposed to the oil fumes as seasonal southeasterly winds blew vapors toward land. The Volatile Organic Compounds (VOC) found in oil vapors include: benzene, toluene, ethyl benzene, xylene, naphthalene, hydrogen sulfide and particulate matter (PM). Increases in water temperature and sunlight due to the summer season allow for these VOCs and PM to evaporate into the air more rapidly. Aside from the VOCs found in oil vapors, the dispersant being used to break up the oil is highly toxic and is thought to be even more toxic than the oil itself (EPA website, 2010). To protect human health, the environment, and to make informed policy decisions relevant to the spill, the EPA Region 6 has continuously monitored the affected areas carefully for levels of pollutants in the outdoor air that are associated with petroleum products and the burning of oil along the coast. In an effort to prevent, prepare for, and respond to future oil spills that occur in and around inland waters of the United States, the EPA has been working with local, state, and federal response partners. Air quality measurements were collected by the EPA at five active monitoring systems stationed along the coast.

Nguyen, Myngoc T.↗

PurpleAir Sensors as Effective Indicators of PM Exposure in Urban Areas

Particulate matter that is 2.5 microns or less in diameter (PM 2.5 ) is a biproduct of combustion reactions used for energy production. Populations that are exposed to consistently high levels of aerosolized PM 2.5 face serious health risks. This project compared low-cost PM 2.5 sensors with federally recognized methods to look for a cost-effective way to expand the air quality monitor network. Within metropolitan areas that face inconsistent spatial distribution of PM 2.5 , there may not be the necessary network density to indicate neighborhood-levels of PM 2.5 . This project aimed to examine the sensitivity of low-cost PM 2.5 sensor measurements on a neighborhood scale (< 4 km diameter) in an urban area to prevent citizens from being exposed to unsafe levels of PM 2.5 without their knowledge. Using publicly available sensor data from Livermore, CA and Bakersfield, CA, it was determined, based on the revealed patterns, that the analyzed low-cost sensors were able to display representative PM 2.5 levels for neighborhoodscale areas exposed to pollution from PM 2.5 sources.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Impacts of Suppressing Excessive Light Rain on Aerosol Radiative Effects and Health Risks

Global climate models (GCMs) have been used widely to study radiative forcing and health risks of aerosols. A recent study using two GCMs found that light rain plays a dominant role in controlling aerosol loading. However, “too much light rain and too little heavy rain” is a longstanding bias in GCMs. It is unclear how much light rain affects aerosol-cloud-radiation interactions and health risks from air pollution. Here, in this work, we show that, with the correction of the rainfall intensity spectrum in the National Center for Atmospheric Research Community Atmosphere Model version 5.3 by introducing a stochastic deep convection scheme, the reduced frequency of light rain (1–20 mm d -1 ) results in changes of aerosol direct radiative effects (DRE) of up to -0.5 ± 0.03 W/m 2 and aerosol cloud radiative effects (CRE) of up to -0.9 ± 0.03 W/m 2 . The total (CRE + DRE) radiative effects of light rain-mediated aerosol changes exceed the present-day anthropogenic forcing of aerosols relative to preindustrial levels from the Coupled Model Intercomparison Project (CMIP5&6) models. However, the correction of the rainfall intensity spectrum has little effect on anthropogenic aerosol forcing (defined as the radiative perturbation due to changes in aerosol concentrations between the industrial era and preindustrial levels). Due to increased exposure to fine particulates (PM 2.5 ), the estimated global total premature mortality is much higher than previously estimated, by 300,000 ± 60,000 deaths per year, and is more severe in populous regions such as India and China. The findings in this study highlight the need to understand uncertainties in radiative effects and health risks of aerosols due to simulation biases of precipitation in GCMs.

54 ENVIRONMENTAL SCIENCES↗

Computational Fluid Dynamics Simulations to Assess Spatial Variability and Optimal Ventilation Scenarios for Biological Laboratory Exposures

A significant amount of uncertainty exists regarding potential human exposure to laboratory biomaterials and organisms in Biosafety Level 2 (BSL-2) research laboratories. Computational fluid dynamics (CFD) modeling is proposed as a way to better understand potential impacts of different combinations of biomaterials, laboratory manipulations, and exposure routes on risks to laboratory workers. Here, in this study, we use CFD models to simulate airborne concentrations of contaminants in an actual BSL-2 laboratory under different configurations. Results show that ventilation configuration, sampling location, and contaminant source location can significantly impact airborne concentrations and exposures. Depending on the source location and airflow patterns, the transient and time-integrated concentrations varied by several orders of magnitude. Contaminant plumes from sources located near a return vent (or exhaust like a fume hood or ventilated biosafety cabinet) are likely to be more contained than sources that are further from the exhaust. Having a direct flow between the source and the exhaust (through-flow condition) may reduce potential exposures to individuals outside the air flow path. Designing a BSL-2 room with ventilation and airflow patterns that maximize through-flow conditions to the return/exhaust vents and minimize dispersion and mixing throughout the room is, therefore, recommended. CFD simulations can also be used to assist in characterizing the impacts of supply and return vent locations, room layout, and source locations on spatial and temporal contaminant concentrations. In addition, proper placement of particle sensors can also be informed by CFD simulations to provide additional characterization and monitoring of potential exposures in BSL-2 facilities.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Trajectory modeling of emissions from lower stratospheric aircraft

A series of isentropic trajectory calculations has been performed for emissions by stratospheric aircraft moving across the northern midlatitude oceanic flight corridors. Emission of exhaust is simulated by the daily initialization of air parcels along a flight path on the 500 K isentropic surface. Parcels are tracked during the first three weeks of each January from 1980 to 1994 in order to determine the interannual variability in the spatial distribution of the exhaust and the likelihood of exposure to cold temperatures. Few parcels emitted along these flight paths at this time of year had experienced nitric acid trihydrate (NAT) formation temperatures, except for the particularly cold Januarys 1986, 1987, and 1992. Large zonal fluctuations in the distribution of the emissions are typical for this time year and are strongly dependent on flight path. An extended 6-month (January-June) run in which parcels were released daily along the New York-London route shows that emissions in the flight corridor increase at a time-averaged rate which is nearly twice the rate at which the zonal average increases. In addition, local fluctuations of pollutant density can be several times higher than the zonal average and can persist for several weeks. A rapid buildup of emissions occurred during the summer months. These elevated emission levels must be considered in the interpretation of environmental impact assessments based on two-dimensional transport models.

Sparling, Lynn C.↗