Search NASA⌕ Search

SEARCH · Search NASA

Results for “ambient air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A Side by Side Comparison of Filter-Based PM(sub 2.5) Measurements at a Suburban Site: A Closure Study

Reliable determination of the effects of air quality on public health and the environment requires accurate measurement of PM(sub 2.5) mass and the individual chemical components of fine aerosols. This study seeks to evaluate PM(sub 2.5) measurements that are part of a newly established national network by comparing them with a more conventional sampling system. Experiments were carried out during 2002 at a suburban site in Maryland, United States, where two samplers from the U.S. Environmental Protection Agency (USEPA) Speciation Trends Network: Met One Speciation Air Sampling System STNS and Thermo Scientific Reference Ambient Air Sampler STNR, two Desert Research Institute Sequential Filter Samplers DRIF, and a continuous TEOM monitor (Thermo Scientific Tapered Element Oscillating Microbalance) were sampling air in parallel. These monitors differ not only in sampling configuration but also in protocol-specific sample analysis procedures. Measurements of PM(sub 2.5) mass and major contributing species were well correlated among the different methods with r-values > 0.8. Despite the good correlations, daily concentrations of PM(sub 2.5) mass and major contributing species were significantly different at the 95% confidence level from 5 to 100% of the time. Larger values of PM(sub 2.5) mass and individual species were generally reported from STNR and STNS. The January STNR average PM(sub 2.5) mass (8.8 (micro)g/per cubic meter) was 1.5 (micro)g/per cubic meter larger than the DRIF average mass. The July STNS average PM(sub 2.5) mass (27.8 (micro)g/per cubic meter) was 3.8 (micro)g/per cubic meter larger than the DRIF average mass. These differences can only be partially accounted for by known random errors. Variations in flow control, face velocity, and sampling artifacts likely influence the measurement of PM(sub 2.5) speciation and mass closure. Simple statistical tests indicate that the current uncertainty estimates used in the STN network may underestimate the actual uncertainty.

Haines, Jennifer C.↗

Impacts of Estimated Plume Rise on PM 2.5 Exceedance Prediction During Extreme Wildfire Events: A Comparison of Three Schemes (Briggs, Freitas, and Sofiev)

Plume height plays a vital role in wildfire smoke dispersion and the subsequent effects on air quality and human health. In this study, we assess the impact of different plume rise schemes on predicting the dispersion of wildfire air pollution and the exceedances of the National Ambient Air Quality Standards (NAAQS) for fine particulate matter (PM 2.5 ) during the 2020 western United States wildfire season. Three widely used plume rise schemes (Briggs, 1969; Freitas et al., 2007; Sofiev et al., 2012) are compared within the Community Multiscale Air Quality (CMAQ) modeling framework. The plume heights simulated by these schemes are comparable to the aerosol height observed by the Multi-angle Imaging SpectroRadiometer (MISR) and Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO). The performance of the simulations with these schemes varies by fire case and weather conditions. On average, simulations with higher plume injection heights predict lower aerosol optical depth (AOD) and surface PM 2.5 concentrations near the source region but higher AOD and PM 2.5 in downwind regions due to the faster spread of the smoke plume once ejected. The 2-month mean AOD difference caused by different plume rise schemes is approximately 20 %–30 % near the source regions and 5 %–10 % in the downwind regions. Thick smoke blocks sunlight and suppresses photochemical reactions in areas with high AOD. The surface PM 2.5 difference reaches 70 % on the West Coast of the USA, and the difference is lower than 15 % in the downwind regions. Moreover, the plume injection height affects pollution exceedance (>35 µg m−3) predictions. Higher plume heights generally produce larger downwind PM 2.5 exceedance areas. The PM 2.5 exceedance areas predicted by the three schemes largely overlap, suggesting that all schemes perform similarly during large wildfire events when the predicted concentrations are well above the exceedance threshold. At the edges of the smoke plumes, however, there are noticeable differences in the PM 2.5 concentration and predicted PM 2.5 exceedance region. For the whole period of study, the difference in the total number of exceedance days could be as large as 20 d in northern California and 4 d in the downwind regions. This disagreement among the PM 2.5 exceedance forecasts may affect key decision-making regarding early warning of extreme air pollution episodes at local levels during large wildfire events.

Yunyao Li↗

Increased Atmospheric PM 2.5 Events Due to Open Waste Burning in Qaanaaq, Greenland, Summer of 2022

High levels of particulate matter (PM) are relevant to severe air pollution and can adversely impact human health. Maintaining healthy air quality for the residents of the Arctic region is essential to satisfy the no-one-left-behind policy of the Sustainable Development Goals (SDGs) by the United Nations. In this study, we installed a PM 2.5 measurement system in Qaanaaq, Greenland, and obtained the first continuous PM 2.5 measurements from 20 July to 13 August, 2022. We observed several increased PM2.5 events; relatively high PM 2.5 levels persisted from 8 August 2022. On the same day, visible black smoke emitted from the Qaanaaq dump site originated from open waste burning. By confirming less transboundary air pollution contributions from remote aerosol source regions to Qaanaaq during the measurement period using NOAA’s HYSPLIT backward trajectory analysis and NASA’s MERRA-2 aerosol re-analysis, we confirmed that the increased PM 2.5 was primarily due to local open waste burning with less contributions from transboundary air pollution. However, small contributions from biomass burning outside Greenland were plausible during the early measurement period. Additionally, NOAA’s HYSPLIT dispersion calculations suggested possible aerosol depositions from local open waste burning to nearby sea areas, such as Baffin Bay. Although the hourly mean PM 2.5 mass concentration was not alarmingly high during the measurement period, future studies should incorporate longer-term continuous PM 2.5 measurements along with other atmospheric chemical analyses to identify possible local air pollution sources in detail to ensure clean ambient air for the future in the Arctic. Our study provides quantitative evidence of the impact of open waste burning on air quality at a study site in Greenland, which could be crucial in developing air quality policies for this region in the Arctic.

aerosols↗

Standards development for modules in high temperature micro-environments

Photovoltaic (PV) module qualification standards, IEC 61215 and IEC 61730, were designed to apply to “general open-air climates” and IEC 61730 specifically indicated applicability of ambient air temperature of 40°C. Additionally, these standards provided allowances for so-called “open rack mounted PV modules” without a clear definition of “open-rack.” These implied restrictions and allowances meant that hotter climates or thermally restrictive installation methods may not be covered by these often customer-mandated certification standards. This is particularly salient for the significant growth regions of the Middle East and India that would be expected to operate at significantly higher temperatures. The applicability of these documents raised issues over the definition of “open rack” and the fact that the geographic location is just as important as the mounting configuration in assessing the impact of the micro-environment of a PV module. This work summarizes the scientific background for IEC Technical Specification 63126:2020 ED1, titled “Guidelines for qualifying PV modules components and materials for operation at high temperatures.” This standard was recently published by the IEC and is the first step in a systematic effort to rework these standards to address the question of temperature more directly. Instead of specifying a mounting condition, we specify different suites of tests suitable for a system (PV module, mounting style, and location) defined by the 98th percentile cell temperature. With a defined temperature regime to work from, this allowed us to use existing literature research combined with additional modeling work to determine, which tests would need to be modified. This resulted in suggested changes to material thermal indices, thermal cycling temperatures, hot spot testing, ultraviolet testing, and bypass diode testing among other tests and characteristics described in this study.

14 SOLAR ENERGY↗

A comprehensive review on regeneration strategies for direct air capture

Direct air capture (DAC), which removes CO 2 directly from ambient air, is a critical negative emission technology for mitigating global climate change. Efficiency and the source of energy are crucial considerations for DAC to enable negative emissions. Substantial technological progress has been made in DAC technologies, and promising opportunities exist for commercial-scale deployments. However, DAC technologies require high regeneration energy to release CO 2 from sorbents. Various approaches have been tested and optimized for different DAC systems. This review demonstrates that the work equivalent regeneration energy demand (supported by either the electric grid or fossil fuel combustion) ranges from 0.5–18.75 GJ/t-CO 2 for solid sorbent DAC systems and 0.62–17.28 GJ/t-CO 2 for liquid solvent DAC systems. The regeneration process is the energy-demanding process in DAC that is a key step for efficient operation. Potential methods to lower the regeneration energy demand include microwave, ultrasound, magnetic particle heating, and electric swing. Although the potential methods to date are still at the lab scale, significant work is being done to optimize DAC system processes.

54 ENVIRONMENTAL SCIENCES↗

Definition of air quality measurements for monitoring space shuttle launches

A description of a recommended air quality monitoring network to characterize the impact on ambient air quality in the Kennedy Space Center (KSC) (area) of space shuttle launch operations is given. Analysis of ground cloud processes and prevalent meteorological conditions indicates that transient HCl depositions can be a cause for concern. The system designed to monitor HCl employs an extensive network of inexpensive detectors combined with a central analysis device. An acid rain network is also recommended. A quantitative measure of projected minimal long-term impact involves the limited monitoring of NOx and particulates. All recommended monitoring is confined ti KSC property.

Thorpe, R. D.↗

Degradation Mechanism of Phosphate‐Based Li‐NASICON Conductors in Alkaline Environment

NASICON-type Li conductors (Li-NASICON) have traditionally been regarded as promising candidates for solid-state Li-air battery applications because of their stability in water and ambient air. However, the presence of water in the cathode of a Li-air battery can induce a highly alkaline environment by modifying the discharge product from Li 2 O 2 to LiOH which can potentially degrade cathode and separator materials. This study investigates the alkaline stability of common Li-NASICON chemistries through a systematic experimental study of LiTi x Ge 2-x (PO 4 ) 3 (LTGP) with varying x = 0–2.0. Density functional theory calculations are combined to gain a mechanistic understanding of the alkaline instability. It is demonstrated that the instability of LTGP in an alkaline environment is mainly driven by the dissolution of PO 4 3– groups, which subsequently precipitate as Li 3 PO 4 . The introduction of Ti facilitates the formation of a Ti-rich compound on the surface that eventually passivates the material, but only after significant bulk degradation. Consequently, phosphate-based Li-NASICON materials exhibit limited alkaline stability, raising concerns about their viability in humid Li-air batteries.

25 ENERGY STORAGE↗

Insights into the Oxidative Degradation Mechanism of Solid Amine Sorbents for CO 2 Capture from Air: Roles of Atmospheric Water

Abstract Direct air capture (DAC) processes for extraction of CO 2 from ambient air are unique among chemical processes in that they operate outdoors with minimal feed pretreatments. Here, the impact of humidity on the oxidative degradation of a prototypical solid supported amine sorbent, poly(ethylenimine) (PEI) supported on Al 2 O 3 , is explored in detail. By combining CO 2 adsorption measurements, oxidative degradation rates, elemental analyses, solid‐state NMR and in situ IR spectroscopic analysis in conjunction with 18 O labeling of water, a comprehensive picture of sorbent oxidation is achieved under accelerated conditions. We demonstrated that the presence of water vapor can play an important role in accelerating the degradation reactions. From the study we inferred the identity and kinetics of formation of the major oxidative products, and the role(s) of humidity. Our data are consistent with a radical mediated autooxidative degradation mechanism.

Carneiro, Juliana S. A.↗

Insights into the Oxidative Degradation Mechanism of Solid Amine Sorbents for CO 2 Capture from Air: Roles of Atmospheric Water

Direct air capture (DAC) processes for extraction of CO 2 from ambient air are unique among chemical processes in that they operate outdoors with minimal feed pretreatments. Here, the impact of humidity on the oxidative degradation of a prototypical solid supported amine sorbent, poly(ethylenimine) (PEI) supported on Al 2 O 3 , is explored in detail. By combining CO 2 adsorption measurements, oxidative degradation rates, elemental analyses, solid-state NMR and in situ IR spectroscopic analysis in conjunction with 18 O labeling of water, a comprehensive picture of sorbent oxidation is achieved under accelerated conditions. Here we demonstrated that the presence of water vapor can play an important role in accelerating the degradation reactions. From the study we inferred the identity and kinetics of formation of the major oxidative products, and the role(s) of humidity. Our data are consistent with a radical mediated autooxidative degradation mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical and experimental analysis of precooled desiccant system

This paper presents a numerical and experimental study of four novel, desiccant air-conditioning systems based on pre-cooling of the ambient air. The purpose of the study is to: 1) establish which configuration is most profitable for the future studies through numerical and experimental methods; 2) verify the concept of precooled system and confirm that it is working in experimental conditions (for this purpose two prototypes of evaporative cooling units were developed and compared for different operation arrangements with desiccant wheel); 3) Analyze practical aspects of the systems, which includes water consumption analysis, economic analysis and establishing operational modes during a cooling season in temperate climate conditions (the proposed solution has a significant advantage during operation in a temperate climate, since it can utilize its first evaporative cooler the only source of cooling energy when the humidity of outdoor air allows to to meet the latent cooling load). Four arrangements of the system with different dew point evaporative air cooler prototypes were selected and developed for comparative analysis. The system was simulated as a whole, also, each component was individually tested on measurement station. develop the optimal arrangement of the system through numerical and experimental analysis. Four different performance indicators were considered: thermal COP (Coefficient Of Performance), the ERR (Energy Efficiency Ratio), coefficient a describing the potential in compensating indoor cooling loads, water consumption ratio. Also costs of the systems were compared through economic analysis. It was established that arrangement which is characterized by best-averaged performance in terms of all considered factors is a unit combined with two different types of evaporative coolers (marked as System B)- this is caused by the favorable arrangement of two units, where one is better suited to the pre-cooler role, while the other is better suited as the post-cooler.

42 ENGINEERING↗

Evaluation of a New Approach for Entrainment and Detrainment Rate Estimation

Entrainment and detrainment rates (ε and δ) constitute the most critical free parameters in mass flux schemes commonly employed for cumulus parameterizations. Recently, Zhu et al. (2021) introduced a new approach that utilizes aircraft observations to simultaneously estimate ε and δ for cumulus clouds, overcoming the limitation of other observation-based approaches that solely yield ε without offering insights into δ. This study aims to comprehensively evaluate the reliability of this new approach. First, evaluation using an Explicit Mixing Parcel Model demonstrates the capability of the new approach to back-calculate predetermined ε and δ based on the physical properties before and after the entrainment mixing. Second, evaluation using large-eddy simulations illustrates that the new approach yields consistent ε and δ profiles compared to the traditional approach. Sensitivity tests indicate a weak sensitivity of the estimated δ with the new approach to the entrained air source. A decrease in the proportion of cloudy air in the assumed detrained air leads to a reduction in the estimated δ, while ε remains unaffected. Finally, the most appropriate assumptions for entrained and detrained air are discussed. Estimating ε for cumulus parameterizations involves acquiring ambient air more than 500 m away from the cloud edge as entrained air. Due to implicit mean field approximations in the traditional approach, determining the optimal assumption for detrained air properties proves challenging. Finally, this study confirms the reliability of the new approach in estimating ε and δ, providing confidence in its application to extensive observational data and advancement in parameterization.

54 ENVIRONMENTAL SCIENCES↗

Optical remote measurement of toxic gases

Enactment of the Clean Air Act Amendments (CAAA) of 1990 has resulted in increased ambient air monitoring needs for industry, some of which may be met efficiently using open-path optical remote sensing techniques. These techniques include Fourier transform spectroscopy, differential optical absorption spectroscopy, laser long-path absorption, differential absorption lidar, and gas cell correlation spectroscopy. With this regulatory impetus, it is an opportune time to consider applying these technologies to the remote and/or path-averaged measurement and monitoring of toxic gases covered by the CAAA. This article reviews the optical remote sensing technology and literature for that application.

Review↗

Mystery of Foil Air Bearings for Oil-free Turbomachinery Unlocked: Load Capacity Rule-of-thumb Allows Simple Estimation of Performance

The Oil-Free Turbomachinery team at the NASA Glenn Research Center has unlocked one of the mysteries surrounding foil air bearing performance. Foil air bearings are self-acting hydrodynamic bearings that use ambient air, or any fluid, as their lubricant. In operation, the motion of the shaft's surface drags fluid into the bearing by viscous action, creating a pressurized lubricant film. This lubricating film separates the stationary foil bearing surface from the moving shaft and supports load. Foil bearings have been around for decades and are widely employed in the air cycle machines used for cabin pressurization and cooling aboard commercial jetliners. The Oil-Free Turbomachinery team is fostering the maturation of this technology for integration into advanced Oil-Free aircraft engines. Elimination of the engine oil system can significantly reduce weight and cost and could enable revolutionary new engine designs. Foil bearings, however, have complex elastic support structures (spring packs) that make the prediction of bearing performance, such as load capacity, difficult if not impossible. Researchers at Glenn recently found a link between foil bearing design and load capacity performance. The results have led to a simple rule-of-thumb that relates a bearing's size, speed, and design to its load capacity. Early simple designs (Generation I) had simple elastic (spring) support elements, and performance was limited. More advanced bearings (Generation III) with elastic supports, in which the stiffness is varied locally to optimize gas film pressures, exhibit load capacities that are more than double those of the best previous designs. This is shown graphically in the figure. These more advanced bearings have enabled industry to introduce commercial Oil-Free gas-turbine-based electrical generators and are allowing the aeropropulsion industry to incorporate the technology into aircraft engines. The rule-of-thumb enables engine and bearing designers to easily size and select bearing technology for a new application and determine the level of complexity required in the bearings. This new understanding enables industry to assess the feasibility of new engine designs and provides critical guidance toward the future development of Oil-Free turbomachinery propulsion systems.

DellaCorte, Christopher↗

Research needs targeting direct air capture of carbon dioxide: Material & process performance characteristics under realistic environmental conditions

The extraction of CO 2 from ambient air, or direct air capture (DAC), is a crucial negative CO 2 emissions technology with great potential for contributing to the mitigation of global warming and climate change. Furthermore, nearly all published research on DAC has been conducted under indoor temperature conditions, i.e. 20 to 30 °C. In contrast, the future global implementation of DAC requires it to be operational across a wide expanse of geographical areas, of which the local temperatures can vary between -30 to 50 °C. Similarly, the absolute humidity can vary from ~0 to 84 g/m 3 in various locations. Due to the massive amount of air that would be processed, it may be impractical to preheat or dehumidify the air before the CO 2 separation. Therefore, it is important to develop DAC materials with good performance at realistic outdoor conditions, especially at sub-ambient conditions, i.e. -30 to 20 °C. In addition to material development, system-level studies at sub-ambient conditions are also needed for the DAC processes to reach optimal designs, which may be very different from those at ambient conditions. In this perspective article, we first assess the literature to identify the technical gaps that need to be filled for DAC to be applicable at realistic outdoor conditions. We then suggest additional research directions needed for DAC to be viable under varied conditions from the perspectives of materials and system designs. For materials, we discuss the expected physical and chemical property changes for the sorbents when the temperature or humidity reaches extremes within their range, and how that will impact performance. Similarly, for system design, we indicate how varied conditions will impact performance and how these changes will impact process optimization.

20 FOSSIL-FUELED POWER PLANTS↗

Investigation of Effectiveness of Air-Heating a Hollow Steel Propeller for Protection Against Icing. 3: 25% Partitioned Blades

The icing protection obtained from an internally air-heated propeller blade partitioned to confine the heated air forward of 25-percent chord was investigated in the NACA Cleveland icing research tunnel. A production-model hollow steel propeller was modified with an Internal radial partition at 25-percent chord and with shank and tip openings to admit and exhaust the heated air. Temperatures were measured on the blade surfaces and in the heated-air system during tunnel icing conditions. Heat-exchanger effectiveness and photographs of Ice formations on the blades were obtained. Surface temperature measurements indicated that confining the heated air forward of the 25-percent chord gave.a more economical distribution of the applied heat as compared with unpartitioned and 50-percent partitioned blades, by dissipating a greater percentage of the available heat at the leading edge. At a propeller speed of 850 rpm, a heating rate of 7000 Btu per hour per blade at a shank air temperature of 400 F provided adequate Icing protection at ambient-air temperatures of 23 F but not at temperatures as low as 15 F. With the heating rate used, a heat-exchanger effectiveness of 77 percent was obtained as compared to 56 percent for 50-percent partitioned and 47 percent for unpartitioned blades.

Mulholland, Donald R.↗

Buoyancy effects on smoldering combustion

The effect of buoyancy on the rate of spread of a concurrent smolder reaction through a porous combustible material is investigated theoretically and experimentally. In the experiments, buoyant forces are controlled by varying the density difference, and the smolder rate spread through porous alpha cellulose (0.83 void fraction) is measured as a function of the ambient air pressure. The smolder velocity is found to increase with the ambient pressure; extinction occurs when the buoyancy forces cannot overcome the drag forces, indicating that diffusion by itself cannot support the spread of a smolder reaction. Theoretical predictions are found to be in good qualitative agreement with the experimental results.

Dosanjh, S.↗