Search NASA⌕ Search

SEARCH · Search NASA

Results for “analyzed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Development of a 3-D energy-momentum analyzer for meV-scale energy electrons

In this article, we report on the development of a time-of-flight based electron energy analyzer capable of measuring the 3-D momentum and energy distributions of very low energy (millielectronvolt-scale) photoemitted electrons. This analyzer is capable for measuring energy and 3-D momentum distributions of electrons with energies down to 1 meV with a sub-millielectronvolt energy resolution. This analyzer is an ideal tool for studying photoemission processes very close to the photoemission threshold and also for studying the physics of photoemission based electron sources.

47 OTHER INSTRUMENTATION↗

Prediction of the performance of on-line ash analyzers used in the quality control process of a coal mining system

In this article, an analytical method for the prediction of dual energy transmission performance, based on uncertainty analysis, is proposed. Comparison of theoretically computed errors to those estimated during the trial operation of dual energy transmission analyzers installed in the lignite mines of Megalopolis and Ptolemais (Greece), shows that the developed analytical method for the prediction of dual energy transmission performance is not only accurate but also explanatory, aiding engineers and quality control personnel to realize the capabilities of the analyzer. Also, by taking into consideration the reduced quality variation of mined coal, as a result of the homogenization, which takes place during mining from several benches as well as during transportation, stacking, and reclaiming, the optimal installation position of the analyzer can be selected.

01 COAL, LIGNITE, AND PEAT↗

Analyzing power in elastic scattering of electrons off a spin-0 target

We consider the analyzing power on a spin-0 nuclear target. This observable is related to the imaginary part of the two-photon-exchange (box) diagram. We consider the contributions of elastic and inelastic intermediate states. The former requires knowledge of the elastic nuclear form factor, while the latter uses the optical theorem as input. The elastic contribution scales as the nuclear charge Z, while the inelastic contribution scales as the ratio of the atomic number and nuclear charge, A/Z. We provide estimates for {sup 4}He and {sup 208}Pb, in the kinematics of existing or upcoming experiments. In both cases, we predict negative values for the analyzing power of a few parts per million, and the dominant contribution is due to inelastic intermediate states. The analyzing power can contribute a substantial systematic error in parity-violating experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Vector and tensor analyzing powers in deuteron-proton breakup at 130 MeV

High-precision data for vector and tensor analyzing powers for the {sup 1}H(d-vector,pp)n reaction at a 130-MeV deuteron beam energy have been measured over a large part of the phase space. Theoretical predictions based on various approaches to describe the three nucleon (3N) system reproduce very well the vector analyzing power data and no three-nucleon force effect is observed for these observables. Tensor analyzing powers are also very well reproduced by calculations in almost the whole studied region, but locally certain discrepancies are observed. For A{sub xy} such discrepancies usually appear, or are enhanced, when model 3N forces, TM99 or Urbana, are included. Problems of all theoretical approaches with describing A{sub xx} and A{sub yy} are limited to very small kinematical regions, usually characterized by the lowest energy of the relative motion of the two protons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New developments in fabrication of high-energy-resolution analyzers for inelastic x-ray spectroscopy.

In this work new improvements related to the fabrication of spherical bent analyzers for 1 meV energy-resolution inelastic X-ray scattering spectroscopy are presented. The new method includes the use of a two-dimensional bender to achieve the required radius of curvature for X-ray analyzers. The advantage of this method is the ability to monitor the focus during bending, which leads to higher-efficiency analyzers.

43 PARTICLE ACCELERATORS↗

Montel mirror based collimating analyzer system for high-pressure resonant inelastic X-ray scattering experiments

Resonant inelastic X-ray scattering (RIXS) is increasingly playing a significant role in studying highly correlated systems, especially since it was proven capable of measuring low-energy magnetic excitations. However, despite high expectations for experimental evidence of novel magnetic phases at high pressure, unequivocal low-energy spectral signatures remain obscured by extrinsic scattering from material surrounding the sample in a diamond anvil cell (DAC): pressure media, Be gasket and the diamond anvils themselves. A scattered X-ray collimation based medium-energy resolution (~100 meV) analyzer system for a RIXS spectrometer at the Ir L 3 -absorption edge has been designed and built to remediate these difficulties. Due to the confocal nature of the analyzer system, the majority of extrinsic scattering is rejected, yielding a clean low-energy excitation spectrum of an iridate Sr 2 IrO 4 sample in a DAC cell. Finally, the energy resolution of different configurations of the collimating and analyzing optics are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantum Computing in the Cloud: Analyzing job and machine characteristics

As the popularity of quantum computing continues to grow, quantum machine access over the cloud is critical to both academic and industry researchers across the globe. And as cloud quantum computing demands increase exponentially, the analysis of resource consumption and execution characteristics are key to efficient management of jobs and resources at both the vendor-end as well as the client-end. While the analysis of resource consumption and management are popular in the classical HPC domain, it is severely lacking for more nascent technology like quantum computing. This paper is a first-of-its-kind academic study, analyzing various trends in job execution and resources consumption / utilization on quantum cloud systems. We focus on IBM Furthermore, quantum systems and analyze characteristics over a two year period, encompassing over 6000 jobs which contain over 600,000 quantum circuit executions and correspond to almost 10 billion “shots” or trials over 20+ quantum machines. Specifically, we analyze trends focused on, but not limited to, execution times on quantum machines, queuing/waiting times in the cloud, circuit compilation times, machine utilization, as well as the impact of job and machine characteristics on all of these trends. Furthermore, our analysis identifies several similarities and differences with classical HPC cloud systems. Based on our insights, we make recommendations and contributions to improve the management of resources and jobs on future quantum cloud systems.

42 ENGINEERING↗

WE-G-BRA-07: Analyzing the Safety Implications of a Brachytherapy Process Improvement Project Utilizing a Novel System-Theory-Based Hazard-Analysis Technique

Purpose: To investigate the hazards in cervical-cancer HDR brachytherapy using a novel hazard-analysis technique, System Theoretic Process Analysis (STPA). The applicability and benefit of STPA to the field of radiation oncology is demonstrated. Methods: We analyzed the tandem and ring HDR procedure through observations, discussions with physicists and physicians, and the use of a previously developed process map. Controllers and their respective control actions were identified and arranged into a hierarchical control model of the system, modeling the workflow from applicator insertion through initiating treatment delivery. We then used the STPA process to identify potentially unsafe control actions. Scenarios were then generated from the identified unsafe control actions and used to develop recommendations for system safety constraints. Results: 10 controllers were identified and included in the final model. From these controllers 32 potentially unsafe control actions were identified, leading to more than 120 potential accident scenarios, including both clinical errors (e.g., using outdated imaging studies for planning), and managerial-based incidents (e.g., unsafe equipment, budget, or staffing decisions). Constraints identified from those scenarios include common themes, such as the need for appropriate feedback to give the controllers an adequate mental model to maintain safe boundaries of operations. As an example, one finding was that the likelihood of the potential accident scenario of the applicator breaking during insertion might be reduced by establishing a feedback loop of equipment-usage metrics and equipment-failure reports to the management controller. Conclusion: The utility of STPA in analyzing system hazards in a clinical brachytherapy system was demonstrated. This technique, rooted in system theory, identified scenarios both technical/clinical and managerial in nature. These results suggest that STPA can be successfully used to analyze safety in brachytherapy and may prove to be an alternative to other hazard analysis techniques.

60 APPLIED LIFE SCIENCES↗

Analyzed DTS Data, Guelph, ON Canada

Analyzed DTS datasets from active heat injection experiments in Guelph, ON Canada is included. A .pdf file of images including borehole temperature distributions, temperature difference distributions, temperature profiles, and flow interpretations is included as the primary analyzed dataset. Analyzed data used to create the .pdf images are included as a matlab data file that contains the following 5 types of data: 1) Borehole Temperature (matrix of temperature data collected in the borehole), 2) Borehole Temperature Difference (matrix of temperature difference above ambient for each test), 3) Borehole Time (time in both min and sec since the start of a DTS test), 4) Borehole Depth (channel depth locations for the DTS measurements), 5) Temperature Profiles (ambient, active, active off early time, active off late time, and injection).

15 GEOTHERMAL ENERGY↗

Sulfur Dioxide Analyzer Instrument Handbook

The Sulfur Dioxide Analyzer measures sulfur dioxide based on absorbance of UV light at one wavelength by SO 2 molecules which then decay to a lower energy state by emitting UV light at a longer wavelength. Specifically, SO 2 + hυ1 →SO 2 *→SO 2 + hυ2 The emitted light is proportional to the concentration of SO 2 in the optical cell. External communication with the analyzer is available through an Ethernet port configured through the instrument network of the AOS systems. The Model 43i-TLE is part of the i-series of Thermo Scientific instruments. The i-series instruments are designed to interface with external computers through the proprietary Thermo Scientific iPort Software. However, this software is somewhat cumbersome and inflexible. Brookhaven National Laboratory (BNL) has written an interface program in National Instruments LabView that both controls the Model 43i-TLE Analyzer AND queries the unit for all measurement and housekeeping data. The LabView vi (the software program written by BNL) ingests all raw data from the instrument and outputs raw data files in a uniform data format similar to other instruments in the AOS and described more fully in Section 6.0 below.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of an IXS imaging analyzer with an extended scattering source

A concept of an inelastic x-ray scattering (IXS) spectrograph with an imaging analyzer was proposed recently and discussed in a number of publications (see e.g. Ref.1). The imaging analyzer as proposed combines x-ray lenses with highly dispersive crystal optics. It allows conversion of the x-ray energy spectrum into a spatial image with very high energy resolution. However, the presented theoretical analysis of the spectrograph did not take into account details of the scattered radiation source, i.e. sample, and its impact on the spectrograph performance. Using numerical simulations we investigated the influence of the finite sample thickness, the scattering angle and the incident energy detuning on the analyzer image and the ultimate resolution.

47 OTHER INSTRUMENTATION↗

Corrections to the elastic p ↑ p ↑ analyzing power parameterization at high energies

The HJET polarimeter was designed to measure the absolute polarization of the proton beams at RHIC. It can also be used for the precise measurement of the elastic pp single and double spin analyzing powers. Recently Boris Kopeliovich pointed out that analyzing power parametrization,which is conventionally used for these measurements, was derived with specific simplifications and for the experimental accuracy achieved at HJET, the corrections should be applied. In this not ewe evaluate the corrections to analyzing powers due to (i) the differences between electromagnetic and hadronic form factors, and (ii) the ~$m$ $^{2}_{p}$/s term in elastic pp electromagnetic amplitude. The corresponding variations of the measured hadronic spin-flip amplitudes are about experimental uncertainties of the HJET measurements. It should also be noted that the evaluated corrections might be essential for the elastic pp forward real-to-imaginary amplitude ratios ρ listed in PDG.

43 PARTICLE ACCELERATORS↗

ASTM D03 Workshop: Developing a Hydrogen Contamination Detector Analyzer [Slides]

Non-hydrogen constituents in the fuel steam can cause irreversible damage to FC systems and therefore should be avoided. The objectives are: 1. Develop a low-cost fast response device (analyzer) to measure impurities in a dry hydrogen fuel stream at or above the SAE J2719 levels, 2. Develop understanding of a working mechanism and improve the analyzer by identifying the best materials and their configuration, and 3. Test the analyzer in real-world environments.

42 ENGINEERING↗

Multiplexing Focusing Analyzer for Efficient Stress-Strain Measurements

Statement of the problem or situation that is being addressed. Although thermal and cold neutron scattering is widely used and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed. We propose to design and demonstrate novel diffractive optical device, which will enable very efficient residual stress neutron diffractometers. The proposed device will be a multi-foil analyzer, where each foil is constructed of focusing bent single crystals of Si. Such device will enable polychromatic residual stress neutron diffraction. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast measurements for determining residual stress tensors, raster large samples or screen multiple samples. Commercial Applications and Other Benefits The outcome of this project would be the demonstration of commercial devices, novel neutron optical components, which could be utilized to improve the performance of existing instruments or build novel neutron scattering instruments at DOE neutron facilities and commercial laboratory neutron sources. These new devices will widen the scope of research conducted using neutrons and enable measurements not feasible at present. Summary for Members of Congress Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analyzing Mass Spectrometry Imaging Data of 13C-Labeled Phospholipids in Camelina sativa and Thlaspi arvense (Pennycress) Embryos

The combination of 13C-isotopic labeling and mass spectrometry imaging (MSI) offers an approach to analyze metabolic flux in situ. However, combining isotopic labeling and MSI presents technical challenges ranging from sample preparation, label incorporation, data collection, and analysis. Isotopic labeling and MSI individually create large, complex data sets, and this is compounded when both methods are combined. Therefore, analyzing isotopically labeled MSI data requires streamlined procedures to support biologically meaningful interpretations. Using currently available software and techniques, here we describe a workflow to analyze 13C-labeled isotopologues of the membrane lipid and storage oil lipid intermediate―phosphatidylcholine (PC). Our results with embryos of the oilseed crops, Camelina sativa and Thlaspi arvense (pennycress), demonstrated greater 13C-isotopic labeling in the cotyledons of developing embryos compared with the embryonic axis. Greater isotopic enrichment in PC molecular species with more saturated and longer chain fatty acids suggest different flux patterns related to fatty acid desaturation and elongation pathways. The ability to evaluate MSI data of isotopically labeled plant embryos will facilitate the potential to investigate spatial aspects of metabolic flux in situ.

metabolomics↗

Harmonic distortion analyzer speeds setup of magnetic tape recorders

Harmonic distortion analyzer effects rapid and accurate setup and calibration of magnetic tape instrumentation recorders. The analyzer is portable, requires no warmup period and need not be calibrated for normal usage. Average setup time with this analyzer is approximately 30 seconds per track.

Tinari, D. F.↗

Pseudotachometer for mobile metabolic analyzer

Metabolic analyzer determines a patient's walking or ambulation speed and simultaneously measures his metabolic parameters. Analyzer is designed to move at some preselected human ambulation speed. During test, patient is connected to system and follows analyzer closely while his metabolic data is being monitored.

Currie, J. R.↗

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.↗