Search NASA⌕ Search

SEARCH · Search NASA

Results for “anemometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Anemometer calibrator

Calibrator generates accurate flow velocities over wide range of gas pressure, temperature, and composition. Both pressure and flow velocity can be maintained within 0.25 percent. Instrument is essentially closed loop hydraulic system containing positive displacement drive.

Bate, T.↗

Ion-tracer anemometer

Gas velocity measuring instrument measures transport time of ion-trace traveling fixed distance between ionization probe and detector probe. Electric field superimposes drift velocity onto flow velocity so travel times can be reduced to minimize ion diffusion effects.

Bass, R. L.↗

Maxometers (peak wind speed anemometers)

An instrument for measuring peak wind speeds under severe environmental conditions is described, comprising an elongated cylinder housed in an outer casing. The cylinder contains a piston attached to a longitudinally movable guided rod having a pressure disk mounted on one projecting end. Wind pressure against the pressure disk depresses the movable rod. When the wind reaches its maximum speed, the rod is locked by a ball clutch mechanism in the position of maximum inward movement. Thereafter maximum wind speed or pressure readings may be taken from calibrated indexing means.

Kaufman, J. W.↗

Toward proof of satellite anemometer concept

The S-193 oceanographic program is designed to demonstrate the operational feasibility of measuring ocean surface winds on a global basis with a composite radar-radiometer sensor. Near-simultaneous radiometric/scatterometric measurements offer a better opportunity to make improved estimates of surface winds through a variety of atmospheric conditions. Support is presented in developing interpretational techniques for the joint measurements, designing experiments to verify the joint interpretation techniques, predicting the observations from theory, evaluating system effects on the measurements, and developing system design criteria.

Classen, J.↗

Low-power anemometer

Device allows wind speeds to be measured with less power by alternating hot-wire or hot-film heating periods with measurement periods. System includes reference auxiliary circuits to generate V sub ref and ramp voltage (E sub 3) and reference half of bridge circuit. Circuit permits use of several sensing films with common temperature compensation sensor.

Gilje, R. I.↗

Laser anemometer measurements at the exit of a T63 combustor

In the first practical application of laser anemometry to an actual gas turbine engine combustor, the mean velocity and turbulent intensity profiles were measured in a steady-flow combustion rig across an annulus simulating a turbine inlet; to establish a basis for comparison with similar measurements to be made in an operating engine and to confirm current turbine aerodynamics and heat transfer design assumptions. It was necessary to develop a new experimental technique for traversing the annulus due to differential thermal expansion of the cantilevered combustion rig and a new computer-graphics analysis technique for analyzing the velocity histograms due to the high background light intensity. The axial mean velocity and turbulent intensity were uniform across the annulus under all operating conditions and the flow had little or no swirl component. The isothermal mean velocity was doubled by the burning of fuel, however, the isothermal turbulent intensity was relatively unaffected.

Zimmerman, D. R.↗

A calibration technique for a hot-wire-probe vector anemometer

Calibration tests using hot wires were conducted using a newly developed test rig that greatly reduced the data acquisition time. A comparison of measured and computed velocity vector magnitude and direction indicates the necessity of complete probe calibration to determine flow interference and/or operating limitation regions. Calibration results indicate that flow rates with 3 percent accuracy and flow angles with 5 deg accuracy are attainable.

Scheiman, J.↗

Laser anemometer measurements in an annular cascade of core turbine vanes and comparison with theory

Laser measurements were made in an annular cascade of stator vanes operating at an exit critical velocity ratio of 0.78. Velocity and flow angles in the blade to blade plane were obtained at every 10 percent of axial chord within the passage and at 1/2 axial chord downstream of the vanes for radial positions near the hub, mean and tip. Results are presented in both plot and tabulated form and are compared with calculations from an inviscid, quasi three dimensional computer program. The experimental measurements generally agreed well with these theoretical calculations, an indication of the usefulness of this analytic approach.

Goldman, L. J.↗

Comparison of laser anemometer measurements and theory in an annular turbine cascade with experimental accuracy determined by parameter estimation

Experimental measurements of the velocity components in the blade to blade (axial tangential) plane were obtained with an axial flow turbine stator passage and were compared with calculations from three turbomachinery computer programs. The theoretical results were calculated from a quasi three dimensional inviscid code, a three dimensional inviscid code, and a three dimensional viscous code. Parameter estimation techniques and a particle dynamics calculation were used to assess the accuracy of the laser measurements, which allow a rational basis for comparison of the experimenal and theoretical results. The general agreement of the experimental data with the results from the two inviscid computer codes indicates the usefulness of these calculation procedures for turbomachinery blading. The comparison with the viscous code, while generally reasonable, was not as good as for the inviscid codes.

Goldman, L. J.↗

Potential errors in using one anemometer to characterize the wind power over an entire rotor disk

Wind data collected at four levels on a 90-m tower in a prospective wind farm area are used to evaluate how well the 10-m wind speed data with and without intermittent vertical profile measurements compare with the 90-m tower data. If a standard, or even predictable, wind speed profile existed, there would be no need for a large, expensive tower. This cost differential becomes even more significant if several towers are needed to study a prospective wind farm.

Simon, R. L.↗

The wedge hot-film anemometer in supersonic flow

A commercial wedge hot-film probe is studied to determine its heat transfer response in transonic to low supersonic flows of high unit Reynolds number. The results of this study show that its response in this flow regime differs from the response of cylindrical type sensors. Whereas the cylindrical sensor has the same sensitivity to velocity as to density for free-stream Mach numbers exceeding 1.3, the wedge probe sensitivity to velocity is always greater than its sensitivity to density over the entire flow regime. This property requires determination of three fluctuation components due to density, velocity, and temperature, in a transonic or supersonic turbulent flow. Sensitivity equations are derived based on the observed behavior of the wedge probe. Both the durability and the frequency response of the probe are excellent, the square wave insertion test indicating frequency response near 130 kHz. The directional response of the probe at sonic speed is poor and requires further examination before Reynolds stress measurements are attempted with dual sensor probes.

Seiner, J. M.↗

Constant-temperature hot-wire anemometer practice in supersonic flows. I - The normal wire

The performance of a constant-temperature normal hot-wire in a supersonic flow is critically examined. It is shown that this instrument is inherently unsuitable for measuring turbulent temperature correlations because of the highly nonlinear response to temperature fluctuations, particularly at low overheat ratios. The instrument is therefore limited to measurements of mean and fluctuating mass-flow rates. Suitable calibration procedures, as well as the limits on spatial and temporal resolution are discussed, and corrections for mean stagnation temperature changes are suggested.

Smits, A. J.↗

Constant-temperature hot-wire anemometer practice in supersonic flows. II - The inclined wire

The performance of a constant-temperature inclined hot-wire in a supersonic flow is critically examined. It is shown that calibration techniques applicable to subsonic flow, such as the cosine cooling law cannot be used when the flow is supersonic. Calibration and measurement procedures appropriate to supersonic flow are suggested, together with the possible limits on their validity. Experimental results for different wires indicate that the sensitivities do not seem to depend on flow direction according to any simple correlation. When the sensitivity exhibits a strong dependence on flow direction, the wire should be discarded to avoid errors due to nonlinear effects.

Smits, A. J.↗