Search NASA⌕ Search

SEARCH · Search NASA

Results for “automatic calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

On The Processing of Log Files for Monitoring Antenna Health

In order to improve the quality of geodetic results, we have developed an infrastructure for timely processing of telemetry from IVS observing stations. We check every hour for new log files with telemetry from both VLBI observing sessions, single dish experiments, and stow-in data collection and automatically process them. The telemetry data we use is the system temperature, phase calibration phases and amplitudes, system equivalent flux density, and the differences between formatter clock and GPS clock. For the system temperature and phase calibration, processing includes filtering out outliers and computing averages and rms of the scatter in each scan. Furthermore, for the phase calibration we also compute the group delay and detect spurious signals. Cleaned and post-processed telemetry is archived. Our process detects abnormalities, such as, anomalously high system temperature, unstable phase calibration phases, jumps in the GPS and formatter clock differences, and others. With our procedure, the latency of detection of station abnormalities is reduced to less than two hours. Early detection of abnormalities reduces the amount of affected data since station personnel get early alerts. We discuss our experience of running this system since 2022.

VLBI↗

Magnitude calibration of a fixed head star tracker using Astro-1 flight data

The Astro-1 UV astronomy mission was hampered by the failures of the automatic star acquisition procedure. The acquisition procedure depended on the Instrument Pointing Subsystem's Fixed Head Star Trackers (FHST) to acquire, track and identify guidestars of known visual magnitude. During the Astro-1 mission it was suspected that the star magnitudes measured by the FHST were much lower than predicted. A postflight investigation of the Astro-1 flight data confirmed and quantified this suspicion. Star magnitude calibration curves computed from the flight data depict the variance from the preflight calibration curves. These results are helping engineers to plan improvements to the acquisition procedure for the upcoming Astro-2 mission.

Rakoczy, John M.↗

Rapid and precise measurement of flatband voltage

The paper outlines the design, principles of operation, and calibration of a five-IC network intended to give a rapid, precise, and automatic determination of the flatband voltage of MOS capacitors. The basic principle of measurement is to compare the analog output voltage of a capacitance meter - which is directly proportional to the capacitance being measured - with a preset or dialed-in voltage proportional to the calculated flatband capacitance by means of a comparator circuit. The bias to the MOS capacitor supplied through the capacitance meter is provided by a ramp voltage going from a negative toward a positive voltage level and vice versa. The network employs two monostable multivibrators for reading and recording the flatband voltage and for resetting the initial conditions and restarting the ramp. The flatband voltage can be held and read on a digital voltmeter.

Li, S. P.↗

Systems Analyze Water Quality in Real Time

A water analyzer developed under Small Business Innovation Research (SBIR) contracts with Kennedy Space Center now monitors treatment processes at water and wastewater facilities around the world. Originally designed to provide real-time detection of nutrient levels in hydroponic solutions for growing plants in space, the ChemScan analyzer, produced by ASA Analytics Inc., of Waukesha, Wisconsin, utilizes spectrometry and chemometric algorithms to automatically analyze multiple parameters in the water treatment process with little need for maintenance, calibration, or operator intervention. The company has experienced a compound annual growth rate of 40 percent over its 15-year history as a direct result of the technology's success.

Source record↗

TESS Data Release Notes:Reprocessing of Sectors 14–19, DR30 & DR33

TESS data release 30 (DR30) provides reprocessed data products of Sector 14 to 19. The updated data products were generated using version 4.0 of the science processing pipeline and conform to the final set of data anomaly flags defined over the last two years of TESS data analysis and pipeline development. Data release 33 (DR33) corresponds to a multisector search for transiting planets in the same reprocessed data. A detailed description of the changes in the data products in DR30 and DR33 is discussed in§2, and a brief list of changes is summarized here: The timestamps for 2 minute cadence and FFI data are more accurate. The differences between reprocessed data and previous data releases are less than 2.0 seconds in all cases. Photometric apertures were increased in size for targets with T mag<11. Three new Data Anomaly Flags were added to mitigate the effects of scattered light:–Cadences with strong scattered light signals or saturation effects that corrupt the calibration data are flagged and removed from analysis (bit 15, value 16384, “Bad Calibration Exclude”).–Scattered light data anomaly flags are customized for each target, and flagged automatically based on the local background level (bit 13, value 4096, ”Scattered light flag”).–Cadences with insufficient targets to derive cotrending basis vectors are flagged and the PDCSAP FLUX light curves are set to NULL at these times (bit 16, value 32768, “Insufficient Targets for Error Correction Exclude”). The planet search of the reprocessed light curves produced a different set of TCEs from the original processed data. Although there is a high degree of overlap between the original and reprocessed data (∼83% of targets produced TCEs in common), new TCEs were produced in DR30 and not every TCE from previous data releases was recovered. The same is true of the multisector search results from DR33 compared to DR28

TESS'↗

Advanced Signal Conditioners for Data-Acquisition Systems

Signal conditioners embodying advanced concepts in analog and digital electronic circuitry and software have been developed for use in data-acquisition systems that are required to be compact and lightweight, to utilize electric energy efficiently, and to operate with high reliability, high accuracy, and high power efficiency, without intervention by human technicians. These signal conditioners were originally intended for use aboard spacecraft. There are also numerous potential terrestrial uses - especially in the fields of aeronautics and medicine, wherein it is necessary to monitor critical functions. Going beyond the usual analog and digital signal-processing functions of prior signal conditioners, the new signal conditioner performs the following additional functions: It continuously diagnoses its own electronic circuitry, so that it can detect failures and repair itself (as described below) within seconds. It continuously calibrates itself on the basis of a highly accurate and stable voltage reference, so that it can continue to generate accurate measurement data, even under extreme environmental conditions. It repairs itself in the sense that it contains a micro-controller that reroutes signals among redundant components as needed to maintain the ability to perform accurate and stable measurements. It detects deterioration of components, predicts future failures, and/or detects imminent failures by means of a real-time analysis in which, among other things, data on its present state are continuously compared with locally stored historical data. It minimizes unnecessary consumption of electric energy. The design architecture divides the signal conditioner into three main sections: an analog signal section, a digital module, and a power-management section. The design of the analog signal section does not follow the traditional approach of ensuring reliability through total redundancy of hardware: Instead, following an approach called spare parts tool box, the reliability of each component is assessed in terms of such considerations as risks of damage, mean times between failures, and the effects of certain failures on the performance of the signal conditioner as a whole system. Then, fewer or more spares are assigned for each affected component, pursuant to the results of this analysis, in order to obtain the required degree of reliability of the signal conditioner as a whole system. The digital module comprises one or more processors and field-programmable gate arrays, the number of each depending on the results of the aforementioned analysis. The digital module provides redundant control, monitoring, and processing of several analog signals. It is designed to minimize unnecessary consumption of electric energy, including, when possible, going into a low-power "sleep" mode that is implemented in firmware. The digital module communicates with external equipment via a personal-computer serial port. The digital module monitors the "health" of the rest of the signal conditioner by processing defined measurements and/or trends. It automatically makes adjustments to respond to channel failures, compensate for effects of temperature, and maintain calibration.

Lucena, Angel↗

Fast calibration of gas flowmeters

Digital unit automates calibration sequence using calculator IC and programmable read-only memory to solve calibration equations. Infrared sensors start and stop calibration sequence. Instrument calibrates mass flowmeters or rotameters where flow measurement is based on mass or volume. This automatic control reduces operator time by 80 percent. Solid-state components are very reliable, and digital character allows system accuracy to be determined primarily by accuracy of transducers.

Lisle, R. V.↗

Automatic analysis of stereoscopic GOES/GOES and GOES/NOAA image pairs for measurement of hurricane cloud top height and structure

Results are presented from a baseline study using an synthetic stereo image pair to test the Automatic Stereo Analysis (ASA) technique for reproducing cloud top structure. The ASA analysis, display, and calibration procedures are described. A GEO/LEO (GOES/NOAA AVHRR) image pair from Hurrican Allen in 1980 is used to illustrate the results that can be obtained using the ASA technique. Also, results are presented from applying the ASA technique to a GEO/GEO (GOES/GOES) image pair of Hurricane Gilbert in 1988.

Hasler, A. F.↗

Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

Meneghelli, Barry↗

Automatic Control Of Length Of Welding Arc

Nonlinear relationships among current, voltage, and length stored in electronic memory. Conceptual microprocessor-based control subsystem maintains constant length of welding arc in gas/tungsten arc-welding system, even when welding current varied. Uses feedback of current and voltage from welding arc. Directs motor to set position of torch according to previously measured relationships among current, voltage, and length of arc. Signal paths marked "calibration" or "welding" used during those processes only. Other signal paths used during both processes. Control subsystem added to existing manual or automatic welding system equipped with automatic voltage control.

Iceland, William F.↗

The least squares process of MEDIA for computing DRVID calibration polynomials

A process is described and evaluated for computing a least squares polynomial approximation of data points in which the optimum degree of the polynomial is automatically determined. An iterative smoothing technique is used to replace every point with the value taken on by a moving least squares polynomial computed from a subset of points centered at the point to be replaced. The optimum degree of the resulting polynomial approximation is determined by analyzing the finite differences of each successive set of smoothed points. To evaluate the process, both artificially constructed data and actual Mariner Mars 1971 (MM'71) tracking data are used. This process was incorporated into a transmission media calibration computer program (MEDIA), which calibrates radiometric data to overcome the effects on the tracking signal of charged particle media. MEDIA was used in support of MM'71.

Leavitt, R. K.↗

Instrumentation for measuring aircraft noise and sonic boom

Improved instrumentation suitable for measuring aircraft noise and sonic booms is described. An electric current proportional to the sound pressure level at a condenser microphone is produced and transmitted over a cable and amplified by a zero drive amplifier. The converter consists of a local oscillator, a dual-gate field-effect transistor mixer, and a voltage regulator/impedance translator. The improvements include automatic tuning compensation against changes in static microphone capacitance and means for providing a remote electrical calibration capability.

Zuckerwar, A. J.↗

Carbon monoxide measurement in the global atmospheric sampling program

The carbon monoxide measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available infrared absorption analyzer. The modifications increased the sensitivity of the analyzer to 1 ppmv full scale, with a limit of detectability of 0.02 ppmv. Packaging was modified for automatic, unattended operation in an aircraft environment. The GASP system is described along with analyzer operation, calibration procedures, and measurement errors. Uncertainty of the CO measurement over a 2-year period ranged from + or - 3 to + or - 13 percent of reading, plus an error due to random fluctuation of the output signal + or - 3 to + or - 15 ppbv.

Dudzinski, T. J.↗

System Measures Loads In Bolts

Improved technique for ultrasonic nondestructive measurement of loads in bolts involves use of pulsed phase-locked loop interferometer. Provides for correction of errors and for automatic readout of loads in bolts. Actual bolt load measured, using transducers rebonded after bolts tightened. Calibration block and thermometer added. Technique applicable to critical fasteners in aerospace applications, nuclear reactors, petroleum and other chemical processing plants, steel bridges, and other structures.

Allison, Sidney G.↗

High Resolution X-Ray Micro-CT of Ultra-Thin Wall Space Components

A high resolution micro-CT system has been assembled and is being used to provide optimal characterization for ultra-thin wall space components. The Glenn Research Center NDE Sciences Team, using this CT system, has assumed the role of inspection vendor for the Advanced Stirling Convertor (ASC) project at NASA. This article will discuss many aspects of the development of the CT scanning for this type of component, including CT system overview; inspection requirements; process development, software utilized and developed to visualize, process, and analyze results; calibration sample development; results on actual samples; correlation with optical/SEM characterization; CT modeling; and development of automatic flaw recognition software. Keywords: Nondestructive Evaluation, NDE, Computed Tomography, Imaging, X-ray, Metallic Components, Thin Wall Inspection

Roth, Don J.↗

Development of a drift-correction procedure for a photoelectric spectrometer

A technique has been developed to automatically correct for drifts in the radiometric sensitivity of the detector channels in a direct-reading emission spectrometer. The method utilizes a 1000 W tungsten-halogen reference lamp to illuminate the detectors through the same optical path as that traversed during the analysis of the sample. Detector channel responses to the light are compared to those for the same light intensity at the time of analytical calibration. This corrects for the drift. It is noted that with the exception of positioning the lamp, the procedure is fully automatic.

Chapman, G. B., II↗

Preliminary flight-determined subsonic lift and drag characteristics of the X-29A forward-swept-wing airplane

The X-29A subsonic lift and drag characteristics determined, met, or exceeded predictions, particularly with respect to the drag polar shapes. Induced drag levels were as great as 20 percent less than wind tunnel estimates, particularly at coefficients of lift above 0.8. Drag polar shape comparisons with other modern fighter aircraft showed the X-29A to have a better overall aircraft aerodynamic Oswald efficiency factor for the same aspect ratio. Two significant problems arose in the data reduction and analysis process. These included uncertainties in angle of attack upwash calibration and effects of maneuver dynamics on drag levels. The latter problem resulted from significantly improper control surface automatic camber control scheduling. Supersonic drag polar results were not obtained during this phase because of a lack of engine instrumentation to measure afterburner fuel flow.

Hicks, John W.↗

Earth Science Data Archive and Access at the NASA/Goddard Space Flight Center Distributed Active Archive Center (DAAC)

The Goddard Distributed Active Archive Center (DAAC), as an integral part of the Earth Observing System Data and Information System (EOSDIS), is the official source of data for several important earth remote sensing missions. These include the Sea-viewing Wide-Field-of-view Sensor (SeaWiFS) launched in August 1997, the Tropical Rainfall Measuring Mission (TRMM) launched in November 1997, and the Moderate Resolution Imaging Spectroradiometer (MODIS) scheduled for launch in mid 1999 as part of the EOS AM-1 instrumentation package. The data generated from these missions supports a host of users in the hydrological, land biosphere and oceanographic research and applications communities. The volume and nature of the data present unique challenges to an Earth science data archive and distribution system such as the DAAC. The DAAC system receives, archives and distributes a large number of standard data products on a daily basis, including data files that have been reprocessed with updated calibration data or improved analytical algorithms. A World Wide Web interface is provided allowing interactive data selection and automatic data subscriptions as distribution options. The DAAC also creates customized and value-added data products, which allow additional user flexibility and reduced data volume. Another significant part of our overall mission is to provide ancillary data support services and archive support for worldwide field campaigns designed to validate the results from the various satellite-derived measurements. In addition to direct data services, accompanying documentation, WWW links to related resources, support for EOSDIS data formats, and informed response to inquiries are routinely provided to users. The current GDAAC WWW search and order system is being restructured to provide users with a simplified, hierarchical access to data. Data Browsers have been developed for several data sets to aid users in ordering data. These Browsers allow users to specify spatial, temporal, and other parameter criteria in searching for and previewing data.

Leptoukh, Gregory↗