Search NASA⌕ Search

SEARCH · Search NASA

Results for “bans or moratoriums”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Comparison of Environmentally Friendly Space Compatible Grease to its Predecessor in a Space Mechanism Bearing Test Rig

Perfluoroakylpolyether (PFPE) greases are used extensively in critical flight hardware in a space environment. In the past, these greases have been processed using chlorofluorocarbon (CFC) based solvents. In response to the recent ban of CFC's, new formulations of environmentally friendly PFPE greases that are not processed with CFC based solvents were developed. The purpose of this study was to compare the performance of a new environmentally friendly formulation PFPE grease to a previously proven space compatible formulation PFPE grease. A one year test using 20 small electrical motors (two bearings per motor) was conducted in a high vacuum environment(2.0 x 10(exp 4)) Torr at a temperature of 90 C. Twenty bearings were lubricated with a new environmentally friendly formulation, and twenty bearings were lubricated with an old formulation. The mass of each lubricated bearing was measured both pre and post test. Along with mass loss measurements a profilometer trace was taken to measure post test wear of the bearings. In addition the bearings were visually examined and analyzed using an optical microscope.

T R Jett↗

A Study of Flame Propagation on Water-Mist Laden Gas Mixtures in Microgravity

The use of water mists (very fine water sprays) for fire suppression is currently receiving increased attention as a replacement technology for halogen-based chemical agents-such as Halon 1301 (CF3Br)--the manufacturing of which has been banned by the Montreal Protocol due to their high ozone depletion potential. Water mist technology has been found effective for a wide range of applications such as Class B pool fires, shipboard machinery, aircraft cabins, computers, and electronic equipment. There are five distinct mechanisms by which water droplets may interact with a flame. First, the high enthalpy of vaporization of water (2450 kJ/kg) leads to heat removal from the flame front as the liquid droplets turn to steam. Second, as water vaporizes its volume increases approximately three orders of magnitude, which leads to the dilution of the oxygen and vaporized fuel required to maintain the flame. The third effect is the recombination of H-atoms and other radicals on the droplet surface. A fourth effect of water mists in fires is the retardation of surface propagation rates due to the wetting of walls and surfaces. The last potential impact of fine water mists affects the radiative propagation of the fire by forming an optically thick barrier to infrared radiation which prevents ignition of the unburned regions. Unfortunately, little fundamental information exists on the interaction of a flame with a water mist. To date, there is no widely accepted interpretation of the critical concentration of droplets required to suppress a flame or of the fundamental mechanisms involved in flame extinguishment by water mists. One of the main obstacles to obtaining such understanding is the difficulty of providing a simple, well-defined experimental setup for the flame front/water mist interaction. Some of the difficulty stems from the problem of generating, distributing and maintaining a homogeneous concentration of droplets throughout a chamber while gravity depletes the concentration and alters the droplet size by coalescence and agglomeration mechanisms. Experiments conducted in the absence of gravity provide an ideal environment to study the interaction of water mists and flames by eliminating these distorting effects. In addition, microgravity eliminates the complex flow patterns induced between the flame front and the water droplets. The long duration and quality of microgravity in space flights provide the required conditions to perform the setup and monitoring of flame suppression experiments. Consequently, a series of experiments have been identified to be performed on the Combustion Module (CM-2) in the Space Shuttle. These consist of measuring the extinguishing capability of a water mist on a premixed flame propagating along a tube. These experiments should provide the necessary data to obtain further understanding of the water mist suppression phenomena that can be later used to design and manufacture appropriate fire suppression systems. In preparation for the orbital flights, experiments have been conducted on low-gravity ground facilities to obtain the preliminary data necessary to define the scientific objectives and technical issues of the spacecraft experiments.

Abbud-Madrid, A.↗

Effect of Bearing Cleaning on Long Term Bearing Life

For many years chlorofluorocarbon (CFC) based solvents, such as CFC-113 and 1,1,1, trichloroethane (TCA), were used as bearing cleaning solvents for space mechanism bearings. The 1995 ban on the production of ozone depleting chemicals (ODC) such as CFCs caused a change requiring the use of ODC-free cleaners for precision bearing cleaning. With this change the question arises; what effect if any do these new cleaners have on long term bearing life? The purpose of this study was to evaluate this effect. A one year test using 60 small electrical motors (two bearings per motor) was conducted in a high vacuum environment (2.0 x 10(exp -6) torr) at a temperature of 90 C. Prior to testing the bearings were cleaned with one of four cleaners. These cleaners included two aqueous based cleaners, a CFC based cleaner and supercritical carbon dioxide. Three space compatible greases were tested. After testing, the mass of each lubricated bearing was measured both pre and post test. Along with mass loss measurements a profilometer trace of each bearing was taken to measure post test wear of the bearings. In addition, the bearings were visually examined and analyzed using an optical microscope.

Jett, Tim↗

Effect of Bearing Cleaning on Long Term Bearing Life

For many years chlorofluorocarbon (CFC ) based solvents, such as Freon and 1,1,1, Trichloroethane (TCA), were used as bearing cleaning solvents for space mechanisms. The 1995 ban on the production of ozone depleting chemicals (ODC) such as CFCs caused a change to new ODC-free cleaners for the precision bearing cleaning. With this change the question arises what effect if any do these new cleaners have on long term bearing life. The purpose of this study was to evaluate this effect. A one year test using 60 small electrical motors (two bearings per motor) was conducted in a high vacuum environment (2.0* 10(exp -6) torr) at a temperature of 90C. Prior to testing the bearings were cleaned with one of four cleaners. These cleaners included two aqueous based cleaners, a CFC based cleaner and supercritical carbon dioxide. Three space compatible greases were tested. After testing the mass of each lubricated bearing was measured both pre and post test. Along with mass loss measurements a profilometer trace of each bearing was taken to measure post test wear of the bearings. In addition the bearings were visually examined and analyzed using an optical microscope.

Jett, Timothy Raymond↗

Ionospheric Signature of Surface Mine Blasts from Global Positioning System Measurements

Sources such as atmospheric or buried explosions and shallow earthquakes are known to produce infrasonic pressure waves in the atmosphere. Because of the coupling between neutral particles and electrons at ionospheric altitudes, these acoustic and gravity waves induce variations of the ionospheric electron density. The Global Positioning System (GPS) provides a way of directly measuring the total electron content in the ionosphere and, therefore, of detecting such perturbations in the upper atmosphere. In July and August 1996, three large surface mine blasts (1.5 Kt each) were detonated at the Black Thunder coal mine in eastern Wyoming. As part of a seismic and acoustic monitoring- experiment, we deployed five dual-frequency GPS receivers at distances ranging from 50 to 200 km from the mine and were able to detect the ionospheric perturbation caused by the blasts. The perturbation starts 10 to 15 min after the blast, lasts for about 30 min, and propagates with an apparent horizontal velocity of 1200 meters per second. Its amplitude reaches 3 x 10 (exp 14) el per square meters in the 7-3 min period band, a value close to the ionospheric perturbation caused by the M = 6.7 Northridge earthquake. The small signal-to-noise ratio of the perturbation can be improved by slant-stacking the electron content time-series recorded by the different GPS receivers taking into account the horizontal propagation of the perturbation. The energy of the perturbation is concentrated in the 200 to 300 second period band, a result consistent with previous observations and numerical model predictions. The 300 second band probably corresponds to gravity modes and shorter periods to acoustic modes, respectively. Using a 1-D stratified velocity model of the atmosphere we show that linear acoustic ray tracing fits arrival times at all GPS receivers. We interpret the perturbation as a direct acoustic wave caused by the explosion itself. This study shows that even relatively small subsurface events can produce ionospheric perturbations that are above the detection threshold of the GPS technique. By sensing derivative signals, which can be detected over a relatively broad region, it appears that GPS might be particularly useful for source characterization within the first acoustic quiet zone where infrasound would probably be ineffective. This suggests that dual-frequency GPS monitoring could contribute to Comprehensive Nuclear Test Ban Treaty verification.

Calais, Eric↗

Scratch-Resistant Lenses

Lewis Research Center developed a process for achieving diamond- hard coatings for aerospace systems. The technique involves coating the material with a film of diamond-like carbon (DLC) using direct ion deposition. An ion generator creates a stream of ions from a hydrocarbon gas source; the carbon ions impinge directly on the target substrate and 'grow' into a thin DLC film. In 1988, Air Products and Chemicals, Inc. received a license to the NASA patent. Diamonex, an Air Products spinoff company, further developed the NASA process to create the DiamondHard technology used on the Bausch & Lomb Ray- Ban Survivors sunglasses. The sunglasses are scratch-resistant and shed water more easily, thus reducing spotting.

Source record↗

Space-Derived Sewer Monitor

The QuadraScan Longterm Flow Monitoring System is a second generation sewer monitor developed by American Digital Systems, Inc.'s founder Peter Petroff. Petroff, a former spacecraft instrumentation designer at Marshall Space Flight Center, used expertise based on principles acquired in Apollo and other NASA programs. QuadraScan borrows even more heavily from space technology, for example in its data acquisition and memory system derived from NASA satellites. "One-time" measurements are often plagued with substantial errors due to the flow of groundwater absorbed into the system. These system sizing errors stem from a basic informational deficiency: accurate, reliable data on how much water flows through a sewer system over a long period of time is very difficult to obtain. City officials are turning to "permanent," or long-term sewer monitoring systems. QuadraScan offers many advantages to city officials such as the early warning capability to effectively plan for city growth in order to avoid the crippling economic impact of bans on new sewer connections in effect in many cities today.

Source record↗

Radicals and Reservoirs in the GMI Chemistry and Transport Model: Comparison to Measurements

The most important use of atmospheric chemistry and transport models is to predict the future composition of the atmosphere. The amounts of gases like chlorofluorcarbons, methyl bromide, nitrous oxide and methane are changing and the stratospheric ozone layer will change because these gases are changing. Methyl bromide, nitrous oxide and methane all have natural sources, and also change because of human activity. Chlorofluorcarbons are man-made gases; these are known to decrease stratospheric ozone and future production is banned. They are long-lived gases, and many decades will pass before they are insignificant in the atmosphere. The models are used to predict changes in ozone and other gases; this is a straightforward application. The models must be also tested using observations for the present day atmosphere. This is a challenging task, because the model contains more than 50 species and more than 150 chemical reactions. Data from satellites, ground stations, aircraft and balloons are used to evaluate the model. Different models that are used in international assessments produce different results; in the most recent assessment some predict that ozone will return to 1980 levels by 2025 and others predict that this will not happen until 2050. Since all the parts of the models are conceptually the same, there must be differences in implementation that produce these differences, This work takes a single model, two different sets of winds and temperatures, and repeats the same prediction for the future. Here we compare the results for these two simulations with many observations. The purpose is to identify differences in the model results for the present atmosphere that will lead to different predictions. This sort of controlled comparison will reduce uncertainty in the predictions for stratospheric ozone.

Douglas, Anne R.↗

Toward Synthesis, Analysis, and Certification of Security Protocols

Implemented security protocols are basically pieces of software which are used to (a) authenticate the other communication partners, (b) establish a secure communication channel between them (using insecure communication media), and (c) transfer data between the communication partners in such a way that these data only available to the desired receiver, but not to anyone else. Such an implementation usually consists of the following components: the protocol-engine, which controls in which sequence the messages of the protocol are sent over the network, and which controls the assembly/disassembly and processing (e.g., decryption) of the data. the cryptographic routines to actually encrypt or decrypt the data (using given keys), and t,he interface to the operating system and to the application. For a correct working of such a security protocol, all of these components must work flawlessly. Many formal-methods based techniques for the analysis of a security protocols have been developed. They range from using specific logics (e.g.: BAN-logic [4], or higher order logics [12] to model checking [2] approaches. In each approach, the analysis tries to prove that no (or at least not a modeled intruder) can get access to secret data. Otherwise, a scenario illustrating the &tack may be produced. Despite the seeming simplicity of security protocols ("only" a few messages are sent between the protocol partners in order to ensure a secure communication), many flaws have been detected. Unfortunately, even a perfect protocol engine does not guarantee flawless working of a security protocol, as incidents show. Many break-ins and security vulnerabilities are caused by exploiting errors in the implementation of the protocol engine or the underlying operating system. Attacks using buffer-overflows are a very common class of such attacks. Errors in the implementation of exception or error handling can open up additional vulnerabilities. For example, on a website with a log-in screen: multiple tries with invalid passwords caused the expected error message (too many retries). but let the user nevertheless pass. Finally, security can be compromised by silly implementation bugs or design decisions. In a commercial VPN software, all calls to the encryption routines were incidentally replaced by stubs, probably during factory testing. The product worked nicely. and the error (an open VPN) would have gone undetected, if a team member had not inspected the low-level traffic out of curiosity. Also, the use secret proprietary encryption routines can backfire, because such algorithms often exhibit weaknesses which can be exploited easily (see e.g., DVD encoding). Summarizing, there is large number of possibilities to make errors which can compromise the security of a protocol. In today s world with short time-to-market and the use of security protocols in open and hostile networks for safety-critical applications (e.g., power or air-traffic control), such slips could lead to catastrophic situations. Thus, formal methods and automatic reasoning techniques should not be used just for the formal proof of absence of an attack, but they ought to be used to provide an end-to-end tool-supported framework for security software. With such an approach all required artifacts (code, documentation, test cases) , formal analyses, and reliable certification will be generated automatically, given a single, high level specification. By a combination of program synthesis, formal protocol analysis, certification; and proof-carrying code, this goal is within practical reach, since all the important technologies for such an approach actually exist and only need to be assembled in the right way.

Schumann, Johann↗

In Situ Remediation of Polychlorinated Bephenyls Using Palladium Coated Iron or Magnesium

The remediation of polychlorinated biphenyls (PCBs) and other chlorinated synthetic aromatic compounds are of great concern due to their toxicity and persistence in the environment. When released into the environment, PCBs are sorbed to particulate matter that can then disperse over large areas. Although the US Environmental Protection Agency (EPA) has banned the manufacture of PCBs since 1979, they are still present in the environment posing possible adverse health affects to both humans and animals. Thus, it is of utmost importance to develop a method that remediates PCB-contaminated soil, sediments, and water. The objective of our research was to develop an in-situ PCB remediation technique that is applicable for the treatment of soils and sediments. Previous research conducted at the University of Central Florida (UCF) proved the feasibility of using an emulsified system to dehalogenate a dense non-aqueous phase liquid (DNAPL) source, such as TCE, in the subsurface by means of an in-situ injection. The generation of a hydrophobic emulsion system drew the DNAPL TCE, through the oil membrane where it diffused to the iron particle and underwent degradation. TCE continued to enter, diffuse, degrade and exit the droplet maintaining a concentration gradient across the membrane, thus maintaining the driving force of the reaction.

Geiger, Cherie L.↗

Quantitative Electron Probe Microanalysis: State of the Art

Quantitative electron-probe microanalysis (EPMA) has improved due to better instrument design and X-ray correction methods. Design improvement of the electron column and X-ray spectrometer has resulted in measurement precision that exceeds analytical accuracy. Wavelength-dispersive spectrometer (WDS) have layered-dispersive diffraction crystals with improved light-element sensitivity. Newer energy-dispersive spectrometers (EDS) have Si-drift detector elements, thin window designs, and digital processing electronics with X-ray throughput approaching that of WDS Systems. Using these systems, digital X-ray mapping coupled with spectrum imaging is a powerful compositional mapping tool. Improvements in analytical accuracy are due to better X-ray correction algorithms, mass absorption coefficient data sets,and analysis method for complex geometries. ZAF algorithms have ban superceded by Phi(pz) algorithms that better model the depth distribution of primary X-ray production. Complex thin film and particle geometries are treated using Phi(pz) algorithms, end results agree well with Monte Carlo simulations. For geological materials, X-ray absorption dominates the corretions end depends on the accuracy of mass absorption coefficient (MAC) data sets. However, few MACs have been experimentally measured, and the use of fitted coefficients continues due to general success of the analytical technique. A polynomial formulation of the Bence-Albec alpha-factor technique, calibrated using Phi(pz) algorithms, is used to critically evaluate accuracy issues and can be also be used for high 2% relative and is limited by measurement precision for ideal cases, but for many elements the analytical accuracy is unproven. The EPMA technique has improved to the point where it is frequently used instead of the petrogaphic microscope for reconnaissance work. Examples of stagnant research areas are: WDS detector design characterization of calibration standards, and the need for more complete treatment of the continuum X-ray fluorescence correction.

Carpernter, P. K.↗

Change in ozone trends at southern high latitudes

Long-term ozone variations at 60-70degS in spring are investigated using ground-based and satellite measurements. Strong positive correlation is shown between year-to-year variations of ozone and temperature in the Antarctic collar region in Septembers and Octobers. Based on this relationship, the effect of year-to-year variations in vortex dynamics has been filtered out. This process results in an ozone time series that shows increasing springtime ozone losses over the Antarctic until the mid-1990s. Since approximately 1997 the ozone losses have leveled off. The analysis confirms that this change is consistent across all instruments and is statistically significant at the 95% confidence level. This analysis quantifies the beginning of the recovery of the ozone hole, which is expected from the leveling off of stratospheric halogen loading due to the ban on CFCs and other halocarbons initiated by the Montreal Protocol.

Yang, E.-S.↗

Realism Assessment of Sonic Boom Simulators

Developments in small supersonic aircraft design are predicted to result in low-intensity sonic booms. Booms generated by current aircraft are similar to those that led to the ban on commercial supersonic fli ght over the US, so are unsuitable for parametric studies of psychoac oustic response to low-intensity booms. Therefore, simulators have be en used to study the impact of predicted low-intensity sonic booms. H owever, simulators have been criticized because, when simulating conv entional-level booms, the sounds were observed to be unrealistic by p eople experienced in listening to sonic booms. Thus, two studies were conducted to measure the perceived realism of three sonic boom simul ators. Experienced listeners rated the realism of conventional sonic boom signatures when played in these simulators. The effects on percei ved realism of factors such as duration of post-boom noise, exclusion of very low frequency components, inclusion of ground reflections, a nd type of simulator were examined. Duration of post-boom noise was f ound to have a strong effect on perceived realism, while type of simu lator had a weak effect. It was determined that post-boom noise had t o be at least 1.5 seconds long for the sound to be rated very realist ic. Loudness level did not affect realism for the range of sounds pla yed in the tests (80-93 dB ASEL).

Sullivan, Brenda M.↗

An Approach to Improved Credibility of CFD Simulations for Rocket Injector Design

Computational fluid dynamics (CFD) has the potential to improve the historical rocket injector design process by simulating the sensitivity of performance and injector-driven thermal environments to. the details of the injector geometry and key operational parameters. Methodical verification and validation efforts on a range of coaxial injector elements have shown the current production CFD capability must be improved in order to quantitatively impact the injector design process.. This paper documents the status of an effort to understand and compare the predictive capabilities and resource requirements of a range of CFD methodologies on a set of model problem injectors. Preliminary results from a steady Reynolds-Average Navier-Stokes (RANS), an unsteady Reynolds-Average Navier Stokes (URANS) and three different Large Eddy Simulation (LES) techniques used to model a single element coaxial injector using gaseous oxygen and gaseous hydrogen propellants are presented. Initial observations are made comparing instantaneous results, corresponding time-averaged and steady-state solutions in the near -injector flow field. Significant differences in the flow fields exist, as expected, and are discussed. An important preliminary result is the identification of a fundamental mixing mechanism, accounted for by URANS and LES, but missing in the steady BANS methodology. Since propellant mixing is the core injector function, this mixing process may prove to have a profound effect on the ability to more correctly simulate injector performance and resulting thermal environments. Issues important to unifying the basis for future comparison such as solution initialization, required run time and grid resolution are addressed.

Tucker, Paul K.↗

Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher

A fine-water-mist fire-suppression device has been designed so that it can be discharged uniformly in any orientation via a high-pressure gas propellant. Standard fire extinguishers used while slightly tilted or on their side will not discharge all of their contents. Thanks to the new design, this extinguisher can be used in multiple environments such as aboard low-gravity spacecraft, airplanes, and aboard vehicles that may become overturned prior to or during a fire emergency. Research in recent years has shown that fine water mist can be an effective alternative to Halons now banned from manufacture. Currently, NASA uses carbon dioxide for fire suppression on the International Space Station (ISS) and Halon chemical extinguishers on the space shuttle. While each of these agents is effective, they have drawbacks. The toxicity of carbon dioxide requires that the crew don breathing apparatus when the extinguishers are deployed on the ISS, and Halon use in future spacecraft has been eliminated because of international protocols on substances that destroy atmospheric ozone. A major advantage to the new system on occupied spacecraft is that the discharged system is locally rechargeable. Since the only fluids used are water and nitrogen, the system can be recharged from stores of both carried aboard the ISS or spacecraft. The only support requirement would be a pump to fill the water and a compressor to pressurize the nitrogen propellant gas. This system uses a gaseous agent to pressurize the storage container as well as to assist in the generation of the fine water mist. The portable fire extinguisher hardware works like a standard fire extinguisher with a single storage container for the agents (water and nitrogen), a control valve assembly for manual actuation, and a discharge nozzle. The design implemented in the proof-of-concept experiment successfully extinguished both open fires and fires in baffled enclosures.

Butz, James R.↗

Selection of Environmentally Friendly Solvents for the Extravehicular Mobility Unit Secondary Oxygen Pack Cold Trap Testing

Freon-113(TradeMark) has been used as a chemistry lab sampling solvent at NASA/JSC for EMU (extravehicular Mobility Unit) SOP (Secondary Oxygen Pack) oxygen testing Cold Traps utilized at the USA (United Space Alliance) Houston facility. Similar testing has occurred at the HSWL (Hamilton Sundstrand Windsor Locks) facility. A NASA Executive Order bans the procurement of all ODS (ozone depleting substances), including Freon-113 by the end of 2009. In order to comply with NASA direction, HSWL began evaluating viable solvents to replace Freon-113 . The study and testing effort to find Freon-113 replacements used for Cold Trap sampling is the subject of this paper. Test results have shown HFE-7100 (a 3M fluorinated ether) to be an adequate replacement for Freon-113 as a solvent to remove and measure the non-volatile residue collected in a Cold Trap during oxygen testing. Furthermore, S-316 (a Horiba Instruments Inc. high molecular weight, non-ODS chlorofluorocarbon) was found to be an adequate replacement for Freon-113 as a solvent to reconstitute non-volatile residue removed from a Cold Trap during oxygen testing for subsequent HC (hydrocarbon) analysis via FTIR (Fourier Transform Infrared Spectroscopy).

Steele, John↗

Developments and Validations of Fully Coupled CFD and Practical Vortex Transport Method for High-Fidelity Wake Modeling in Fixed and Rotary Wing Applications

A novel Computational Fluid Dynamics (CFD) coupling framework using a conventional Reynolds-Averaged Navier-Stokes (BANS) solver to resolve the near-body flow field and a Particle-based Vorticity Transport Method (PVTM) to predict the evolution of the far field wake is developed, refined, and evaluated for fixed and rotary wing cases. For the rotary wing case, the RANS/PVTM modules are loosely coupled to a Computational Structural Dynamics (CSD) module that provides blade motion and vehicle trim information. The PVTM module is refined by the addition of vortex diffusion, stretching, and reorientation models as well as an efficient memory model. Results from the coupled framework are compared with several experimental data sets (a fixed-wing wind tunnel test and a rotary-wing hover test).

Anusonti-Inthra, Phuriwat↗

Chemical Loss of Polar Ozone: Present Understanding and Remaining Uncertainties

Not long after the discovery of the Antarctic ozone hole, it was established that halogen compounds, supplied to the atmosphere mainly by anthropogenic activities, are the primary driver of polar ozone loss. We will briefly review the chemical mechanisms that cause polar ozone loss and the early evidence showing the key role played by anthropogenic halogens. Recently, stratospheric halogen loading has leveled off, due to adherence to the Montreal Protocol and its amendments that has essentially banned CFCs (chlorofluorocarbons) and other halocarbons. We will describe recent reports of the first stage of recovery of the Antarctic ozone hole (e.g., a statistically significant slowing of the downward trend), associated with the leveling off of stratospheric halogens. Despite this degree of understanding, we will discuss the tendency of photochemical models to underestimate the observed rate of polar ozone loss and a hypothesis that has recently been put forth that might resolve this discrepancy. Finally, we will briefly discuss chemical loss of Arctic ozone, which

climate change↗