Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam broadening”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Resonant Doppler velocimeter

A technique is presented for visualizing and quantitatively measuring velocity, temperature, and pressure by shining a single frequency laser beam into a gaseous flow which is seeded with an atomic species. The laser is tuned through the absorption frequencies of the seeded species and the absorption profile is detected by observing fluorescence as the atoms relax back to the ground state. The flow velocity is determined by observing the Doppler shift in the absorption frequency. Spectroscopic absorption line broadening mechanisms furnish information regarding the static temperature and pressure of the moving gas. Results of experiments conducted in the free stream and in the bow shock of a conical model mounted in a hypersonic wind tunnel indicate that the experimental uncertainties in the measurement of average values for the velocity, temperature and pressure of the flow are 0.1, 5 and 10 percent respectively.

Zimmermann, M.↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3x10(exp 17) and 9x10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Strongly-Refractive One-Dimensional Photonic Crystal Prisms

One-dimensional (1D) photonic crystal prisms can separate a beam of polychromatic electromagnetic waves into constituent wavelength components and can utilize unconventional refraction properties for wavelength dispersion over significant portions of an entire photonic band rather than just near the band edges outside the photonic band gaps. Using a ID photonic crystal simplifies the design and fabrication process and allows the use of larger feature sizes. The prism geometry broadens the useful wavelength range, enables better optical transmission, and exhibits angular dependence on wavelength with reduced non-linearity. The properties of the 1 D photonic crystal prism can be tuned by varying design parameters such as incidence angle, exit surface angle, and layer widths. The ID photonic crystal prism can be fabricated in a planar process, and can be used as optical integrated circuit elements.

Ting, David Z.↗

Simultaneous measurements of velocity, temperature, and pressure using rapid CW wavelength-modulation laser-induced fluorescence of OH

The beam from a rapid-tuning single-frequency laser was used to probe the R1(7) and R1(11) A2Sigma(+) - X2Pi(0,0) line pair of OH at a 45-deg incident angle in a combustion-driven, supersonic free jet. Absorption line shapes were recorded in spatially resolved, single-point fluorescence. The Doppler shift, intensity ratio, and collisional broadening of the measured line pair were used to determine velocity, temperature, and pressure. The repetition rate of the measurement was 3 kHz.

Chang, A. Y.↗

Thermodynamic measurements in a high pressure hydrogen-oxygen flame using Raman scattering from a broadband excimer laser

Raman scattering is an inelastic molecular scattering process in which incident radiation is reemitted at a fixed change in frequency. Raman spectroscopy can be used to measure the number density and temperature of the irradiated species. The strength of the Raman signal is inversely proportional to the wavelength raised to the fourth power. Consequently, high signal to noise ratios are obtained by using ultraviolet (UV) excitation sources. Using UV sources for Raman Spectroscopy in flames is complicated by the fact that some of the primary constituents in hydrogen-oxygen combustion absorb and reemit light in the UV and these fluorescence processes interfere with the Raman signals. This problem has been handled in atmospheric pressure flames in some instances by using a narrowband tunable excimer laser as a source. This allows for detuning from absorption transitions and the elimination of interfering fluorescence signals at the Raman wavelengths. This approach works well in the atmospheric pressure flame; however, it has two important disadvantages. First, injection-locked narrowband tunable excimer lasers are very expensive. More importantly, however, is the fact that at the high pressures characteristic of rocket engine combustion chambers, the absorption transitions are broadened making it difficult to tune to a spectral location at which substantial absorption would not occur. The approach taken in this work is to separate the Raman signal from the fluorescence background by taking advantage of the fact that Raman signal has nonisotropic polarization characteristics while the fluorescence signals are unpolarized. Specifically, for scattering at right angles to the excitation beam path, the Raman signal is completely polarized. The Raman signal is separated from the fluorescence background by collecting both horizontally and vertically polarized signals separately. One of the polarizations has both the Raman signal and the fluorescence background while the other has only the fluorescence signal. The Raman scatter is the difference between the signals. By choosing an appropriate optical setup, both signals can be obtained simultaneously with the same monochromator; hence, time resolved measurements are possible using this approach.

Hartfield, Roy, Jr.↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17)/cu cm. The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

Meyer, Scott Andrew↗

Two-stage nonlinear compression of high-power femtosecond laser pulses

Two-stage compression of laser pulses with a power of 250 TW is experimentally realised by broadening their spectrum during self-phase modulation in fused silica and subsequent dispersion compensation upon reflection from chirping mirrors. A five-fold decrease in the duration is demonstrated, from 75 to 15 fs, with a B-integral value of about 5 at each stage. It is possible to avoid small-scale self-focusing due to self-filtering of the laser beam during free propagation in vacuum. With optimal parameters of the dispersive mirror, the pulse can be compressed to a duration of less than 5 fs. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New methodology for measuring electron density perturbations caused by plasma coherent modes using profile reflectometry: Magnitudes and radial profiles in DIII-D

New capabilities of fast-sweep frequency-modulated profile reflectometry are explored to measure electron density ne perturbation magnitudes and radial profiles due to plasma coherent modes in DIII-D. The first approach is based on the frequency analysis of phase perturbations associated with high frequency (~MHz) Alfvén eigenmodes (AEs). The measurement of ~5.5 MHz fast-ion-driven global Alfvén eigenmodes (GAEs) is demonstrated in a neutral beam-heated DIII-D plasma. The GAE induced a broad radial distribution of phase perturbations in the profile reflectometer data. Analysis of these data determined the effective cutoff location displacement and the estimated ne fluctuation profile. In the second approach, high resolution ne profiles are used directly to determine the radial structure of ne perturbations due to a neo-classical tearing mode. These new measurements broaden the application of profile reflectometry and advance the development of AE spectroscopy as a tool for non-invasive diagnosis of fast-ion-driven modes in DIII-D and burning plasmas such as ITER.

47 OTHER INSTRUMENTATION↗

Neutron-Resonance Transmission Analysis with a Compact Deuterium-Tritium Neutron Generator

Neutron Resonance Transmission Analysis (NRTA) is a spectroscopic technique which uses the resonant absorption of neutrons in the epithermal range to infer the isotopic composition of an object. This spectroscopic technique has relevance in many traditional fields of science and nuclear security. NRTA in the past made use of large, expensive accelerator facilities to achieve precise neutron beams, significantly limiting its applicability. Here, we describe a series of NRTA experiments where we use a compact, low-cost deuterium-tritium (DT) neutron generator to produce short neutron beams (2.6 m) along with a 6 Li-glass neutron detector. The time-of-flight spectral data from five elements – silver, cadmium, tungsten, indium, and 238 U – clearly show the corresponding absorption lines in the 1-30 eV range. The experiments show the applicability of NRTA in this simplified configuration, and prove the feasibility of this compact and low-cost approach. This could significantly broaden the applicability of NRTA, and make it practical and applicable in many fields, such as material science, nuclear engineering, and arms control.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Potential of Phased Arrays for Planetary Exploration

Phased array antennas provide a set of operational capabilities which are very attractive for certain mission applications and not very attractive for others. Such antennas are by no means a panacea for telecommunications. In this paper the features of phased arrays are reviewed and their implications for space missions are considered in terms of benefits and costs. The primary capability provided by a phased array is electronic beam agility. The beam direction may be controlled at electronic speeds (vs. mechanical actuation) permitting time division multiplexing of multiple "users." Moreover, the beam direction can be varied over a full hemisphere (for a planar array). On the other hand, such antennas are typically much more complicated than the more commonly used reflectors and horns and this implies higher cost. In some applications, this increased cost must be accepted if the mission is to be carried out at all. The SIR-C radar is an example of such a case albeit not for deep space. Assuming for the sake of argument that the complexity and cost of a phased array can be significantly reduced, where can such antennas be of value in the future of planetary exploration? Potential applications to be discussed are planetary rovers, landers, and orbiters including both the areosynchronous and low orbit varieties. In addition, consideration is given to links from deep space to earth. As may be fairly obvious, the deep space link to earth would not benefit from the wide angle steering capability provided by a phase array whereas a rover could gain advantage from the capability to steer a beam anywhere in the sky. In the rover case, however, physical size of the aperture becomes a significant factor which, of course, has implications regarding the choice of frequency band. Recent research work concerning phased arrays has suggested that future phased arrays might be made less complex and, therefore, less costly. Successful realization of such phased arrays would enable many of the planetary missions discussed in this paper and significantly broaden the telecommunications capabilities available to the mission designers of the future.

Pogorzelski, Ronald J.↗

Insights into Native Single-Atom Electrocatalyst Site Structures

Single-atom electrocatalysts consisting of metal atoms embedded in a carbon matrix are promising next-generation catalysts for green hydrogen production and utilization, CO2 reduction, low-temperature CO oxidation, ammonia production, plastic decomposition, and electrochemical energy storage. The origins of activity and stability for the single-atom sites are still debatable, however, because of constrained insights into their local structure resulting from idealized models and experiments derived from a large number of individual sites. Insights into structural variations around single atomic sites are therefore critical for the continued development of these next-generation catalysts. While electron microscopy commonly provides atomic-scale information about these materials, the beam sensitivity of individual sites makes structural determination by conventional low-voltage (60 keV) techniques challenging. Here, we introduce ultralow-voltage electron ptychography, performed at 30 keV, that enables determination of the lattice structure around individual metal sites in a well-defined single-atom electrocatalyst system while essentially eliminating knock-on structural modifications. Pairing these atomic-scale, site-specific measurements with computational methods will broaden our understanding of the activity and stability of these materials, which will accelerate the development of the next generation of catalysts.

Zachman, Michael [ORNL] (ORCID:0000000319101357)↗

Effects of radiation damage on the silicon lattice

Silicon was irradiated with both proton and electron particle beams in order to investigate changes in the structural and optical properties of the lattice as a result of the radiation damage. Lattice expansions occurred when large strain fields (+0.34 percent) developed after 1- and 3-MeV proton bombardment. The strain was a factor of three less after 1-MeV electron irradiation. Average increases of approximately 22 meV in the 3.46-eV interband energy gap and 14 meV in the Lorentz broadening parameter were measured after the electron irradiation.

Dumas, Katherine A.↗

Determination of physically based pseudo-Voigt powder diffraction profile terms from the fundamental parameters approach

In this study, a methodology is developed where a fundamental parameters approach (FPA) description of a laboratory powder diffraction instrument (configured in divergent-beam Bragg–Brentano geometry) is used to determine GSAS-II profile parameters for peak asymmetry and instrumental peak widths. This allows the instrumental contribution to peak shapes to be robustly determined directly from a physical description of the instrument, even though GSAS-II does not directly implement FPA for peak shape computation. The FPA-derived parameters can be used as the starting point for instrument characterization, or to characterize sample broadening without the use of a standard to determine the instrument profile function. This new method can facilitate generation of training sets for machine learning. A plot is generated that shows the differences between the two approaches, demonstrating upper bounds for the accuracy of the GSAS-II profile model for a particular instrumental configuration.

47 OTHER INSTRUMENTATION↗

In situ counter-diffusion crystallization and long-term crystal preservation in microfluidic fixed targets for serial crystallography

Compared with batch and vapor diffusion methods, counter diffusion can generate larger and higher-quality protein crystals yielding improved diffraction data and higher-resolution structures. Typically, counter-diffusion experiments are conducted in elongated chambers, such as glass capillaries, and the crystals are either directly measured in the capillary or extracted and mounted at the X-ray beamline. Despite the advantages of counter-diffusion protein crystallization, there are few fixed-target devices that utilize counter diffusion for crystallization. In this article, different designs of user-friendly counter-diffusion chambers are presented which can be used to grow large protein crystals in a 2D polymer microfluidic fixed-target chip. Methods for rapid chip fabrication using commercially available thin-film materials such as Mylar, propylene and Kapton are also detailed. Rules of thumb are provided to tune the nucleation and crystal growth to meet users' needs while minimizing sample consumption. These designs provide a reliable approach to forming large crystals and maintaining their hydration for weeks and even months. This allows ample time to grow, select and preserve the best crystal batches before X-ray beam time. Importantly, the fixed-target microfluidic chip has a low background scatter and can be directly used at beamlines without any crystal handling, enabling crystal quality to be preserved. The approach is demonstrated with serial diffraction of photoactive yellow protein, yielding 1.32 Å resolution at room temperature. Fabrication of this standard microfluidic chip with commercially available thin films greatly simplifies fabrication and provides enhanced stability under vacuum. These advances will further broaden microfluidic fixed-target utilization by crystallographers.

Liu, Zhongrui↗

Integrated reflector antenna design and analysis

Reflector antenna design is a mature field and most aspects were studied. However, of that most previous work is distinguished by the fact that it is narrow in scope, analyzing only a particular problem under certain conditions. Methods of analysis of this type are not useful for working on real-life problems since they can not handle the many and various types of perturbations of basic antenna design. The idea of an integrated design and analysis is proposed. By broadening the scope of the analysis, it becomes possible to deal with the intricacies attendant with modem reflector antenna design problems. The concept of integrated reflector antenna design is put forward. A number of electromagnetic problems related to reflector antenna design are investigated. Some of these show how tools for reflector antenna design are created. In particular, a method for estimating spillover loss for open-ended waveguide feeds is examined. The problem of calculating and optimizing beam efficiency (an important figure of merit in radiometry applications) is also solved. Other chapters deal with applications of this general analysis. The wide angle scan abilities of reflector antennas is examined and a design is proposed for the ATDRSS triband reflector antenna. The development of a general phased-array pattern computation program is discussed and how the concept of integrated design can be extended to other types of antennas is shown. The conclusions are contained in the final chapter.

Zimmerman, M. L.↗

Creation and characterization of warm dense matter isochorically heated by an intense laser-driven proton beam to temperatures exceeding 100 eV

The warm dense matter (WDM) is an exotic state of matter encountered in inertial confinement implosions for fusion energy, as well as the interiors of giant planets like Jupiter, brown dwarfs, the atmospheres of white dwarfs, neutron star crusts, and newly discovered exo-planets. One efficient way to create WDM is to use protons accelerated by a high-intensity short-pulse laser to isochorically heat dense samples to WDM states. Despite its importance, direct temperature measurements within WDM targets are scarce. This study utilizes an intense proton beam generated by the kilojoule EP laser further focused and guided by a curved foil and cone structure to efficiently heat a thin copper sample. A high-resolution streaked spectrometer tuned to copper K α fluorescence lines provided bulk temperature measurements every ~2 ps, revealing temperatures exceeding 100 eV in under 50 ps. Particle-in-cell simulations of proton transport and energy deposition closely matched the observed heating dynamics, including transverse temperature gradients revealed by the broadening of K α lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory tests of CO2 laser collective Thomson scattering for measurements of ion temperature in the divertor

Collective Thomson scattering (CTS) is a diagnostic method that measures the ion velocity distribution of a plasma. CO2 laser CTS measurements are challenging because of the inherently small Doppler broadening and scattering signals that are difficult to detect. We implemented a heterodyne detection scheme to measure spectrum changes of less than a GHz. To maximize the collected light at small scattering angles, we designed a unique light collection approach consisting of a customized conical-shaped (axicon) lens with a hole in the center. The axicon lens is used to collect the scattered light emitted within an annular cross-section from the scattering volume while the probe beam is passed through the hole at the center of the lens. The performance of the heterodyne detection scheme and annular collection approach was demonstrated using a Transverse Excited Atmospheric pressure CO2 laser with a pulse energy of 160 mJ at λ = 10.59 µm.

Instruments & Instrumentation↗