Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam independence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A new method for measuring the 3D turbulent velocity dispersion of molecular clouds

ABSTRACT The structure and star formation activity of a molecular cloud are fundamentally linked to its internal turbulence. However, accurately measuring the turbulent velocity dispersion is challenging due to projection effects and observational limitations, such as telescope resolution, particularly for clouds that include non-turbulent motions, such as large-scale rotation. Here, we develop a new method to recover the 3D turbulent velocity dispersion (σv,3D) from position–position–velocity (PPV) data. We simulate a rotating, turbulent, collapsing molecular cloud, and compare its intrinsic σv,3D with three different measures of the velocity dispersion accessible in PPV space: (1) the spatial mean of the 2nd-moment map, σi, (2) the standard deviation of the gradient/rotation-corrected 1st-moment map, σ(c − grad), and (3) a combination of (1) and (2), called the ‘gradient-corrected parent velocity dispersion’, $\sigma _{\mathrm{(p}-\mathrm{grad)}}=(\sigma _{\mathrm{i}}^2+\sigma _{(\mathrm{c}-\mathrm{grad)}}^2)^{1/2}$. We show that the gradient correction is crucial in order to recover purely turbulent motions of the cloud, independent of the orientation of the cloud with respect to the line of sight. We find that with a suitable correction factor and appropriate filters applied to the moment maps, all three statistics can be used to recover σv,3D, with method 3 being the most robust and reliable. We determine the correction factor as a function of the telescope beam size for different levels of cloud rotation, and find that for a beam full width at half-maximum f and cloud radius R, the 3D turbulent velocity dispersion can best be recovered from the gradient-corrected parent velocity dispersion via $\sigma _{v,\mathrm{3D}}= \left[(-0.29\pm 0.26)\, f/R + 1.93 \pm 0.15\right] \sigma _{\mathrm{(p}-\mathrm{grad)}}$ for f/R < 1, independent of the level of cloud rotation or LOS orientation.

Stewart, Madeleine↗

Using spin alignment of inelastically excited nuclei in fast beams to assign spins: The spectroscopy of 13 O as a test case

Excited states in O 13 were investigated using inelastic scattering of an E / A = 69.5 MeV O 13 beam off of a Be 9 target. The excited states were identified in the invariant-mass spectra of the decay products. Both single-proton and sequential two-proton decays of the excited states were examined. Furthermore, for a number of the excited states, the protons were emitted with strong anisotropy where emissions transverse to the beam axis are favored. The measured proton-decay angular distributions were compared to predictions from distorted-wave Born-approximation calculations of the spin alignment which was shown to be largely independent of the excitation mechanism. The deduced O 13 level scheme is compared to ab initio no-core shell model with continuum predictions. The lowest-energy excited states decay isotropically consistent with predictions of strong proton 1 s 1 / 2 structure. Above these states in the level scheme, we observed a number of higher-spin states not predicted within the model. Possibly these are associated with rotational bands built on deformed cluster configurations predicted by antisymmetrized molecular dynamics calculations. The spin alignment mechanism is shown to be useful for making spin assignments and may have widespread use.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Searching for Sterile Neutrinos In the NOvA Experiment and Measurements of Hadronic Energy Response with NOvA Test Beam Data

The NOvA (NuMI Off-Axis electron neutrino Appearance) experiment is a long-baseline neutrino oscillation experiment composed of two functionally identical detectors: a 300-ton Near Detector and a 14-kton Far Detector, separated by 809 km and placed 14 mrad off the axis of the NuMI neutrino beam created at Fermilab. This configuration enables NOvA’s rich neutrino physics program, which includes measuring neutrino mixing parameters, determining the neutrino mass hierarchy, probing CP violation in the leptonic sector, studying neutrino cross sections, searching for sterile neutrinos, and more.\\ In this thesis I will present two independent analyses developed within the NOvA experiment. The first is a search for light sterile neutrino oscillations in the 3+1 framework using $\nu_\mu$-CC and NC samples from the NOvA Near and Far Detectors. Light sterile neutrinos are hypothetical neutral leptons that do not participate in the weak interactions but can mix with the three known active neutrinos: $\nu_e$, $\nu_\mu$, and $\nu_\tau$. Anomalous results, such as $\nu_e$/$\bar{\nu}e$ appearance in a $\nu_\mu$ ($\bar{\nu}_\mu$) beam observed by the MiniBooNE and LSND experiments, can be explained by the existence of sterile neutrinos. Thus, proving the existence of this type of neutrino is essential. The latest results of these searches in the NOvA experiment, along with contributions to this effort, will be presented.\\ The second is the first measurement of the pion energy response using data from the NOvA Test Beam experiment. The NOvA Test Beam experiment, deployed at Fermilab, uses a scaled-down 30-ton NOvA detector to analyze tagged beamline particles. The beamline can select and identify electrons, muons, pions, kaons, and protons with momenta ranging from 0.4 to 1.4 GeV/c. Pions are an important component of the hadronic system in neutrino interactions, and understanding how the detector responds to these particles is crucial for the validation of the simulation and the reduction of detector calibration uncertainties, which remain one of the largest systematic uncertainties in NOvA analyses.

Dueñas Tonguino, David Francisco [Cincinnati U.] (↗

Progress in modelling fast-ion D-alpha spectra and neutral particle analyzer fluxes using FIDASIM

FIDASIM is a code that models signals produced by charge-exchange reactions between neutrals and ions (both fast and thermal) in magnetically confined plasmas. With the ion distribution function as input, the code predicts the efflux to a neutral particle analyzer diagnostic and the photon radiance of Balmer-alpha light to a fast-ion D α diagnostic, in addition to many other related quantities. A new, parallelized version of the Monte Carlo code FIDASIM has been developed in Fortran90 that is substantially faster than the original interactive data language version. Modified algorithms include more accurate treatments of the time dependent collisional-radiative equations that describe neutral energy levels, of the cloud of ‘halo’ neutrals that surround the injected neutral beam, and of finite Larmor radius effects. Enhanced physics capabilities include modelling ‘passive’ signals from cold edge neutrals, the ability to treat general three-dimensional magnetic confinement configurations, and calculations of diagnostic-specific weight functions that enable tomographic reconstructions of the fast-ion distribution function. Neutral beam attenuation, beam emission, and fast-ion birth profiles are also modelled. Finally, the new algorithms have been successfully validated against experimental data and new features have been tested through benchmarks between two independently developed versions of the code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultimate Precision on Sin^2 Theta_23 With the Numi Experiments

There were two major goals to this proposal: the study of the discrepancy between data and MC in the NuMI Medium Energy neutrino beam and the incorporation of the MINOS and NOVA neutrino oscillation datasets. The first topic was approached via development of a simulation of the NuMI beam monitoring instrumentation suite. Initially, the Horn-Off current data sets were used to measure a set of hadron production parameters which improved the data/MC agreement in a way which was independent of the focusing parameters. The peak position discrepancy was only explained by a large (10kA) reduction in the horn current. A full simulation of the muon monitors was developed to attempt to make an independent measurement of the horn current by means of differential data taken by those monitors. While only at the 5kA level, the result corroborated the former findings. The second goal has not yet been completed but progress has focused on understanding how to modify the MINOS MC to take into account the MEC contribution which is missing from the underlying NEUGEN MC. A number of improvements to the MINOS reconstruction have been necessary. The framework to run the fits on the combined data has been completed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for a Long-Lived $\mu\mu$ Resonance in the NuMI Beam at ICARUS

The ICARUS detector in the Short-Baseline Neutrino program at Fermilab is sensitive to “long-lived” new physics particles that would be produced in the Neutrinos at the Main Injector (NuMI) beam and decay inside the ICARUS liquid argon time projection chamber (LArTPC). We show results from a new analysis in ICARUS which searched for di-muon decays from a long-lived particle produced in kaon decay in the NuMI beam. The search is sensitive to new areas of parameter space for the Higgs portal scalar and an axion-like particle model. The sensitivity is also presented in a model-independent way applicable to any new physics model predicting the process $K \to \pi+S(\to\mu\mu)$, for a long-lived particle S. This is the first search for new physics performed with the ICARUS detector at Fermilab. It paves the way for the future program of long-lived particle searches at ICARUS.

43 PARTICLE ACCELERATORS↗

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

A Study of the Radiation Tolerance of CVD Diamond to 70 MeV Protons, Fast Neutrons and 200 MeV Pions

We measured the radiation tolerance of commercially available diamonds grown by the Chemical Vapor Deposition process by measuring the charge created by a 120 GeV hadron beam in a 50 μm pitch strip detector fabricated on each diamond sample before and after irradiation. We irradiated one group of samples with 70 MeV protons, a second group of samples with fast reactor neutrons (defined as energy greater than 0.1 MeV), and a third group of samples with 200 MeV pions, in steps, to (8.8±0.9) × 1015 protons/cm2, (1.43±0.14) × 1016 neutrons/cm2, and (6.5±1.4) × 1014 pions/cm2, respectively. By observing the charge induced due to the separation of electron–hole pairs created by the passage of the hadron beam through each sample, on an event-by-event basis, as a function of irradiation fluence, we conclude all datasets can be described by a first-order damage equation and independently calculate the damage constant for 70 MeV protons, fast reactor neutrons, and 200 MeV pions. We find the damage constant for diamond irradiated with 70 MeV protons to be 1.62±0.07(stat)±0.16(syst)× 10−18 cm2/(p μm), the damage constant for diamond irradiated with fast reactor neutrons to be 2.65±0.13(stat)±0.18(syst)× 10−18 cm2/(n μm), and the damage constant for diamond irradiated with 200 MeV pions to be 2.0±0.2(stat)±0.5(syst)× 10−18 cm2/(π μm). The damage constants from this measurement were analyzed together with our previously published 24 GeV proton irradiation and 800 MeV proton irradiation damage constant data to derive the first comprehensive set of relative damage constants for Chemical Vapor Deposition diamond. We find 70 MeV protons are 2.60 ± 0.29 times more damaging than 24 GeV protons, fast reactor neutrons are 4.3 ± 0.4 times more damaging than 24 GeV protons, and 200 MeV pions are 3.2 ± 0.8 more damaging than 24 GeV protons. We also observe the measured data can be described by a universal damage curve for all proton, neutron, and pion irradiations we performed of Chemical Vapor Deposition diamond. Finally, we confirm the spatial uniformity of the collected charge increases with fluence for polycrystalline Chemical Vapor Deposition diamond, and this effect can also be described by a universal curve.

36 MATERIALS SCIENCE↗

McMillan map and nonlinear Twiss parameters

In this article we consider two dynamical systems: the McMillan sextupole and octupole integrable mappings originally introduced by Edwin McMillan; the second one is also known as canonical McMillan map. Both of them are simplest symmetric McMillan maps with only one intrinsic parameter, the trace of the Jacobian at the fixed point. While these dynamical systems have numerous of applications and are used in many areas of math and physics, some of their dynamical properties have not been described yet. We fulfill the gap and provide complete description of all stable trajectories including parametrization of invariant curves, Pioncaré rotation numbers and canonical action-angle variables. In the second part we relate these maps with general chaotic map in McMillan-Turaev form. We show that McMillan sextupole and octupole mappings are first order approximations of dynamics around the fixed point, in a similar way as linear map and quadratic invariant (Courant-Snyder invariant in accelerator physics) is the zeroth order approximation (known as linearization). Finally we suggest the new formalism of nonlinear Twiss parameters which incorporate dependence of rotation number as a function of amplitude, in contrast to e.g. betatron phase advance used in accelerator physics which is independent of amplitude. Specifically in application to accelerator physics this new formalism is capable of predicting dynamical aperture around 1-st, 2-nd, 3-rd and 4-th order resonances for flat beams, which is critical for beam injection/extraction.

43 PARTICLE ACCELERATORS↗

STUDY OF THE η'π 0 SYSTEM IN GLUEX

The η'π is an important decay channel for the potentially exotic hybrid meson π 1 (1600) that has been detected in the COMPASS, VES and E852 experiments. These previous experiments used a charged pion beam as a probe. In contrast, the GlueX experiment is designed to search for the exotic hybrid mesons using a linearly polarized photon beam. This thesis project analyzes the η'π 0 system produced in GlueX by the reaction γp → η'π 0 p. After optimizing the event selection to minimize background contributions, a mass independent partial wave analysis is performed in search of an exotic signature. Within the currently available statistical precision, no signal was found.

Dotel, Rupesh↗

Relations between Shot Noise, Gain Bandwidth, and Saturation of Instabilities

There are numerous instabilities present in charged particle beams that undergo exponential growth and reach saturation. In various applications, such as free-electron lasers or micro-bunching light sources, achieving saturation is desirable. Conversely, there are applications where these instabilities are utilized as linear broad-band amplifiers for signals embedded in the charged beam. In the latter scenario, the saturation of an instability induces non-linear distortions in the imprinted signal, thereby limiting the useful range of such amplifiers. Accurate evaluation of these instabilities necessitates a complete and comprehensive modeling approach that includes shot noise within the beam. Unfortunately, such modeling is not always feasible or practical. In this paper, we introduce a methodology utilizing the frequency and bandwidth of the instability as key parameters. Through this, we derive an estimation for the range of linear instability growth. Our derivation is conducted in a model-independent manner, making it applicable to a broad spectrum of instabilities. To validate our approach, we employ established and thoroughly benchmarked simulations with a free electron laser (FEL) code as well as self-consistent 3-dimensional simulation of plasma-cascade instability using code SPACE.

43 PARTICLE ACCELERATORS↗

Proton-induced reactions on Fe, Cu, and Ti from threshold to 55 MeV

Theoretical models often differ significantly from measured data in their predictions of the magnitude of nuclear reactions that produce radionuclides for medical, research, and national security applications. In this paper, we compare a priori predictions from several state-of-the-art reaction modeling packages (CoH, EMPIRE, TALYS, and ALICE) to cross sections measured using the stacked-target activation method. The experiment was performed using the Lawrence Berkeley National Laboratory 88-Inch Cyclotron with beams of 25 and 55 MeV protons on a stack of iron, copper, and titanium foils. Thirty-four excitation functions were measured from 4–55 MeV, including the first measurement of the independent cross sections for nat Fe(p,x) 49,51 Cr, 51,52m,52g,56 Mn, and 58m,58g Co. All of the models, using default input parameters to assess their predictive capabilities, failed to reproduce the isomer-to-ground state ratio for reaction channels at compound and pre-compound energies, suggesting issues in modeling the deposition or distribution of angular momentum in these residual nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DUNE-PRISM – A New Method to Measure Neutrino Oscillations

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long baseline neutrino oscillation experiment designed to make precision measurements in a 1.2 2.4 MW neutrino beam, which is directed 1285 km from the Fermi National Accelerator Laboratory (Fermilab) to the Sandford Underground Research Facility (SURF) in South Dakota. Neutrinos are measured at two detector facilities: a near detector located at Fermilab close where the beam is produced and a far detector at SURF. The neutrino beam can be configured to be composed primarily of either muon or anti-muon neutrinos. DUNE measures the disappearance of muon and anti-muon neutrinos and appearance electron and anti-electron neutrinos in the neutrino beam. Measuring these neutrino flavour transitions provides DUNE with sensitivity to the neutrino mass ordering, $\delta_{CP}$, $\theta_{13}$, $\theta_{23}$ and the magnitude of $\Delta m^2_{23}$. The DUNE Precision Reaction Independent Spectrum Measurement (DUNE-PRISM) concept presents a novel way to perform a neutrino oscillation analysis, which has the potential to significantly reduce the impact of large systematic uncertainties in the neutrino interaction model. The PRISM method linearly combines measurements of off-axis neutrino interactions at the DUNE near detector to produce data-driven predictions of the oscillated neutrino event rate spectrum at the far detector. By building an oscillated far detector prediction directly from data, any unknown or poorly modelled neutrino interaction effects will be naturally incorporated into the measurement of the parameters of the neutrino oscillation model. This thesis presents the first complete neutrino oscillation analysis for DUNE using the PRISM method. Details of the methodology are fully explained and the prospects for further improvements to the techniques described are highlighted. The expected impact and relative importance of the neutrino flux, cross section and detector systematic uncertainties are described in detail. Finally, this thesis demonstrates that the PRISM method is capable of performing a measurement of the oscillation parameters that is robust against neutrino interaction modelling errors.

Hasnip, Ciaran↗

Higgs boson width and couplings at high energy muon colliders with forward muon detection

We propose a novel method using the ZZ-fusion channel and forward muon detection at high energy muon colliders to address the challenge of the Higgs coupling-width degeneracy. Our approach enables inclusive Higgs rate measurement to 0.75% at 10 TeV muon collider, breaking the coupling-width degeneracy. Results indicate the potential to refine Higgs coupling to subpercent levels and estimate its total width within (–0.41%, +2.1%). Key insights include the effectiveness of forward muon tagging in signal-background separation despite broad recoil mass distribution due to muon energy reconstruction and beam energy spread. The study emphasizes the significance of muon rapidity coverage up to |η⁡(μ)| < 6, enhancing measurement precision. Our findings highlight the unique capabilities of high energy lepton colliders for model-independent Higgs coupling determination and lay the groundwork for future advancements in muon collider technology and Higgs physics research.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Macroscopic approach to the radar echo scatter from high-energy particle cascades

To probe the cosmic particle flux at the highest energies, large volumes of dense material like ice have to be monitored. This can be achieved by exploiting the radio signal. In this work, we provide a macroscopic model to predict the radar echo signatures found when a radio signal is reflected from a cosmic-ray or neutrino-induced particle cascade propagating in a dense medium like ice. Its macroscopic nature allows for an energy independent run-time, taking less than 10 s for simulating a single scatter event. As a first application, we discuss basic signal properties and simulate the expected signal for the T-576 beam-test experiment at the Stanford Linear Accelerator Center. Finally, we find good signal strength agreement with the only observed radar echo from a high-energy particle cascade to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-resonant picosecond three-wave mixing in the gas phase

We report on the experimental observation of non-resonant, second-order optical sum-frequency generation (SFG) in five different atomic and molecular gases. The measured signal is attributed to a SFG process by characterizing its intensity scaling and its polarization behavior. We show that the electric quadrupole mechanism cannot explain the observed trends and suggest a mechanism based on symmetry breaking along the incident beam path arising from laser-induced species ground state number density gradients. Our results demonstrate that the SFG is about four orders of magnitude stronger than the third-harmonic generation (THG) and independent from any externally applied electric fields. In conclusion, these features make this method suitable for gas number density measurements at the picosecond time scale in reactive flows and plasmas.

LaCombe, Grayson↗

Megavolt bremsstrahlung measurements from linear induction accelerators demonstrate possible use as a FLASH radiotherapy source to reduce acute toxicity

Abstract Recent studies indicate better efficacy and healthy tissue sparing with high dose-rate FLASH radiotherapy (FLASH-RT) cancer treatment. This technique delivers a prompt high radiation dose rather than fractional doses over time. While some suggest thresholds of > 40 Gy s −1 with a maximal effect at > 100 Gy s −1 , accumulated evidence shows that instantaneous dose-rate and irradiation time are critical. Mechanisms are still debated, but toxicity is minimized while inducing apoptosis in malignant tissue. Delivery technologies to date show that a capability gap exists with clinic scale, broad area, deep penetrating, high dose rate systems. Based on these trends, if FLASH-RT is adopted, it may become a dominant approach except in the least technologically advanced countries. The linear induction accelerator (LIA) developed for high instantaneous and high average dose-rate, species independent charged particle acceleration, has yet to be considered for this application. We review the status of LIA technology, explore the physics of bremsstrahlung-converter-target interactions and our work on stabilizing the electron beam. While the gradient of the LIA is low, we present our preliminary work to improve the gradient by an order of magnitude, presenting a point design for a multibeam FLASH-RT system using a single accelerator for application to conformal FLASH-RT.

42 ENGINEERING↗

Comparison of Doppler back-scattering and charge exchange measurements of E × B plasma rotation in the DIII-D tokamak under varying torque conditions

Measurements of the E × B toroidal angular velocity, $\omega_{E \times B}\,=\,E_\mathrm{r}/RB_\theta$ ($E_\mathrm{r}$ is the radial electric field, B θ is the poloidal magnetic field), are made using the Doppler back-scattering (DBS) and charge-exchange recombination (CER) spectroscopy diagnostics. DBS uses the Doppler shift of wavenumber-resolved density fluctuations while CER uses the Doppler shift of impurity emission lines to independently measure plasma parameters for calculating the local radial electric field. DBS and CER profiles of $\omega_{E \times B}$ as a function of normalized toroidal flux (ρ) are compared at various levels of neutral beam applied torque on the plasma. Under standard neoclassical theory $\omega_{E\times B}$ is a flux surface quantity, making it appropriate to compare across diagnostics. DBS and CER generally show good agreement when comparing $\omega_{E \times B}$ profiles at different levels of neutral beam injection-applied torque. Furthermore, the DBS values have close to the same precision as CER values when averaged over a similar time-scale and effects, such as prompt-torque are considered. DBS is able to observe the rapid ($\lt$10 ms) modification of the $E_\mathrm{r}$ profile by the diagnostic neutral beam 'blips'. This modification is most pronounced when the blip applies a large relative change in torque on the plasma. Overall, these results could have implications on transport analysis and suggests using DBS and CER in conjunction to constrain values of the E × B-shear (sometimes called $\gamma_{E \times B}$).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗