Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Photoionization research on atomic beams. 2: The photoionization cross section of atomic oxygen

An experiment to determine the absolute value of the photo-ionization cross section of atomic oxygen is described. The atoms are produced in an electrical discharge in oxygen gas with 1% hydrogen added. In order to prevent recombination a crossed beam technique is employed. The ions formed are detected by a time-of-flight mass spectrometer. The concentration of oxygen atoms in the beam is 57%. The measured photoionization cross section of atomic oxygen is compared with theoretical data. The results show the participation of autoionization processes in ionization. The cross section at the autoionizing levels detected is considerably higher than the absorption due to the unperturbed continuum. Except for wavelengths where autoionization occurs, the measured ionization cross section is in fair agreement with theory. This holds up to 550 A whereas for shorter wavelengths the theoretical values are much higher.

Comes, F. J.↗

Optical and scratch resistant properties of diamondlike carbon films deposited with single and dual ion beams

Amorphous diamondlike carbon (DLC) films were deposited using both single and dual ion beam techniques utilizing filament and hollow cathode ion sources. Continuous DLC films up to 3000 A thick were deposited on fused quartz plates. Ion beam process parameters were varied in an effort to create hard, clear films. Total DLC film absorption over visible wavelengths was obtained using a Perkin-Elmer spectrophotometer. An ellipsometer, with an Ar-He laser (wavelength 6328 A) was used to determine index of refraction for the DLC films. Scratch resistance and frictional and adherence properties were determined for select films. Applications for these films range from military to the ophthalmic industries.

Kussmaul, Michael T.↗

Optical and Scratch Resistant Properties of Diamondlike Carbon Films Deposited with Single and Dual Ion Beams

Amorphous diamond-like carbon (DLC) films were deposited using both single and dual ion beam techniques utilizing filament and hollow cathode ion sources. Continuous DLC films up to 3000 A thick were deposited on fused quartz plates. Ion beam process parameters were varied in an effort to create hard, clear films. Total DLC film absorption over visible wavelengths was obtained using a Perkin-Elmer spectrophotometer. An ellipsometer, with an Ar-He laser (wavelength 6328 A) was used to determine index of refraction for the DLC films. Scratch resistance, frictional, and adherence properties were determined for select films. Applications for these films range from military to the ophthalmic industries.

Kussmaul, Michael T.↗

The KACST Heavy-Ion Electrostatic Storage Ring

A novel Electrostatic Storage Ring (ESR) for beams at energies up to 30keV/q is now being constructed at the National Centre for Mathematics and Physics (NCMP), King Abdul-Aziz City for Science and Technology (KACST). The ring is designed to be the core of a highly flexible experimental platform that will combine a large package of complementary beam techniques for atomic and molecular physics and related fields. The lattice design had to cover the different experimental techniques that the ring will be equipped with, such as e.g. Electron-Ion, Laser-Ion, Ion-Ion or Ion-Neutral beams, in both crossed and merged-beam configurations. The development of such an ESR is realized in a staged approach, in which a simple and early-run adaptation of the ring is built first, and then this basic version is upgraded to a higher symmetry of the ultimate version of the ring. Here, we report a general overview of this technical development with a focus on the layout of the first built stage of the ring.

43 PARTICLE ACCELERATORS↗

Molecular beams in chemistry.

The molecular-beam technique is a means for producing isolated atoms or molecules within a narrow range of speed and solid angle. The phenomena studied with molecular beams can be classified as single-particle interactions, many-particle interactions, and two particle-interactions. The results of scattering experiments fall into two categories including collisions that do not result in atomic rearrangements and collisions that do. Experimental methods are discussed, giving attention to low-energy beams, high-energy beams, and intermediate-energy beams. Examples are presented to illustrate the information that can be obtained from elastic, inelastic, and reactive scattering.

Jordan, J. E.↗

Researches on interactions of satellite-speed helium atoms with aluminum and quartz surfaces

Three major areas were experimentally studied: (1) energy transfer in collisions of satellite-speed (700 m/sec) helium atoms with a cleaned satellite-type aluminum surface was investigated using the molecular-beam technique. Spatial and energy distributions of reflected helium atoms were measured and analyzed, (2) The gross accommodation coefficient for a satellite-speed (7000 m/sec) helium beam entering a 2-inch-diameter aluminum spherical cavity was determined by measuring the exit velocity distribution of the leaving helium atoms using a metastable time-of-flight method. Results indicate that the 7000-m/sec satellite-speed helium atoms entering the cavity gain full accommodation with the room-temperature inner surface of the sphere through a large number of collisions before leaving the spherical cavity; and (3) the feasibility of producing a satellite-speed atomic hydrogen beam by arc-heating, for use in studies of interactions of satellite-surfaces with hydrogen atoms under laboratory conditions, was investigated. It was found that a stable arc-heated molecular hydrogen beam can be obtained using the arc-heater, and that a partially dissociated hydrogen beam can be produced. Photographs of laboratory equipment are shown.

Liu, S. M.↗

Dopant Activation and Defect Analysis of Ultra-Shallow Junctions Made by Gas Cluster Ion Beams

A long-standing problem in the fabrication of junctions by ion implantation is the enhanced diffusion caused by interstitial agglomeration and dissolution on annealing. Another side effect is residual damage that leads to junction leakage. The gas cluster ion beam technique (GCIB) offers a means of introducing dopant atoms without the creation of interstitials due to the low energy non-ballistic nature of the individual atoms and the localized thermal spike associated with the collision event between the large cluster and the silicon surface. We have employed cluster ion beams to infuse B into Si substrates to fabricate ultra-shallow junctions. Various annealing techniques were used to investigate GCIB B activation. We find that annealing at temperatures around 950 deg. C results in profiles that do not exhibit the extended tail characteristic of enhanced diffusion. This is in contrast to profiles in ion implanted samples, which inevitably result in enhanced diffusion. For laser and flash anneal, because the time scale of process is short, multiple anneal passes are needed in order to achieve low sheet resistance with little diffusion. We have shown that control of interfacial and surface smoothness is critical in improving junction characteristics.

36 MATERIALS SCIENCE↗

A practical method of modeling a treatment couch using cone-beam computed tomography for intensity-modulated radiation therapy and RapidArc treatment delivery

The effect of a treatment couch on dose perturbation is not always fully considered in intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). In the course of inverse planning radiotherapy techniques, beam parameter optimization may change in the absence of the couch, causing errors in the calculated dose distributions. Although modern treatment planning systems (TPS) include data for the treatment couch components, they are not manufactured identically. Thus, variations in their Hounsfield unit (HU) values may exist. Moreover, a radiotherapy facility may wish to have a third-party custom tabletop installed that is not included by the TPS vendor. This study demonstrates a practical and simple method of acquiring reliable computed tomography (CT) data for the treatment couch and shows how the absorbed dose calculated with the modeled treatment couch can differ from that with the default treatment couch found in the TPS. We also experimentally verified that neglecting to incorporate the treatment couch completely in the treatment planning process might result in dose differences of up to 9.5% and 7.3% for 4-MV and 10-MV photon beams, respectively. Furthermore, 20 RapidArc and IMRT cases were used to quantify the change in calculated dose distributions caused by using either the default or modeled couch. From 2-dimensional (2D) ionization chamber array measurements, we observed large dose distribution differences between the measurements and calculations when the couch was omitted that varied according to the planning technique and anatomic site. Thus, incorporating the treatment couch in the dose calculation phase of treatment planning significantly decreases dose calculation errors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ion plating for the future

The ion plating techniques are classified relative to the instrumental set up, evaporation media and mode of transport. Distinction is drawn between the low vacuum (plasma) and high vacuum (ion beam) techniques. Ion plating technology is discussed at the fundamental and industrial level. At the fundamental level, the capabilities and limitations of the plasma (evaporant flux) and film characteristics are evaluated. On the industrial level, the performance and potential uses of ion plated films are discussed.

Spalvins, T.↗

Ion plating for the future

The ion plating techniques are classified relative to the instrumental set up, evaporation media, and mode of transport. A distinction is drawn between the low vacuum (plasma) and high vacuum (ion beam) techniques. Ion plating technology is discussed at the fundamental and industrial level. At the fundamental level, the capabilities and limitations of the plasma (evaporant flux) and film characteristics are evaluated. And on the industrial level, the performance and potential uses of ion plated films are discussed.

Spalvins, T.↗

Oak Ridge National Laboratory Official TM Cover: Development and Qualification of Tungsten Reference Materials for LA-ICP-MS

Reference materials have been developed to provide areal density measurements of tungsten that is deposited on graphite when using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Several reference materials of varying areal densities have been produced using a magnetron sputtering, thin film deposition technique. With multiple reference materials that have varying areal densities, a calibration curve has been developed for translating the detector response of an ICP-MS into a quantitative measurement. These results provide the opportunity to make calibrated comparisons across graphite samples that were exposed to tungsten transport experiments for nuclear fusion research. In addition, these methods may be applied to provide individual areal density measurements for the five unique isotopes of tungsten. It is found that areal density measurements via LA-ICP-MS agree with characterization for the same samples when using the more traditional Rutherford backscattering ion beam technique. Qualification of these reference materials was completed using ion beam laboratories at the University of Tennessee, Knoxville and Massachusetts Institute of Technology, and Sandia National Laboratory.

36 MATERIALS SCIENCE↗

A novel approach to the identification and quantitative elemental analysis of amyloid deposits-Insights into the pathology of Alzheimer's disease

There is considerable interest in the role of metals such as iron, copper, and zinc in amyloid plaque formation in Alzheimer's disease. However to convincingly establish their presence in plaques in vivo, a sensitive technique is required that is both quantitatively accurate and avoids isolation of plaques or staining/fixing brain tissue, since these processes introduce contaminants and redistribute elements within the tissue. Combining the three ion beam techniques of scanning transmission ion microscopy, Rutherford back scattering spectrometry and particle induced X-ray emission in conjunction with a high energy (MeV) proton microprobe we have imaged plaques in freeze-dried unstained brain sections from CRND-8 mice, and simultaneously quantified iron, copper, and zinc. Our results show increased metal concentrations within the amyloid plaques compared with the surrounding tissue: iron (85 ppm compared with 42 ppm), copper (16 ppm compared to 6 ppm), and zinc (87 ppm compared to 34 ppm).

60 APPLIED LIFE SCIENCES↗

Ion-beam nitriding of steels

The application of the ion beam technique to the nitriding of steels is described. It is indicated that the technique can be successfully applied to nitriding. Some of the structural changes obtained by this technique are similar to those obtained by ion nitriding. The main difference is the absence of the iron nitride diffraction lines. It is found that the dependence of the resultant microhardness on beam voltage for super nitralloy is different from that of 304 stainless steel.

Salik, J.↗

Ion-beam nitriding of steels

The application of the ion beam technique to the nitriding of steels is described. It is indicated that the technique can be successfully applied to nitriding. Some of the structural changes obtained by this technique are similar to those obtained by ion nitriding. The main difference is the absence of the iron nitride diffraction lines. It is found that the dependence of the resultant microhardness on beam voltage for super nitralloy is different from that of 304 stainless steel.

Salik, J.↗

Modulating Oxide‐Based Quantum Materials by Ion Implantation

Ion implantation has emerged as a powerful tool for manipulating and investigating oxide quantum materials, where strong electron correlations give rise to exotic phases and functionalities. This Review examines how controlled ion bombardment enables targeted modulation of structural, electronic, and magnetic properties in complex oxides. Recent advances in ion beam techniques is analyzed that provide unprecedented control over defect profiles, from point defects to extended damage cascades. In application, ion irradiation has demonstrated the ability to tune quantum phenomena including metal‐insulator transitions, magnetism, and superconductivity through selective doping, defect creation, and lattice strain. The ability to write quantum states with nanoscale precision using focused ion beams is opening new paths for quantum device fabrication. Challenges in understanding radiation damage mechanisms in strongly correlated systems is discussed, and identify opportunities for designing quantum functionality through defect‐engineering approaches. The technique's demonstrated capability to write quantum states with nanoscale precision, combined with its compatibility with existing semiconductor processing infrastructure, suggests a clear pathway for translating fundamental discoveries in quantum materials into practical technological applications.

defect engineering↗

Quantitative transmission electron microscopy analysis of multi-variant grains in present L1{sub 0}-FePt based heat assisted magnetic recording media

We present a study on atomic ordering within individual grains in granular L1{sub 0}-FePt thin films using transmission electron microscopy techniques. The film, used as a medium for heat assisted magnetic recording, consists of a single layer of FePt grains separated by non-magnetic grain boundaries and is grown on an MgO underlayer. Using convergent-beam techniques, diffraction patterns of individual grains are obtained for a large number of crystallites. The study found that although the majority of grains are ordered in the perpendicular direction, more than 15% of them are multi-variant, or of in-plane c-axis orientation, or disordered fcc. It was also found that these multi-variant and in-plane grains have always grown across MgO grain boundaries separating two or more MgO grains of the underlayer. The in-plane ordered portion within a multi-variant L1{sub 0}-FePt grain always lacks atomic coherence with the MgO directly underneath it, whereas, the perpendicularly ordered portion is always coherent with the underlying MgO grain. Since the existence of multi-variant and in-plane ordered grains are severely detrimental to high density data storage capability, the understanding of their formation mechanism obtained here should make a significant impact on the future development of hard disk drive technology.

36 MATERIALS SCIENCE↗