Search NASA⌕ Search

SEARCH · Search NASA

Results for “beamline optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Optical design and efficiency measurement of an extreme ultraviolet high-resolution spectrometer for unresolved transition array research

Understanding the structures of the unresolved transition array (UTA) observed in extreme ultraviolet (EUV) spectra from many-electron atoms is crucial for various applications, including fusion science and nanolithography. Here, to measure the fine structure of the UTA from tungsten and tin at around 5 and 13.5 nm at the Tokyo electron beam ion trap, we developed a high-resolution EUV spectrometer. The designed spectrometer achieves a resolving power of λ/dλ > 5000 at 5 and 13.5 nm. The fabricated large-area grating was experimentally examined at beamline BL5B of the UVSOR synchrotron facility to evaluate the diffraction efficiencies and their variation across the ruled area. The measured diffraction efficiencies are 0.65% ± 0.07% at 5 nm (second order) and 7.9% ± 0.2% at 13.5 nm (first order). The variation in the diffraction efficiency across the ruled area is 2.2%, 13.6%, and 10.0% in zeroth, first, and second order diffractions, respectively. The discrepancies in diffraction efficiencies between the experiments and the calculations were 5.2%, 29%, and 35% for the zeroth, first, and second diffraction orders, respectively.

47 OTHER INSTRUMENTATION↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature Mapping of Stacked Silicon Dies from X-Ray-Diffraction Intensities

Increasing power densities in integrated circuits have led to an increased prevalence of thermal hotspots in integrated circuits. Tracking these thermal hotspots is imperative to prevent circuit failures. In three- dimensional (3D) integrated circuits, conventional surface techniques like infrared thermometry are unable to measure the 3D temperature distribution, and optical and magnetic resonance techniques are difficult to apply due to the presence of metals and large current densities. X-rays offer a high penetration depth and can be used to probe 3D structures. We report a method utilizing the temperature dependence of x-ray-diffraction intensity via the Debye-Waller factor to simultaneously map the temperature of individual silicon dies in a stack. Here, utilizing beamline 1-ID-E at the Advanced Photon Source (Argonne), we demonstrate, for each individual silicon die, a temperature resolution of 3 K, a spatial resolution of 100 × 400 μm 2 , and a temporal resolution of 20 s. Utilizing a sufficiently high-intensity laboratory source, e.g., from a liquid-anode source, this method can be scaled down to laboratories for noninvasive temperature mapping of 3D integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of readout electronics for the CMS ME0 muon detector

The Large Hadron Collider (LHC) in the High Luminosity (HL-LHC) era will be upgraded to deliver instantaneous luminosities up to 5 X 10 34 cm -2 s -1 , five times more than the original design value. In order to maintain performance of the Compact Muon Solenoid (CMS) Experiment under these conditions, ME0 is one of the new muon detectors to be added, along with GE1/1, GE2/1, RE3/1 and RE4/1. ME0 uses the triple Gas Electron Multiplier (GEM) technology and is designed to cover the far-forward region of 2.0 < |η| < 2.8. Further, the readout electronics for ME0 must be designed to deal with high data rates and be sufficiently radiation hard to operate very close to the beamline. The design and development status of the readout electronics for ME0 are presented, along with recent results from integration tests performed using the latest electronics prototypes with GEM chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The chemRIXS Instrument for Solution-Phase Resonant Inelastic X-ray Scattering at the Linac Coherent Light Source

The chemRIXS instrument at the Linac Coherent Light Source (LCLS) offers new opportunities for studying solution-phase systems with time-resolved soft X-ray spectroscopic methods such as resonant inelastic X-ray scattering (RIXS) using the recently commissioned high-repetition-rate LCLS-II X-ray free electron laser. The orders-of-magnitude X-ray flux improvement provided by the superconducting accelerator, combined with corresponding advances in the optical laser system and the liquid jet recirculation system, enables studies on dilute systems with high signal-to-noise compared to what was possible with the LCLS-I copper accelerator. These capabilities open up time-resolved X-ray absorption spectroscopy and RIXS to entirely new classes of samples, as well as enabling the development of new soft X-ray spectroscopic methods on liquid samples. An overview of the beamline components and the first LCLS-II commissioning results are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compression–tension cell with sample manipulator for in situ X‐ray nanotomography experiments

In situ X-ray nanotomography experiments where tensile or compressive force is applied on the sample require specialized equipment. A compression-tension device with fluid flow-through capability has been designed for X-ray nanotomography beamlines. The compression-tension cell is equipped with a triaxial stage for sample alignment and a high sensitivity loadcell for measurement of applied force. To handle the <100 µm samples used for X-ray nanotomography imaging and for loading samples on the compression-tension cell a sample manipulator has been built. The sample manipulator is capable of selecting a single <100 µm particle for nanotomography scanning while viewing multiple samples under an optical microscope. To test the functionality of these two devices an initial compression experiment involving two glass beads was performed. To demonstrate instrument stability two spherical glass beads were compressed from a no load condition until one of the beads fractured. Nanotomography data were collected at each step of increasing compressive force. The experimentally observed contact area of the spherical glass beads was compared with the theoretical estimate using the Hertz analysis. To demonstrate the fluid flow capability, two calcite grains were compressed against each other under a calcite saturated solution. Surface topological changes were observed for the stressed grain contact area.

X-ray tomography↗

Design update on the transition beamline for the CEBAF Energy Upgrade

For Jefferson Lab’s 22GeV upgrade, two new permanent-magnet Fixed-Field Alternating Gradient (FFA) arcs will be integrated to serve the accelerator’s six highest-energy recirculation passes. Connecting these FFA arcs to the existing linear accelerator (linac) requires a carefully engineered transition section. The current design has two parts where the first part adiabatically matches the beam dispersion and orbit trajectories, while the second part aligns the Twiss parameters (alpha and beta functions) with those at the linac entrance. Given the tight spatial constraints and multiple matching requirements, a genetic algorithm is being explored to optimize the beam optics matching. This paper presents the current progress in developing and optimizing this transition.

Accelerator Physics↗

Laser heating system at the Extreme Conditions Beamline, P02.2, $\mathrm{PETRA III}$

A laser heating system for samples confined in diamond anvil cells paired with in situ X-ray diffraction measurements at the Extreme Conditions Beamline of PETRA III is presented. The system features two independent laser configurations (on-axis and off-axis of the X-ray path) allowing for a broad range of experiments using different designs of diamond anvil cells. The power of the continuous laser source can be modulated for use in various pulsed laser heating or flash heating applications. An example of such an application is illustrated here on the melting curve of iron at megabar pressures. The optical path of the spectroradiometry measurements is simulated with ray-tracing methods in order to assess the level of present aberrations in the system and the results are compared with other systems, that are using simpler lens optics. Based on the ray-tracing the choice of the first achromatic lens and other aspects for accurate temperature measurements are evaluated.

47 OTHER INSTRUMENTATION↗

A WISER way for simulating the performance of gratings

Soft X-ray monochromators for synchrotron radiation sources have been continuously developed over the years, improving energy resolution and stability. Great effort has been made in improving the surface quality of the optics involved, reaching values permitting diffraction-limited images. Still, one problem has not been solved, nor fully understood, yet: groove placing errors. Nowadays, these are one of the major factors responsible for resolving the power reduction of diffraction-gratings-based X-ray monochromators. Despite decades of use of gratings, there is not yet a universally established method for predicting and simulating the effect of groove placing errors on monochromator performance. This is especially important in the new scenario of high-coherent X-ray sources, i.e. diffraction-limited storage rings and free-electron lasers. To address this problem, in this article an approach based on WISER (Wavefront propagatIon Simulation codE libRary) is presented. WISER is a physical optics simulation package, also available in the user-friendly Orange Synchrotron Radiation Suite – OASYS. Even though it was originally conceived to assess the focusing performance of X-ray mirrors in the presence of height defects, it perfectly simulates the performance of a periodic (or quasi-periodic) structure like a diffraction grating. In this article, the way to use WISER and its application to a specific case, e.g. the design of a monochromator for the upgrade of a beamline at the Advanced Light Source, are shown. A simple rule for estimating how well the grooves are placed on a grating, based on calculation of the Strehl ratio, is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORBIT CORRECTION STUDIES ON THE ELECTRON TRANSPORT LINE FROM RCS TO ESR

A dedicated electron transfer line from Rapid Cycling Synchrotron (RCS) to Electron Storage Ring (ESR), referred to as the RTE line has been designed for the Electron-Ion Collider (EIC). The beamline follows a straight-line geometry, with a length of 133 m, and is consists with two matching sections and a FODO section for beam diagnostics. Imperfections with magnet alignments introduce orbit distortions, making orbit correction scheme a critical component in the design. To facilitate orbit correction, each quadrupole magnet is equipped with a pair of beam position monitors (BPMs) and kickers. The Singular Value Decomposition (SVD) algorithm is used for orbit correction and tolerance studies. This paper presents the ongoing progress in the optics design and error correction scheme of the RTE line.

Neththikumara, I. [Thomas Jefferson National Accel↗

Correcting aberrations of a transverse-field neutron resonance spin echo instrument

Neutron resonance spin echo (NRSE) technique has the potential to increase the Fourier time and energy resolution in neutron scattering by using radio frequency (rf) neutron spin-flippers. However, aberrations arising from variations in the neutron path length between the rf flippers reduce the polarization. Here, we develop and test a transverse static-field magnet, a series of which are placed between the rf flippers, to correct for these aberrations. The prototype correction magnet was both simulated in an NRSE beamline using McStas, a Monte Carlo neutron ray-tracing software package, and measured using neutrons. The results from the prototype demonstrate that this static-field design corrects for transverse-field NRSE aberrations.

47 OTHER INSTRUMENTATION↗

General guide concepts for compact, high-brilliance neutron moderators

The trend in neutron sciences is toward integrating compact, high-brightness moderators into new or upgraded facilities. Transporting neutrons from the source to the sample position with a phase-space distribution tailored to specific requirements is crucial to leverage high source brilliance. Here we have investigated four guide concepts using Monte Carlo ray tracing simulations: Montel beamline with nested Kirkpatrick–Baez mirrors, curved-tapered beamline with a bender and straight sections, straight-elliptical beamline, and curved-elliptical beamline. The straight-elliptical (curved-elliptical) beamline features two half-ellipse guides connected by a straight (non-straight) guide section. The neutron transport efficiency and phase space homogeneity have been quantitatively compared. Our results show that the straight-elliptical beamline performs best because of few neutron bounces on the guide surface with small reflection angles, minimizing flux loss. The Montel beamline provides the best spatial confinement of neutrons within the desired region; however, there is a high thermal-neutron loss due to large reflection angles. The curved-tapered beamline suffers from significant flux loss due to high bounces, and it shows a non-uniform angular distribution related to broad ranges of bounces and reflection angles. The non-straight guide section of the curved-elliptical beamline increases the phase space inhomogeneity, leading to a spatially non-uniform beam profile. The results apply to general neutron instruments that require transporting thermal and cold neutrons from a compact, high-brilliance moderator to the sample location with a moderate phase-space volume.

47 OTHER INSTRUMENTATION↗

Diffuse X-ray scattering from polished silicon: application of the distorted wave Born approximation

Measured diffuse X-ray scattering data for a `smooth' as well as for a `rough' silicon sample were fit to theoretical expressions within the distorted wave Born approximation (DWBA). Data for the power spectral density (PSD) for both samples were also obtained by means of atomic force microscopy and optical interferometry. The Fourier transforms of trial correlation functions were fit to the PSD data and then applied to the DWBA formalism. The net correlation functions needed to fit the PSD data for each sample comprised the sum of two terms with different cutoff lengths and different self-affine fractal exponents. At zero distance these correlation functions added up to yield net values of σ 2 = (2) 2 and (71) 2 Å 2 for the smooth and rough samples, respectively. X-ray scattering data were obtained at beamline 1-BM of the Advanced Photon Source. Data and fits at values of q z = 0.05 and 0.10 Å −1 for the smooth sample are reported. Good fits for the smooth sample were obtained at both q z values simultaneously, that is, identical fitting parameters were applied at both values of q z . The smooth sample also exhibited weak Yoneda wings and a clear distinction between the strong specular scattering and the weak diffuse scattering. Data for the rough sample were qualitatively different and exhibited very weak scattering at the specular condition in contrast to extremely large Yoneda wings. Fits for the rough sample are reported for q z = 0.04, 0.05, and 0.06 Å −1 . Although the large Yoneda wings could be fit quite well in both position and amplitude, scattering near the specular condition could not be equally well fit by applying the same fitting parameters at all values of q z . Albeit imperfect, best-fitting results at the specular condition were obtained by invoking only diffuse scattering, that is, without including a separate theoretical expression for specular scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulations Supporting the Development of Northstar's Indirect Beam Parameters Monitoring System

NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons impinged on the molybdenum target produce bremsstrahlung X-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (and heat deposition in the target), which creates challenging requirements for the cooling of the target. The critical part of the target is the target window. It separates the high-pressure helium cooled target from the vacuum beamline and the subject of structural and thermal stress. The temperature of the target window is proportional to the energy density deposited by the beam, so it is critical to maintain the desired beam profile on the target window. The feasibility of indirectly monitoring the maximum energy density of the beam on the beam window through beam losses at the main collimator (Collimator) before the production target was verified. A model of the NorthStar beam transport line was constructed for this purpose using MAD-X and Tao/Bmad codes. Beam optics were computed for the standard operational scenario, followed by an investigation involving approximately 400 cases with parameter variations in the last tuning quadrupoles. This was done to assess the correlation between losses in the collimator and the peak energy density on the target. We developed a model to explore the potential application of Optical transition radiation (OTR) for controlling beam parameters in the NorthStar beam delivery system. This model was based on a generic formula derived from the fundamental solution of the inhomogeneous wave equation of the vector potential, and allowed us to consider various surfaces, even those with irregular or random features, using numerical integration. We applied the model to OTR generated by relativistic electrons impacting an Inconel® 718 beam window. We examined cases with different levels of the window’s surface roughness, ranging from 0.5 to 3.0 microns of root square mean (RMS) deviation. The results of the OTR simulations provided distributions of OTR photons that can be used to study the limitations of optical systems for controlling beam parameters.

43 PARTICLE ACCELERATORS↗

Search for Fluid Inclusions in a Carbonaceous Chondrite Using a New X-Ray Micro-Tomography Technique Combined with FIB Sampling

Early solar system aqueous fluids are preserved in some H chondrites as aqueous fluid inclusions in halite (e.g., [1]). Although potential fluid inclusions are also expected in carbonaceous chondrites [2], they have not been surely confirmed. In order to search for these fluid inclusions, we have developped a new X-ray micro-tomography technique combined with FIB sampling and applied this techniqu to a carbanaceous chondrite. Experimental: A polished thin section of Sutter's Mill meteorite (CM) was observed with an optical microscope and FE-SEM (JEOL 7001F) for chosing mineral grains of carbonates (mainly calcite) and sulfides (FeS and ZnS) 20-50 microns in typical size, which may have aqueous fluid inclusions. Then, a "house" similar to a cube with a roof (20-30 microns in size) is sampled from the mineral grain by using FIB (FEI Quanta 200 3DS). Then, the house was atached to a thin W-needle by FIB and imaged by a SR-based imaging microtomography system with a Fresnel zone plate at beamline BL47XU, SPring-8, Japan. One sample was imaged at two X-ray energies, 7 and 8 keV, to identify mineral phases (dual-enegy microtomography: [3]). The size of voxel (pixel in 3D) was 50-80 nm, which gave the effective spatial resolution of approx. 200 nm. A terrestrial quartz sample with an aqueous fluid inclusion with a bubble was also examined as a test sample by the same method. Results and discussion: A fluid inclusion of 5-8 microns in quartz was clearly identified in a CT image. A bubble of approx. 4 microns was also identified as refraction contrast although the X-ray absorption difference between fluid and bubble is small. Volumes of the fluid and bubble were obtained from the 3D CT images. Fourteen grains of calcite, two grains of iron sulfide and one grain of (Zn,Fe)S were examined. Ten calcite, one iron sulfide and one (Zn,Fe)S grains have inclusions >1 micron in size (the maximum: approx. 5 microns). The shapes are spherical or irregular. Tiny inclusions (<1 micron) are also present in all the grains examined. These results show that mineral grains have more inclusions than expected from 2D observations. The X-ray absorption of the inclusions shows that they are not solid inclusions. No bubbles were observed inside, indicating that we cannot determine whether they are really aqueous fluids or merely voids. One calcite grain has an inclusion approx. 2 microns in size, which seems to have a bubble and a tiny solid daughter crystal inside (three-phase inclusion). As we know the exact 3D position of the inclusion, we will anlyze the inclusion by SIMS after freezing the sample as has been done for a halite sample [3]. The present technique is useful for finding small inclusions not only in carbonaceous chondrites but also for terrestrial materials.

Tsuchiyama, A.↗

Robotic pendant drop: containerless liquid for μs-resolved, AI-executable XPCS

Abstract The dynamics and structure of mixed phases in a complex fluid can significantly impact its material properties, such as viscoelasticity. Small-angle X-ray Photon Correlation Spectroscopy (SA-XPCS) can probe the spontaneous spatial fluctuations of the mixed phases under various in situ environments over wide spatiotemporal ranges (10 −6 –10 3 s /10 −10 –10 −6 m). Tailored material design, however, requires searching through a massive number of sample compositions and experimental parameters, which is beyond the bandwidth of the current coherent X-ray beamline. Using 3.7-μs-resolved XPCS synchronized with the clock frequency at the Advanced Photon Source, we demonstrated the consistency between the Brownian dynamics of ~100 nm diameter colloidal silica nanoparticles measured from an enclosed pendant drop and a sealed capillary. The electronic pipette can also be mounted on a robotic arm to access different stock solutions and create complex fluids with highly-repeatable and precisely controlled composition profiles. This closed-loop, AI-executable protocol is applicable to light scattering techniques regardless of the light wavelength and optical coherence, and is a first step towards high-throughput, autonomous material discovery.

36 MATERIALS SCIENCE↗