Search NASA⌕ Search

SEARCH · Search NASA

Results for “building management system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗

NREL's Advanced Distribution Management System (ADMS) Test Bed

Transform utility electric distribution management systems to enable the integration and management of all assets and functions across the utility enterprise regardless of vendor or technology. Four program areas: Platform: Develop an open-source platform; evaluate advanced applications. Test bed: Build a vendor-neutral test bed to evaluate existing and future advanced distribution management system (ADMS) functionalities in a realistic setting. Applications: Develop an initial suite of ADMS applications. Advanced control: Develop new integrated optimization and control solutions.

ADMS test bed↗

Computational Tools and Workflows for Quantitative Risk Assessment and Decision Support for Geologic Carbon Storage Sites: Progress and Insights from the U.S. DOE’s National Risk Assessment Partnership

The 2005 Intergovernmental Panel on Climate Change (IPCC) Special Report on CCS raised the profile of CO2 capture and storage (CCS) as an important technology for reducing greenhouse gas (GHG) emissions. CCS is now recognized as a key component of most climate change mitigation scenarios. Since publication of that report the international research, development, and deployment (RD&D) community has advanced key technical aspects, clarified regulatory requirements, explored value chain and infrastructure solutions, and developed incentive paradigms to enable and promote large-scale deployment of CCS. These efforts have included research to better characterize geologic storage resources, to improve injection performance and storage efficiency, to assess and manage subsurface environmental risks, and to advance monitoring technologies to assure system conformance. These efforts have helped to build confidence in the viability of geologic carbon storage (GCS), but stakeholder concerns about long-term risks and liability associated with GCS remain a hurdle to broad acceptance and large-scale deployment of CCS. Since 2010, the U.S. DOE’s National Risk Assessment Partnership (NRAP) – a research collaboration between five contributing national laboratories – has worked to establish and demonstrate methods and tools to quantify and manage the subsurface environmental risks associated with GCS, amidst uncertainty. This work supports the Office of Fossil Energy and Carbon Management Carbon Transport and Storage Program’s goal of advancing safe and secure commercial-scale GCS deployment. To address the technical challenge of simulating the physical response of the GCS site to large-scale CO2 injection, NRAP has adopted an approach that relies on coupling computationally efficient reduced-order and/or data-driven proxy models of important system components (i.e., storage reservoir, sealing caprock, leakage pathways, intermediate formations, overlying groundwater aquifers, and the atmosphere) in integrated assessment framework. That integrated model of the physical system is complemented with fit-for purpose functionality to support site characterization and risk-related decisions. The recently released NRAP Phase II toolset includes the Open-Source Integrated Assessment Model (NRAP-Open-IAM) for evaluation of trends in leakage risk and potential impact, tools to support monitoring design optimization (Designs for Risk Evaluation and Management – DREAM v3.0 and Passive Seismic Monitoring Tool - PSMT), and tools for state of stress evaluation (State-of-Stress Analysis Tool - SOSAT) and forecasting induced seismicity risk. The NRAP team has also released a pair of reports describing conceptual workflows to incorporate physics-based, quantitative risk assessment into many of the design, planning, operation, and closure decisions for GCS projects. An online catalogue highlights published studies where these tools and methods are demonstrated. In this presentation, the utility of these products to assess risks and address key stakeholder questions will be highlighted through examples, and related insights about the safety and security of geologic carbon storage in qualified storage sites will be discussed. The prospect of rapid, large-scale deployment of GCS technology to aggressively reduce anthropogenic CO2 emissions requires careful consideration of interference between multiple commercial-scale storage projects within a basin. Going forward, NRAP is expanding and adapting site-scale risk quantification tools and methods to enable assessment of risks and inform management decisions for basin-scale deployment. Increasingly, this work will leverage next-generation approaches for surrogate modelling, fast prediction, and advanced visualization enabled by machine learning and artificial intelligence to promote virtual learning, scenario evaluation, and augment risk-based decision making.

quantitative risk assessment, geologic carbon stor↗

Building Demand Flexibility: Grid Service Value of Future Market Entrants

The building sector is an important source of demand-side flexibility that is crucial for renewable energy integration in the future power systems. The grid service value of building flexibility, especially that which provides load shifting, has not been analyzed for the United States. We use a technology-agnostic approach based on detailed grid expansion and production cost modeling results to evaluate the capacity, energy, and ancillary service values of a marginal kilowatt-hour (kWh) of daily, shiftable building flexibility as a presumed market entrant in the 2030 U.S. power systems. We find the monthly mean of building flexibility has a range of 0-38 cents/kWh-day, depending on the original usage hour, month, region, building flexibility parameters, and grid scenario. The daily value consists of the highest-value hour each day across all the scenarios has a range of 0-620 cents/kWh-day. The results are provided in an open database for users to obtain the values of specific technologies based on what services can be provided, when, and in what quantities.

30 DIRECT ENERGY CONVERSION↗

Recycling Wind Energy Systems in the United States Part 1: Providing a Baseline for America's Wind Energy Recycling Infrastructure for Wind Turbines and Systems

The U.S. investments in building this new wind energy capacity will not only mobilize millions of tons of raw and processed materials in existing supply chains, some of which are critical materials, but also create new types and large volumes of end-of-life (EOL) waste streams. Building efficient, cost-effective, and environmentally responsible EOL management infrastructure of wind energy system components is pivotal in diverting upcoming volumes of waste stream from landfills, recovery of critical materials and reducing life cycle emissions from production of primary commodity materials . The primary goal of this report is to organize and communicate findings from this assessment on how alternate materials, designs and manufacturing processes could enable more efficient, cost-effective, and environmentally responsible disassembly and resource recovery from wind energy technologies. The findings of this assessment could inform prioritization of RD&D investment spending to meet Energy Act of 2020 directions. This assessment focused on key RD&D recommendations for three main temporal phases: Short-term (2023-2026), medium-term (2026 through 2035) and long-term (beyond 2035).

17 WIND ENERGY↗

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maximum-impact Adversary Design for Network-based Control System: A Case Study on Grid-interactive Efficient Buildings

The Internet of Things (IoT) technology has dramatically improved the efficiency of today's building operation and management. By connecting controllable devices into a communication network, control signals can be easily passed to the devices, and operating status can be acquired from measurable ends with minimal effort. However, this all-connected configuration could also expose the network-based control system (NBCS) to malicious actions, such as cyberattacks. One of the common NBCSs is the building automation system. With the promotion of grid-interactive efficient buildings (GEBs), there has been increasing attention on securing the buildings from the network perspective. This research proposes a maximum-impact adversary design framework so that the adversary can provide the most adversarial impact on the controlled system while remaining stealthy. The proposed framework is numerically demonstrated on a network-based building energy and control system. The building energy system is built in a Modelica-based simulation environment and controlled by the state-of-the-art ASHRAE Guideline 36 control sequences. The control commands at the supervisory level, generated from the Guideline 36 controller, are assumed to be sent to local devices through communication networks using the BACnet protocol. Simulation results show that the proposed maximum-impact adversary on such a system can stealthily affect the building system's performance to its maximum extent. It is anticipated that results can be used by researchers and practitioners in the building automation industry to design efficient and robust cyber-attack detection algorithms, especially for stealthy attacks.

Chu, Mengyuan↗

Vectorization of CMSSW offline software

The CMS experiment has been utilizing vectorization, or SIMD, in parts of its data processing applications for over a decade. On x86 platforms the vectorization level is still SSE3. In the past attempts to use wider vector instruction sets such as AVX or AVX-512 have, in practice, not resulted in improvements in the overall event processing throughput, because the CPUs scale down their frequency when processing AVX instructions. In addition, a notable part of the global pool of CMS’ resources has been old systems either not supporting AVX, or where the CPU frequency downscaling impacts all cores of the CPU. CMS has nevertheless continued to vectorize more of its application code, and in this work we review profiling methods we have found effective to find out pieces of code that would benefit from vectorization, and techniques to transform those codes such that the GCC compiler is able to auto-vectorize those codes. The build system used for CMSSW, Scram, has also been enha nced to be able to build code for multiple CPU microarchitectures such that the shared libraries of desired microarchitecture level can be loaded based on the CPU of the system. This multi-microarchitecture setup is invisible to the workflow management system, which makes its deployment straightforward. We describe in detail how this multi-microarchitecture build is set up, and measure the impact of using wider vector units than SSE3 on the event processing throughput of CMS applications such as simulation and reconstruction on recent x86 CPUs.

Gartung, Patrick↗

Near isothermal compressed air energy storage system in residential and commercial buildings: Techno-economic analysis

Electrical energy storage systems offer a wide range of options to efficiently manage our power supply infrastructure. Energy and environmental security via renewable resources and energy storage devices will also play a critical role in addressing the supply-demand challenges. A novel energy efficient storage system based on near isothermal compressed air energy storage concept, named as Ground-Level Integrated Diverse Energy Storage (GLIDES) is analyzed for integration with residential and commercial buildings. Additionally, the influence of different configurational aspects on key performance and cost attributes is presented in this study. GLIDES modules in the range of 0.5 kWh–15 kWh configurations were considered for residential buildings whereas 25 kW h–500 kW h modules were considered for commercial buildings. Detailed cost and performance analysis of the GLIDES module proved them to be an effective resource in lowering the peak energy demand and corresponding utility bills.

25 ENERGY STORAGE↗

Safe and Private Forward-trading Platform for Transactive Microgrids

Power grids are evolving at an unprecedented pace due to the rapid growth of distributed energy resources (DER) in communities. These resources are very different from traditional power sources, as they are located closer to loads and thus can significantly reduce transmission losses and carbon emissions. However, their intermittent and variable nature often results in spikes in the overall demand on distribution system operators (DSO). To manage these challenges, there has been a surge of interest in building decentralized control schemes, where a pool of DERs combined with energy storage devices can exchange energy locally to smooth fluctuations in net demand. Building a decentralized market for transactive microgrids is challenging, because even though a decentralized system provides resilience, it also must satisfy requirements such as privacy, efficiency, safety, and security, which are often in conflict with each other. As such, existing implementations of decentralized markets often focus on resilience and safety but compromise on privacy. In this article, we describe our platform, called TRANSAX, which enables participants to trade in an energy futures market, which improves efficiency by finding feasible matches for energy trades, enabling DSOs to plan their energy needs better. TRANSAX provides privacy to participants by anonymizing their trading activity using a distributed mixing service, while also enforcing constraints that limit trading activity based on safety requirements, such as keeping planned energy flow below line capacity. We show that TRANSAX can satisfy the seemingly conflicting requirements of efficiency, safety, and privacy. We also provide an analysis of how much trading efficiency is lost. Trading efficiency is improved through the problem formulation, which accounts for temporal flexibility, and system efficiency is improved using a hybrid-solver architecture. Lastly, we describe a testbed to run experiments and demonstrate its performance using simulation results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data-Driven State of Health Estimation for Second-Life Batteries Using Interpolated Synthetic Data and Feature Selection

Accurate estimation of the State of Health (SOH) for second-life batteries (SLBs) is crucial given their increasing use in energy storage applications. Precise SOH prediction is essential for safe operation and robust battery management systems. A major challenge is the limited availability of datasets for building reliable degradation models. To address this, synthetic data generation through linear interpolation is performed to extend the available data, making it more representative of real-world battery operating conditions. By analyzing feature correlation with SOH, the most relevant features are selected for the model. The proposed approach employs a convolutional neural network (CNN) model trained on this interpolated, feature-selected dataset, using time series data of voltage, temperature, and current over a cycle. By focusing on highly correlated features, the model achieves over 95% accuracy, with mean absolute error and root mean squared error up to 2.27% and 2.64%, respectively, in SOH estimation for two battery datasets tested. These results highlight the potential of combining synthetic data generation and feature selection to enhance SOH predictions, showcasing the superior performance of the proposed CNN model for both new batteries and SLBs.

feature selection↗

Thermo-hydro-mechanical analysis of subsurface ice-based thermal energy storage

Ice-based thermal energy storage systems are widely utilized for cooling and managing peak electrical demand globally, offering daily or weekly storage capabilities for both individual homes and larger office buildings. However, scaling these systems for district-level cooling or integrating them with renewable energy sources presents challenges, especially in accommodating larger volumes and addressing seasonal storage requirements in densely populated urban areas. This paper proposes a novel solution by evaluating subsurface ice-based thermal energy storage, in which the underground is subjected to seasonal freeze/thaw cycles. However, these cycles may influence ground behavior, affecting pore pressure and inducing ground movement. To systematically investigate these challenges, we enhance the TOUGH-FLAC simulator by integrating water/ice phase change capabilities and updating the effective stress–strain constitutive relation. Both modifications are validated against analytical solutions or experimental data. Through numerical simulations spanning a decade with ten seasonal freeze/thaw cycles, we evaluate the performance and long-term stability of a generic subsurface ice-based thermal energy storage system, considering factors such as ground permeability, freezing pipe spacing, freeze/thaw damage, and glycol solution temperature. The simulations indicate that ice formation induces pore pressure variations that drive seasonal surface heave and settlement, controlled by ground permeability, pipe spacing, and glycol solution temperature, along with tensile and localized shear deformation around freeze pipes. This highlights the need for accurate ground property characterization and geomechanical analysis for subsurface ice-based thermal energy storage.

Ground freezing↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental demonstration and performance evaluation of a complex fenestration system for daylighting and thermal harvesting

Two significant design strategies for mitigating building energy consumption are daylight redirection and solar energy harvesting. Effective daylighting implementation enhances the amount of useful natural light within a space and offsets the need for electric lighting. Solar energy harvesting systems can mitigate energy costs from mechanical systems by managing incoming thermal loads or capturing solar energy that can be used to supplement thermal systems in the building. While there are many available façade-based technologies that can perform daylighting or solar thermal energy harvesting, there remains a limitation in available systems that can perform both of them simultaneously. This paper, describes the design and experimental demonstration of a Liquid Filled Prismatic Louver (LFPL) system, which combines both energy-saving strategies. The LFPL system was installed in a south-facing room in New York City and evaluated for indoor daylight penetration and potential for thermal energy harvesting. Daylight redirection is achieved through the prismatic louver geometry and proper orientation, whereas thermal energy harvesting is achieved through IR absorption from the liquid (e.g., water) within the prisms. Daylighting performance was evaluated by illuminance measurements at key locations within the space, whereas thermal harvesting performance was evaluated through temperature measurements and thermal imaging analysis. We show that the LFPL system, with all prismatic elements oriented at the same angle, achieve a 2-fold and 8-fold enhancement in daylight redirection to the ceiling, for prism orientations of 10° and 20°, respectively. We also demonstrate the system’s capability to adjust to specific lighting needs, within the space, through the dynamic individual orientation of prismatic elements; thus, achieving a concentrated ceiling illuminance enhancement of ~100 times and ~200 times at 2.5 and 4.3 m away from the window sill, providing workplane illuminance enhancement of 6 and 2 times more than in the case of the control room with regular windows. Furthermore, we illustrate a reduction of potential heating loads at locations close to the window from the combination of infrared absorption in the water volume and the redirection of the incoming solar radiation, leading to a reduction of the workplane temperature by an average of 7–10 °C.

14 SOLAR ENERGY↗

A Historical Review of the Safe Transport of Spent Nuclear Fuel

This report meets the requirements of M3 milestone M3SF-21OR020302066 for the Office of Integrated Waste Management (IWM) and is a revision to M3 milestone M3FT-16OR090402028 for the former Nuclear Fuels Storage and Transportation Planning Project (NFST), “Safety Record of SNF Shipments.” The US Department of Energy (DOE) has since established the IWM, which builds on the work begun by NFST, to develop an integrated waste management system for spent nuclear fuel (SNF), including the development of a large-scale transportation system for the safe transport of SNF to storage or disposal facilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Connecting Electric Vehicle Charging Infrastructure to Commercial Buildings

This factsheet from the National Renewable Energy Laboratory aims to describe how EV chargers can be connected to commercial buildings, including considerations for facility managers, and the effects that charging will have on the buildings electrical distribution system.

Better Buildings, electric vehicle charging, comme↗

A critical review of cyber-physical security for building automation systems

Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.

97 MATHEMATICS AND COMPUTING↗

Energy Management Information Systems Cybersecurity Best Practices

Energy management information systems (EMIS) are a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance. Critical systems are often integrated with or operate on the same networks as EMIS scope systems, necessitating stable, continuous, and secure communication. When connecting EMIS to building automation and utility control systems, there are also many physical assets that could cause harm to the building and its occupants if a malicious act or human error were introduced. It is imperative to ensure all EMIS scope systems are connected securely to the EMIS and do not open vulnerable pathways to other facility networks and operations. The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of EMIS at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of required EMIS cybersecurity standards for compliance and authority to operate along with additional recommendations.

cybersecurity↗