Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A multiple chamber, semicontinuous, crop carbon dioxide exchange system: design, calibration, and data interpretation

Long-term, whole crop CO2 exchange measurements can be used to study factors affecting crop growth. These factors include daily carbon gain, cumulative carbon gain, and carbon use efficiency, which cannot be determined from short-term measurements. We describe a system that measures semicontinuously crop CO2 exchange in 10 chambers over a period of weeks or months. Exchange of CO2 in every chamber can be measured at 5 min intervals. The system was designed to be placed inside a growth chamber, with additional environmental control provided by the individual gas exchange chambers. The system was calibrated by generating CO2 from NaHCO3 inside the chambers, which indicated that accuracy of the measurements was good (102% and 98% recovery for two separate photosynthesis systems). Since the systems measure net photosynthesis (P-net, positive) and dark respiration(R-dark, negative), the data can be used to estimate gross photosynthesis, daily carbon gain, cumulative carbon gain, and carbon use efficiency. Continuous whole-crop measurements are a valuable tool that complements leaf photosynthesis measurements. Multiple chambers allow for replication and comparison among several environmental or cultural treatments that may affect crop growth. Example data from a 2 week study with petunia (Petunia x hybrida Hort. Vilm.-Andr.) are presented to illustrate some of the capabilities of this system.

NASA Discipline Life Support Systems↗

Calibration of the Urbana lidar system

A method for calibrating data obtained by the Urban sodium lidar system is presented. First, an expression relating the number of photocounts originating from a specific altitude range to the soodium concentration is developed. This relation is then simplified by normalizing the sodium photocounts with photocounts originating from the Rayleigh region of the atmosphere. To evaluate the calibration expression, the laser linewidth must be known. Therefore, a method for measuring the laser linewidth using a Fabry-Perot interferometer is given. The laser linewidth was found to be 6 + or - 2.5 pm. Problems due to photomultiplier tube overloading are discussed. Finally, calibrated data is presented. The sodium column abundance exhibits something close to a sinusoidal variation throughout the year with the winter months showing an enhancement of a factor of 5 to 7 over the summer months.

Cerny, T.↗

Interpretation of Probabilistic Surface Ozone Forecasts: A Case Study for Philadelphia

The use of probabilistic forecasting has been growing in a variety of disciplines because of its potential to emphasize the degree of uncertainty inherent in a prediction. Interpretation of probabilistic forecasts, however, is oftentimes difficult, deterring users who may benefit from such forecasts. To encourage broader use of probabilistic forecasts in the field of air quality, a process for interpreting forecasts from a statistical probabilistic air quality surface ozone model [the Regression in Self Organizing Map (REGiS)] is demonstrated. Four procedures to convert probabilistic to deterministic forecasts are explored for the Philadelphia, Pennsylvania, metropolitan area. These procedures calibrate the predicted probability of daily maximum 8-h-average ozone exceeding a standard value by 1) estimating climatological relative frequency, 2) establishing a probability of an exceedance threshold as 50%, 3) maximizing the threat score, and 4) determining the unit bias ratio. REGiS is trained using 2000–11 ozone-season (1 May–30 September) data, calibrated using 2012–14 data, and evaluated using 2015–18 data. Assessment of the calibration data with the Pierce skill score suggests an exceedance threshold based on climatological relative frequency for the conversion from probabilistic to deterministic forecasts. Calibrated REGiS generally compares well to predictions from the U.S. national air quality model and operational “expert” forecasts over the evaluation period. For other probabilistic models and situations, different procedures of converting probabilistic to deterministic forecasts may be more beneficial. The methods presented in this paper represent an approach for operational air quality forecasters seeking to use probabilistic model output to support forecasts designed to protect public health.

Nikolay Balashov↗

Assessment of Temperature-Dependent Regression Model Terms of a RUAG Six-Component Block-Type Balance

A metric called the percent contribution was applied to regression models of temperature-dependent calibration data of a RUAG six-component block-type balance in order to assess the influence of temperature-dependent regression model terms on the balance load prediction. Regression models were examined that are needed if either the Iterative or the Non-Iterative Method is used for the load prediction. Computed values of the percent contribution confirmed that the cross-product term defined by a primary load and the temperature difference is the most influential temperature-dependent term of the regression model of a primary output that the Iterative Method needs. Similarly, the analysis showed that the cross-product term defined by a primary output and the temperature difference is the most influential temperature-dependent term of the regression model of a primary load that the Non-Iterative Method needs. Computed results support conclusions that were reported in an earlier theoretical study. This study asserted that the cross-product term defined by a primary load or output and the temperature difference models the temperature-dependent shift of the gage sensitivity. The influence of other temperature-dependent terms used in the regression models of the calibration data of RUAG's balance was negligible. This observation may be explained by the fact that RUAG's block-type balances have highly linear characteristics. Overall, the percent contribution has proven itself to be a reliable and easy-to-implement metric that may also be used for the assessment of the influence of temperature-dependent regression model terms on the load prediction of a six-component strain-gage balance.

Ulbrich, N.↗

Experience gained from computer processing of physical experimental data during the restoration of measured values

The processing stage in which the restored values of the physical parameters are received is described. The following main steps are discussed: estimation of the state of the telemetry data, processing of the calibration data, and determination of the errors in the data; data decommutation and analysis of the structure of measurement cycles for each instrument; decoding, estimates of the reliability of the restored data, and their agreement with the models adopted for the measurement process; and analysis of errors due to deterministic and random factors. A block diagram of the method is presented.

Mamotko, Z. N.↗

Solar modulation of cosmic ray electrons 1978-1983

The ISEE 3 spacecraft has provided over 4 years of continuous data from nearby interplanetary space. By using these data together with prelaunch calibration data and precise electron spectra from balloon flights in 1979 and 1982 at Thompson, Manitoba, Canada, the flux level of approximately 1 GeV cosmic ray electrons with 1 month time resolution is monitored. The step-like onset of modulation observed for positive particles in 1979 is also seen in electrons, confirming that the dominant modulation mechanism is not sensitive to the charge of the particle. Hysteresis effects observed in the previous solar maximum by Burger and Swanenburg (1973) are not reproduced at the present solar maximum. A return to the relatively higher electron/proton ratios of the 1960s is a strong possibility. Conclusions must be drawn with caution, however, since the overall time structure of the present solar maximum is significantly different from that of the previous one.

Evenson, P.↗

A miniature remote deadweight calibrator

A miniature, computer-controlled, deadweight calibrator was developed to remotely calibrate a force transducer mounted in a cryogenic chamber. This simple mechanism allows automatic loading and unloading of deadweights placed onto a skin friction balance during calibrations. Equipment for the calibrator includes a specially designed set of five interlocking 200-milligram weights, a motorized lifting platform, and a controller box taking commands from a microcomputer on an IEEE interface. The computer is also used to record and reduce the calibration data and control other calibration parameters. The full-scale load for this device is 1,000 milligrams; however, the concept can be extended to accommodate other calibration ranges.

Supplee, Frank H., Jr.↗

Optical, ultraviolet, and infrared observations of cooling flows in rich clusters

Many rich clusters are now known to possess centrally located optically emitting gas systems, which accompany large inflows of cooling cluster gas. Recent results of optical, UV, and IR studies on cooling flow clusters are reported which center on three topics: (1) spectroscopic studies of the velocity structure of the line-emitting gas systems, which are used to probe the dynamics of the central cluster regions; (2) filter imaging studies of cluster emission line systems, which have yielded line luminosities and characteristic angular scales; and (3) the results of combining this optical survey with similar surveys undertaken using ultraviolet and infrared satellite data. Carefully flux-calibrated data from this multiwavelength data base have been used to show that a small but significant component of dust extinction is associated with the environment of these clusters.

Hu, Esther M.↗

A technique for extrapolating and validating forest cover across large regions - Calibrating AVHRR data with TM data

A method is presented for extending high-resolution forest cover information across large regions. Using Landsat TM data with AVHRR data, an empirical relationship beween AVHRR spectral signatures and forest cover is developed. The resulting regression equation is applied to an AVHRR scene covering a large area centered around southern Illinois. The map is used to estimate forest cover within a geographical information system. The results are compared with U.S. Forest Service estimates, showing good agreement.

Iverson, L. R.↗

ARID relative calibration experimental data and analysis

Several experiments measure the orientation error of the ARID end-frame as well as linear displacements in the Orbiter's y- and z-axes. In each experiment the position of the ARID on the trolley is fixed and the manipulator extends and retracts along the Orbiter's y-axis. A sensor platform consisting of four sonars arranged in a '+' pattern measures the platform pitch about the Orbiter's y-axis (angle b) and yaw about the Orbiter's x-axis (angle alpha). Corroborating measurements of the yaw error were performed using a carpenter's level to keep the platform perpendicular to the gravity vector at each ARID pose being measured.

Doty, Keith L↗

The Critical Importance of Data Reduction Calibrations in the Interpretability of S-type Asteroid Spectra

There is significant dispute concerning the interpretation and meteoritic affinities of S-type asteroids. Some of this arises from the use of inappropriate analysis methods and the derivation of conclusions which cannot be supported by those interpretive methodologies [1]. The most frequently applied inappropriate technique is curve matching. Whether matching spectra from a spectral library or mixing end-member spectra to match the asteroid spectrum, curve matching for S-type spectra suffers from a suite of weaknesses that are virtually impossible to overcome. Chief among these is the lack of a comprehensive comparison set. Lacking a complete library that includes both the mineralogical variations and the spectrally significant physical variations (e.g., particle size, petrographic relationships, etc.), curve matches are plagued with potential unresolved ambiguities. The other major weakness of virtually all curve matching efforts is that equal weight is given to matching all portions of the spectrum. In actuality, some portions of the spectrum (e.g., centers of absorption features) must be matched very accurately while other portions of the spectrum (e.g., continuum regions and overall slopes) do not require good matches since they are strongly effected by parameters unrelated to the mineralogy of the sample.

Gaffey, Michael J.↗

Long-Lasting Science Returns from the Apollo Heat Flow Experiments

The Apollo astronauts deployed geothermal heat flow instruments at landing sites 15 and 17 as part of the Apollo Lunar Surface Experiments Packages (ALSEP) in July 1971 and December 1972, respectively. These instruments continuously transmitted data to the Earth until September 1977. Four decades later, the data from the two Apollo sites remain the only set of in-situ heat flow measurements obtained on an extra-terrestrial body. Researchers continue to extract additional knowledge from this dataset by utilizing new analytical techniques and by synthesizing it with data from more recent lunar orbital missions such as the Lunar Reconnaissance Orbiter. In addition, lessons learned from the Apollo experiments help contemporary researchers in designing heat flow instruments for future missions to the Moon and other planetary bodies. For example, the data from both Apollo sites showed gradual warming trends in the subsurface from 1971 to 1977. The cause of this warming has been debated in recent years. It may have resulted from fluctuation in insolation associated with the 18.6-year-cycle precession of the Moon, or sudden changes in surface thermal environment/properties resulting from the installation of the instruments and the astronauts' activities. These types of reanalyses of the Apollo data have lead a panel of scientists to recommend that a heat flow probe carried on a future lunar mission reach 3 m into the subsurface, approx 0.6 m deeper than the depths reached by the Apollo 17 experiment. This presentation describes the authors current efforts for (1) restoring a part of the Apollo heat flow data that were left unprocessed by the original investigators and (2) designing a compact heat flow instrument for future robotic missions to the Moon. First, at the conclusion of the ALSEP program in 1977, heat flow data obtained at the two Apollo sites after December 1974 were left unprocessed and not properly archived through NASA. In the following decades, heat flow data from January 1975 through February 1976, as well as the metadata necessary for processing the data (the data reduction algorithm, instrument calibration data, etc.), were somehow lost. In 2010, we located 450 original master archival tapes of unprocessed data from all the ALSEP instruments for a period of April through June 1975 at the Washington National Records Center. We are currently extracting the heat flow data packets from these tapes and processing them. Second, on future lunar missions, heat flow probes will likely be deployed by a network of small robotic landers, as recommended by the latest Decadal Survey of the National Academy of Science. In such a scenario, the heat flow probe must be a compact system, and that precludes use of heavy excavation equipment such as a rotary drill for reaching the 3-m target depth. The new heat flow system under development uses a pneumatically driven penetrator. It utilizes a stem that winds out of a reel and pushes its conical tip into the regolith. Simultaneously, gas jets, emitted from the cone tip, loosen and blow away the soil. Lab experiments have demonstrated its effectiveness in lunar vacuum.

Nagihara, S.↗

The Use of Absolute-Value Terms in Regression Modeling of Multi-Piece Force Balances

Different aspects of the use of absolute-value terms in regression models of the electrical outputs of multi-piece force balance calibration data are discussed. First, characteristics of a variety of regression model term combinations with absolute-value terms are reviewed that are currently used in the aerospace testing community to fit the gage outputs of a balance. Then, a semi-empirical test is presented that quantifies bidirectional characteristics of the balance bridge outputs. Several diagnostic methods are discussed to assess the severity of near-linear dependencies between regressors of models with absolute-value terms. In particular, connections between the linear, absolute-value, quadratic, signed quadratic, and cubic terms are studied in greater detail. Data from an automated calibration of NASAs MK29B force balance are used to illustrate the most important observations and results. Rules of thumb that variance-inflation factors be less than 10 must be relaxed when using absolute-value terms to describe bidirectional balances.

calibration analysis↗