Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

VLA observations of rapid 6 cm flux variations in alpha Ori

The red supergiant star alpha Ori was monitored with the Very Large Array (VLA). Thirteen observations at 6 cm show stochastic variations, at the 30 to 40 percent level, with no long term trend. All data was clipped and tapered in AIPS to minimize differences between VLA arrays. The calibration source varied by less than 10 percent over the same interval. The VLA observations of alpha Ori were continued, as well as alpha Her and alpha Sco, at both 2 and 6 cm, to confirm this result and search for long term trends. The stochastic 6 cm flux behavior, with 30 to 40 percent changes on all timescales from the shortest interval of 10 days to the longest, seems at odds with the 400 day periodic variations in U-band photometry and Mg II UV fluxes reported by Dupree, et al. The observed 6 cm flux was 25 percent below the 6 cm flux reported earlier this decade. Several models for the outer atmosphere of alpha Ori place the 6 cm optical depth unity location at several stellar radii above the optical photosphere. The rapid, stochastic variations reported are difficult to reconcile with almost any global process, such as pulsation, Alfven waves or periastron passage.

Bookbinder, J. A.↗

Supernova 1987A - A radiosphere resolved with VLBI five days after the neutrino burst

The results of VLBI observations of SN1987A are reported. No emission from the supernova above a level of about 20 percent of the supernova's total flux density was detected, although signals were detected from two calibrator sources with amplitudes roughly equal to those determined in earlier VLBI observations. It is inferred that the supernova's radiosphere was resolved, and a lower bound on the radiosphere's radius of 2.2 mas is estimated from an epoch 5.2 days after the neutrino burst. Given the photometric data from the supernova, a distance to the LMC of 50 + or - 5 kpc, and an apparent expansion velocity that varied systematically with time from 18,000-16,000 km/s, as estimated from the blue-shifted H-alpha absorption lines on the days preceding the observations, it is concluded that 5.2 days after the neutrino burst the supernova's radiosphere was at least 2.5 times larger than the inferred blackbody photosphere, and at least as large as the H-alpha line-forming region.

Jauncey, D. L.↗

Development of the CLAES instrument aperture door system

The design, assembly, and test processes followed in developing a space-qualified aperture door system are described. A blackbody calibration source is mounted inside the door, requiring the assembly to open and close a minimum of 150 cycles for instrument recalibration. Within the door system are four separate mechanisms, three of which are redundant; a pyro launch latch, a hinge bearing assembly, and a pair of pivot mechanisms. Decoupling devices within the pivot mechanisms allow an active drive unit to automatically overdrive a failed drive unit. The door is also stowable for possible Shuttle retrieval and re-entry. Illustrations and photographs of the flight hardware help acquaint the reader with the design. The aim is to pass on lessons learned in all phases of developing this spaceflight mechanism.

Stubbs, D. M.↗

Cryogenic Limb Array Etalon Spectrometer (CLAES) - Instrument overview

The design and capabilities of CLAES are described. The CLAES is an instrument on NASA's Upper Atmosphere Research Satellite (UARS) and measures the global concentrations of stratospheric species and temperature over the altitude range 10-60 km. Consideration is given to the motorized limb acquisition and adjustment mirror, solid cryogen cooler, optical system, electronics subsystems, cryostat, and IR calibration source. Diagrams of the CLAES and UARS are provided.

Burriesci, Larry↗

Radio emission in peculiar galaxies

During the last decades a number of surveys of peculiar galaxies have been carried out and accurate positions become available. Since peculiarities are a possible evidence of radio emission (Wright, 1974; Sulentic, 1976; Stocke et al., 1978), the authors selected a sample of 24 peculiar galaxies with optical jet-like features or extensions in different optical catalogues, mainly the Catalogue of Southern Peculiar Galaxies and Associations (Arp and Madore, 1987) and the ESO/Uppsala Survey of the ESO(B) Atlas (Lauberts, 1982) for observation at the radio continuum frequency of 22 GHz. The sample is listed in a table. Sol (1987) studied this sample and concluded that the majority of the jet-like features seem to admit an explanation in terms of interactive galaxies with bridges and/or tails due to tidal effects. Only in a few cases do the jets seem to be possibly linked to some nuclear activity of the host galaxy. The observations were made with the 13.7m-radome enclosed Itapetinga Radiotelescope (HPBW of 4.3 arcmin), in Brazil. The receiver was a 1 GHz d.s.b. super-heterodine mixer operated in total-power mode, with a system temperature of approximately 800 K. The observational technique consisted in scans in right ascention, centralized in the optical position of the galaxy. The amplitude of one scan was 43 arcmin, and its duration time was 20 seconds. The integration time was at least 2 hours (12 ten-minute observations) and the sensibility limit adopted was an antenna temperature greater than 3 times the r.m.s. error of the baseline determination. Virgo A was used as the calibrator source. Three galaxies were detected for the first time as radio sources and four other known galaxies at low frequencies had their flux densities measured at 22 GHz. The results for these sources are presented.

Demellorabaca, Dulia F.↗

Measurements of induced radioactivity in some LDEF samples

Twenty-six stainless steel trunnion samples, five aluminum end support retainer plate samples, two aluminum keel plate samples, and two titanium clips were analyzed. The shielded high purity germanium detectors used had efficiencies of 33, 54, and 80 pcts. at 1332 keV. Detector efficiencies as a function of energy and corrections for self absorption in the samples were determined with calibrated sources, unactivated control samples, and calculations. Several measurements were made on most samples. In the trunnion samples, Mn-54 and Co-57 were seen and limits were obtained for other isotopes. The results agree well with 1-D activation calculations for an anisotropic trapped proton model. In the aluminum samples, Na-22 and Be-7 were seen. Other results are presented.

Moss, C. E.↗

Measurements of induced radioactivity in some LDEF samples

Twenty-six stainless steel trunnion samples, five aluminum end support retainer plate samples, two aluminum keel plate samples, and two titanium clips were analyzed. The shielded high purity germanium detectors used had efficiencies of 33, 54, and 80 percent at 1332 keV. Detector efficiencies as a function of energy and corrections for self-absorption in the samples were determined with calibrated sources and unactivated control samples. Several measurements were made on most samples. In the trunnion samples, Mn-54 and Co-57 were seen and limits were obtained for other isotopes. The results agree well with 1-D activation calculations for an anisotropic trapped proton model. In the aluminum and titanium samples, Na-22 was detected. Other results are presented.

Moss, C. E.↗

DSS-13 26-meter antenna upgraded radiometer system

The Deep Space Station (DSS)-13 26-m antenna radiometer system was upgraded with an IBM-compatible computer-controlled configuration with improved supporting hardware and software. Software was generated to analyze results and correct for antenna mispointing, tropospheric loss, and other observing errors. This total power radiometer configuration provides a prototype for the new DSS-13 34-m antenna. The radiometer system is described in terms of the theory, instrumentation hardware, computer configuration, and operational features and performance. The system is used to obtain antenna efficiency and pointing model data and is useful for radio source calibrations required for radio astronomy. Some recent results are given.

Stelzried, C. T.↗

Far ultraviolet spectrophotometry of BD +28 4211

The results are reported of a November 1989 rocket flight which recorded a flux-calibrated spectrum of BD +28 4211 from 912 to 1150 A with 1A resolution. BD +28 4211, an SdO-type star, is commonly used as an ultraviolet calibration source in the IUE wavelength band. The present work extends the useful range of this standard shortward of Lyman-alpha. Since previous experiments show marked disparity, this study can be useful in determining a standard in the 912 to 1216 A band.

Cook, Timothy A.↗

Effective area of the AXAF X-ray telescope - Dependence upon dielectric constants of coating materials

This study examines the dependence of the effective area of the AXAF X-ray telescope upon the complex dielectric constants of possible mirror coatings, over the energy range 0.1-10 keV. At energies near and above the astrophysically important iron-line complex near 6.7 keV, the effective area is very sensitive to the coating density on the three innermost of the telescope's six mirror pairs. Thus, it is desirable to achieve as high a density as feasible. The telescope's spectral response exhibits sharp features at absorption edges of the coating materials. In view of the exceptional energy resolution of the AXAF spectrometers and uncertainties in reflectivities (especially near absorption edges), the AXAF goal of 1-percent accuracy requires both the precise X-ray calibration of the telescope and improved modeling of the telescope and calibration sources. Presented here in the form of plots, the results are also available (on floppy disks) in tabular form.

Elsner, R. F.↗

Preliminary efforts toward development of data handling and analysis software for unsteady flow measurements: An application for aeroelastic transonic flow configurations

A few years ago the Structural Dynamics Division at LaRC started ambitious experimental research efforts known as the Benchmark Models Program. The primary objective of this program was to provide experimental data that may serve as a calibration source for computational fluid dynamics (CFD) efforts that deal with aeroelastic unsteady flow configurations. It also focuses on the understanding of complex flow phenomenon associated with unsteady flow developments. The overall plan for the program has been described by Bennett, including a presentation of initial test results of flutter of a rigid wing mounted on flexible supports. An example of a test model employed to measure the dynamic response along with corresponding pressure distributions is shown. This model incorporates eighty pressure transducers distributed along two spanwise stations. In addition, the models are equipped with four accelerometers and two strain gages. The data handling system for the Benchmark Model Program is under development. Several interactive computer routines designed for the user interface, dynamic memory allocation, unsteady flow measurements data extraction, and further data processing were developed. To present a few examples of measured data, the unsteady pressure distributions and the wing model dynamic response were plotted.

Finaish, Fathi↗

Solar measurements from the Airglow-Solar Spectrometer Instrument (ASSI) on the San Marco 5 satellite

The analysis of the solar spectral irradiance from the Airglow-Solar Spectrometer Instrument (ASSI) on the San Marco 5 satellite is the focus for this research grant. A pre-print copy of the paper describing the calibrations of and results from the San Marco ASSI is attached to this report. The calibration of the ASSI included (1) transfer of photometric calibration from a rocket experiment and the Solar Mesosphere Explorer (SME), (2) use of the on-board radioactive calibration sources, (3) validation of the ASSI sensitivity over its field of view, and (4) determining the degradation of the spectrometers. We have determined that the absolute values for the solar irradiance needs adjustment in the current proxy models of the solar UV irradiance, and the amount of solar variability from the proxy models are in reasonable agreement with the ASSI measurements. This research grant also has supported the development of a new solar EUV irradiance proxy model. We expected that the magnetic flux is responsible for most of the heating, via Alfen waves, in the chromosphere, transition region, and corona. From examining time series of solar irradiance data and magnetic fields at different levels, we did indeed find that the chromospheric emissions correlate best with the large magnetic field levels.

Woods, Thomas N.↗

Integrated Cryogenic Satellite Communications Cross-Link Receiver Experiment

An experiment has been devised which will validate, in space, a miniature, high-performance receiver. The receiver blends three complementary technologies; high temperature superconductivity (HTS), pseudomorphic high electron mobility transistor (PHEMT) monolithic microwave integrated circuits (MMIC), and a miniature pulse tube cryogenic cooler. Specifically, an HTS band pass filter, InP MMIC low noise amplifier, HTS-sapphire resonator stabilized local oscillator (LO), and a miniature pulse tube cooler will be integrated into a complete 20 GHz receiver downconverter. This cooled downconverter will be interfaced with customized signal processing electronics and integrated onto the space shuttle's 'HitchHiker' carrier. A pseudorandom data sequence will be transmitted to the receiver, which is in low Earth orbit (LEO), via the Advanced Communication Technology Satellite (ACTS) on a 20 GHz carrier. The modulation format is QPSK and the data rate is 2.048 Mbps. The bit error rate (BER) will be measured in situ. The receiver is also equipped with a radiometer mode so that experiment success is not totally contingent upon the BER measurement. In this mode, the receiver uses the Earth and deep space as a hot and cold calibration source, respectively. The experiment closely simulates an actual cross-link scenario. Since the receiver performance depends on channel conditions, its true characteristics would be masked in a terrestrial measurement by atmospheric absorption and background radiation. Furthermore, the receiver's performance depends on its physical temperature, which is a sensitive function of platform environment, thermal design, and cryocooler performance. This empirical data is important for building confidence in the technology.

Romanofsky, R. R.↗

Evaluation of Chemical Coating Processes for AXAF

The need existed at MSFC for the development and fabrication of radioisotope calibration sources of cadmium 109 and iron 55 isotopes. This was in urgent response to the AXA-F program. Several issues persisted in creating manufacturing difficulties for the supplier. In order to meet the MSFC requirements very stringent control needed to be maintained for the coating quality, specific activity and thickness. Due to the difficulties in providing the precisely controlled devices for testing, the delivery of the sources was seriously delayed. It became imperative that these fabrication issues be resolved to avoid further delays in this AXA-F observatory key component. The objectives are: 1) Research and provide expert advice on coating materials and procedures. 2) Research and recommend solutions to problems that have been experienced with the coating process. 3) Provide recommendations on the selection and preparation of substrates. 4) Provide consultation on the actual coating process including the results of the qualification and acceptance test programs. 5) Perform independent tests at UAH or MSFC as necessary.

Engelhaupt, Darell↗

Infrared space observatory photometry of circumstellar dust in Vega-type systems

The ISOPHOT (Infrared Space Observatory Photometry) instrument onboard the Infrared Space Observatory (ISO) was used to obtain 3.6-90 micron photometry of Vega-type systems. Photometric data were calibrated with the ISOPHOT fine calibration source 1 (FCS1). Linear regression was used to derive transformations to make comparisons to ground-based and IRAS photometry systems possible. These transformations were applied to the photometry of 14 main-sequence stars. Details of these results are reported on.

Fajardo-Acosta, S. B.↗

Evaluation of Chemical Coating Processes for AXAF

The need existed at MSFC for the development and fabrication of radioisotope calibration sources of cadmium 109 and iron 55 isotopes. This was in urgent response to the AXAF program. Several issues persisted in creating manufacturing difficulties for the supplier. In order to meet the MSFC requirements very stringent control needed to be maintained for the coating quality, specific activity and thickness. Due to the difficulties in providing the precisely controlled devices for testing, the delivery of the sources was seriously delayed. It became imperative that these fabrication issues be resolved to avoid further delays in this AXAF observatory key component.

Engelhaupt, Darell E.↗

Analysis of Ultra-Pure Gases by Ion Mobility Spectrometry

Work has continued with the evaluation of the Ion Mobility Spectrometer (IMS) for the analysis of gases having low parts-per-billion (10(exp -9)) water concentration. A modified PCP, inc. MMS-160 Mobility Mass Spectrometer System was used for the analysis of ultra-pure argon and nitrogen. The MMS-160 system permits the mass-identification of unique reactant and product ions observed in the reduced-water host gases. When the water is removed to low ppb levels, higher energy reactant ions are observed. In nitrogen, distinct odd- and even-numbered nitrogen cluster ion mobility peaks are observed, as well as adduct ion peaks from the trace contaminants in the gas. Argon also produces a cluster ion mobility peak and adduct ion peaks from trace components in the gas. Levels of contaminants in these ultra-pure gases can be determined from the ion mobility spectra. A calibrated source was used to provide variable known quantities of water to the pure gas supply of the IMS.

Stimac, Robert M.↗

On the Use of Monochromators for the Calibration of AXAF

Data acquired, during the AXAF calibration at MSFC's X-Ray Calibration Facility (XRCF), using monochromators requires special analysis owing to potentially large spatial variations in the monochromators' beams and to higher-order contributions to the spectral content. A description of the monochromators -- the Double-Crystal Monochromator (DCM) and the HIgh-Resolution Erect-Field Spectrometer (HIREFS\TM) reflection-grating monochromator --- is given, followed by a discussion of the spectral and spatial content as monitored by Beam-Normalization Detector (BND) flow proportional counters (FPCs). Emphasis is given to the methodology employed in determining the spatial content through fits to Beam Uniformity (BU) measurements made nonsimultaneously, either during calibration or during pre-calibration source characterization. We present an interpolation scheme which adequately represents the beam properties over a wide range of source conditions.

Swartz, Douglas A.↗