Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The University of Hawaii Institute for Astronomy CCD camera control system

The University of Hawaii Institute for Astronomy CCD Camera Control System consists of a NeXT workstation, a graphical user interface, and a fiber optics communications interface which is connected to a San Diego State University CCD controller. The UH system employs the NeXT-resident Motorola DSP 56001 as a real time hardware controller. The DSP 56001 is interfaced to the Mach-based UNIX of the NeXT workstation by DMA and multithreading. Since the SDSU controller also uses the DPS 56001, the NeXT is used as a development platform for the embedded control software. The fiber optic interface links the two DSP 56001's through their Synchronous Serial Interfaces. The user interface is based on the NeXTStep windowing system. It is easy to use and features real-time display of image data and control over all camera functions. Both Loral and Tektronix 2048 x 2048 CCD's have been driven at full readout speeds, and the system is intended to be capable of simultaneous readout of four such CCD's. The total hardware package is compact enough to be quite portable and has been used on five different telescopes on Mauna Kea. The complete CCD control system can be assembled for a very low cost. The hardware and software of the control system has proven to be quite reliable, well adapted to the needs of astronomers, and extensible to increasingly complicated control requirements.

Jim, K. T. C.↗

A simple fuzzy logic real-time camera tracking system

A fuzzy logic control of camera pan and tilt has been implemented to provide real-time camera tracking of a moving object. The user clicks a mouse button to identify the object that is to be tracked. A rapid centroid estimation algorithm is used to estimate the location of the moving object, and based on simple fuzzy membership functions, fuzzy x and y values are input into a six-rule fuzzy logic rule base. The output of this system is de-fuzzified to provide pan and tilt velocities required to keep the image of the object approximately centered in the camera field of view.

Magee, Kevin N.↗

Development of a drive system for a sequential space camera

Breadboard models of single and dual motor drives for the shutter, claw and magazine of a space camera system were designed and tested. The single motor technique utilizes a single electronically commutated motor to drive the claw and shutter without resorting to a solenoid actuated clutch for pulse operation. Shutter speed is established by a combination of the cinemode speed and the opening of the conventional DAC two piece shutter. Pulse mode operation is obtained by applying power at a fixed clock rate and removing power at an appropriate point in the mechanical cycle such that the motor comes to rest by system friction. The dual motor approach utilizes a stepper motor to drive the shutter and an electronically commutated dc motor to drive the claw and magazine functions. The motors are synchronized electronically.

Sharpsteen, J. T.↗

Optical synthesizer for a large quadrant-array CCD camera: Center director's discretionary fund

The objective of this program was to design and develop an optical device, an optical synthesizer, that focuses four contiguous quadrants of a solar image on four spatially separated CCD arrays that are part of a unique CCD camera system. This camera and the optical synthesizer will be part of the new NASA-Marshall Experimental Vector Magnetograph, and instrument developed to measure the Sun's magnetic field as accurately as present technology allows. The tasks undertaken in the program are outlined and the final detailed optical design is presented.

Hagyard, Mona J.↗

Integrated inertial stellar attitude sensor

An integrated inertial stellar attitude sensor for an aerospace vehicle includes a star camera system, a gyroscope system, a controller system for synchronously integrating an output of said star camera system and an output of said gyroscope system into a stream of data, and a flight computer responsive to said stream of data for determining from the star camera system output and the gyroscope system output the attitude of the aerospace vehicle.

Brady, Tye M.↗

A star camera aspect system suitable for use in balloon experiments

A balloon-borne experiment containing a star camera aspect system was designed, built, and flown. This system was designed to provide offset corrections to the magnetometer and inclinometer readings used to control an azimuth and elevation pointed experiment. The camera is controlled by a microprocessor, including commendable exposure and noise rejection threshold, as well as formatting the data for telemetry to the ground. As a background program, the microprocessor runs the aspect program to analyze a fraction of the pictures taken so that aspect information and offset corrections are available to the experiment in near real time. The analysis consists of pattern recognition of the star field with a star catalog in ROM memory and a least squares calculation. The performance of this system in ground based tests is described. It is part of the NASA/GSFC High Energy Gamma-Ray Balloon Instrument (2).

Hunter, S. D.↗

End-to-End System Test of the Relative Precision and Stability of the Photometric Method for Detecting Earth-Size Extrasolar Planets

We developed the CCD camera system for the laboratory test demonstration and designed the optical system for this test. The camera system was delivered to Ames in April, 1999 with continuing support mostly in the software area as the test progressed. The camera system has been operating successfully since delivery. The optical system performed well during the test. The laboratory demonstration activity is now nearly complete and is considered to be successful by the Technical Advisory Group, which met on 8 February, 2000 at the SETI Institute. A final report for the Technical Advisory Group and NASA Headquarters will be produced in the next few months. This report will be a comprehensive report on all facets of the test including those covered under this grant. A copy will be forwarded, if desired, when it is complete.

Dunham, Edward W.↗

System for Photogrammetry, Imaging, Detection, and Ranging, Software Design

Kennedy Space Center (KSC) uses high level pan/tilt camera systems in order to capture data for image analysis. As of right now, we know that current camera systems need to be man-operated, range greatly in costs, and are supplied by third parties. This project, System for Photogrammetric Imaging, Detection, and Ranging, otherwise known as SPIDR, aims to provide high quality image analysis from data drawn from the pan/tilt camera system to upgrade KSC’s ability to take images, and improve space flight and tracking. What this abstract will do, is explain the software needed to carry out such important tasks.

R.S. Kim↗

Phase locking of field sequential color wheel for small TV camera

System employs synchronous motor driven by deflection waveform of TV and connected directly to color filter wheel to phase lock wheel to deflection unit. Innovation stabilizes color response of small TV cameras and allows for small, lightweight installations. Problems associated with motor phase changes are cited.

Niemyer, L. L.↗

Camera Setup for Unsteady Pressure Sensitive Paint at NASA Ames Research Center

The unsteady Pressure-Sensitive Paint Development Team at NASA Ames Research Center is conducting a Launch Vehicle Demo Test in the Unitary Plan Wind Tunnel’s 11-ft Transonic Wind Tunnel in the first half of 2024 to showcase improvements made to unsteady Pressure-Sensitive Paint technology. The unsteady Pressure-Sensitive Paint setup has upgraded from a four-camera system to an eight-camera system, prompting analysis to maximize the system performance and overall data quality. Additional analysis was performed to maximize the system resolving power when subject to test constraints such as model size and model tunnel positions. These analyses have uncovered new opportunities to improve the unsteady Pressure-Sensitive Paint technology and will allow the system to collect higher quality data with simple changes to the setup procedure.

Camera Calibration↗

Determination of the Meteor Limiting Magnitude

The limiting meteor magnitude of a meteor camera system will depend on the camera hardware and software, sky conditions, and the location of the meteor radiant. Some of these factors are constants for a given meteor camera system, but many change between meteor shower or sporadic source and on both long and short timescales. Since the limiting meteor magnitude ultimately gets used to calculate the limiting meteor mass for a given data set, it is important to have an understanding of these factors and to monitor how they change throughout the night, as a 0.5 magnitude uncertainty in limiting magnitude translates to a uncertainty in limiting mass by a factor of two.

Kingery, A.↗

Three-Dimensional Tracking of High-Speed Tumbling Projectiles Using Stroboscopic Imaging

Creating images of high-speed projectiles has been a topic of interest for almost a century. Historically, ballistics ranges have used air-gap flash photography or high-speed video cameras to capture this type of data. Air-gap flash photography provides a single image at each camera station. Using modern high-speed imagers provides accurate data but is cost prohibitive for a long-distance range. This paper presents a camera system capable of capturing the three-dimensional data of high speed projectiles over a long distance. The system uses relatively low-cost cameras which are set up in a stereo vision configuration and uses high-speed strobe lights to create multi exposure images. Each pulse of light captures the position of the projectile as it passes the camera. For each position captured in the image, the three-dimensional position of the projectile is found using triangulation geometry. The linear velocity of the projectile is calculated by combining the position of the projectile with timing data. Two test series were conducted. The first test series compares different cameras and backdrops for the camera system. The second test series captured position data for two different shapes of high-speed tumbling projectiles.

42 ENGINEERING↗

Requirements for particulate monitoring system for Space Station

We recommend that a stereo camera system be utilized as a diagnostic for the particulate environment surrounding the Space Station. This system should have sufficient sensitivity to identify contaminated periods, to isolate the effects of sources and activities and to determine optical clearing times. A reasonable compromise between sensitivity and other operational constraints is recommended. Sensitivity comparable to the film camera systems should suffice, but long periods of unattended operation and remotely controlled exposure sequences are essential requirements.

Green, Byron David↗

OpenCV and TYZX : video surveillance for tracking.

As part of the National Security Engineering Institute (NSEI) project, several sensors were developed in conjunction with an assessment algorithm. A camera system was developed in-house to track the locations of personnel within a secure room. In addition, a commercial, off-the-shelf (COTS) tracking system developed by TYZX was examined. TYZX is a Bay Area start-up that has developed its own tracking hardware and software which we use as COTS support for robust tracking. This report discusses the pros and cons of each camera system, how they work, a proposed data fusion method, and some visual results. Distributed, embedded image processing solutions show the most promise in their ability to track multiple targets in complex environments and in real-time. Future work on the camera system may include three-dimensional volumetric tracking by using multiple simple cameras, Kalman or particle filtering, automated camera calibration and registration, and gesture or path recognition.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Scaling of Microcavity Plasmas Toward 1 µm. Science and Engineering of Spatially-Confined, Low Temperature Plasmas

The DOE has provided, by means of the American Recovery and Reinvestment Act (ARRA), $146,400 in funding for the purchase of scientific equipment. Specifically, these funds have enabled the purchase of two scientific cameras that have already been applied to the research in microcavity plasmas at the University of Illinois (Urbana). The first camera system that was purchased with these funds is a gated ICCD system that allows events as short as 5 ns in time to be captured. It is difficult to express the impact that this equipment has already had on our research. Despite having arrived just 6 - 7 months ago, this camera system has already been used by five graduate students and several undergraduates to capture phenomena that we simply could not see in the past. As an example, the low temperature plasma confined to a spiral structure we fabricate in the Al/Al₂O₃ materials system appears, on long time scales such as those we see with our eyes, to be spatially uniform. However, when captured with the new camera system, the plasma actually is formed initially at the center of the spiral and then moves radially (literally, "jumping" over channels as it goes) at a velocity of a few km/sec. This is an exciting result and I should add that the camera shows that plasma standing waves are produced in some of the structures as well. We do not currently understand all of the phenomena we are witnessing but it is obvious that this new system has quite literally opened new areas of plasma research and application. The second system purchased under this ARRA grant is an infrared system that is far more sensitive than anything our laboratory (or the University of Illinois, for that matter) has had previously. Although fewer experiments have been completed to date with this second camera, it is already clear that it is, indeed, extremely sensitive and it is slated for several experiments in the near future in which we will be measuring the infrared spectra of several arrays of microcavity plasmas. In summary, let me express my thanks to the DOE for granting these funds. We are most grateful for the extraordinary scientific capability that thee funds provide our students. We expect that the scientific data already acquired by this equipment will result in several publications in the next 2 - 3 months (two are being written now). Furthermore, the ability we now have to watch plasmas evolve on the nanosecond time scale has given us several ideas that are likely to result in patent applications. On behalf of our students and myself, I thank the DOE for this exceptional equipment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent Advances in Video Meteor Photometry

One of the most common (and obvious) problems with video meteor data involves the saturation of the output signal produced by bright meteors, resulting in the elimination of such meteors from photometric determinations. It is important to realize that a "bright" meteor recorded by intensified meteor camera is not what would be considered "bright" by a visual observer - indeed, many Generation II or III camera systems are saturated by meteors with a visual magnitude of 3, barely even noticeable to the untrained eye. As the relatively small fields of view (approx.30 ) of the camera systems captures at best modest numbers of meteors, even during storm peaks, the loss of meteors brighter than +3 renders the determination of shower population indices from video observations even more difficult. Considerable effort has been devoted by the authors to the study of the meteor camera systems employed during the Marshall Space Flight Center s Leonid ground-based campaigns, and a calibration scheme has been devised which can extend the useful dynamic range of such systems by approximately 4 magnitudes. The calibration setup involves only simple equipment, available to amateur and professional, and it is hoped that use of this technique will make for better meteor photometry, and move video meteor analysis beyond the realm of simple counts.

Swift, Wesley R.↗

The National Ignition Facility Neutron Imaging System

The National Ignition Facility (NIF) is scheduled to begin deuterium-tritium (DT) shots possibly in the next several years. One of the important diagnostics in understanding capsule behavior and to guide changes in Hohlraum illumination, capsule design, and geometry will be neutron imaging of both the primary 14 MeV neutrons and the lower-energy downscattered neutrons in the 6-13 MeV range. The neutron imaging system (NIS) described here, which we are currently building for use on NIF, uses a precisely aligned set of apertures near the target to form the neutron images on a segmented scintillator. The images are recorded on a gated, intensified charge coupled device. Although the aperture set may be as close as 20 cm to the target, the imaging camera system will be located at a distance of 28 m from the target. At 28 m the camera system is outside the NIF building. Because of the distance and shielding, the imager will be able to obtain images with little background noise. The imager will be capable of imaging downscattered neutrons from failed capsules with yields Y{sub n}>10{sup 14} neutrons. The shielding will also permit the NIS to function at neutron yields >10{sup 18}, which is in contrast to most other diagnostics that may not work at high neutron yields. The following describes the current NIF NIS design and compares the predicted performance with the NIF specifications that must be satisfied to generate images that can be interpreted to understand results of a particular shot. The current design, including the aperture, scintillator, camera system, and reconstruction methods, is briefly described. System modeling of the existing Omega NIS and comparison with the Omega data that guided the NIF design based on our Omega results is described. We will show NIS model calculations of the expected NIF images based on component evaluations at Omega. We will also compare the calculated NIF input images with those unfolded from the NIS images generated from our NIS numerical modeling code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Video Diagnostic for W7-X Stellarator

The video diagnostics for W7-X--which is under development--is devoted to observe plasma and frrst wall elements during operation, to warn in case of hot spots and dangerous heat load and to give information about the plasma size, position, edge structure, the geometry and location of magnetic islands and distribution of impurities. The video diagnostics will be mounted on the tangential AEQ-ports of the torus that are not straight and have about 2m length and a typical diameter of 0.1m which makes its realization more difficult. The geometry of the 10 tangential views of the AEQ-ports allows giving an almost complete overview of the vessel interior making this diagnostic indispensable for the machine operation. Different concepts of the diagnostics were investigated and finally the following design was selected. As a large heat load is expected on the optical window located at the plasma-facing end of the AEQ-port, the port window is protected by a cooled pinhole. An uncooled shutter located behind the pinhole can be closed to prevent window contamination during vessel conditioning discharges (glow discharge cleaning) and from inter-pulse deposition of soft a-C:H layers. The imaging optics and the detection sensor are located behind the port window in the port tube, which will be under atmospheric pressure. To detect the visible radiation distribution a new camera system called Event Detection Intelligent Camera (EDICAM) is under development. The system is divided into three major separated components. The Sensor Module contains only the selected CMOS sensor, the analog digital converters and the minimal electronics necessary for the communication with the subsequent camera system module called Image Processing and Control Unit (IPCU). Its simple structure makes the Sensor Module suitable to operate despite being exposed to ionizing (neutron, {gamma}-) radiation. The IPCU, which can be located far from the Sensor Module and therefore far from the plasma, is designed to perform real time evaluation of the images detecting predefined events, managing the sensor read-out and the input triggers and producing the output triggers generated by the detected events. The IPCU can also be used to reduce the amount of the stored data. A Standard 10 Gigabit Ethernet fiber optics connection connects the IPCU module to the PC with GigEVision communication protocol.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗