Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Mercury capillary interrupter Patent

Interrupter switching device utilizing electrodes and mercury filled capillary tubes in which current flow vaporizes mercury as circuit breaker

Heckler, C. H.↗

Effects of diffusion impairment on O2 and CO2 time courses in pulmonary capillaries.

Simultaneous time courses for O2 and CO2 exchange along the capillary have been calculated for homogeneous lungs, allowing for O2-CO2 interactions, dissolved O2, and chemical reaction rates. As diffusing capacity (Dl) was reduced, the transfer of CO2 and O2 was impaired by similar amounts, in spite of the 20-fold greater diffusing capacity for CO2. The reason why CO2 is affected so much is that the slope of the content against partial pressure is so much greater in blood than tissue for this gas. Because of the shapes of their respective dissociation curves, O2 transfer was most affected at normal ventilation-perfusion ratios, whereas CO2 was most affected at high ratios. Exercise exaggerated the impairment of transfer of both gases.

Wagner, P. D.↗

High pressure pulsed capillary viscometry

An analytical and test program was conducted in order to establish the feasibility of a multichamber pulsed-capillary viscometer. The initial design incorporated a piston, ram, and seals which produced measured pulses up to 30,000 psi in the closed chamber system. Pressure pulses from one to ten milliseconds were investigated in a system volume of 1 cuin. Four test fluids: a MIL-L-7808, a 5P4E polyphenyl ether, a MIL-L-23699A, and a synthetic hydrocarbon were examined in the test pressure assembly. The pressure-viscosity coefficient and viscosity delay time were determined for the MIL-L-7808 lubricant tested.

Smith, R. L.↗

An analytical and experimental investigation of rotating, non-capillary heat pipes

An approximate theoretical model is derived for laminar film condensation on the inside of a rotating, truncated cone, and is used to predict the heat transfer performance of rotating, non-capillary heat pipes for a wide variety of parametric conditions. Experimental results are presented for water, ethyl alcohol, and freon-113 in a stainless steel heat pipe rotating to speeds of 2800 rpm. Results show that these devices can be used effectively to transfer large quantities of heat in rotating systems. Predicted results agree to within + or - 20 percent of the experimental data. Dropwise condensation, instead of film condensation, improves heat pipe performance while the presence of non-condensible gases impairs performance.

Marto, P. J.↗

Nondestructive measurement of capillary tube internal diameter

Technique provides nondestructive method of making quick, accurate determination by measuring electrical resistance of capillary tube when it is filled with electrolyte of known conductivity. Apparatus consists of conductivity cell and equipment for measuring resistance and for monitoring and controlling temperature.

Ho, W. W.↗

Buoyant and capillary natural convection in infinite horizontal liquid layers heated laterally

Solutions are presented for the equations describing natural convection in a planar, horizontal layer of liquid with a constant, linear temperature gradient along the unbounded top and bottom surfaces. Both buoyancy and capillary forces are considered to drive thermal convection. The results are compared to earlier analyses for bounded liquid layers and then applied to containerless metal melts undergoing solidification in the microgravity environment of near-earth orbit.

Bourgeois, S. V.↗

Silicon ribbon growth by a capillary action shaping technique

The technique of silicon ribbon growth by the capillary action shaping is assessed for applicability to photovoltaic power device material. Ribbons 25 mm in width and up to 0.5 m in length have been grown from SiC dies, and some new characteristics of growth from such dies have been identified. Thermal modifiers have been studied, and systems were developed which reduce the frozen-in stress un silicon ribbons and improve the thickness uniformity of the ribbons. Preliminary spreading resistance measurements indicate that neither surface striations nor twin boundaries give rise to appreciable resistivity variations, but that large-angle grain boundaries cause local resistivity increases of up to 200%.

Schwuttke, G. H.↗

On the variation and growth of wave-slope spectra in the capillary-gravity range with increasing wind

A new laser device has been used to make direct wave-slope measurements in the capillary-gravity range. Owing to the design principles, the digital nature of the system and the use of a laser beam as a probe, the earlier problems of intensity variations and meniscus effects were avoided. Using this new technique, wave-slope spectra both down and across the channel were obtained for different wind conditions, along with corresponding mean-square slope values. Comparisons are made with existing data. The results indicate that a quasi-equilibrium state may exist for each wind speed and that it increases in intensity with increasing wind, which may imply an asymptotic nature for the equilibrium-range coefficient. From the data, two significant frictional velocities, 17.5 and 31 cm/s respectively, are identified as critical values for different ranges of wave development.

Long, S. R.↗

Laser probe for measuring 2-D wave slope spectra of ocean capillary waves

A laser-optical instrument for use in determining the two-dimensional wave-slope spectrum of ocean capillary waves is described. The instrument measures up to a 35-deg tip angle of the surface normal by measuring the position of a refracted laser beam directed vertically upward through a water surface. A telescope, a continuous two-dimensional Schottky barrier photodiode, and a pair of analog dividers render the signals independent of water height and insensitive to laser-beam intensity fluctuations. Calibration is performed entirely in the laboratory before field use. Sample records and wave-slope spectra are shown for one-dimensional wave-tank tests and for two-dimensional ocean tests. These are presented along with comparison spectra for calm and choppy water conditions. A mechanical wave follower was used to adjust the instrument position in the presence of large ocean swell and tides.

Palm, C. S.↗

An improved capillary rheometer

Capillary rheometer incorporates cone-tipped preheated piston to compress plastized coal sample through narrow tube. Applied force is proportional to viscosity and is recorded on separate instrument. Samples are heated rapidly due to large area of cone surface. Device, primarily applied in designing efficient equipment for feeding coal into combustion chamber, may be readily used in other viscosity studies.

Feinstein, S. P.↗

Application of an electron beam facility for heat transfer measurements in capillary tubes

A unique method was developed for the determination of heat transfer coefficients for water flowing through capillary tubes using a rastered electron beam heater. Heat flux levels of 150 and 500 watts/sq cm were provided on the top surface of four square tubes. Temperature gradient along the tube length and mass flow rates versus pressure drop were measured.

Lunde, A. R.↗

An investigation of the modulation of capillary and short gravity waves in the open ocean

A preliminary investigation of the modulation of capillary and gravity waves by long ocean waves is described. A pressure transducer is used to obtain water surface displacements, and a high-response laser-optical system is used to detect short-wave slopes. Analytical techniques are developed to account for the orbital motion of long waves. The local mean squared wave slope is found to be maximum leeward of the long-wave crests. For the long waves studied here and for short waves from 1 cm to 1 m, the longer a short-wave component is, the more leeward its maximum tends to occur. Also, the shortest waves tend to modulate least. The modulation of short waves is found to be strong enough to be an important component of the synthetic aperture radar image formation mechanism for long ocean waves.

Evans, D. D.↗

Development of and fabrication of high resolution gas chromatographic capillary columns

Gas chromatographic columns which are used in the trace gas analyzer (TGA) for the space shuttle are coated with a polyoxyethylene lauryl ether. This stationary phase is of medium polarity and has a temperature limit of 160 C. A polymer for this application which has an improved thermal stability is investigated. The use of fused silica capillary columns with specially bonded phases as well as an introduction system (on column) was also studied.

Zlatkis, A.↗

Capillary priming characteristics of a high capacity dual passage heat pipe

A parametric study of the forces governing the liquid-vapor interface was performed for the purpose of determining the capillary priming characteristics of Grumman's dual passage monogroove heat pipe when subjected to low-g or zero-g conditions. The static liquid-vapor interface configuration was determined through minimization of the free surface energies and a mathematical model and computer program which describe the time to prime was developed. Modeling predictions confirmed expectations of proper priming action and established the criteria for sizing of the liquid and vapor channels.

Peterson, G. P.↗

Design, development and test of a capillary pump loop heat pipe

The development of a capillary pump loop (CPL) heat pipe, including computer modeling and breadboard testing, is presented. The computer model is a SINDA-type thermal analyzer, combined with a pressure analyzer, which predicts the transients of the CPL heat pipe during operation. The breadboard is an aluminum/ammonia transport system which contains multiple parallel evaporator and condenser zones within a single loop. Test results have demonstrated the practicality and reliability of such a design, including heat load sharing among evaporators, liquid inventory/temperature control feature, and priming under load. Transport capability for this system is 65 KW-M with individual evaporator pumps managing up to 1.7 KW at a heat flux of 15 W/sq cm. The prediction of the computer model for heat transport capabilities is in good agreement with experimental results.

Kroliczek, E. J.↗