The transfer of carbon fibers through a commercial aircraft water separator and air cleaner

The fraction of carbon fibers passing through a water separator and an air filter was determined in order to estimate the proportion of fibers outside a closed aircraft that are transmitted to the electronics through the air conditioning system. When both devices were used together and only fibers 3 mm or larger were considered, a transfer function of .001 was obtained.

Meyers, J. A.↗

Temperature dependence (4K to 300K) of the electrical resistivity of methane grown carbon fibers

Experimental measurements of the electrical resistivity vs temperature of methane vapor grown carbon fibers are presented. The fibers are heat treated from 1100 C (as-grown) to 3000 C. Data are fit to a standard two band model, which yields values for boundary scattering limited electron mobility, in-plane mean free path, energy band overlap, and total carrier density. The data are also fit to an ellipsoidal band model, where data fits yield effective masses, band overlap, Fermi velocity, phonon contributions to scattering, and ionized impurity scattering rates.

Woollam, John A.↗

Carbon fiber internal pressure vessels

Internal pressure vessels were designed; the filament was wound of carbon fibers and epoxy resin and tested to burst. The fibers used were Thornel 400, Thornel 75, and Hercules HTS. Additional vessels with type A fiber were made. Polymeric linears were used, and all burst testing was done at room temperature. The objective was to produce vessels with the highest attainable PbV/W efficiencies. The type A vessels showed the highest average efficiency: 2.56 x 10 to the 6th power cm. Next highest efficiency was with Thornel 400 vessels: 2.21 x 10 to the 6th power cm. These values compare favorably with efficiency values from good quality S-glass vessels, but strains averaged 0.97% or less, which is less than 1/3 the strain of S-glass vessels.

Simon, R. A.↗

An assessment of the risk arising from electrical effects associated with carbon fibers released from commercial aircraft fires

The risks associated with electrical effects arising from carbon fibers released from commercial aviation aircraft fires were estimated for 1993. The expected annual losses were estimated to be about $470 (1977 dollars) in 1993. The chances of total losses from electrical effects exceeding $100,000 (1977 dollars) in 1993 were established to be about one in ten thousand.

Kalelkar, A. S.↗

Ultrasonic inspection of carbon fiber reinforced plastic by means of sample-recognition methods

In the case of carbon fiber reinforced plastic (CFRP), it has not yet been possible to detect nonlocal defects and material degradation related to aging with the aid of nondestructive inspection method. An approach for overcoming difficulties regarding such an inspection involves an extension of the ultrasonic inspection procedure on the basis of a use of signal processing and sample recognition methods. The basic concept involved in this approach is related to the realization that the ultrasonic signal contains information regarding the medium which is not utilized in conventional ultrasonic inspection. However, the analytical study of the phyiscal processes involved is very complex. For this reason, an empirical approach is employed to make use of the information which has not been utilized before. This approach uses reference signals which can be obtained with material specimens of different quality. The implementation of these concepts for the supersonic inspection of CFRP laminates is discussed.

Bilgram, R.↗

Carbon fiber behavior in an enclosed volume

Tests were performed to evaluate the behavior of single carbon fibers existing in an enclosed space such as a room of a building. Three general phenomena were explored: the concentration decay rate of a fiber-charged room, the degree of uniform mixing of fibers within a room, and the effects of fibers being redisseminated off deposition surfaces within a room. The results were required in understanding the ratio of total indoor fiber exposure to total outdoor fiber exposure, a quantity essential to risk analysis. Results indicate that decay rate is predictable within acceptable limits and that homogeneous mixing can always be assumed. Some factors of redissemination are identified and effects discussed.

Harvey, M. C.↗

Assessment of the risk due to release of carbon fiber in civil aircraft accidents, phase 2

The risk associated with the potential use of carbon fiber composite material in commercial jet aircraft is investigated. A simulation model developed to generate risk profiles for several airports is described. The risk profiles show the probability that the cost due to accidents in any year exceeds a given amount. The computer model simulates aircraft accidents with fire, release of fibers, their downwind transport and infiltration of buildings, equipment failures, and resulting ecomomic impact. The individual airport results were combined to yield the national risk profile.

Pocinki, L.↗

Vapor grown carbon fiber for space thermal management systems

Research that uses a novel, highly graphitic, vapor grown carbon fiber (VGCF) to fabricate composites for thermal management applications is described. These VGCF/Carbon composites have shown a specific thermal conductivity with values of twenty-to-ten times that of copper in the 500-900 K temperature range needed for waste heat management. It is concluded that development of this high specific thermal conductivity composite for thermal radiator panels will provide the foundation for a reevaluation of space power designs heretofore limited by the mass of waste heat dissipation systems. Further, it is suggested that through optimization of fiber handling and composite processing, thermal conductivities exceeding 1000 W/m-K (at 300 K) are achievable in composites reinforced with VGCF.

Lake, Max L.↗

Thermal Fault Tolerance Analysis of Carbon Fiber Rope Barrier Systems for Use in the Reusable Solid Rocket Motor ( RSRM) Nozzle Joints

Carbon Fiber Rope (CFR) thermal barrier systems are being considered for use in several RSRM (Reusable Solid Rocket Motor) nozzle joints as a replacement for the current assembly gap close-out process/design. This study provides for development and test verification of analysis methods used for flow-thermal modeling of a CFR thermal barrier subject to fault conditions such as rope combustion gas blow-by and CFR splice failure. Global model development is based on a 1-D (one dimensional) transient volume filling approach where the flow conditions are calculated as a function of internal 'pipe' and porous media 'Darcy' flow correlations. Combustion gas flow rates are calculated for the CFR on a per-linear inch basis and solved simultaneously with a detailed thermal-gas dynamic model of a local region of gas blow by (or splice fault). Effects of gas compressibility, friction and heat transfer are accounted for the model. Computational Fluid Dynamic (CFD) solutions of the fault regions are used to characterize the local flow field, quantify the amount of free jet spreading and assist in the determination of impingement film coefficients on the nozzle housings. Gas to wall heat transfer is simulated by a large thermal finite element grid of the local structure. The employed numerical technique loosely couples the FE (Finite Element) solution with the gas dynamics solution of the faulted region. All free constants that appear in the governing equations are calibrated by hot fire sub-scale test. The calibrated model is used to make flight predictions using motor aft end environments and timelines. Model results indicate that CFR barrier systems provide a near 'vented joint' style of pressurization. Hypothetical fault conditions considered in this study (blow by, splice defect) are relatively benign in terms of overall heating to nozzle metal housing structures.

Clayton, J. Louie↗

Evaluation of the Anisotropic Radiative Conductivity of a Low-Density Carbon Fiber Material from Realistic Microscale Imaging

The radiative heat transfer inside a low-density carbon fiber insulator is analyzed using a three-dimensional direct simulation model. A robust procedure is presented for the numerical calculation of the geometric configuration factor to compute the radiative energy exchange processes among the small discretized surface areas of the fibrous material. The methodology is applied to a polygonal mesh of a fibrous insulator obtained from three-dimensional microscale imaging of the real material. The anisotropic values of the radiative conductivity are calculated for that geometry. The results yield both directional and thermal dependence of the radiative conductivity.

Evaluation↗

The effects of matrix and interface modification on local fractures of carbon fibers in epoxy.

This paper examines the fracture mechanisms which occur in the matrix and interfacial region surrounding a fiber when the fiber fails under axial load. Both tensile and compressive behavior of carbon fibers in an epoxy-novolac system are treated for specimens having very low fiber concentrations. First, the fracture mechanisms are isolated and identified and then means for controlling the propagation or containment of fiber fractures are explored. Sequences of photographs showing progressive damage with increasing load are presented for each loading condition. Effects of fiber orientation are also treated.

Mullin, J. V.↗

Electron-spin-resonance studies of vapor-grown carbon fibers

The effects of annealing temperature and fiber diameter on the degree of disorder of vapor-grown carbon fibers were investigated by analyzing the electron-spin-resonance (ESR) line shapes of fibers annealed at six various temperatures up to 3375 K. The diameter of fibers, grown from methane gas, ranged from 10 to 140 microns with most fibers between 20 and 50 microns. It was found that the degree of disorder of vapor-grown fibers decreases upon annealing to higher temperature; standard angular deviation between the fiber axis and the crystallite basal planes could vary from 35 deg (for annealing temperature of 2275 K) to 12 deg (for 3375 K). With respect to fiber diameter, order parameters were found to be higher for fibers of smaller diameters.

Marshik, B.↗

Negative magnetoresistance of pitch-based carbon fibers Temperature and pressure dependence

The negative transverse magnetoresistance of high-modulus pitch-based carbon fibers has been measured over the temperature range 1.3-4.2 K at ambient pressure and at 4.2 K under hydrostatic pressure up to 16 kbar. At low fields (less than 0.5 torr) the magnitude of the magnetoresistance increases markedly as the temperature is lowered from 4.2 K to 1.3 K, in disagreement with Bright's theoretical model, and decreases with pressure at the rate -0.6 percent/kbar.

Hambourger, P. D.↗

Graphite Sheet Coating for Improved Thermal Oxidative Stability of Carbon Fiber Reinforced/PMR-15 Composites

Expanded graphite was compressed into graphite sheets and used as a coating for carbon fiber reinforced PMR-15 composites. BET analysis of the graphite indicated an increase in graphite pore size on compression, however the material was proven to be an effective barrier to oxygen when prepegged with PMR-15 resin. Oxygen permeability of the PMR-15/graphite was an order of magnitude lower than the compressed graphite sheet. By providing a barrier to oxygen permeation, the rate of oxidative degradation of PMR-15 was decreased. As a result, the composite thermo-oxidative stability increased by up to 25%. The addition of a graphite sheet as a top ply on the composites yielded little change in the material's flexural strength or interlaminar shear strength.

Campbell, Sandi↗

Investigation of Carbon Fiber Architecture in Braided Composites Using X-Ray CT Inspection

During the fabrication of braided carbon fiber composite materials, process variations occur which affect the fiber architecture. Quantitative measurements of local and global fiber architecture variations are needed to determine the potential effect of process variations on mechanical properties of the cured composite. Although non-destructive inspection via X-ray CT imaging is a promising approach, difficulties in quantitative analysis of the data arise due to the similar densities of the material constituents. In an effort to gain more quantitative information about features related to fiber architecture, methods have been explored to improve the details that can be captured by X-ray CT imaging. Metal-coated fibers and thin veils are used as inserts to extract detailed information about fiber orientations and inter-ply behavior from X-ray CT images.

braided composites↗

Diamagnetic studies on as-processed carbon fibers

The Faraday method has been used to measure the diamagnetic susceptibilities of small bundles of aligned carbon fibers of different types at room temperature. It was found that the tensor trace susceptibility of the fibers varies systematically over the range 0.8-20 (in units of -10 to the -6th emu/g) as a function of precursor type and processing history. The susceptibility increases, in general, with increasing nominal treatment temperature and hot stretching, and with increasing tensile elastic modulus. The anisotropy ratio of fibers increases approximately linearly with tensile elastic modulus for all fibers from about 1 for a modulus of about 70 GN/sq m to about 22 for a modulus of 700 GN/sq m in air, and is quantitatively consistent with the layer-plane orientation textures determined by X-ray diffraction when appropriate values of the crystallite principal susceptibilities are used.