Search NASA⌕ Search

SEARCH · Search NASA

Results for “carbonate solvent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Transition Metal Dissolution in Lithium-Ion Cells: A Piece of the Puzzle

Static leaching tests were performed using the chemically delithiated positive electrode materials, LiFePO 4 , LiCoO 2 , LiMn 2 O 4 , LiNiO 2 , and LiNi 0.8 Mn 0.1 Co 0.1 O 2 . Instead of the common electrolyte, which contains LiPF 6 , the solvent consisted of only ethylene carbonate (EC) and ethyl methyl carbonate (EMC), limiting the possible reactions to only those that depend on the solvent. The product liquids from these experiments showed that there were lithium-bearing species in common, such as Li(EC) + and Li(EMC) + . Interestingly, we found evidence of electrolyte degradation products in both the positive-and negative-ion mass spectral results. The positive-ion results showed that the products tended to coordinate to lithium. In conclusion, the negative-ion results showed that most of the products tended to complex with transition metals. It was difficult to discern which positive ion was associated with which negative ion.

25 ENERGY STORAGE↗

Gating ion and fluid transport with chiral solvent

Nonlinear spectroscopy and electrokinetic measurements reveal that the electrochemical properties of a solid–liquid interface in salt solutions in propylene carbonate are dependent on the solvent chirality.

Chemistry↗

NMR and Theoretical Study of In-Pore Diffusivity of Ionic Liquid–Solvent Mixtures

We report despite having a lower energy density than common batteries, electric double-layer capacitors (EDLCs) offer several advantages for high-power applications, including high power density, quick charge and discharge time, and long cycle life. Room-temperature ionic liquids (RTILs) have been intensely studied as promising electrolytes for applications in ELDCs because of their wide potential window, low volatility, as well as thermal and chemical stability. The main deficiency of neat RTILs in such applications is the sluggish diffusivity, which restricts the EDLCs’ power density. To alleviate the slow diffusivity, RTILs can be used in a mixture with organic solvents. In this study, we applied two-dimensional exchange nuclear magnetic resonance spectroscopy (2D EXSY NMR) and molecular dynamics (MD) simulations to investigate the diffusivity of anions of an RTIL, namely, 1-butyl-3-methyl-imidazolium bis(trifluoromethylsulfonyl)imide (BMIM + –TFSI – ), dissolved in five different organic solvents, in the micropores of activated carbon. We determined that the relative concentrations of ions in solutions in the micropores were higher than those in the bulk solutions and were also solvent-dependent. The ion diffusivities in the pores were found to be almost 2 orders of magnitude slower than in the bulk solutions, with methanol showing the largest relative disparity. These results suggested that the interactions of solvents with the activated carbon are critical not only to the power density of EDLCs but also to the energy density. The comparisons of ion diffusivities between the experiments and the MD simulations suggest the need to consider also the surface functionalities of activated carbon for the simulation of ion diffusion in the micropores of activated carbon.

electric double layer capacitors↗

Tailoring Chemical Absorption-Precipitation to Lower the Regeneration Energy of a CO 2 Capture Solvent

Solvent-based CO 2 capture consumes significant amounts of energy for solvent regeneration. To improve energy efficiency, this study investigates CO 2 fixation in a solid form through solvation, followed by ionic self-assembly-aided precipitation. Based on the hypothesis that CO 3 2- ions may bind with monovalent metal ions, we introduced Na + into an aqueous hexane-1,6-diamine solution where CO 2 forms carbamate and bicarbonate. Then, Na + ions in the solvent act as a seed for ionic self-assembly with diamine carbamate to form an intermediate ionic complex. The recurring chemical reactions lead to the formation of an ionic solid from a mixture of organic carbamate/carbonate and inorganic sodium bicarbonate (NaHCO 3 ), which can be easily removed from the aqueous solvent through sedimentation or centrifugation and heated to release the captured CO 2 . Mild-temperature heating of the solids at 80–150 °C causes decomposition of the solid CO 2 -diamine-Na molecular aggregates and discharge of CO 2 . This sorbent regeneration process requires 6.5–8.6 GJ/t CO 2 . It was also found that the organic carbamate/carbonate solid, without NaHCO 3 , contains a significant amount of CO 2 , up to 6.2 mmol CO 2 /g-sorbent, requiring as low as 2.9–5.8 GJ/t CO 2 . In conclusion, molecular dynamic simulations support the hypothesis of using Na + to form relatively less stable, yet sufficiently solid, complexes for the least energy-intensive recovery of diamine solvents compared to bivalent carbonate–forming ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Concepts for Actinide Recovery from TRISO Used Nuclear Fuel

The work described in this report has developed a preliminary conceptual flowsheet based on limited published literature for the head-end of a TRISO oxycarbide UNF reprocessing plant. The essential function of the head-end is to prepare the UNF for subsequent separation of actinides. The main steps of the conceptual TRISO UNF head-end reprocessing flowsheet are: 1. Fragmentation of the graphite moderator to expose the fuel particles. 2. Separation of fuel particles from fragmented graphite moderator by sieving and fluidization. 3. Fragmentation of the fuel particles to expose the fuel kernel. 4. Dissolution of the fuel kernel in nitric acid. Noteworthy at this step is the formation of organic acids (mainly oxalic and mellitic acids) from the carbon associated with the fuel and TRISO coatings. These acids can interfere with actinide separations and solvent extraction hydraulic performance and carbon dioxide gas generation. 5. Clarification of the dissolved fuel solution to separate the coating fragments. 6. Dissolver off-gas treatment with specific emphasis on managing generation of carbon dioxide gas containing carbon-14. The quantity of carbon dioxide is projected to be 100 to 1000 times greater than that arising from dissolving LWR UNF. Pre or post treatment of the exposed fuel kernels could be undertaken to mitigate the formation of organic acids but there still exists a significant off-gas treatment challenge. The literature on reprocessing uranium nitride UNF was reviewed but a flowsheet was not specifically developed since its scope and uncertainties are expected to be encompassed by the oxycarbide flowsheet. Overall, the predominant feature of processing TRISO UNF is carbon management to reduce waste volume and mitigate the formation of carbon dioxide and organic acids. This report recommends broad areas of research that will help to further define the head-end flowsheet.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The influence of random packed column parameters on the liquid holdup and interfacial area

Abstract Carbon dioxide capture via solvent absorption in packed columns has emerged as a potential technology to mitigate coal‐fired power plant CO 2 emissions. Parameters, including packing types, solvent properties, and operating conditions, could potentially affect the packed column CO 2 capture efficiency. To understand the importance of those parameters and help packed column optimization, a design of experiments (DoEs) method was proposed to generate input parameter matrix. Combined with multiphase computational fluid dynamics (CFD), the random packed column parameter influence on the liquid holdup and interfacial area can be efficiently investigated. Surrogate‐based sensitivity analysis shows that the solvent flow rate and contact angle are key factors dictating liquid holdup and interfacial area. On the other hand, solvent viscosity has a marginal impact on the interfacial area. The sensitivity scores were calculated for each input parameter to guide the selection of dimensionless numbers for the liquid holdup and interfacial area correlation development.

42 ENGINEERING↗

Mesoporous silica-encapsulated gold core–shell nanoparticles for active solvent-free benzyl alcohol oxidation

Silica-encapsulated gold core@shell nanoparticles (Au@SiO2 CSNPs) were synthesized via a bottom-up procedure and used to catalyze the selective oxidation of benzyl alcohol. The pore size, morphology, crystallinity and composition of Au@SiO2 was evaluated using non-local density functional theory, transmission electron microscopy, high-energy x-ray diffraction and inductively coupled plasma-mass spectroscopy, respectively. The nanoparticles exhibit a mesoporous shell with an average thickness of 25.5 Å which can enhance selectivity via preferential transport of the desired product (i.e., benzaldehyde) relative to larger, undesired products (i.e, benzoic acid/benzyl benzoate). GC-FID analysis revealed the addition of potassium carbonate to the solvent-free oxidation of benzyl alcohol increased conversion from 17.3 to 60.4% while decreasing selectivity from 98.7 to 75.0%. Under equivalent conditions, a bare gold nanoparticle control catalyst deposited on a silica support with a similar gold surface area took 6 times as long to reach the same conversion, achieving only 49.4% selectivity. These results suggest that the pore size distribution within the inert silica shell of Au@SiO2 CSNPs inhibits the formation of undesired products to facilitate the selective oxidation of benzaldehyde despite a basic environment, which reduces selectivity under typical conditions. The CSNPs demonstrated a much lower activation energy than the Au-SiO2 control catalyst, 37 ± 1.9 kJ/mol and 72 ± 7.1 kJ/mol, respectively. Thiele modulus analysis indicates the CSNP pore structure does not create a mass transport limitation due to the nano-scale path of diffusion through the pore structure to the active surface. The lower activation energy and mesopore distribution together suggest the Au@SiO2 catalyst demonstrates higher activity through beneficial in-pore orientation, both reducing competitive adsorption and promoting a single, lower activation energy mechanistic pathway.

benzyl alcohol oxidation, catalysis, confinement↗

Terminally fluorinated glycol ether electrolyte for lithium metal batteries

Despite being an excellent candidate for lithium metal batteries due to its stability towards lithium metal, ethereal solvent suffers from relatively low anodic stability, rendering it incompatible with high voltage cathode. Although the anodic stability of ethereal solvent can be enhanced by fluorination, the lithium solvating ability of fluorinated ethers is largely reduced. As a result, common hydrofluoroethers, such as 1,1,2,2-tetrafluoroethyl-2,2,3,3-tetrafluoropropylether (TTE) and bis(2,2,2-trifluoroethyl) ether (BTFE) are not able to dissolve any lithium salt, albeit enhanced oxidation potential. Therefore, new fluorinated glycol ethers were synthesized in this research. The diglyme analog, which was terminally fluorinated, demonstrated high anodic stability and excellent capability to facilitate lithium plating/stripping. Unlike its non-fluorinated counterpart, the fluorinated diglyme analog displayed outstanding compatibility with lithium hexafluorophosphate, which is an essential salt in lithium-ion batteries. Here it was shown that the electrolyte based on fluorinated diglyme analog with fluoroethylene carbonate as co-solvent enabled highly stable cycling of Li-metal batteries pairing with layered oxide cathode.

25 ENERGY STORAGE↗

Examination of Solvent- Room Temperature Ionic Liquid Interactions using 2D NMR and Computational Chemistry

Rare earth metals (REMs) are the key functioning material found in microelectronics, advanced batteries, and high-efficiency electrical motors. Current methods for producing REMs require high temperatures (i.e. energy intensive) and produce an abundance of hazardous fluoride waste. Room temperature ionic liquids (RTILs) are an ideal alternative electrolyte because they allow for a low-temperature, energy-efficient electrochemical process. RTIL properties such as viscosity and conductivity determine how effective they can be in this process. Since viscosity is directly related to both intra and intermolecular forces, this study sets out to investigate two RTILs-Trihexyltetradecylphosphonium dicyanamide (Cyphos 105) and Trihexyltetradecylphosphonium bistrifimide (Cyphos 109) and their interactions. Results from 2-dimensional nuclear magnetic resonance (2D NMR) spectroscopy show that there is an interaction between the tetradecyl tail and the phosphorus atom of the Cyphos RTIL. In order to establish whether this is an intra or an inter-molecular interaction, DFT-based computational calculations were performed to determine the optimized geometry. Calculations were done both in the gas phase and with propylene carbonate as an augmenting solvent. Preliminary results show that there is minimal intramolecular interaction between the tetradecyl tail and the phosphorus atom of the RTILs, and that the interaction seen in the 2D NMR experiment is likely of an intermolecular nature instead.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Particulate from Lignite Coal Combustion and Impact on Carbon Capture Aerosol Emissions

Conference presentation for 47th International Technical Conference on Clean Energy (Clearwater Clean Energy Conference), Clearwater, Florida, July 23–27, 2023. While aerosol formation is recognized as a leading cause of amine losses and degradation from postcombustion CO 2 capture systems, the factors that can lead to aerosol formation vary widely depending on fuel type, plant configuration, and operating conditions. All of these factors require measurement to fully characterize potential sources of aerosol-based amine losses and should be considered prior to implementing full-scale amine-based CO 2 capture.

01 COAL, LIGNITE, AND PEAT↗

Examining the Reactions of Ethanolamine’s Thermal Degradation Compounds in Carbon Capture through 1 H NMR and 13 C NMR

In amine scrubbing carbon capture, concerns about amine solvent degradation include whether it can affect the ability of the solvent to capture CO 2 . This study examines the interactions between the three most reported monoethanolamine (MEA) thermal degradation compounds namely, oxazolidine-2-one (OZD), N-(2-hydroxyethyl)-ethylenediamine (HEEDA), and N-(2- hydroxyethyl)-imidazoline-2-one (HEIA) with CO 2 in the presence and absence of MEA. We compared 1 H NMR, 13 C NMR, and heteronuclear single-quantum coherence (HSQC) NMR for neat OZD, HEEDA, and HEIA samples with CO 2 -loaded samples to observe changes in protonation and unique carbamate species formation. We found that OZD and HEIA did not directly react with CO 2 or undergo proton shifting based on our comparison of the neat OZD and HEIA samples with CO 2 -loaded spectra. However, we observed that the OZD can protonate when sparged with CO 2 in the presence of MEA, which suggests that the OZD acts as an intermediate. The NMR spectra for HEEDA indicated that HEEDA directly reacts with CO 2 at both amino groups and can protonate. In the presence of MEA, HEEDA and MEA can act like a solvent blend, resulting in multiple carbamates forming within the solvent. The neat HEIA spectrum, compared with CO 2 -loaded HEIA spectra, revealed similar results as OZD, where it does not react with CO 2 or protonate directly. However, HEIA does not protonate in the presence of MEA. These degradation compound reactions can increase the number of general equilibrium reactions during carbon capture and impact the model MEA solvent. This work helps provide a more complete picture of the reactions as the solvent degrades. Although this study examines CO 2 effects on thermal degradation products for MEA, other amines such as piperazine or 1- amino-3-propanol will degrade, and the degradation may speciate similarly with CO 2 . Furthermore, this study can impact and improve process models by assessing the degradation compounds’ reactions with CO 2 and potentially incorporating them into the model based on a neat solvent.

20 FOSSIL-FUELED POWER PLANTS↗

Communication — The Impact of Co-solvent Selection for Dimethyl-2,5-dioxahexane carboxylate in Sodium Ion Batteries

Traditional linear carbonates including dimethyl carbonate (DMC), diethyl carbonate (DEC), and ethyl methyl carbonate (EMC) were investigated as co-solvents for the dimethyl-2,5-dioxahexane carboxylate (DMOHC)-based electrolyte in Na 0.97 Ca 0.03 [Mn 0.39 Fe 0.31 Ni 0.22 Zn 0.08 ]O 2 (NCMFNZO)/hard carbon (HC) pouch cells. The EMC-containing cell displays excellent electrochemical performance, exhibiting only a 1.6 mAh irreversible capacity loss during 500 h of storage at 4 V and 40 °C, and maintaining over 80% capacity retention after 200 cycles up to 4 V at 40 °C. Severe gas evolution and Na plating issues are present in all the tested systems.

25 ENERGY STORAGE↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗

Assessing the Effect of Explicit Polarizability on Models of Carbon Dioxide Solvation in Ionic Liquids

Ionic liquids are an important possible carbon capture material because of their anomalously high sorption selectivity for carbon dioxide over other gases common in air. Many research groups have investigated the molecular origins of this property and provided important insights, including using 1D and 2D-IR spectroscopy. Molecular dynamics simulations have been indispensable to the interpretation of these experiments. In prior molecular dynamics simulation work, charge-scaled force fields have typically been used to provide a mean-field treatment of effects vital to ionic liquid systems such as charge transfer and polarization. Here, we compare models of carbon dioxide solvated in ionic liquids with explicit polarization to models of the same with implicit polarizability through charge-scaling. We calculate structural, dynamical, and spectroscopic properties, and make comparisons to the same items measured in experiment. In this study, we focus on two ionic liquids: 1-butyl-3- methylimidazolium (BMIM + ) paired with bis(trifluoromethane sulfonyl imide) (Tf 2 N − ) and 1-butyl-3-methylimidazolium (BMIM+) paired with hexafluorophosphate (PF 6 − ). We find that many structural, dynamical, and spectroscopic properties are changed when polarization is modeled explicitly. We also find that explicit polarizability softens local ion cages around the carbon dioxide and that the long-time diffusion of the carbon dioxide is gated by the reorganization of the ionic liquid molecules. Comparisons to experiment show modest improvement of many observables compared with experiment for the explicitly polarizable model over the charge-scaled model. Overall, our results show that charge-scaled force fields are likely sufficient to compute spectroscopic properties of carbon dioxide in ionic liquids and suggest some interpretive rules for understanding their structural and dynamical properties. Those using charge-scaled force fields should generally assume that the ion cages around solutes such as carbon dioxide are too stiff and cation-rich in their models and adjust their interpretations and predictions accordingly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lithium oxidation and electrolyte decomposition at Li-metal/liquid electrolyte interfaces

In this work, we examine the evolution of events occurring when a Li metal surface is in contact with a 2 M solution of a Li salt in a solvent or mixture of solvents, via classical molecular dynamics simulations with a reactive force field allowing bond breaking and bond forming. The main events include Li oxidation and electrolyte reduction along with expansion of the Li surface layers forming a porous phase that is the basis for the formation of the solid-electrolyte interphase (SEI) components. Nucleation of the main SEI components (LiF, Li oxides, and some organics) is characterized. The analysis clearly reveals the details of these physical–chemical events as a function of time, during 20 nanoseconds. The effects of the chemistry of the electrolyte on Li oxidation and dissolution in the liquid electrolyte, and SEI nucleation and structure are identified by testing two salts: LiPF 6 and LiCF 3 SO 3 , and various solvents including ethers and carbonates and mixtures of them. The kinetics and thermodynamics of Li 6 F, the core nuclei in the LiF crystal, are studied by analysis of the MD trajectories, and via density functional theory calculations respectively. The SEI formed in this computational experiment is the “native” film that would form upon contact of the Li foil with the liquid electrolyte. As such, this work is the first in a series of computational experiments that will help elucidate the intricate interphase layer formed during battery cycling using metal anodes.

25 ENERGY STORAGE↗

Effects of Ink Formulation on the Structure and Performance of PGM-Free Catalyst Layer in PEMFCs

Platinum group metal (PGM) catalysts are the major electrocatalysts for oxygen reduction reaction (ORR) in the polymer electrolyte membrane fuel cells (PEMFCs). The cost becomes unaffordable if the PEMFC is in massive application. The PGM-Free catalyst shows very promising activity in rotation disk electrode (RDE) testing. The half-wave potential could reach 0.91 V versus standard hydrogen electrode (SHE). However, in a membrane electrode assembly (MEA), the performance of PGM-Free catalysts is not good enough to replace the PGM catalysts. Since the PGM-free catalysts are so different from the PGM catalysts in terms of catalytic activity, stability, surface conditions, particle size, etc., the fabrication of PGM-Free catalyst MEA cannot simply copy the method of making PGM MEA. Here we proposed a novel method of fabricating PGM-Free catalyst MEA, so that the intrinsic catalyst activity from RDE can be translated into MEA performance. The method is based on the catalyst coated membrane (CCM) method using optimized ionomer to carbon (I/C) ratio and solvent mixture of catalyst ink. Using this method, the PGM-free catalyst MEA achieved the current density 44.9 mA cm -2 at 0.9 V iR-free in H 2 /O 2 and 150 mA cm -2 at 0.8 V in H 2 /air, which surpassed the performance targets of US Department of Energy (DOE)for PGM-Free catalyst MEA. The property (solvent composition, dispersion of catalyst and ionomer in an ink), structure (pore structure) and the MEA performance have been characterized using, mercury intrusion porosimetry (MIP), MEA testing. A property-structure-performance relationship has been established.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗

Slipstream Testing of Amine-Based Solvents at a Low-Rank Coal-Fired Power Plant

Conference presentation for 38th Annual International Pittsburgh Coal Conference, Virtual, September 20–23, 2021. To better assess mitigation strategies for aerosol reduction to extend solvent life, the University of North Dakota Energy & Environmental Research Center (EERC) installed a pilot-scale CO 2 absorption system at a lignite-fired plant in central North Dakota. The pilot-scale system was operated using both commercial KS-1™ solvent and advanced KS-21™ solvent provided by Mitsubishi Heavy Industries (MHI). MHI’s proprietary amine emission reduction unit (AERU™) technology was installed downstream of the absorber columns to reduce solvent losses by recovering amines at the system outlet. Fine particulate loading was measured throughout the capture system with and without a WESP operating and using both solvents. Captured particulate was brought back to the EERC to be analyzed for chemical composition and to be examined by scanning electron microscopy for particulate structure. These variables were then correlated to performance of particulate control devices in reducing aerosol formation and solvent losses.

01 COAL, LIGNITE, AND PEAT↗