The Impact of a Faster Thermal Cycling Profile on PV Cell Interconnect Cycles to Failure

The thermal cycling tests used in the photovoltaic industry are slow, requiring over a month for 200 cycles and five months for 800 cycles. A faster alternative would reduce the cost of delay for module qualification. This study investigates the correlation between a baseline thermal cycling profile and profiles that are three and six times faster. Interconnect failure data for each profile was gathered across eight splits of varying material combinations. Models were applied to the failure data and factors which impacted interconnect lifetime were identified. Here, the results show that more cycles were required in the faster profiles for equivalency to the baseline profile. Furthermore, the equivalent number of cycles varied by a factor of two across the splits. Despite these limitations, the faster profiles offer substantial qualification time savings if the underlying failure mechanisms are understood.

14 SOLAR ENERGY↗

Unlocking Failure Mechanisms and Improvement of Practical Li–S Pouch Cells through In Operando Pressure Study

For Lithium-sulfur (Li-S) battery commercialization, the study at a pouch cell level is essential, as some problems ignored or deemed minimal at the smaller level could have a greater effect on the performance of the larger pouch cell. Herein, the failure mechanisms of Li-S pouch cells are deeply investigated via in operando pressure analysis. It is found that highly porous structures of cathodes/separators and slow electrolyte diffusion through cathodes/separators can both lead to poor initial wetting. Additionally, Li-metal anode dominates the thickness variation of the whole pouch cell, which is verified by in situ measured pressure variation. Consequently, a real-time approach that combined normalized pressure with dP/dV analysis is proposed and validated to diagnose the morphology evolution of Li-metal anode. Moreover, applied pressure and porosity/tortuosity ratio of the cathode are both identified as independent factors that influence anode performance. In addition to stabilizing anodes, high pressure is proven to improve the cathode connectivity and avoid cathode cracking over cycling, which improves the possibility of developing cathodes with high sulfur mass loading. Here, this work provides insights into Li-S pouch cell design (e.g., cathode and separator) and highlights pathways to improve cell capacity and cycling performance with applied and monitored pressure.

25 ENERGY STORAGE↗

The Impact of Preradiation Residual Disease Volume on Time to Locoregional Failure in Cutaneous Merkel Cell Carcinoma—A TROG Substudy

Purpose: This study evaluated the impact of margin status and gross residual disease in patients treated with chemoradiation therapy for high-risk stage I and II Merkel cell cancer (MCC). Methods and Materials: Data were pooled from 3 prospective trials in which patients were treated with 50 Gy in 25 fractions to the primary lesion and draining lymph nodes and 2 schedules of carboplatin based chemotherapy. Time to locoregional failure was analyzed according to the burden of disease at the time of radiation therapy, comparing patients with negative margins, involved margins, or macroscopic disease. Results: Analysis was performed on 88 patients, of whom 9 had microscopically positive resection margins and 26 had macroscopic residual disease. The majority of gross disease was confined to nodal regions. The 5-year time to locoregional failure, time to distant failure, time to progression, and disease-specific survival rates for the whole group were 73%, 69%, 62%, and 66% respectively. The hazard ratio for macroscopic disease at the primary site or the nodes was 1.25 (95% confidence interval 0.57-2.77), P=.58. Conclusions: No statistically significant differences in time to locoregional failure were identified between patients with negative margins and those with microscopic or gross residual disease. These results must, however, be interpreted with caution because of the limited sample size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Decoupling Failure Pathways in Li-O 2 Cells Operated Under Lean Electrolyte Conditions

The operation of lithium-oxygen (Li-O 2 ) batteries under lean electrolyte conditions offers higher energy density but leads to rapid degradation and short cycle life. Although cathode passivation and electrolyte decomposition occur in all regimes, we show that under lean electrolyte conditions, failure is primarily driven by progressive electrolyte consumption at the lithium/solid electrolyte interphase (SEI), rather than by irreversible cathode passivation. Poor wetting of the lithium surface results in heterogeneous SEI growth and high local current densities, which accelerate electrolyte loss and cell failure. Strategies aimed at improving interfacial stability, including optimized wetting and SEI forming additives, significantly extend cycle life without compromising energy density. Our results establish anode-electrolyte interactions as the dominant degradation mechanism under lean electrolyte conditions, and emphasize the need to engineer a stable Li/SEI interface for long-lasting Li-O 2 batteries.

Córdoba, Daniel [Argonne National Laboratory (ANL)↗

High-g shock test results of Tadiran TLM-1530MP cells.

In April of 2009, testing was done of a high-g instrumentation device that utilized Tadiran TLM-1530MP cells as a power source. As a result of that testing, it was determined that those cells exhibit failure more often when shocked in the axial direction. No failures over many tests where found when the cells were shocked laterally. Moreover, when shocked laterally, the cells exhibited no observable degradation in performance. We looked at the failed cells via non-destructive x-ray analysis to determine what internal structures failed.

25 ENERGY STORAGE↗

The deformation and failure response of closed-cell PMDI foams subjected to dynamic impact loading

The present work aims to investigate the bulk deformation and failure response of closed-cell Polymeric Methylene Diphenyl Diisocyanate (PMDI) foams subjected to dynamic impact loading. First, foam specimens of different initial densities are examined and characterized in quasi-static loading conditions, where the deformation behavior of the samples is quantified in terms of the compressive elastic modulus and effective plastic Poisson's ratio. Then, the deformation response of the foam specimens subjected to direct impact loading is examined by taking into account the effects of material compressibility and inertia stresses developed during deformation, using high speed imaging in conjunction with 3D digital image correlation. The stress-strain response and the energy absorption as a function of strain rate and initial density are presented and the bulk failure mechanisms are discussed. As a result, it is observed that the initial density of the foam and the applied strain rates have a substantial influence on the strength, bulk failure mechanism and the energy dissipation characteristics of the foam specimens.

36 MATERIALS SCIENCE↗

Reliability analysis of Skylab ATM solar cell modules

A detailed reliability analysis was performed on both types of Skylab Apollo telescope mount solar cell modules. Failure rates used were based on testing of several modules of each type for over 4000 thermal cycles. The analysis delineated several important differences between the failure modes of the two differently designed solar cell modules, and, more importantly, showed that the modules can be expected to meet all mission requirements.

Jones, G. M.↗

Development of failure model for nickel cadmium cells

The development of a method for the life prediction of nickel cadmium cells is discussed. The approach described involves acquiring an understanding of the mechanisms of degradation and failure and at the same time developing nondestructive evaluation techniques for the nickel cadmium cells. The development of a statistical failure model which will describe the mechanisms of degradation and failure is outlined.

Gupta, A.↗

Light Weight Design Nickel-Alkaline Cells Using Fiber Electrodes

Using fiber electrode technology, currently produced by Bekaert Corporation (Bekaert), Electro Energy, Inc., (EEI) Mobile Energy Products Group (formerly, Eagle-Picher Technologies, LLC., Power Systems Department) in Colorado Springs, CO has demonstrated that it is feasible to manufacture flight weight nickel-hydrogen cells having about twice the specific energy (80 vs. 40 watt-hr/kg) as state-of-the-art nickel-hydrogen cells that are flown on geosynchronous communications satellites. Although lithium-ion battery technology has made large in-roads to replace the nickel-alkaline technology (nickel-cadmium, nickel-metal hydride), the technology offered here competes with lithium-ion weight and offers alternatives not present in the lithium-ion chemistry such as ability to undergo continuous overcharge, reversal on discharge and sustain rate capability sufficient to start automotive and aircraft engines at subzero temperatures. In development to date seven 50 ampere-hour nickel-hydrogen have been constructed, acceptance tested and briefly tested in a low earth orbit (LEO) cycle regime. The effort was jointly funded by Electro Energy, Inc. and NASA Glenn Research Center, Cleveland, OH. Five of the seven cells have been shipped to NASA GRC for further cycle testing. Two of the cells experienced failure due to internal short circuits during initial cycle testing at EEL Destructive Physical Analysis (DPA) of one of the cells has shown the failure mode to be due to inadequate hydrogen catalyst electrodes that were not capacity balanced with the higher energy density nickel oxide electrodes. In the investigators opinion, rebuild of the cells using proper electrode balance would result in cells that could sustain over 30,000 cycles at moderate depths-of-discharge in a LEO regime or endure over 20 years of geosynchronous orbit (GEO) cycling while realizing a two-fold increase in specific energy for the battery or a 1.1 kg weight savings per 50 ampere-hour cell. Additional information is included in the original extended abstract.

Pickett, David F.↗

Unlocking Failure Mechanisms and Improvement of Practical Li-S Pouch Cells Through in Operando Pressure Study

For Lithium-sulfur (Li-S) battery commercialization, the study at a pouch cell level is essential, as some problems ignored or deemed minimal at the smaller level could have a greater effect on the performance of the larger pouch cell. Herein, the failure mechanisms of Li-S pouch cells are deeply investigated via in operando pressure analysis. It is found that highly porous structures of cathodes/separators and slow electrolyte diffusion through cathodes/separators can both lead to poor initial wetting. Additionally, Li-metal anode dominates the thickness variation of the whole pouch cell, which is verified by in situ measured pressure variation. Consequently, a real-time approach that combined normalized pressure with dP/dV analysis is proposed and validated to diagnose the morphology evolution of Li-metal anode. Moreover, applied pressure and porosity/tortuosity ratio of the cathode are both identified as independent factors that influence anode performance. In addition to stabilizing anodes, high pressure is proven to improve the cathode connectivity and avoid cathode cracking over cycling, which improves the possibility of developing cathodes with high sulfur mass loading. This work provides insights into Li-S pouch cell design (e.g., cathode and separator) and highlights pathways to improve cell capacity and cycling performance with applied and monitored pressure

25 ENERGY STORAGE↗

Long Life Na/NiCl2 Cells

The premature capacity failure of Na/NiCl2 secondary cells due to agglomeration of nickel particles on the surface of the NiCl2 cathode is prevented by addition of a minor amount such as 10 percent by weight of a transition metal such as Co, Fe or Mn to the cathode. The chlorides of the transition metals have lower potentials than nickel chloride and chlorinate during charge. A uniform dispersion of the transition metals in the cathodes prevents agglomeration of nickel, maintains morphology of the electrode, maintains the electrochemical area of the electrode and thus maintains capacity of the electrode. The additives do not effect sintering. The addition of sulfur to the liquid catholyte is expected to further reduce agglomeration of nickel in the cathode.

Bugga, Ratnakumar V.↗

Chapter 6: Abuse Response of Batteries Subjected to Mechanical Impact

Electrochemical and thermal models to simulate nominal performance and abuse response of lithium-ion cells and batteries have been reported widely in the literature. Studies on mechanical failure of cell components and how such events interact with the electrochemical and thermal response are relatively less common. This chapter outlines a framework developed under the Computer Aided Engineering for Batteries program to couple failure modes resulting from external mechanical loading to the onset and propagation of electrochemical and thermal events that follow. Starting with a scalable approach to implement failure criteria based on thermal, mechanical, and electrochemical thresholds, we highlight the practical importance of these models using case studies at the cell and module level. The chapter also highlights a few gaps in our understanding of the comprehensive response of batteries subjected to mechanical crash events, the stochastic nature of some of these failure events, and our approach to build safety maps that help improve robustness of battery design by capturing the sensitivity of some key design parameters to heat generation rates under different mitigation strategies.

abuse simulations↗

Failure Analysis of Nickel-hydrogen Cell Subjected to Simulated Low Earth Orbit Cycling

A nickel-hydrogen cell completed 10,080 simulated low earth orbit charge/discharge cycles at depths-of-discharge ranging from 50 to 80 percent prior to failure. The cell is of the Air Force design, rated at 50 ampere-hours, 8.9 cm (3.5 inches) in diameter. Upon disassembly, the end of the polysulfone core supporting the electrode stack was found to have fractured. This allowed the electrode stack to expand. A massive short was found at the inner diameter of the electrodes centered roughly at plate set 34 to 37 from the positive end of the electrode stack. The damaged area extended through approximately one third of the electrode stack, with the effect becoming progressively less with distance from plate set 34 to 37. Measured thicknesses of the positive plates were significantly greater than the initial specification values. The postulated cause of failure is that positive plate growth caused fracture of the shoulder from the end of the polysulfone core on which the electrodes are mounted. The electrode stack relieved and pressure points were created at the area near the inner diameter of the plates at the tab attachment. A short occurred at a pressure point between opposing plates and propagated to other electrode sets due to thermal and mechanical stresses caused by the short.

Mueller, V. C.↗

Transforming growth factor-beta1 promotes the migration and invasion of sphere-forming stem-like cell subpopulations in esophageal cancer

Esophageal cancer is one of the most lethal solid malignancies. Mounting evidence demonstrates that cancer stem cells (CSCs) are able to cause tumor initiation, metastasis and responsible for chemotherapy and radiotherapy failures. As CSCs are thought to be the main reason of therapeutic failure, these cells must be effectively targeted to elicit long-lasting therapeutic responses. We aimed to enrich and identify the esophageal cancer cell subpopulation with stem-like properties and help to develop new target therapy strategies for CSCs. Here, we found esophageal cancer cells KYSE70 and TE1 could form spheres in ultra low attachment surface culture and be serially passaged. Sphere-forming cells could redifferentiate and acquire morphology comparable to parental cells, when return to adherent culture. The sphere-forming cells possessed the key criteria that define CSCs: persistent self-renewal, overexpression of stemness genes (SOX2, ALDH1A1 and KLF4), reduced expression of differentiation marker CK4, chemoresistance, strong invasion and enhanced tumorigenic potential. SB525334, transforming growth factor-beta 1(TGF-β1) inhibitor, significantly inhibited migration and invasion of sphere-forming stem-like cells and had no effect on sphere-forming ability. In conclusion, esophageal cancer sphere-forming cells from KYSE70 and TE1 cultured in ultra low attachment surface possess cancer stem cell properties, providing a model for CSCs targeted therapy. TGF-β1 promotes the migration and invasion of sphere-forming stem-like cells, which may guide future studies on therapeutic strategies targeting these cells. - Highlights: • Esophageal cancer sphere-forming cells possess cancer stem cell properties. • Sphere-forming cells enhance TGF-β1 pathway activity. • TGF-β 1 inhibitor suppresses the migration and invasion of sphere-forming cells.

60 APPLIED LIFE SCIENCES↗