Search NASA⌕ Search

SEARCH · Search NASA

Results for “charge selectivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Validity of the Aluminum Equivalent Approximation in Space Radiation Shielding

The origin of the aluminum equivalent shield approximation in space radiation analysis can be traced back to its roots in the early years of the NASA space programs (Mercury, Gemini and Apollo) wherein the primary radiobiological concern was the intense sources of ionizing radiation causing short term effects which was thought to jeopardize the safety of the crew and hence the mission. Herein, it is shown that the aluminum equivalent shield approximation, although reasonably well suited for that time period and to the application for which it was developed, is of questionable usefulness to the radiobiological concerns of routine space operations of the 21 st century which will include long stays onboard the International Space Station (ISS) and perhaps the moon. This is especially true for a risk based protection system, as appears imminent for deep space exploration where the long-term effects of Galactic Cosmic Ray (GCR) exposure is of primary concern. The present analysis demonstrates that sufficiently large errors in the interior particle environment of a spacecraft result from the use of the aluminum equivalent approximation, and such approximations should be avoided in future astronaut risk estimates. In this study, the aluminum equivalent approximation is evaluated as a means for estimating the particle environment within a spacecraft structure induced by the GCR radiation field. For comparison, the two extremes of the GCR environment, the 1977 solar minimum and the 2001 solar maximum, are considered. These environments are coupled to the Langley Research Center (LaRC) deterministic ionized particle transport code High charge (Z) and Energy TRaNsport (HZETRN), which propagates the GCR spectra for elements with charges (Z) in the range I <= Z <= 28 (H -- Ni) and secondary neutrons through selected target materials. The coupling of the GCR extremes to HZETRN allows for the examination of the induced environment within the interior' of an idealized spacecraft as approximated by a spherical shell shield, and the effects of the aluminum equivalent approximation for a good polymeric shield material such as genetic polyethylene (PE). The shield thickness is represented by a 25 g/cm spherical shell. Although one could imagine the progression to greater thickness, the current range will be sufficient to evaluate the qualitative usefulness of the aluminum equivalent approximation. Upon establishing the inaccuracies of the aluminum equivalent approximation through numerical simulations of the GCR radiation field attenuation for PE and aluminum equivalent PE spherical shells, we Anther present results for a limited set of commercially available, hydrogen rich, multifunctional polymeric constituents to assess the effect of the aluminum equivalent approximation on their radiation attenuation response as compared to the generic PE.

Badavi, Francis F.↗

Nonmetallic materials contamination studies

In order to impose adequate contamination control requirements in the selection of Wide Field Planetary Camera (WFPC) materials and to develop a data base of potential optical degradation of the WFPC charge-couple device window, the outgassing properties of WFPC materials and the collected volatile condensed material (CVCM) effects on MgF2 transmittance were measured. Changes in the transmittance were monitored in the wavelength region from 115 nm to 300 nm for selected CVCM thicknesses up to 150 nm. The outgassing properties of reemitted CVCM were also studied.

Muscari, J. A.↗

Photoemission Experiments for Charge Characteristics of Individual Dust Grains

Photoemission experiments with UV radiation have been performed to investigate the microphysics and charge characteristics of individual isolated dust grains of various compositions and sizes by using the electrodynamic balance facility at NASA Marshall Space Flight Center. Dust particles of 2-10 gm diameter are levitated in a vacuum chamber at pressures approximately 10(exp-5) torr and exposed to a collimated beam of UV radiation in the 120-200 nm spectral range from a deuterium lamp source with a MgF2 window. A monochromator is used to select the UV wavelength with a spectral resolution of 8 nm. The electrodynamic facility permits measurements of the charge and diameters of particles of known composition, and monitoring of photoemission rates with the incident UV radiation. Experiments have been conducted on test particles of silica and polystyrene to determine the photoelectric yields and surface equilibrium potentials when exposed to UV radiation. A brief description of an experimental procedure for photoemission studies is given and some preliminary laboratory measurements of the photoelectric yields of individual dust particles are presented.

Abbas, M. M.↗

Crystalline Colloidal Arrays in Polymer Matrices

Crystalline Colloidal Arrays (CCA, also known as colloidal crystals), composed of aqueous or nonaqueous dispersions of self-assembled nanosized polymer colloidal spheres, are emerging toward the development of advanced optical devices for technological applications. The spontaneous self assembly of polymer spheres in a dielectric medium results from the electrostatic repulsive interaction between particles of uniform size and charge distribution. In a way similar to atomic crystals that diffract X-rays, CCA dispersions in thin quartz cells selectively and efficiently Bragg diffract the incident visible light. The reason for this diffraction is because the lattice (body or face centered cubic) spacing is on the order of the wavelength of visible light. Unlike the atomic crystals that diffract a fixed wavelength, colloidal crystals in principle, depending on the particle size, particle number and charge density, can diffract W, Vis or IR light. Therefore, the CCA dispersions can be used as laser filters. Besides, the diffraction intensity depends on the refractive index mismatch between polymer spheres and dielectric medium; therefore, it is possible to modulate incident light intensities by manipulating the index of either the spheres or the medium. Our interest in CCA is in the fabrication of all-optical devices such as optical switches, limiters, and spatial light modulators for optical signal processing. The two major requirements from a materials standpoint are the incorporation of suitable nonlinear optical materials (NLO) into polymer spheres which will allow us to alter the refractive index of the spheres by intense laser radiation, and preparation of solid CCA filters which can resist laser damage. The fabrication of solid composite filters not only has the advantage that the films are easier to handle, but also the arrays in solid films are more robust than in liquid media. In this paper, we report the photopolymerization process used to trap CCA in polymer matrices, the factors which affect the optical diffraction qualities of resulting polymer films, and methods to improve the efficiencies of solid optical filters. Before this, we also present the experimental demonstration, of controlling the optical diffraction intensities from aqueous CCA dispersions by varying the temperature, which establishes the feasibility of fabricating all-optical switching devices with nonlinear periodic array structures.

Sunkara, Hari B.↗

Method of forming silicon structures with selectable optical characteristics

Silicon and metal are coevaporated onto a silicon substrate in a molecular beam epitaxy system with a larger than stoichiometric amount of silicon so as to epitaxially grow particles of metal silicide embedded in a matrix of single crystal epitaxially grown silicon. The particles interact with incident photons by resonant optical absorption at the surface plasmon resonance frequency. Controlling the substrate temperature and deposition rate and time allows the aspect ratio of the particles to be tailored to desired wavelength photons and polarizations. The plasmon energy may decay as excited charge carriers or phonons, either of which can be monitored to indicate the amount of incident radiation at the selected frequency and polarization.

Fathauer, Robert W.↗

Frequency analysis of 4- to 6-keV electrons associated with an auroral arc

The high time resolution (HTR) experiment considered consists of four sections, including electrostatic deflection plates, electron multiplier, preamplifier-integrator, and frequency analyzer. Electrons in the energy range from 4 to 6 keV electrons are selected by the deflection system, after which they are detected, multiplied, and passed to the charge sensitive preamplifier. The charge pulses are amplified and integrated, and the resulting voltage pulse series is fed to the frequency analyzer. The experiment is essentially a flux detector, so that estimates of the input flux can be made from the mean value of the output spectrum. The results obtained with the HTR in a rocket flight on March 14, 1974, are discussed. The lack of modulation noticed in the high-frequency range indicates that there is insufficient wave energy available in the vicinity of the rocket to produce a wave-particle interaction which the HTR is able to observe. This finding is consistent with the stabilization of the plasma by the low flux of energetic electrons.

Murphree, J. S.↗

Dialysis system

The improved hemodialysis system utilizes a second polymeric membrane having dialyzate in contact with one surface and a urea decomposition solution in contact with the other surface. The membrane selectively passes urea from the dialyzate into the decomposition solution, while preventing passage of positively charged metal ions from the dialyzate into the solution and ammonium ions from the solution into the dialyzate.

Mueller, W. A.↗

Study of Two Digital Charge-Coupled Devices

Recent report describes reliability study of two charge-coupled-device (CCD) shift registers. Major objective of study was to establish methodology for selecting, testing, screening, derating and applying CCD's. Includes a discussion of CCD structures and operating principles. Characteristics of SCCD and BCCD types are compared.

Wilson, D. D.↗

Time-to-failure analysis for NiCd batteries in a CPS orbit

Cells operating at five degrees Celsius or less, and going to 60 to 65 percent depth of discharge, were studied as to whether they could achieve a useful working life of 7.5 years in a GPS orbit. The characteristics of various orbits were compared and it is noted that the GPS orbit experiences only 220 cycles a year and must be treated as a geosynchronous rather than a low Earth orbit. Cell degradation is considered to be the result of both trickle-charge degradation and degradation due to cycling. Time-to-failure values are presented for selected temperatures and depth of discharges.

Sense, K. A.↗

Surface phenomena in plasma environments

Plasma interactions and their effects on materials depend on a number of factors, including the pre-existing environment, the properties of surface materials and the characteristics of the system. An additional dimension is the question of mission: some payloads may be much more sensitive to plasma interactions than others. As an example, a payload whose objective is to measure the ambient environment will be more sensitive to any effects than will a power system. Material specific effects include charging and its associated effects, which can result in short- and long-term damage. Selection of materials for a particular application requires consideration of all factors and assessment of effects due to all causes. Proper selection and suitability determination requires analysis to identify the actual environment combined with testing under exposure to single and combined environment factors.

Purvis, C. K.↗

Calculations of molecular ionization energies using a self-consistent-charge Hartree-Fock-Slater method

A numerical-variational method for performing self-consistent molecular calculations in the Hartree-Fock-Slater (HFS) model is presented. Molecular wavefunctions are expanded in terms of basis sets constructed from numerical HFS solutions of selected one-center atomlike problems. Binding energies and wavefunctions for the molecules are generated using a discrete variational method for a given molecular potential. In the self-consistent-charge (SCC) approximation to the complete self-consistent-field (SCF) method, results of a Mulliken population analysis of the molecular eigenfunctions are used in each iteration to produce 'atomic' occupation numbers. The simplest SCC potential is then obtained from overlapping spherical atomlike charge distributions. Molecular ionization energies are calculated using the transition-state procedure; results are given for CO, H2O, H2S, AlCl, InCl, and the Ni5O surface complex. Agreement between experimental and theoretical ionization energies for the free-molecule valence levels is generally within 1 eV. The simple SCC procedure gives a reasonably good approximation to the molecular potential, as shown by comparison with experiment, and with complete SCF calculations for CO, H2O, and H2S.

Rosen, A.↗

Photoemission Experiments for Charge Characteristics of Individual Dust Grains

Photoemission experiments with UV radiation have been performed to investigate the microphysics and charge characteristics of individual isolated dust grains of various compositions and sizes by using the electrodynamic balance facility at NASA Marshall Space Flight Center. Dust particles of 1 - 100 micrometer diameter are levitated in a vacuum chamber at pressures approx. 10(exp -5) torr and exposed to a collimated beam of UV radiation in the 120-300 nanometers spectral range from a deuterium lamp source with a MgF2 window. A monochromator is used to select the UV radiation wavelength with a spectral resolution of 8 nanometers. The electrodynamic facility permits measurements of the charge and diameters of particles of known composition, and monitoring of photoemission rates with the incident UV radiation. Experiments have been conducted on Al2O3 and silicate particles, and in particular on JSC-1 Mars regolith simulants, to determine the photoelectron yields and surface equilibrium potentials of dust particles when exposed to UV radiation in the 120-250 micrometers spectral range. A brief discussion of the experimental procedure, the results of photoemission experiments, and comparisons with theoretical models will be presented.

Abbas, M. M.↗

Charge retention test experiences on Hubble Space Telescope nickel-hydrogen battery cells

The Hubble Space Telescope (HST) nickel-hydrogen battery module was designed by Lockheed Missile & Space Co (LMSC) and manufactured by Eagle-Picher Ind. (EPI) for the Marshall Space Flight Center (MSFC) as an Orbital Replacement Unit (ORU) for the nickel-cadmium batteries originally selected for this low earth orbit mission. The design features of the HST nickel hydrogen battery are described and the results of an extended charge retention test are summarized.

Nawrocki, Dave E.↗

Seismic exploration for water on Mars

It is proposed to soft-land three seismometers in the Utopia-Elysium region and three or more radio controlled explosive charges at nearby sites that can be accurately located by an orbiter. Seismic signatures of timed explosions, to be telemetered to the orbiter, will be used to detect present surface layers, including those saturated by volatiles such as water and/or ice. The Viking Landers included seismometers that showed that at present Mars is seismically quiet, and that the mean crustal thickness at the site is about 14 to 18 km. The new seismic landers must be designed to minimize wind vibration noise, and the landing sites selected so that each is well formed on the regolith, not on rock outcrops or in craters. The explosive charges might be mounted on penetrators aimed at nearby smooth areas. They must be equipped with radio emitters for accurate location and radio receivers for timed detonation.

Page, Thornton↗

Single and double charge transfer of He(2+) ions with molecules at near-thermal energies

Rate coefficients were measured for charge-transfer reactions of He(2+) ions with H2, N2, O2, CO, CO2, and H2O. The experiments were carried out using a selected-ion drift-tube mass spectrometer. Total rate coefficients are found to be very large and are generally close to the limiting Langevin capture rate coefficients or the corresponding ADO-model (Su and Bowers, 1973) coefficients. The product-ion spectra indicate that both single and double charge transfer and possibly transfer ionization occur in these reactions.

Tosh, R. E.↗

IMP 6, 7 and 8 observations of the composition and time variations of low energy cosmic rays

The charge composition and time variations of quiet-time cosmic rays in the energy range 10 to 25 MeV/nucleon were studied to determine the source of the enhancement of quiet-time intensities of low energy nitrogen and oxygen nuclei observed by Pioneer 10. Time variations were established from data from IMPs 6, 7, and 8; the charge composition was obtained by summing data from IMP 7 and IMP 8. The neon to carbon ratio present in solar rays is too low to explain an observed enhancement of neon. Helium and oxygen have the same percentage modulation for a range of x5 in intensity. This can be explained within the framework of the field-force approximation and the selection mechanism based on the first ionization potential proposed by Fisk et al. (1974) if both oxygen and helium are singly charged.

Von Rosenvinge, T. T.↗

Detection of nighttime atmospheric scattering of lunar UV radiances by the Nimbus 4 BUV instrument

Morphological studies of nighttime dark current data from the Nimbus 4 backscattered UV experiment indicate enhancements during the period of a full moon. The nature and magnitude of these lunar UV radiance enhancements are determined, and their potential use as a measure of nighttime ozone is considered. The data were grouped into five-day study intervals centered about each full moon sequence, and about each corresponding new moon interval. The analysis was performed in a magnetic frame of reference (McIlwain, 1961) in order to evaluate magnetospheric perturbation effects and to minimize the effects of charged energetic particle contamination or precipitation. All isolated elements showing spurious or abnormal enhancements were removed selectively (about 3%) to further screen the data. Results demonstrate the presence and uniqueness of a lunar signal, induced by atmospherically backscattered UV radiation. This signal was not sufficiently strong, however, to accurately map global nighttime ozone on the Nimbus 4 instrument.

Stassinopoulos, E. G.↗