Search NASA⌕ Search

SEARCH · Search NASA

Results for “charged particle scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Parameterization of electron attachment rate constants for impurities in LArTPC detectors

The ability of free electrons to drift long distances at high velocities in pure liquid argon under an applied electric field has been exploited for the past forty years to implement detectors with increasingly larger volumes for high energy physics research. The attachment of free electrons to impurities in the LAr is an important limit on the free instrumented volume of these extremely large detectors, and impurity concentrations as small as 100 ppt can reduce their resolution and efficiency. In this paper, we summarize the electron attachment rate constants as a function of the applied electric field, for common impurities in LArTPCs, obtained from data in the literature. Here, we further provide analytical functions to parameterize the data, which are useful to compare with new measurements, to model and analyze the performance of existing detectors, and to predict the performance of new detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

The Majorana Demonstrator readout electronics system

The M AJORANA D EMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76 Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the M AJORANA D EMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Testing, Operation, and Analysis of a Photosensitive LArTPC

LArTPCs detect charge and light from particle interactions to study neutrinos indirectly. TinyTPC, a compact LArTPC with a pixelated readout system (LArPix), aims to improve energy measurements for low-energy events by enhancing ionization charge collection. It will explore the effects of photosensitive dopants and xenon in liquid argon. Isobutylene, with ionization energy near argon's scintillation energy, efficiently converts scintillation light into a detectable ionization signal.

McCright, Hannah↗

A review of NEST models for liquid xenon and an exhaustive comparison with other approaches

This paper discusses the microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event searches for new physics, and describes experimental observables useful for understanding detector performance. The scintillation and ionization yield distributions for signal and background are presented using the Noble Element Simulation Technique (NEST), a toolkit based on experimental data and simple empirical formulas, which mimic previous microphysics modeling but are guided by data. The NEST models for light and charge production as a function of the particle type, energy, and electric field are reviewed, along with models for energy resolution and final pulse areas. NEST is compared with other models or sets of models and validated against real data, with several specific examples drawn from XENON, ZEPLIN, LUX, LZ, PandaX, and table-top experiments used for calibrations.

WIMPs↗

Detection of the isotopes of heavy cosmic ray nuclei

A counter telescope designed to detect and resolve the isotopic composition of cosmic ray nuclei heavier than neon is being prepared. The telescope consists of a rather conventional charge measuring array using two scintillator elements and two solid Cerenkov radiators of differing refractive index. The mass measurement is obtained by combining the velocity information from one or both of the Cerenkov radiators operating near their threshold with residual range measured in a block of nuclear emulsion. Path length corrections and particle location in the emulsions is provided by a spark chamber fired in coincidence with potentially suitable particles. The telescope has a geometry factor of 530 sq cm sr roughly. It should be able to resolve the isotopes of iron over the energy range of 300 to 720 Mev/n and those of neon over 300 to 400 MeV/n. The expected response and characteristics of the telescope are described in detail and the sensitivity to rare isotopes discussed.

Gilman, C. M.↗

High sensitivity high resolution double scatter 1-30 MeV gamma ray telescope

The design and performance of the double-scatter 1-30-MeV gamma-ray telescope developed at the University of California for balloon-borne observations are reported and illustrated with drawings, diagrams, and graphs. The telescope comprises an upper array of 16 6.03 x 6.03 x 100-cm plastic scintillator bars viewed by photomultiplier tubes (PMTs) at both ends, a lower array (at 100-cm distance) of 16 4.83 x 4.83 x 100-cm NaI(Tl) bars viewed at both ends by PMTs, and four 122 x 122 x 0.64-cm plastic sheets viewed by four PMTs each as charged-particle anticoincidence shielding. The operating principle of the telescope, the tests conducted on the NaI(Tl) bars, the on-board data-processing electronics, and the overall performance are characterized. Performance parameters include area 1 sq m, field of view pi sr, 4-sigma sensitivity above 1 MeV 0.00004 gamma/sq cm sec over 25 h, angular resolution about 3.5 deg FWHM, and energy resolution 10 percent at 1 MeV and 6 percent at 6 MeV.

Zych, A. D.↗

Advanced Electronics for the SONTRAC Neutron Spectrometer

Solar neutrons are the tell-tale of highly energetic processes (e.g. solar flares) at the Sun in which particle acceleration is taking place over a broad range in energy. Unlike charged radiation, neutrons escape unscathed from the ambient magnetic fields, providing a view of particle acceleration unhindered by the effects of transport. High-energy neutrons are challenging to measure with the traditional double scatter technique based on time-of-flight (ToF). This technique is limited by the finite flight path and active scintillator sizes required by small satellite platforms. The new SOlar Neutron TRACking (SONTRAC) concept, based on scintillating-fiber bundles, will provide high resolution imaging of fast neutrons at energies where the bulk of solar and magnetospheric neutrons resides. Recent development of the new SONTRAC instrument concept's advanced electronics and processing algorithms are presented.

SiPM readout↗

Relative Fluxes of Primary Particles in B-C-N-O Group from the ATIC Experiment (Science Flight)

The ATIC balloon-born experiment measures the energy spectra of elements from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is comprised of a fully active bismuth germinate calorimeter, a carbon target with embedded scintillator hodoscopes, and a silicon matrix that is used as a main charge detector. The silicon matrix produces good charge resolution for the protons and helium but only a partial resolution for heavier nuclei. In the present paper a charge resolution of ATIC device was improved and backgrounds were reduced in the region from Be to Si by means of the upper layer of the scintillator hodoscope that was used as charge detector together with silicon matrix. Relative fluxes of nuclei B, C, N, O in the energy region from about 20 GeV/nucleon to 200 GeV/nucleon that were obtained from new high-resolution and high-quality charge spectra of nuclei are presented.

Panov, A. D.↗

From Detector Layout to Signal Analysis: Geometry Optimization and Neutron-Gamma Tagging in Plastic Scintillator Detectors

Neutrinos are elementary particles with many properties still unknown. Their masses so far have only upper and lower limits. Still, due to neutrino oscillations, it is clear that they are not massless, as stated by the Standard Model of Elementary Particles. Neutrinos are also present in the Universe in vast amounts, but they rarely interact with the surrounding matter. Their abundance makes them very interesting for many theories beyond the Standard Model, e.g., dark matter searches and CP symmetry violation in the leptonic sector, which could be (partially) responsible for the observed matter-antimatter asymmetry in today's Universe.\\ The Deep Underground Neutrino Experiment (DUNE) is a next-generation accelerator-based neutrino oscillation experiment that will study neutrinos with unprecedented precision and may answer many open questions. DUNE uses a powerful neutrino beam from Fermilab. It consists of a Near Detector (ND) complex to measure neutrinos before oscillat ion, and a Far Detector (FD) complex $1300\ \mathrm{km}$ away to measure them after oscillation. As part of the ND complex, measurements are also possible with different angles to the neutrino beam. This enables excellent control of systematic uncertainties of e.g., neutrino cross section measurements.\\ One detector in the near detector complex is The Muon Spectrometer (TMS), an extension of a Liquid Argon (LAr) detector that measures the charge and momentum of muons produced in neutrino interactions within the LAr. The design of this detector, which consists of alternating layers of steel and plastic scintillator bars, must be optimized for the expected muon energies.\\ In this thesis, a study of the optimal module orientation plan is presented, which is necessary for the physics performance of the near detector complex and, by extension, DUNE. As part of this study, the event reconstruction was also developed and improved. Simulated muons are then reconstructed, and the performan ce of different module orientation plans is tested.\\ As a second part, a study of neutron and gamma tagging using a Pulse Shape Discriminating (PSD) plastic scintillator is presented. The properties of this material allow particle differentiation based on the temporal distribution of emitted light. A novel approach to using the individual light signals was successfully tested using data from a small, local test setup.

Nehm, Asa [Mainz U.]↗

Magnetic mass spectrometer search at 2750 m. for hypothetical massive particles

A search was conducted for hypothetical singly charged massive particles which might be produced in collisions of very highly energetic cosmic ray particles with nuclei in the upper atmosphere. If such particles have sufficiently long lifetime and small cross section for interaction, they could survive to mountain altitude. A cosmic ray spectrometer consisting of superconducting magnet, wire spark chambers and time-of-flight scintillation counters was used to search for these particles at mountain altitude (2750 m). For any choice of hypothetical mass in the 5 to 10 GeV/c-squared range the upper limit to the vertical intensity of the particle was observed to be less than or roughly equal to 10 to the -6th/sq. cm/s/(GeV/c).

Barber, H. B.↗

Analysis of SOFCAL calibration data

Ionization calorimeters determine the total energy of a particle by absorbing, within the mass of the calorimeter, the entire energy of the particle or a significant (and determinable) fraction of it. The JACEE group has used passive ionization calorimetery, which employs photographic emulsions as the detector medium, to measure the charge composition and energy spectrum of cosmic rays up to, and exceeding, 10(exp 14)eV. The SOFIC approach depends similarly on the use of three-dimensional nuclear-electromagnetic shower theory to relate the ionization deposits obtained during a shower to the energy of the particle causing the shower. Bundles of thousands of scintillating optical fibers are read out using image-intensified CCD's. Such an event may be triggered by a fast shower detector placed under the instrument or if only heavy particles are of interest, from a fast primary Cerention detector placed above the calorimeter. In the first study, fast Hammatsu photomultiplier tubes were purchased and tested for possible application for a triggering purpose. In the second study, some refinements have been made to the theoretical treatment of hadronic interactions in the central collision region. These will be helpful in improving the simulations necessary for observations of high energy cosmic ray nuclei with a SOFIC.

Gregory, John C.↗

Proposal for a dedicated search for millicharged and fractionally charged particles at LANL

In this paper, we propose an experiment, LANSCE-mQ, aiming to detect fractionally charged and millicharged particles (mCPs) using an 800 MeV proton beam fixed target at the Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory. This search can shed new light on numerous fundamental questions, including charge quantization, the predictions of string theories and grand unification theories, the gauge symmetry of the Standard Model, dark sector models, and the tests of cosmic reheating. We propose to install two-layer scintillation detectors made of plastic (such as EJ-200) or CeBr 3 to search for mCPs. Dedicated geant4 detector simulations and in situ measurements have been conducted to obtain a preliminary determination of the background rate. The dominant backgrounds are beam-induced neutrons and coincident dark current signals from the photomultiplier tubes, while beam-induced high-energy photons ( γ ’s) and cosmic muons are subdominant. We determined that LANSCE-mQ, the dedicated mCP experiment, has the leading mCP sensitivity for mass between ∼ 1 and 300 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a novel, windowless, amorphous selenium based photodetector for use in liquid noble detectors

Detection of the vacuum ultraviolet (VUV) scintillation light produced by liquid noble elements is a central challenge in order to fully exploit the available timing, topological, and calorimetric information in detectors leveraging these media. Here in this paper, we characterize a novel, windowless amorphous selenium based photodetector with direct sensitivity to VUV light. We present here the manufacturing and experimental setup used to operate this detector at low transport electric fields (2.7–5.2 V/μm) and across a wide range of temperatures (77 K–290 K). This work shows that the first proof-of-principle windowless amorphous selenium device is robust under cryogenic conditions, responsive to VUV light at cryogenic temperatures, and preserves argon purity. These findings motivate a continued exploration of amorphous selenium devices for simultaneous detection of scintillation light and ionization charge in noble element detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monopole search below the Parker limit with the MACRO detector at Gran Sasso

The MACRO detector approved for the Gran Sasso Underground Laboratory in Italy will be the first capable of performing a definitive search for super-massive grand unified theory (GUT) monopoles at a level significantly below the Parker flux limit of 10 to the minus 15th power square centimeters Sr(-1) 5(-1). GUT monopoles will move at very low velocities (V approx. 0.001 c) relative to the Earth and a multifaceted detection technique is required to assume their unambiguous identification. Calculations of scintillator response to slow monopoles and measurements of scintillation efficiency for low energy protons have shown that bare monopoles and electrically charged monopoles moving at velocities as low as 5 x .0001 c will produce detectable scintillation signals. The time-of-flight between two thick (25 cm) liquid scintillation layers separated by 4.3m will be used in conjunction with waveform digitization of signals of extended duration in each thick scintillator to provide a redundant signature for slow penetrating particles. Limited streamer tubes filled with He and n-pentane will detect bare monopoles with velocities as low as 1 x 0.0001 c by exploiting monopole induced level mixing and the Penning effect.

Tarle, G.↗

Validation of the imaging neutral particle analyzer in nearly MHD quiescent plasmas using injected beam ions on DIII-D

The imaging neutral particle analyzer (INPA) is a scintillator-based diagnostic that provides energy and radially resolved measurements of confined fast ions. To verify operation, understanding, and modeling of the diagnostic performance, distributions of deuterium beam ions in low density, nearly MHD-quiescent plasmas are measured on the DIII-D tokamak using the INPA. Here, the distribution is altered by changing the pitch-angle scattering rate with electron cyclotron heating (ECH). Experimental images are mostly reproduced with simulation of core fast ions charge exchanging with injected beam and edge cold neutrals in classical cases. Image comparisons between the experiment and simulation show agreement with less than 25% discrepancies near the beam injection energy of 50 keV. Other strong passive signals, observed in a localized region on the image, are suggested to come from charge exchange between cold neutrals and fast ions around the plasma boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The GRAD high-altitude balloon flight over Antarctica

The Gamma Ray Advanced Detector (GRAD) consists of a n-type germanium detector inside an active bismuth-germanate Compton and charged particle shield with additional active plastic shielding across the aperture. It will be flown on a high-altitude balloon at 36 km altitude at a latitude of 78 deg S over Antarctica for observations of gamma radiation emitted by the radioactive decay of Co-56 in the supernova SN1987A, for assessment of the performance of bismuth-germanate scintillation material in the radiation environment of near space, for gathering information on the gamma-ray background over Antarctica, and for testing fault-tolerant software.

Eichhorn, G.↗

Determination of boron and lithium by recording the products from (n, alpha) reactions

Irradiation with thermal neutrons in the VVR-S reactor provides a nondestructive method for determining the presence of boron and lithium in solids. The charged particles produced in the reactions Li-6(n,alpha)H-3 and B-10(n,alpha)Li-7 were detected using CsI single crystal. For alpha-particle spectrometry in the boron determination, an ionization chamber (W and Sn electrodes, 99% Ar + 1% H2) was developed allowing both absolute and relative measurements. In determining boron in lithium-containing samples, both scintillation and ionization chambers are used. In determining lithium in minerals, the error was 1.5%, and the sensitivity 0.00005 wt.%. In the determination of boron in SiC with a concentration of boron approximately (3 plus or minus 2) the error given by the alpha-range uncertainty was 15%.

Lobanov, Y. M.↗