Search NASA⌕ Search

SEARCH · Search NASA

Results for “chemical detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Chapter 13: Time-of-Flight Secondary-Ion Mass Spectrometry and Atom Probe Tomography

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) and atom probe tomography (APT) have many similarities. Both detect the chemical makeup of a solid material at ppm or better sensitivity, while retaining the spatial location information from the signal. Both use a similar principle to measure a signal associated with a given charged secondary ion—the flight time it takes a secondary ion to reach the detector after it is generated. Both are destructive techniques—albeit destructive of very small volumes—because the signal measured is generated by the removal of material from the sample itself. Importantly, both techniques require ultra-high vacuum (UHV) to ensure that the secondary ions, once generated, can reach the detector without collision with other atoms in the gas phase. In the case of TOF-SIMS, the samples can vary from several mm to several inches in size, whereas for APT, the samples are cones several hundred microns in size that are prepared in a special manner (covered in detail later in the chapter). We will discuss the basic fundamentals of each technique and cover several examples of the technique applied to photovoltaic materials, which should give a good idea of the types of information one can gain from TOF-SIMS and APT and how they are complementary as they both operate at different length scales: at the hundreds of microns to hundreds of nanometer scale for TOF-SIMS and at the nanometer to a few angstroms scale for APT.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Evidence of Dirac Quantum Spin Liquid in YbZn 2⁢ GaO 5

The emergence of a quantum spin liquid (QSL), a state of matter that can result when electron spins are highly correlated but do not become ordered, has been the subject of a considerable body of research in condensed matter physics [1,2]. Spin liquid states have been proposed as hosts for high-temperature superconductivity [3] and can host topological properties with potential applications in quantum information science [4]. The excitations of most quantum spin liquids are not conventional spin waves but rather quasiparticles known as spinons, whose existence is well established experimentally only in one-dimensional systems; the unambiguous experimental realization of QSL behavior in higher dimensions remains challenging. Here, in this work, we investigate the novel compound $YbZn_{2}GaO_{5}$, which hosts an ideal triangular lattice of effective spin-1/2 moments with no detectable inherent chemical disorder. Thermodynamic and inelastic neutron scattering measurements performed on high-quality single crystal samples of $YbZn_{2}GaO_{5}$ exclude the possibility of long-range magnetic ordering down to 0.06 K, demonstrate a quadratic power law for the specific heat and reveal a continuum of magnetic excitations in parts of the Brillouin zone. Both low-temperature thermodynamics and inelastic neutron scattering spectra suggest that $YbZn_{2}GaO_{5}$ is a U(1) Dirac QSL with spinon excitations concentrated at certain points in the Brillouin zone. We advanced these results by performing additional specific heat measurements under finite fields, further confirming the theoretical expectations for a Dirac QSL on the triangular lattice of $YbZn_{2}GaO_{5}$.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal spectral resolution for solids and liquids using FT and other infrared spectrometers: How much resolution do you really need?

In this study we investigate the possibility of using spectral resolutions for infrared measurements of solids and liquids that are not powers of two, e.g. are not at 1, 2, 4, 8, or 16 cm-1 resolution. In almost all reported literature of the last fifty years the resolution used to record for a Fourier transform infrared spectrum has been a power of two. This stems from the fact that 1) the Cooley-Tukey algorithm used to compute such a transform was constructed to use only powers of two and was also driven by 2) the fact that the computing horsepower required to compute the Fourier transform increases as N?log?_2 (N), where N is the number of points in the interferogram (spectrum). For typical spectra, however, the CPU time is no longer a consideration. Our study is based on both liquid and solid spectra, all of which were recorded at 2 cm-1 resolution. There were at total of 70 solids spectra representing 2,472 spectral peaks and 61 liquids spectra (1,765 spectral peaks), each peak being inspected for being singlet / multiplet in nature. Of the 1,765 liquid bands examined, only 27 had widths less than 5 cm-1. Of the 2,472 solid bands examined, only 39 peaks have widths less than 5 cm-1. For liquids, the mean peak width is 24.7 cm-1 but the median peak width is 13.7 cm-1, and, similarly, for solids, the mean peak width is 22.2 cm-1 but the median peak width is 11.2 cm-1. In both cases, solids and liquids, a skewed peak widths distribution was observed, the peak of the distribution representing narrower bands in the 7 to 9 cm-1 FWHM range but displaying a long tail to the very broad bands, with some displaying spectral widths of 100 cm-1 or more. Because one of the most important criteria for successful instrumental design in IR spectroscopy is the spectral resolution, the data were further analyzed showing that a value to resolve 95% of all bands is 5.7 cm-1 for liquids and 5.3 cm-1 for solids; such a resolution would capture the native linewidth (no instrumental broadening) of 95% of all the solids and liquid bands, respectively. Based on the present results we suggest that, when accounting only for intrinsic linewidths an optimized resolution of 6.0 cm-1 will capture 91% of all condensed-phase bands for IR detection of chemical, mineral, and biological materials.

Forland, Brenda M.↗

Deriving the Infrared Complex Refractive Indices of Organic Powders for Optical Modeling: Comparison of Methods

Identification of solids via infrared reflection spectroscopy requires a spectral library of all solids likely to be encountered. A confounding factor in populating such a spectral library is that the reflectance spectra of solids vary with their form, including particle size, film thickness, and substrate. To reduce the efforts of experimentally constructing such a library, an alternate strategy is to use the wavelength-dependent optical constants, n and k, of a solid to calculate a series of reflectance spectra corresponding to each scenario or morphology. Because most n/k measurements are best performed on mm-sized crystals, however, the challenge of determining the optical constants increases when a solid is only readily available as a powder, as is often the case. Some organic solids, such as caffeine, are both unavailable in large crystals and difficult to press into pellets. In this study, the infrared optical constants, or complex refractive indices, of caffeine were determined using three different methods: single-angle reflectance, infrared spectroscopic ellipsometry, and quantitative absorbance measurements of KBr pellets. The n and k values derived through each method were used to model the hyperspectral imaging reflectance spectrum of a caffeine film on a steel planchet. Over 1,110 – 870 cm-1, the single-angle reflectance-derived n and k had the best correlation with the experimental spectrum. These results suggest different organic solids may require different methods to determine the most accurate infrared complex refractive indices for synthetic spectral libraries.

FTIR, hyperspectral imaging, infrared, infrared (I↗

Method to derive the infrared complex refractive indices n(λ) and k(λ) for organic solids from KBr pellet absorption measurements

Obtaining the complex refractive index vectors $n($$\tilde{v})$ and $k($$\tilde{v})$ allows calculation of the (infrared) reflectance spectrum that is obtained from a solid in any of its many morphological forms. Here, we report an adaptation to the KBr pellet technique using two gravimetric dilutions to derive quantitative $n($$\tilde{v})$/$k($$\tilde{v})$ for dozens of powders with greater repeatability. The optical constants of bisphenol A and sucrose are compared to those derived by other methods, particularly for powdered materials. The variability of the $k$ values for bisphenol A was examined by 10 individual measurements, showing an average coefficient of variation for $k$ peak heights of 5.6%. Though no established standards exist, the pellet-derived $k$ peak values of bisphenol A differ by 11% and 31% from their single-angle- and ellipsometry-derived values, respectively. These values provide an initial estimate of the precision and accuracy of complex refractive indices that can be derived using this method. Limitations and advantages of the method are discussed, the salient advantage being a more rapid method to derive $n$/$k$ for those species that do not readily form crystals or specular pellets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Canary

CANARY is a wearable environmental sampling device that is small, lightweight, and low-power. CANARY integrates a novel mechanism that uses magnets rather than powered pumps to mimic human breathing. In its current form, CANARY breathes, but sensor integration can easily turn this into a standalone device for use in airborne detection of chemicals, biologicals, viruses, etc. CANARY has a small footprint and requires little power to operate enabling it to be used in various environments. Los Alamos researcher have developed a working prototype of the air intake system and are seeking licensees for the current air intake, validation outside the lab, or further development to integrate biosensors as desired.

47 OTHER INSTRUMENTATION↗

Chemical Imaging for In Situ Detection and Discrimination of Aquatic Toxins Targeting Voltage Gated Sodium Channels

Biologically derived neurotoxins from cyanobacteria and algae impact environmental resources in addition to being considered a potential biological threat to human and animal health. Activity based assays are essential to detecting and responding to toxic neurotoxin events either naturally occurring or deliberate. Two toxins of interest include saxitoxin and brevetoxin. These toxins bind to and alter the function of voltage-gated sodium channels (NaV channels) which are essential for generating cell membrane action potential. We report the development and refinement of a System for Analysis at Liquid Vacuum Interface (SALVI) to assess the functional activity of saxitoxin and brevetoxin. This approach utilizes a vacuum-compatible microfluidic reactor that permits analysis at the liquid vacuum interface of human derived cells with a neurotoxin of interest in a biologically relevant environment.

54 ENVIRONMENTAL SCIENCES↗

Research in the use of electrets in measuring effluents from rocket exhaust of the space shuttle (6.4 percent scaled model) and Viking 1 launch

Electrets used to detect the chemical composition of rocket exhaust effluents were investigated. The effectiveness of electrets was assessed while comparisons were made with hydrogen chloride measuring devices from chamber and field tests, and computed results from a multilayer diffusion model. The experimental data used were obtained from 18 static test firings, chamber tests, and the Viking 1 launch to Mars. Results show that electrets have multipollutant measuring capabilities, simplicity of deployment, and speed of assessment. The electrets compared favorably with other hydrogen chloride measuring devices. The summary of the measured data from the electrets and the hydrogen chloride detectors was within the upper and lower bounds of the computed hydrogen chloride concentrations from the multilayer diffusion model.

Susko, M.↗

Measurement of low energy cosmic rays aboard Spacelab-1

In December 1983 the first Spacelab mission was launched for a duration of 10 days. Aboard was the Kiel experiment Isotopic Stack designed for measurement of heavy cosmic ray nuclei with nuclear charge equal to or greater than 3 and energies up to some 100MeV/nuc. One part of the stack was rotated in well defined steps registered by an angle encoder to receive information on impact times of the nuclei. Using this time resolving system geomagnetically forbidden particles can be detected. The chemical composition and energy spectra of mainly CNO particles are examined using a rotated 300 microns m thick CR-39 foil beneath a fixed 100 microns m thick Kodak-Cellulose Nitrate foil. About 600 sq cm have been scanned yielding nearly 100 nuclear tracks within an energy range of approximately 8 to 30 MeV/nuc. The calibration is done by means of a postflight irradiation with 410 MeV/nuc Fe-56 at Berkeley Laboratory, California, USA. Relative abundances and energy spectra are presented.

Beaujean, R.↗

Measurements of HO2 chemical kinetics with a new detection method

In this research program, HO2 was detected by the OH(A-X) photofragment from dissociative excitation of HO2 at 147 nm. This detection method was applied to measure the reaction rate constant of HO2 + O3. This reaction rate constant is needed for the understanding of stratospheric chemistry. Since C12 was used in the flow system, photoexcitation of C12 may produce fluorescence to interfere with the measurements. Thus, the photoexcitation process of C12 in the vacuum ultraviolet region was also examined in this research period using synchrotron radiation as a light source. The research results are summarized.

Lee, L. C.↗

Airborne trace contaminants of possible interest in CELSS

One design goal of Closed Ecological Life Support Systems (CELSS) for long duration space missions is to maintain an atmosphere which is healthy for all the desirable biological species and not deleterious to any of the mechanical components in that atmosphere. CELESS design must take into account the interactions of at least six major components; (1) humans and animals, (2) higher plants, (3) microalgae, (4) bacteria and fungi, (5) the waste processing system, and (6) other mechanical systems. Each of these major components can be both a source and a target of airborne trace contaminants in a CELSS. A range of possible airborne trace contaminants is discussed within a chemical classification scheme. These contaminants are analyzed with respect to their probable sources among the six major components and their potential effects on those components. Data on airborne chemical contaminants detected in shuttle missions is presented along with this analysis. The observed concentrations of several classes of compounds, including hydrocarbons, halocarbons, halosilanes, amines and nitrogen oxides, are considered with respect to the problems which they present to CELSS.

Garavelli, J. S.↗

Field-Domain Ion Spectrometry

Field-domain ion spectrometry (FDIS) is variant of established technique known as ion-mobility spectrometry. Operates at atmospheric pressure and only requires small pump to draw air sample into instrument. Strength of retarding electric field varied to distinguish among ions of different mobilities. New concept offers potential for development of small, (hand-held), low-power, portable devices detecting airborne chemical substances in real-time at concentrations at parts-per-billion level.

Bowers, W. D.↗

Hydrazine monitoring in spacecraft

Hydrazine (HZ) and monomethyl hydrazine (MMH) are highly toxic compounds used as fuels in the Space Shuttle Orbiter Main Engines and in its maneuvering and reaction control system. Satellite refueling during a mission may also result in release of hydrazines. During extravehicular activities, the potential exists for hydrazines to contaminate the suit and to be brought into the internal atmosphere inadvertantly. Because of the high toxicity of hydrazines, a very sensitive, reliable, interference-free, and real-time method of measurement is required. A portable ion mobility spectrometer (IMS) has exhibited a low ppb detection limit for hydrazines suggesting a promising technology for the detection of hydrazines in spacecraft air. The Hydrazine Monitor is a modified airborne vapor monitor (AVM) with a custom-built datalogger. This off-the-shelf IMS was developed for the detection of chemical warfare agents on the battlefield. After early evaluations of the AVM for hydrazine measurements showed a serious interference from ammonia, the AVM was modified to measure HZ and MMH in the ppb concentration range without interference from ammonia in the low ppm range. A description of the Hydrazine Monitor and how it functions is presented.

Cross, J. H.↗

Detection of tropospheric OH and HO2 by laser-induced fluorescence at low pressure using the 308nm excitation of OH

Laser-induced fluorescence (LIF) spectroscopy is a highly sensitive method for the direct in situ measurement of hydroxyl concentrations in the atmosphere. Its sensitivity and selectivity relies on the intense discrete UV-absorption lines of OH which are strongest around 282nm and 308nm. We have developed a LIF-instrument based on the low-pressure experiment (FAGE). However, we use 308nm instead of 282nm as excitation wavelength for OH, a concept that is also pursued by other groups. One advantage of the longer excitation wavelength is the higher detection sensitivity due to the about 6 times larger effective OH-fluorescence cross-section. Moreover, the O3/H2O-interference (OH self-generation by the laser) is about a factor of 200 smaller at 308nm than at 282nm. This keeps the interference level well below the projected detection limit of 10(exp 5) OH/cm(exp 3). Atmospheric HO2-radicals are detected by chemical conversion of HO2 into OH with NO.

Hofzumahaus, Andreas↗

Replicator for characterization of cirrus and polar stratospheric cloud particles

A formvar replicator for installation in an aircraft pod has been designed, built, and flight tested on the NASA DC-8. The system incorporates a deicing capability (which can be pressure activated) to enable climb out through icing situations prior to deployment. The system can be operated at preselected speeds such that data can be recorded over a period of one to ten hours on 200 ft of 16mm film. A x2 speed control can be used during flight. Capability exists for detection of chemical constituents by appropriate doping of the formvar solution. An article entitled 'Measurements of ice particles in tropical cirrus anvils: importance in radiation balance' is attached as appendix A.

Hallett, John↗