Search NASA⌕ Search

SEARCH · Search NASA

Results for “chlorine activation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Neighboring Pd single atoms surpass isolated single atoms for selective hydrodehalogenation catalysis

Single atom catalysts have been found to exhibit superior selectivity over nanoparticulate catalysts for catalytic reactions such as hydrogenation due to their single-site nature. However, improved selectively is often accompanied by loss of activity and slow kinetics. Here we demonstrate that neighboring Pd single atom catalysts retain the high selectivity merit of sparsely isolated single atom catalysts, while the cooperative interactions between neighboring atoms greatly enhance the activity for hydrogenation of carbon-halogen bonds. Experimental results and computational calculations suggest that neighboring Pd atoms work in synergy to lower the energy of key meta-stable reactions steps, i.e., initial water desorption and final hydrogenated product desorption. The placement of neighboring Pd atoms also contribute to nearly exclusive hydrogenation of carbon-chlorine bond without altering any other bonds in organohalogens. The promising hydrogenation performance achieved by neighboring single atoms sheds light on a new approach for manipulating the activity and selectivity of single atom catalysts that are increasingly studied in multiple applications.

36 MATERIALS SCIENCE↗

A novel protocol to recycle zirconium from zirconium alloy cladding from used nuclear fuel rods

A potential new zirconium recycling protocol has been demonstrated using unirradiated Zircaloy-based claddings and depleted uranium oxide for the chemical removal of zirconium alloy cladding in used nuclear fuel (UNF) rods from light water reactors. This protocol is based on the application of three new scientific findings. First, a new lower temperature chlorination reaction of zirconium with sulfur monochloride is described. Second, the high solubility of zirconium chloride in thionyl chloride is used to separate it from uranium oxide fuel and fission and activation contaminants. Finally, in the third step, the zirconium chloride is purified by simple recrystallization from thionyl chloride. Utilizing sulfur chloride solvents for a lower temperature liquid-based chemical digestion and purification of zirconium alloy claddings reduces technical complications experienced by current high temperature gas phase chlorination strategies, such as contamination of product streams. This novel protocol has been demonstrated on a 3–50 g scale of unirradiated zirconium alloy, with no significant change in the time required for complete chlorination (3–4 h). This zirconium chlorination protocol has also been performed in the presence of depleted uranium oxide pellets. The depleted fuel pellets do not affect zirconium chlorination, and the chlorination protocol does not chemically or physically alter the fuel pellets. Finally, a preliminary description of an industrial protocol to recycle nuclear grade zirconium from UNF rods is presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Metabolome patterns identify active dechlorination in bioaugmentation consortium SDC-9™

Ultra-high performance liquid chromatography–high-resolution mass spectrometry (UPHLC–HRMS) is used to discover and monitor single or sets of biomarkers informing about metabolic processes of interest. The technique can detect 1000’s of molecules (i.e., metabolites) in a single instrument run and provide a measurement of the global metabolome, which could be a fingerprint of activity. Despite the power of this approach, technical challenges have hindered the effective use of metabolomics to interrogate microbial communities implicated in the removal of priority contaminants. Herein, our efforts to circumvent these challenges and apply this emerging systems biology technique to microbiomes relevant for contaminant biodegradation will be discussed. Chlorinated ethenes impact many contaminated sites, and detoxification can be achieved by organohalide-respiring bacteria, a process currently assessed by quantitative gene-centric tools (e.g., quantitative PCR). This laboratory study monitored the metabolome of the SDC-9™ bioaugmentation consortium during cis-1,2-dichloroethene (cDCE) conversion to vinyl chloride (VC) and nontoxic ethene. Untargeted metabolomics using an UHPLC-Orbitrap mass spectrometer and performed on SDC-9™ cultures at different stages of the reductive dechlorination process detected ~10,000 spectral features per sample arising from water-soluble molecules with both known and unknown structures. Multivariate statistical techniques including partial least squares-discriminate analysis (PLSDA) identified patterns of measurable spectral features (peak patterns) that correlated with dechlorination (in)activity, and ANOVA analyses identified 18 potential biomarkers for this process. Statistical clustering of samples with these 18 features identified dechlorination activity more reliably than clustering of samples based only on chlorinated ethene concentration and Dhc 16S rRNA gene abundance data, highlighting the potential value of metabolomic workflows as an innovative site assessment and bioremediation monitoring tool.

environmental monitoring↗

Direct propylene epoxidation via water activation over Pd-Pt electrocatalysts

Direct electrochemical propylene epoxidation by means of water-oxidation intermediates presents a sustainable alternative to existing routes that involve hazardous chlorine or peroxide reagents. Here, we report an oxidized palladium-platinum alloy catalyst (PdPtO x /C), which reaches a Faradaic efficiency of 66 ± 5% toward propylene epoxidation at 50 milliamperes per square centimeter at ambient temperature and pressure. Embedding platinum into the palladium oxide crystal structure stabilized oxidized platinum species, resulting in improved catalyst performance. The reaction kinetics suggest that epoxidation on PdPtO x /C proceeds through electrophilic attack by metal-bound peroxo intermediates. This work demonstrates an effective strategy for selective electrochemical oxygen-atom transfer from water, without mediators, for diverse oxygenation reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scientific assessment of stratospheric ozone: 1989, volume 1

A scientific review is presented of the current understanding of stratospheric ozone. There have been highly significant advances in the understanding of the impact of human activities on the Earth's protective ozone layer. There are four major findings that each heighten the concern that chlorine and bromine containing chemicals can lead to a significant depletion of stratospheric ozone: (1) Antarctic ozone hole (the weight of evidence indicates that chlorinated and brominated chemicals are responsible for the ozone hole; (2) Perturbed arctic chemistry (the same potentially ozone destroying processes were identified in the Arctic stratosphere); (3) Long term ozone decreases; and (4) Model limitations (gaps in theoretical models used for assessment studies).

Source record↗

The Connection between Model Performance on the CCMVal Transport Diagnostics and Simulated Sensitivity of Ozone to Chlorine Change

The chemistry climate models that contributed simulations for past and future ozone evolution to the 2010 Scientific Assessment of Ozone Depletion were subject to extensive evaluation by the SPARC (Stratospheric Processes and their Role in Climate) CCMVal (Chemistry-Climate Model Validation) activity. The sensitivity of ozone to changes in composition and climate varies among the models, but the relationship between these variations and the model evaluations of CCMVal is not obvious. We have learned that the transport evaluation can be used to interpret the comparisons between observed and simulated columns of chlorine reservoirs, hydrochloric acid (HCl) and chlorine nitrate (ClONO2); these comparisons were part of the CCMVal evaluation of chemistry. The simulations with best performance on the transport diagnostics most faithfully reproduce the evolution and seasonal variation of the chlorine reservoirs as observed at NDACC (Network for Detection of Atmospheric Composition Change) stations (NyAlesund 78.9N, Kiruna 67.8N, Harestua 60.2N, Jungfraujoch 46.6N, Toronto 43.6N, Kitt Peak 31.9N, Izana 28.3N, Mauna Loa 19.5N, Lauder 45S and Arrival Heights 77.8S). In the simulations, the HCl in the lower stratosphere depends on total inorganic chlorine (Cly) and partitioning between HCl and ClON02. Total inorganic chlorine depends on the fractional release of chlorine from source gases, and ratio of ClON02 to HCl is inversely dependent on methane and varies quadratically with ozone. Simulated HCl from various models may agree with observations even though Cly is in error, partitioning is in error, or both. Simulated ozone sensitivity to chlorine is shown to be greater for models that produce larger values of chlorine nitrate for background chlorine levels, and vice versa. Comparisons with the NDACC data show why the models with 'best' transport have similar sensitivity to chlorine change. The realistic evolution of the simulated HCl and ClONO2 columns suggests realistic levels of Cly in the lower atmosphere. In addition, the wide range values for the sensitivity of ozone to chlorine obtained from the CCMVal simulations is explained by the wide range in lower atmospheric columns of ClONO2 and the concomitant wide range of levels for chlorine monoxide.

Douglass, Anne↗

The effect of remnant CdSe layers on the performance of CdSeTe/CdTe photovoltaic devices

Thin film CdTe-based photovoltaic devices have achieved high efficiency above 22 %. The recent improvement in efficiency is due to Se alloying in the CdTe absorbers to form a CdSeTe/CdTe structure. The subsequent band gap grading increases the short circuit current density. The Se can be introduced by depositing a precursor thin film of either CdSe or a CdSeTe alloy and then diffusing the Se into the CdTe during the high temperature cadmium chloride activation process. Using CdSe is preferred because it is easier to control the Se concentration. However, during fabrication of the CdSeTe/CdTe devices, the CdSe thickness needs to be precisely controlled to prevent the retention of a CdSe remnant layer after the activation treatment. Retention of a remnant CdSe layer causes a dramatic reduction in device efficiency. In this work, we show that the reduction in efficiency is caused by a number of factors. The remnant CdSe layer is n-type which moves the position of the p-n junction. Also, it is widely thought that the CdSe remnants are photo-inactive. In this work, we clarify that the individual CdSe grains are actually highly photo-active. However, the grain sizes in the CdSe remnant and the adjacent CdSeTe layer are very small resulting in a high grain boundary area. Although the grain boundaries are passivated with chlorine, cathodoluminescence imaging and electrical measurements show that this is only partially effective. Also, EQE measurements show that the remnant CdSe causes parasitic absorption. Overall, the remnant CdSe layer causes a reduction in short circuit current density and device efficiency. The thickness of the CdSe precursor layer and the cadmium chloride activation process conditions must be precisely optimised to ensure that all the CdSe is consumed and inter-diffused to form the CdSeTe alloy for highest efficiency devices.

CdSe remnant↗

High-energy and low-cost membrane-free chlorine flow battery

Abstract Grid-scale energy storage is essential for reliable electricity transmission and renewable energy integration. Redox flow batteries (RFB) provide affordable and scalable solutions for stationary energy storage. However, most of the current RFB chemistries are based on expensive transition metal ions or synthetic organics. Here, we report a reversible chlorine redox flow battery starting from the electrolysis of aqueous NaCl electrolyte and the as-produced Cl 2 is extracted and stored in the carbon tetrachloride (CCl 4 ) or mineral spirit flow. The immiscibility between the CCl 4 or mineral spirit and NaCl electrolyte enables a membrane-free design with an energy efficiency of >91% at 10 mA/cm 2 and an energy density of 125.7 Wh/L. The chlorine flow battery can meet the stringent price and reliability target for stationary energy storage with the inherently low-cost active materials (~$5/kWh) and the highly reversible Cl 2 /Cl − redox reaction.

25 ENERGY STORAGE↗

The effect of environmental initiatives on NASA specifications and standards activities

The NASA Operational Environment Team (NOET) has conducted a survey of NASA centers specifications and standards that require the use of Ozone Depleting Substances (ODS's) (Chlorofluorocarbons (CFCs), Halons, and chlorinated solvents). The results of this survey are presented here, along with a pathfinder approach utilized at Marshall Space Flight Center (MSFC) to eliminate the use of ODS's in targeted specifications and standards. Presented here are the lessons learned from a pathfinder effort to replace CFC-113 in a significant MSFC specification for cleaning and cleanliness verification methods for oxygen, fuel and pneumatic service, including Shuttle propulsion elements.

Griffin, Dennis↗

Produced water softening using high-pH catholyte from brine electrolysis: reducing chemical transportation and environmental footprints

This study evaluates the benefits of using brine electrolysis for generating caustic soda (NaOH) and free chlorine for on-site produced water (PWs 1 ) treatment. A two-compartment electrochemical cell was shown to generate NaOH solutions (pH > 12, faradic efficiency 93%) and chlorine (faradic efficiency 32%) from a NaCl brine solution at a current density of 10 mA/cm2. The catholyte was used for softening field-collected PWs. The degree of Mg removal depends mostly on the catholyte/PW mixture pH with pH 11 achieving >90% removal. Ca removal is poor (<10%) due to low bicarbonate alkalinity in the PWs. Soda ash alone at a dose equivalent to the total hardness of the PWs helps CaCO3 precipitation and Ca removal (>90%). The combined treatment of the catholyte and a reduced quantity of soda ash achieves better or comparable Ca removal compared to the full stoichiometric amounts of soda ash alone. Ba and Sr removal patterns closely follow those of Ca, suggesting co-precipitation of these cations as the primary removal mechanism. Organic removal is negligible during chemical softening; however, activated carbon filtration achieves >90% of total organic carbon (TOC) removal in all PWs. A treatment scheme is proposed for field generation of caustic soda and chlorine from PW. The economic analysis demonstrates the significant cost-effectiveness of the approach compared to purchasing the NaOH.

42 ENGINEERING↗

Non-reactive facet specific adsorption as a route to remediation of chlorinated organic contaminants

The present work quantifies metal-contaminant interactions between palladium substrates and three salient chlorinated organic contaminants, namely trichloroethylene 1,3,5-trichlorobenzene (TCB), and 3,3′,4,4′-tetrachlorobiphenyl (PCB77). Given that Pd is one of the conventional catalytically active materials known for contaminant removal, maximizing catalytic efficiency through optimal adsorption dynamics reduces the cost of remediation of contaminants that are persistent water pollutants chronically affecting public health. Adsorption efficiency analyses from all-atom molecular dynamics (MD) simulations advance the understanding of reaction mechanisms available from density functional theory (DFT) calculations to an extractable feature scale that can fit the parametric design of supported metal catalytic systems and feed into high throughput catalyst selection. Data on residence time, site-specific adsorption, binding energies, packing geometries, orientation profiles, and the effect of adsorbate size show the anomalous behaviour of organic contaminant adsorption on the undercoordinated {110} surface as compared to the {111} and {100} surfaces. The intermolecular interaction within contaminants from molecular dynamics simulation exhibits refreshing results than ordinary single molecule density functional theory calculation. Since complete adsorption and dechlorination is an essential step for chlorinated organic contaminant remediation pathways, the presented profiles provide essential information for designing efficient remediation systems through facet-controlled palladium nanoparticles.

Guo, Hao↗

Gold Catalysts Synthesized Using a Modified Incipient Wetness Impregnation Method for Propylene Epoxidation

Propylene epoxidation in the presence of oxygen and hydrogen were measured for a series of Au/TS-1 catalysts prepared by a modified incipient wetness impregnation (mIWI) method. This method enables precise control of the Au : Ti ratio in the Au/TS-1 catalysts. The optimized Au/TS-1 catalyst exhibited 12 % propylene conversion, 87 % PO selectivity, and 25 % hydrogen efficiency. The particle size of gold nanoparticles prepared by the modified IWI was between 2 and 3 nm, as demonstrated by XRD patterns, STEM images, and X-ray absorption spectroscopy at the Au L(3)edge. XPS spectra showed that the surface species on the catalysts were similar. UV-Vis spectra suggested that in the modified IWI method, the chlorine ligands in Au(Cl)(4)(-)were replaced by hydroxyl groups, which contributes to form small gold nanoparticles. Kinetic studies showed that the active sites of Au(mIWI)/TS-1 are similar to the Au(DP)/TS-1 prepared by deposition precipitation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Components Cleaning Facility West SWMU 030 2024 Annual Long Term Monitoring Report

This document presents and summarizes the 2024 groundwater monitoring activities and the results of a localized direct-push technology investigation at CCF West in order to monitor the natural attenuation of chlorinated volatile organic compound (CVOC)-affected groundwater with concentrations above the state of Florida Chapter 62-777, Florida Administrative Code, groundwater cleanup target levels.

Richard Smith↗

Off-Gas Design and Testing from Advanced Chlorination Process

Chlorination of Zr alloy cladding with sulfur-chloride reagents is being considered as a means of separating the main metal from alloying elements, imbedded U, actinides, and fission and activation products to purify the Zr. This would allow the Zr to be disposed of as low-level nuclear waste or possibly be recycled. A multistage process was developed that involves several steps and waste streams. Recycling of sulfur-chloride reagents S 2 Cl 2 and SOCl 2 is planned to minimize the waste stream. The generation of off-gas and entrainment of volatiles is anticipated to be minimized. However, given the complex nature of spent nuclear fuel (SNF), some volatile components will be generated, including the solvents themselves; Cl 2 used for the regeneration of S 2 Cl 2 ; volatile fission product chlorides, such as Sb and 3 H; and chlorinated alloying components, such as Sn, Nb, Fe, and Mo. This report discusses the chemical phenomena that might give rise to volatile species and their planned capture. The volatility of the transition metals will depend on their oxidation state and the compounds that are formed, such as Zr tritide. Loading radionuclides in the process off-gas will depend on the inputs to the process. For instance, processing separated Zr to reduce waste will have a much lower loading of radionuclides than if alternative chlorination were used for decladding SNF. Much of the volatile process streams will be part of the solvent recycling, which may involve online scrubbing. Generally, a caustic scrubber should be included in the off-gas to remove acidic vapors (e.g., Cl 2 , SOCl 2 ). The decontamination procedures for removing these species could involve pretreatment (i.e., heating) options or reduction by contact with H 2 . This report discusses these options along with a framework for testing these alternatives in future experiments. Technologies for off-gas capture will leverage those developed in the Materials Recovery and Waste Forms program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Components Refurbishment and Chemical Analysis Facility, Hot Spot 1 SWMU #041 Year 3 Annual Performance Monitoring Report Kennedy Space Center, Florida

This Year 3 Annual Performance Monitoring Report (PMR) presents the operations, maintenance, and monitoring activities for the Hydraulic Containment System (HCS) Interim Measure (IM) at the Components Refurbishment and Chemical Analysis (CRCA) facility located at John F. Kennedy Space Center (KSC), Florida. The primary objective of the HCS is to attain hydraulic control of the dissolved-phase chlorinated volatile organic compound (CVOC) plume, with the secondary objective to reduce concentrations of CVOCs in the high-concentration plume to support transition to monitored natural attenuation (MNA). CRCA has been designated Solid Waste Management Unit 041 under the KSC Resource Conservation and Recovery Act Corrective Action Program. The timeframe for activities documented in this Year 3 PMR extends from September 2021 through October 2022. Baseline sampling activities were completed in June 2019, and full-scale startup of the HCS IM was completed in July-August 2019. The operational runtime of the HCS for the Year 3 reporting period was approximately 91%, with the majority of downtime attributed to system maintenance and repair. This is generally consistent with Year 1 and Year 2 runtimes of 85% and 92%, respectively. To help reduce downtime, an anti-scaling amendment, Redux 390, has been used to reduce scaling and help maintain system design parameters. Over nine million gallons of groundwater were treated during Year 3 of HCS operations, and concentrations of the site’s contaminants of concern (trans-1,2-dichloroethene and vinyl chloride) have been reduced by over 97%. This PMR describes the activities that were performed during Year 3 to operate and monitor the HCS IM, which includes three extraction wells, seven injection wells, and conveyance piping to a modular structure containing the control panel and an air stripper. Influent and effluent sampling results from the air stripper show that the system is operating as designed and is reducing concentrations of contaminants of concern to below detection limits. In addition to HCS operation, this PMR also discusses performance monitoring that has been implemented to assess progress of the HCS IM and overall plume conditions through scheduled groundwater (quarterly and semi-annual) and sub-slab soil gas (quarterly) sampling and analysis. Two ambient air samples were also collected on a quarterly basis in the vicinity of the modular structure and the paved driveway east of the Solvent Reclamation Area during routine operation and maintenance (O&M) activities to ensure safe breathing zone air quality for on-site personnel. All sub-slab soil gas and ambient air sampling conducted during the Year 3 operational period showed results below applicable regulatory air screening limits. Predictions made during the Year 2 groundwater model updates were in close correlation to post Year 3 plume conditions. Therefore, it can be assumed that the projected path remains valid for transition to MNA in one to two years of continuous HCS operation. The contents of this Year 3 PMR were presented during the February 2023 KSC Remediation Team meeting, where Team consensus was reached on several items including continued O&M of the HCS, and continued monitoring of groundwater, ambient air, and sub-slab soil gas. Replacement of MW0019 and VMP04 was also recommended, as well as additional direct-push technology sampling to further delineate the downgradient plume and confirm overall site-wide low-concentration plume boundaries. Sampling for per- and polyfluoroalkyl substances at CRCA is ongoing and will be submitted under separate cover.

K. Alex Murphy↗

Components Refurbishment and Chemical Analysis Facility, Hot Spot 1 Solid Waste Management Unit #041 Year 4 Annual Performance Monitoring Report Kennedy Space Center, Florida

This Year 4 Annual Performance Monitoring Report (PMR) presents the operations, maintenance, and monitoring activities for the Hydraulic Containment System (HCS) Interim Measure (IM) at the Components Refurbishment and Chemical Analysis (CRCA) facility located at John F. Kennedy Space Center (KSC), Florida. The primary objective of the HCS is to attain hydraulic control of the dissolved-phase chlorinated volatile organic compound (CVOC) plume, with the secondary objective to reduce concentrations of CVOCs in the high-concentration plume to support transition to monitored natural attenuation (MNA). CRCA has been designated Solid Waste Management Unit 041 under the KSC Resource Conservation and Recovery Act Corrective Action Program. The timeframe for activities documented in this Year 4 PMR extends from November 2022 through September 2023. Baseline sampling activities were completed in June 2019, and full-scale startup of the HCS IM was completed in July-August 2019. The operational runtime of the HCS for the Year 4 reporting period was approximately 94%, with the majority of downtime attributed to associated groundwater sampling events, maintenance, and Hurricane Nicole. Almost five million gallons of groundwater were treated during Year 4 of HCS operations, and concentrations of the site’s contaminants of concern (trans-1,2-dichloroethene and vinyl chloride) have been reduced by over 99%. This PMR describes the activities that were performed during Year 4 to operate and monitor the HCS IM, which includes three extraction wells, seven injection wells, and conveyance piping to a modular structure containing the control panel and an air stripper. Influent and effluent sampling results from the air stripper show that the system is operating as designed and is reducing concentrations of contaminants of concern to below detection limits. In addition to HCS operation, this PMR also discusses performance monitoring that has been implemented to assess progress of the HCS IM and overall plume conditions through scheduled groundwater (quarterly and semi-annual) and sub-slab soil gas (quarterly) sampling and analysis. Two ambient air samples were also collected on a quarterly basis in the vicinity of the modular structure and the paved driveway east of the Solvent Reclamation Area during routine operation and maintenance (O&M) activities to ensure safe breathing zone air quality for on-site personnel. All sub-slab soil gas and ambient air sampling conducted during the Year 4 operational period showed results below applicable regulatory air screening limits. Predictions made during the Year 2 groundwater model updates were in close correlation to post Year 4 plume conditions. A supplemental DPT study conducted in 2022 and 2023. This study indicated that low-concentration plume conditions, where concentrations exceed State of Florida Groundwater Cleanup Target Levels, expanded westward to Kennedy Parkway North and northward to the vicinity of the railroad tracks. Based on these results, recommendations were made to install 14 wells to monitor the downgradient and boundary conditions of the expanded LCP. The contents of this Year 4 PMR were presented during the November 2023 KSC Remediation Team meeting, where Team consensus was reached on several items including continued O&M of the HCS, and continued monitoring of groundwater, ambient air, and sub-slab soil gas. Sampling for per- and polyfluoroalkyl substances at CRCA is ongoing and will be submitted under separate cover.

K. Alex Murphy↗

Results of the International Energy Agency Bioenergy Round Robin on the Analysis of Heteroatoms in Biomass Liquefaction Oils

A round robin study evaluating the analysis of biomass liquefaction oils (BLOs) from fast pyrolysis and hydrothermal liquefaction (HTL) was performed, involving fifteen laboratories in seven countries in order to assess the current status of analytical techniques for the determination of nitrogen, sulfur, and chlorine content in BLOs and evaluate potential differences in origin (i.e. fast pyrolysis vs HTL). The BLOs were produced from a range of feedstocks including pine, mixed softwoods, forest residues, micro-algae, miscanthus, and wheat straw to cover a variety in nitrogen, sulfur, and chlorine content and speciation. Nine samples were distributed, comprised of eight separate BLOs and one blind duplicate produced by five producers. The samples were analyzed for water, carbon, hydrogen, nitrogen, sulfur, and chlorine content. No analytical test method was mandated; laboratories were encouraged to utilize whichever method they determined would be most applicable, relying on the existing body of BLO literature as a guide. The results of this round robin study are presented in this paper. The results of the carbon, hydrogen, and water measurements as reference analyses had relative standard deviations (2.9%, 3.5, and 5.6%, respectively) that were comparable to those found in past round robin studies on fast pyrolysis bio-oil. The analysis of nitrogen, sulfur, and chlorine showed higher levels of variability. Laboratories mostly chose the same method for water, carbon, hydrogen and nitrogen determination whereas there were a variety of methods chosen for sulfur and chlorine determination. The results suggest that specific analytical methods for the determination of nitrogen, sulfur, and chlorine should be further refined to ensure reproducible and accurate results for BLO analysis due to their importance on emissions, material selection, and catalyst activity.

Biomass, IEA Bioenergy, pyrolysis, hydrothermal li↗

Applications of chemiluminescence to bacterial analysis

Luminol chemiluminescence method for detecting bacteria was based on microbial activation of the oxidation of the luminol monoanion by hydrogen peroxide. Elimination of the prior lysing step, previously used in the chemiluminescence technique, was shown to improve considerably the reproducibility and accuracy of the method in addition to simplifying it. An inexpensive, portable photomultiplier detector was used to measure the maximum light intensity produced when the sample is added to the reagent. Studies of cooling tower water show that the luminol chemiluminescence technique can be used to monitor changes in viable cell population both under normal conditions and during chlorine treatment. Good correlation between chemiluminescence and plate counts was also obtained in the analysis of process water used in paper mills. This method showed good potential for monitoring the viable bacteria populations in activated sludge used in waste treatment plants to digest organic matter.

Searle, N. D.↗