Search NASA⌕ Search

SEARCH · Search NASA

Results for “clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Search for evidence of a clock related to the solar 154 day complex of periodicities

Evidence that has recently been compiled (Bai and Sturrock 1991) indicates that the enigmatic 154-day periodicity in solar activity may be viewed as part of a complex of periodicities that are approximate multiples of 25.8 days, suggesting that the Sun contains a 'clock' with frequency in the range 440 to 463 nano Hz. The clock may comprise either an oscillator or a rotator, each of which may be either real or virtual. We have reconsidered a previous spectrum analysis of the Zurich sunspot-number sequence by Knight, Schatten, and Sturrock (1979) which revealed a sharp, persistent and significant periodicity with a period of 12.072 days, corresponding to a frequency of about 958.8 nano Hz. This periodicity may be regarded as the (second) upper sideband of the second harmonic (2nu(sub R) + 2nu(sub E)) of a fundamental frequency of 447.7 nano Hz that is clearly within the search band. In this expression, nu(sub R) is the sidereal frequency of the hypothetical rotator and nu(sub E) is the frequency (31.69 nano Hz) of the Earth in its orbital motion around the Sun. In analyzing sunspot area data derived from the Greenwich data set, and on noting that any frequency is defined only to within the Nyquist frequency, we find clear evidence not only for the upper sideband of the second harmonic, but also for the second harmonic (2nu(sub R)) and the lower sideband of the second harmonic (2nu(sub R) - 2nu(sub E)). There is no strong peak at the fundamental frequency in the Greenwich data, but there is in the Zurich sunspot data. The effect of a linear oscillator is, to the lowest order in the amplitude, the same as the combined effect of two rotators of opposite polarities. A rotator that has arbitrary orientation with respect to the ecliptic may influence the outer layers of the Sun and thereby modulate the occurrence of solar activity such as sunspots. By analyzing a simple model, we find that such a rotator would influence surface activity in such a way that the spectrum of a 'signal' (such as the record of sunspots), as seen from the Earth, would contain components with frequencies that are certain integral combinations of nu(sub R) and nu(sub E). The amplitudes of the various components depend sensitively on theta, the angle between the axis of the rotator and the axis of the Earth's orbital motion. This simple model therefore offers a kinematical (but not dynamical) interpretation of the sunspot spectrum. The present analysis, while offering support of our conjectures that the Sun contains a clock that regulates the 154-day complex of periodicities, cannot distinguish between an osillator or a rotator (that might be a traveling wave), nor between a real rotator or a virtual rotator (that might be an apparent traveling wave due to the aliasing effect of an oscillator in a rotating system). Further analysis of sunspot and other data sets will be required to confirm the existence of such clock and (if it is real) to determine its physical nature.

Sturrock, P. A.↗

Timescale algorithms combining cesium clocks and hydrogen masers

The United States Naval Observatory (USNO) atomic timescale, formerly based on an ensemble of cesium clocks, is now produced by an ensemble of cesium clocks and hydrogen masers. In order to optimize stability and reliability, equal clock weighting has been replaced by a procedure reflecting the relative, time-varying noise characteristics of the two different types of clocks. Correlation of frequency drift is required, and residual drift is avoided by the eventual complete deweighting of the masers.

Lee A. Breakiron↗

Frequency stability of GPS NAVSTAR block 1 and block 2 on-orbit clocks

Analysis of the frequency stability of the on-orbit NAVSTAR clocks os performed by the Naval Research Laboratory. The frequency stability is presented for sample times of one day to 30 days. Composite frequency stability profiles are presented for Block 1 and Block 2 NAVSTAR clocks. Several NAVSTAR cesium clocks show frequency stabilities of a few parts in 10^(14) for long sample times. Time-domain noise-process analysis shows the dominant noise type to be white frequency noise for sample times of one to ten days. The non-stationary stochastic behavior of one of the cesium clocks, illustrated by its frequency stability history, shows that the frequency stability is not always time-invariant.

Thomas B. Mccaskill↗

Experimental comparison of time synchronization techniques by means of light signals and clock transport on the rotating earth

An experiment was conducted to investigate the equivalence of two methods of time transfer in a noninertial reference frame: by means of an electromagnetic signal using laser light pulses and by means of the slow ground transport of a hydrogen maser atomic clock. The experiment may also be interpreted as an investigation of whether the one-way speeds of light in the east-west and west-east directions on the rotating earth are the same. The light pulses were sent from a laser coupled to a telescope at the NASA Goddard Optical Research Facility (GORF) in Greenbelt, Maryland to the U.S. Naval Observatory (USNO) in Washington, DC. The optical path was made possible by a 30-cm flat mirror on a water tower near GORF and a 25-cm flat mirror on top of the Washington National Cathedral near USNO. The path length was 26.0 km with an east-west component of 20.7 km. The pulses were reflected back over the same path by a portable array of corner cube reflectors. The transmission and return times were measured with a stationary Sigma Tau hydrogen maser and a University of Maryland event timer at GORF, while the times of reflection were measured with a similar maser and event timer combination carefully transported to USNO. Both timekeeping systems were housed in highly insulated enclosures and were maintained at constant temperatures to within +/- 0.1 C by microprocessor controllers. The portable system was also protected from shock and vibration by pneumatic supports. The difference delta(T) between the directly measured time of reflection according to the portable clock and the time of reflection calculated from the light pulse signal times measured by the stationary clock was determined. For a typical trip delta(T) is less than 100 ps and the corresponding limit on an anisotropy of the one-way speed of light is delta(c/c) is less than 1.5 x 10(exp -6). This the only experiment to date in which two atomic clocks were calibrated at one location, one was slowly transported to the other end of a path, and the times of transmission, reflection, and return of short light pulses sent in different directions along the path were registered.

Nelson, R. A.↗

Time scale algorithms for an inhomogeneous group of atomic clocks

Through the past 17 years, the time scale requirements at the National Research Council (NRC) have been met by the unsteered output of its primary laboratory cesium clocks, supplemented by hydrogen masers when short-term stability better than 2 x 10(exp -12)tau(sup -1/2) has been required. NRC now operates three primary laboratory cesium clocks, three hydrogen masers, and two commercial cesium clocks. NRC has been using ensemble averages for internal purposes for the past several years, and has a realtime algorithm operating on the outputs of its high-resolution (2 x 10(exp -13) s at 1 s) phase comparators. The slow frequency drift of the hydrogen masers has presented difficulties in incorporating their short-term stability into the ensemble average, while retaining the long-term stability of the laboratory cesium frequency standards. We report on this work on algorithms for an inhomogeneous ensemble of atomic clocks, and on our initial work on time scale algorithms that could incorporate frequency calibrations at NRC from the next generation of Zacharias fountain cesium frequency standards having frequency accuracies that might surpass 10(exp -15), or from single-trapped-ion frequency standards (Ba+, Sr+,...) with even higher potential accuracies. The requirements for redundancy in all the elements (including the algorithms) of an inhomogeneous ensemble that would give a robust real-time output of the algorithms are presented and discussed.

Jacques, C.↗

European plans for new clocks in space

An outline of the future European space research program where precise clocks are necessary is presented, pointing out how space applications are posing impressive requirements as regards clock mass, power, ruggedness, long life, accuracy and, in some cases, spectral purity. The material presented was gathered in some laboratories; useful information was obtained from the Space Agencies of France (CNES), Germany (DARA) and Italy (ASI), but the bulk is coming from a recent exercise promoted inside ESA (the European Space Agency) and aimed to prefigure space research activities at the beginning of the next millennium. This exercise was called Horizon 2000 plus; the outcomings were summarized in two reports, presented by ESA in may 1994. Precise clocks and time measurements are needed not only for deep-space or out-ward space missions, but are essential tools also for Earth oriented activities. In this latter field, the European views and needs were discussed in October 1994, in a meeting organized by ESA and devoted to Earth Observation problems. By a scrutiny of these reports, an analysis was performed on the missions requiring a precise clock on board and the driving requirements were pointed out, leading to a survey of the necessary PTTI developments that, to some extent, are in the realm of possibility but that pose serious challenges. In this report the use of frequency standards in the satellite navigation systems is not considered.

Leschiutta, Sigfrido M.↗

Atomic Clocks and Variations of the FIne Structure Constant

We describe a new test for possible variations of the fine structure constant alpha by comparisons of rates between clocks based on hyperfine transitions in alkali atoms with different atomic number Z. H-maser, Cs, and Hg(+) clocks have a different dependence on alpha via relativistic contributions of order (Z-alpha)(sup 2). Recent H-maser vs Hg(+) clock comparison data improve laboratory limits on a time variation by 100-fold to give dot-alpha less than or equal to 3.7 x 10(exp -14)/yr. Future laser cooled clocks (Be(+), Rb, Cs, Hg(+), etc.), when compared, will yield the most sensitive of all tests for dot-alpha/alpha.

Prestage, John D.↗

Biochemical basis for the biological clock

NADH oxidases at the external surface of plant and animal cells (ECTO-NOX proteins) exhibit stable and recurring patterns of oscillations with potentially clock-related, entrainable, and temperature-compensated period lengths of 24 min. To determine if ECTO-NOX proteins might represent the ultradian time keepers (pacemakers) of the biological clock, COS cells were transfected with cDNAs encoding tNOX proteins having a period length of 22 min or with C575A or C558A cysteine to alanine replacements having period lengths of 36 or 42 min. Here we demonstrate that such transfectants exhibited 22, 36, or 40 to 42 h circadian patterns in the activity of glyceraldehyde-3-phosphate dehydrogenase, a common clock-regulated protein, in addition to the endogenous 24 h circadian period length. The fact that the expression of a single oscillatory ECTO-NOX protein determines the period length of a circadian biochemical marker (60 X the ECTO-NOX period length) provides compelling evidence that ECTO-NOX proteins are the biochemical ultradian drivers of the cellular biological clock.

NASA Discipline Cell Biology↗

The mammalian retina as a clock

Many physiological, cellular, and biochemical parameters in the retina of vertebrates show daily rhythms that, in many cases, also persist under constant conditions. This demonstrates that they are driven by a circadian pacemaker. The presence of an autonomous circadian clock in the retina of vertebrates was first demonstrated in Xenopus laevis and then, several years later, in mammals. In X. laevis and in chicken, the retinal circadian pacemaker has been localized in the photoreceptor layer, whereas in mammals, such information is not yet available. Recent advances in molecular techniques have led to the identification of a group of genes that are believed to constitute the molecular core of the circadian clock. These genes are expressed in the retina, although with a slightly different 24-h profile from that observed in the central circadian pacemaker. This result suggests that some difference (at the molecular level) may exist between the retinal clock and the clock located in the suprachiasmatic nuclei of hypothalamus. The present review will focus on the current knowledge of the retinal rhythmicity and the mechanisms responsible for its control.

Review Literature↗

Origin of the Eumetazoa: testing ecological predictions of molecular clocks against the Proterozoic fossil record

Molecular clocks have the potential to shed light on the timing of early metazoan divergences, but differing algorithms and calibration points yield conspicuously discordant results. We argue here that competing molecular clock hypotheses should be testable in the fossil record, on the principle that fundamentally new grades of animal organization will have ecosystem-wide impacts. Using a set of seven nuclear-encoded protein sequences, we demonstrate the paraphyly of Porifera and calculate sponge/eumetazoan and cnidarian/bilaterian divergence times by using both distance [minimum evolution (ME)] and maximum likelihood (ML) molecular clocks; ME brackets the appearance of Eumetazoa between 634 and 604 Ma, whereas ML suggests it was between 867 and 748 Ma. Significantly, the ME, but not the ML, estimate is coincident with a major regime change in the Proterozoic acritarch record, including: (i) disappearance of low-diversity, evolutionarily static, pre-Ediacaran acanthomorphs; (ii) radiation of the high-diversity, short-lived Doushantuo-Pertatataka microbiota; and (iii) an order-of-magnitude increase in evolutionary turnover rate. We interpret this turnover as a consequence of the novel ecological challenges accompanying the evolution of the eumetazoan nervous system and gut. Thus, the more readily preserved microfossil record provides positive evidence for the absence of pre-Ediacaran eumetazoans and strongly supports the veracity, and therefore more general application, of the ME molecular clock.

NASA Discipline Evolutionary Biology↗

System and method for clock synchronization and position determination using entangled photon pairs

A system and method for clock synchronization and position determination using entangled photon pairs is provided. The present invention relies on the measurement of the second order correlation function of entangled states. Photons from an entangled photon source travel one-way to the clocks to be synchronized. By analyzing photon registration time histories generated at each clock location, the entangled states allow for high accuracy clock synchronization as well as high accuracy position determination.

Shih, Yanhua↗

Hg-201 (+) CO-Magnetometer for HG-199(+) Trapped Ion Space Atomic Clocks

Local magnetic field strength in a trapped ion atomic clock is measured in real time, with high accuracy and without degrading clock performance, and the measurement is used to compensate for ambient magnetic field perturbations. First and second isotopes of an element are co-located within the linear ion trap. The first isotope has a resonant microwave transition between two hyperfine energy states, and the second isotope has a resonant Zeeman transition. Optical sources emit ultraviolet light that optically pump both isotopes. A microwave radiation source simultaneously emits microwave fields resonant with the first isotope's clock transition and the second isotope's Zeeman transition, and an optical detector measures the fluorescence from optically pumping both isotopes. The second isotope's Zeeman transition provides the measure of magnetic field strength, and the measurement is used to compensate the first isotope's clock transition or to adjust the applied C-field to reduce the effects of ambient magnetic field perturbations.

Burt, Eric A.↗

Helium Pressure Shift of the Hyperfine Clock Transition in Hg-201(+)

There are two stable odd isotopes of mercury with singly ionized hyperfine structure suitable for a microwave atomic clock: Hg-199(+) and Hg-201(+). We are investigating the viability of a trapped ion clock based on Hg-201(+) in a configuration that uses a buffer gas to increase ion loading efficiency and counter ion heating from rf trapping fields. Traditionally, either helium or neon is used as the buffer gas at approx. 10(exp -5) torr to confine mercury ions near room temperature. In addition to the buffer gas, other residual background gasses such as H2O, N2, O2, CO, CO2, and CH2 may be present in trace quantities. Collisions between trapped ions and buffer gas or background gas atoms/molecules produce a momentary shift of the ion clock transition frequency and constitute one of the largest systematic effects in this type of clock. Here we report an initial measurement of the He pressure shift in Hg-201(+) and compare this to Hg-199(+).

Larigani, S. Taghavi↗

Deep Space Atomic Clock Technology Demonstration Mission Onboard Navigation Analog Experiment

The timing and frequency stability provided by the Deep Space Atomic Clock (DSAC) is on par with the Deep Space Network’s ground clocks, and will enable one-way radiometric measurements with accuracy equivalent to current two-way tracking data. A demonstration unit of the clock will be launched into low Earth orbit in late 2016/early 2017 for the purpose of validating DSAC’s performance in the space environment. GPS data collected throughout the mission will be utilized not only for precise clock estimation, but also as a proxy for deep space tracking data. Through careful processing of GPS Doppler data and limited modeling fidelity representative of onboard capabilities, onboard orbit solutions can be compared to higher-fidelity ground solutions, demonstrating DSAC’s viability as an onboard navigation instrument in conditions typical for a low altitude Mars orbiter.

Seubert, Jill↗

Results of the Deep Space Atomic Clock Deep Space Navigation Analog Experiment

The timing and frequency stability provided by the Deep Space Atomic Clock (DSAC) is almost comparable with the Deep Space Network’s ground clocks, and will enable one-way radiometric measurements with accuracy equivalent to cur- rent two-way tracking data. A demonstration unit of the clock was launched into low Earth orbit on June 25, 2019, for the purpose of validating DSAC’s perfor- mance in the space environment. GPS data collected throughout the mission was utilized not only for precise clock estimation, but also as a proxy for deep space tracking data to conduct the Deep Space Navigation Analog Experiment. Through careful processing of GPS Doppler data and limited modeling fidelity representa- tive of deep space navigation capabilities, the analog orbit solutions are compared to higher-fidelity solutions, demonstrating DSAC’s viability as a navigation instru- ment in conditions typical for a low altitude Mars orbiter.

Stuart, Jeffrey↗

Deep Space Atomic Clock Technology Demonstration Mission Results

The Deep Space Atomic Clock (DSAC), a NASA Technology Demonstration Mission, was launched into low-Earth orbit on June 25, 2019 as a hosted payload aboard General Atomics’ Orbital Test Bed (OTB) spacecraft. The DSAC mission has been conducting a two-year demonstration of a mercury ion atomic clock to characterize its space-based performance and to validate its utility for deep space navigation and radio science. Analysis of the collected data using JPL’s GIPSY-OASIS software has shown DSAC’s AD at one-day to be near 310-15; much better than required AD of 210-14. Such low spacecraft clock errors will enable one-way radiometric tracking data with precision equivalent to or better than current-day two way tracking data, allowing a shift to a more efficient and flexible one-way deep space navigation architecture. To verify this, an analog deep space navigation experiment was performed using JPL’s operational navigation software (Monte). The experiment recovered orbit solutions with reduced data sets and geometric variations that are more representative of deep space missions, and showed that orbit determination using DSAC derived data is on par with more traditional two-way datatypes. As a technology demonstrator, DSAC’s development focus has been on maturing the mercury ion trap clock technology rather than achieving the smallest size, weight, and power (SWaP). Over the course of DSAC’s development the project has identified numerous improvements that could be made to significantly reduce SWaP for DSAC’s next version. Indeed, DSAC-2 was recently selected by NASA for further demonstration on the VERITAS mission to Venus. This work will review the DSAC technology, mission, and results from its two-year mission.

Wang, Rabi↗

Using Pulsars For Clock Steering and Time Transfer

As we prepare for extended missions on the Moon and in cislunar space, precise time synchronization between lunar and terrestrial clocks becomes increasingly critical for navigation, communication, and science measurements. One promising technique is the use of millisecond pulsars, which are highly magnetized, rapidly rotating neutron stars emitting beams of electromagnetic radiation. These celestial clocks offer extraordinary stability and precision, with rotational periods ranging from about 1 to 10 milliseconds and timing stability comparable to laboratory atomic clocks on Earth. Pulsars can provide a common time reference for clock comparisons, allowing time transfer independent of a communications link.

Spacecraft Communications, Command and Tracking↗

Gm-C filter and multi-phase clock circuit

Described herein is a power-efficient Gm-C filter, wherein the Gm-C filter includes several operational transconductance amplifiers (OTAs). In an example, at least two of the OTAs share a common bias current. Further, output of one of the OTAs is used to bias another one of the OTAs. Also described herein is a power-efficient clock generator circuit that is configured to output non-overlapping clock signals. The clock generator circuit includes a ring oscillator circuit, which includes several inverter stages. The clock generator circuit is well-suited for controlling operation of switches.

42 ENGINEERING↗