Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherence measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Yb:YAG Lasers for Space Based Remote Sensing

Diode pumped solid state lasers will play a prominent role in future remote sensing missions because of their intrinsic high efficiency and low mass. Applications including altimetry, cloud and aerosol measurement, wind velocity measurement by both coherent and incoherent methods, and species measurements, with appropriate frequency converters, all will benefit from a diode pumped primary laser. To date the "gold standard" diode pumped Nd laser has been the laser of choice for most of these concepts. This paper discusses an alternate 1 micron laser, the YB:YAG laser, and its potential relevance for lidar applications. Conceptual design analysis and, to the extent possible at the time of the conference, preliminary experimental data on the performance of a bread board YB:YAG oscillator will be presented. The paper centers on application of YB:YAG for altimetry, but extension to other applications will be discussed.

Ewing, J.J.↗

Prospects for VLBI Detection of Planets

Astrometric VLBI observations of radio stars are being made to connect the Hipparcos star catalog to the extragalactic radio reference frame. Typically, the antennas are moved between a star and a strong, compact reference source a few degrees away every 2-3 minutes. After correlation, the strong reference source fringes are used to determine the exact delay and rate of the weak radio star fringes, allowing the visibilities to be measured and coherently integrated for the duration of the experiment. As a result accurate astrometry has been possible on radio stars with flux densities as low as 2 mJy...

Jones, D. L.↗

Sub-Milliarcsecond Astrometry with Phase-Referenced VLBI

Astrometric VLBI observations of radio stars are being made to connect the Hipparcos optical reference frame and the extragalactic radio reference frame. The antennas are switched between a star and a strong, compact reference source a few degrees away every 2-3 minutes. After correlation, the strong reference source fringes are used to determine the exact delay and rate of the weak radio star fringes, allowing the visibilities to be measured and coherently integrated for the duration of the experiment. As a result accurate astrometry has been possible on radio stars with flux densities as low as 2 mJy. All five astrometric parameters (two positions, two proper motions, and one parallax) have been obtained for several stars, with formal errors and epoch-to-epoch residuals less than 1 milliarcsecond.

Jones, D. L.↗

Coherent Uncertainty Analysis of Aerosol Measurements from Multiple Satellite Sensors

Aerosol retrievals from multiple spaceborne sensors, including MODIS (on Terra and Aqua), MISR, OMI, POLDER, CALIOP, and SeaWiFS altogether, a total of 11 different aerosol products were comparatively analyzed using data collocated with ground-based aerosol observations from the Aerosol Robotic Network (AERONET) stations within the Multi-sensor Aerosol Products Sampling System (MAPSS, http://giovanni.gsfc.nasa.gov/mapss/ and http://giovanni.gsfc.nasa.gov/aerostat/). The analysis was performed by comparing quality-screened satellite aerosol optical depth or thickness (AOD or AOT) retrievals during 2006-2010 to available collocated AERONET measurements globally, regionally, and seasonally, and deriving a number of statistical measures of accuracy. We used a robust statistical approach to detect and remove possible outliers in the collocated data that can bias the results of the analysis. Overall, the proportion of outliers in each of the quality-screened AOD products was within 12%. Squared correlation coefficient (R2) values of the satellite AOD retrievals relative to AERONET exceeded 0.6, with R2 for most of the products exceeding 0.7 over land and 0.8 over ocean. Root mean square error (RMSE) values for most of the AOD products were within 0.15 over land and 0.09 over ocean. We have been able to generate global maps showing regions where the different products present advantages over the others, as well as the relative performance of each product over different landcover types. It was observed that while MODIS, MISR, and SeaWiFS provide accurate retrievals over most of the landcover types, multi-angle capabilities make MISR the only sensor to retrieve reliable AOD over barren and snow / ice surfaces. Likewise, active sensing enables CALIOP to retrieve aerosol properties over bright-surface shrublands more accurately than the other sensors, while POLDER, which is the only one of the sensors capable of measuring polarized aerosols, outperforms other sensors in certain smoke-dominated regions, including broadleaf evergreens in Brazil and South-East Asia.

remote sensing↗

Differential Absorption Measurements of Atmospheric Water Vapor with a Coherent Lidar at 2050.532 nm

Wind and water vapor are two major factors driving the Earth's atmospheric circulation, and direct measurement of these factors is needed for better understanding of basic atmospheric science, weather forecasting, and climate studies. Coherent lidar has proved to be a valuable tool for Doppler profiling of wind fields, and differential absorption lidar (DIAL) has shown its effectiveness in profiling water vapor. These two lidar techniques are generally considered distinctly different, but this paper explores an experimental combination of the Doppler and DIAL techniques for measuring both wind and water vapor with an eye-safe wavelength based on a solid-state laser material. Researchers have analyzed and demonstrated coherent DIAL water vapor measurements at 10 micrometers wavelength based on CO2 lasers. The hope of the research presented here is that the 2 gm wavelength in a holmium or thulium-based laser may offer smaller packaging and more rugged operation that the CO2-based approach. Researchers have extensively modeled 2 um coherent lasers for water vapor profiling, but no published demonstration is known. Studies have also been made, and results published on the Doppler portion, of a Nd:YAG-based coherent DIAL operating at 1.12 micrometers. Eye-safety of the 1.12 micrometer wavelength may be a concern, whereas the longer 2 micrometer and 10 micrometer systems allow a high level of eyesafety.

Koch, Grady J.↗

Dual-Doppler lidar measurement of winds in the JAWS experiment

The use of coherent Doppler lidar measurements for analysis of wind fields near airports was investigated during the Joint Airport Weather Studies (JAWS) project of NASA and NOAA. Periodic lidar scans were made with two 10.6-micron CO2-pulsed Doppler lidars spaced 15 km apart in order to calculate the Cartesian wind fields near Marshall Space Flight Center (MSFC). Analyses were also carried out for the flow behind gust fronts, with the desired flow fields corresponding both to surface winds measured by a Portable Automated Mesonet (PAM), and numerical models of Great Plains thunderstorm outflows. Comparison of low elevation scans carried out using the lidar instruments and a CP-4 Doppler radar showed distinct differences due to a bias toward weaker velocities in the radar measurements. The rms difference between the radar and the lidar measurements was 3.1 m/s. The experimental results were consistent with those of a previous study comparing Wave Propagation Laboratory (WPL) lidar with the CP-3 5.5-cm radar operated by the National Center for Atmospheric Research (NCAR).

Rothermel, J.↗

Wind Measurements with High Energy 2 Micron Coherent Doppler Lidar

A coherent Doppler lidar based on an injection seeded Ho:Tm:YLF pulsed laser was developed for wind measurements. A transmitted pulse energy over 75 mJ at 5 Hz repetition rate has been demonstrated. Designs are presented on the laser, injection seeding, receiver, and signal processing subsystems. Sample data of atmospheric measurements are presented including a wind profile extending from the atmospheric boundary layer (ABL) to the free troposphere.

Barnes, Bruce W.↗

Cross spectra between temperature and pressure in a constant area duct downstream of a combustor

The feasibility of measuring pressure temperature cross spectra and coherence and temperature-temperature cross spectra and coherence at spatially separated points along with pressure and temperature auto-spectra in a combustion rig was investigated. The measurements were made near the inlet and exit of a 6.44 m long duct attached to a J-47 combustor. The fuel used was Jet A. The cross spectra and coherence measurements show the pressure and temperature fluctuations correlate best at low frequencies. At the inlet the phenomena controlling the phase relationship between pressure and temperature could not be identified. However, at the duct exit the phase angle of the pressure is related to the phase angle of the temperature by the convected flow time delay.

Miles, J. H.↗

Cross spectra between temperature and pressure in a constant area duct downstream of a combustor

The feasibility of measuring pressure temperature cross spectra and coherence and temperature-temperature cross spectra and coherence at spatially separated points along with pressure and temperature auto-spectra in a combustion rig was investigated. The measurements were made near the inlet and exit of a 6.44 m long duct attached to a J-47 combustor. The fuel used was Jet A. The cross spectra and coherence measurements show the pressure and temperature fluctuations correlate best at low frequencies. At the inlet the phenomena controlling the phase relationship between pressure and temperature could not be identified. However, at the duct exit the phase angle of the pressure is related to the phase angle of the temperature by the convected flow time delay. Previously announced in STAR as N83-23116

Miles, J. H.↗

Coherent Raman spectroscopy for supersonic flow measurments

In collaboration with NASA/Langley Research Center, a truly nonintrusive and nonseeding method for measuring supersonic molecular flow parameters was proposed and developed at Colorado State University. The feasibility of this Raman Doppler Velocimetry (RDV), currently operated in a scanning mode, was demonstrated not only in a laboratory environment at Colorado State University, but also in a major wind tunnel at NASA/Langley Research Center. The research progress of the RDV development is summarized. In addition, methods of coherent Rayleigh-Brillouin spectroscopy and single-pulse coherent Raman spectroscopy are investigated, respectively, for measurements of high-pressure and turbulent flows.

She, C. Y.↗

Coherent Anti-Stokes Raman Spectroscopy (CARS) Measurements in Supersonic Combustors at NASA Langley Research Center

This paper describes the recent use of coherent anti-Stokes Raman spectroscopy (CARS) to study supersonic combustion at NASA Langley Research Center. CARS is a nonlinear optical measurement technique used to measure temperature and species mole fractions remotely in harsh environments. A CARS system has been applied to two different combustor geometries at NASA Langley. Both experiments used the same vitiated wind-tunnel facility to create an air flow that simulates flight at Mach numbers of 6 and 7 for the combustor inlet and both experiments used hydrogen fuel. In the first experiment, the hydrogen was injected supersonically at a 30-degree angle with respect to the incoming flow. In the second experiment, the hydrogen was injected sonically at normal incidence. While these injection schemes produced significantly different flow features, the CARS method provided mean temperature, N2, O2 and H2 maps at multiple downstream locations for both. The primary aim of these measurements was to provide detailed flowfield information for computational fluid dynamics (CFD) code validation.

Danehy, Paul M.↗

Preliminary Results of the NASA Beacon Receiver for Alphasat Aldo Paraboni TDP5 Propagation Experiment

NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have initiated a joint propagation campaign within the framework of the Alphasat propagation experiment to characterize rain attenuation, scintillation, and gaseous absorption effects of the atmosphere in the 40 GHz band. NASA GRC has developed and installed a K/Q-band (20/40 GHz) beacon receiver at the POLIMI campus in Milan, Italy, which receives the 20/40 GHz signals broadcast from the Alphasat Aldo Paraboni TDP#5 beacon payload. The primary goal of these measurements is to develop a physical model to improve predictions of communications systems performance within the Q-band. Herein, we describe the design and preliminary performance of the NASA propagation terminal, which has been installed and operating in Milan since May 2014. The receiver is based upon a validated Fast Fourier Transform (FFT) I/Q digital design approach utilized in other operational NASA propagation terminals, but has been modified to employ power measurement via a frequency estimation technique and to coherently track and measure the amplitude of the 20/40 GHz beacon signals. The system consists of a 1.2-m K-band and a 0.6-m Qband Cassegrain reflector employing synchronous open-loop tracking to track the inclined orbit of the Alphasat satellite. An 8 Hz sampling rate is implemented to characterize scintillation effects, with a 1-Hz measurement bandwidth dynamic range of 45 dB. A weather station with an optical disdrometer is also installed to characterize rain drop size distribution for correlation with physical based models.

propagation↗

Performance of the NASA Beacon Receiver for the Alphasat Aldo Paraboni TDP5 Propagation Experiment

NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have initiated a joint propagation campaign within the framework of the Alphasat propagation experiment to characterize rain attenuation, scintillation, and gaseous absorption effects of the atmosphere in the 40 gigahertz band. NASA GRC has developed and installed a K/Q-band (20/40 gigahertz) beacon receiver at the POLIMI campus in Milan, Italy, which receives the 20/40 gigahertz signals broadcast from the Alphasat Aldo Paraboni Technology Demonstration Payload (TDP) no. 5 beacon payload. The primary goal of these measurements is to develop a physical model to improve predictions of communications systems performance within the Q-band. Herein, we describe the design and preliminary performance of the NASA propagation terminal, which has been installed and operating in Milan since June 2014. The receiver is based upon a validated Fast Fourier Transform (FFT) I/Q digital design approach utilized in other operational NASA propagation terminals, but has been modified to employ power measurement via a frequency estimation technique and to coherently track and measure the amplitude of the 20/40 gigahertz beacon signals. The system consists of a 1.2-meter K-band and a 0.6-meter Q-band Cassegrain reflector employing synchronous open-loop tracking to track the inclined orbit of the Alphasat satellite. An 8 hertz sampling rate is implemented to characterize scintillation effects, with a 1-hertz measurement bandwidth dynamic range of 45 decibels. A weather station with an optical disdrometer is also installed to characterize rain drop size distribution for correlation with physical based models.

propagation↗

Telecommunication systems engineering

Telecommunication network concepts are discussed together with carrier-tracking loops employing the phase-lock principle, phase and Doppler measurements in two-way phase-coherent tracking systems, range measurements by phase-coherent techniques, and questions of phase-coherent detection with perfect reference signals and with noisy reference signals. The design of one-way and two-way phase-coherent communication systems is considered, giving attention to the optimal design of single-channel systems, the design of two-channel systems, and the design of multichannel systems. Other topics explored include the design and the performance of phase-coherent systems preceded by band-pass limiters, symbol synchronization and its effects on data detection, noncoherent communication over the Gaussian channel, and tracking loops with improved performance.

Lindsey, W. C.↗

Wind Profiling from a New Compact, Pulsed, 2-Micron, Coherent-Detection Doppler Lidar Transceiver during Wind Measurement Intercomparison

NASA Langley Research Center has a long history of developing 2-micron laser transmitter for wind sensing. With support from NASA Laser Risk Reduction Program (LRRP) and Instrument Incubator Program (IIP), NASA Langley Research Center has developed a state-of-the-art compact lidar transceiver for a pulsed coherent Doppler lidar system for wind measurement. This lidar system was recently deployed at Howard University facility in Beltsville, Maryland, along with other wind lidar systems. Coherent Doppler wind lidar ground-based wind measurements and comparisons with other lidars and other sensors will be presented.

Singh, Upendra N.↗

Infrared lidars for atmospheric remote sensing

Lidars using pulsed TEA-CO2 transmitters and coherent receivers have been developed at JPL and used to measure atmospheric backscatter and extinction at wavelengths in the 9-11 micron region. The global winds measurement application of coherent Doppler lidar requires intensive study of the global climatology of aerosol and cloud backscatter and extinction. An airborne lidar was recently flown on the NASA DC-8 research aircraft for operation during two Pacific circumnavigation missions. The instrument characteristics, as well as representative measurement results, are discussed.

Menzies, Robert T.↗

Coherent lidar signal fluctuation reduction by means of frequency diversity technique

The atmospheric return measured by a coherent lidar is typically characterized by rapid and deep fluctuations in signal strength. These fluctuations result from the interference of the fields backscattered to the lidar from randomly located aerosol particles which move relative to the lidar pulse. In many applications, it is necessary to determine the average value of the lidar signal intensity at some range. A new method utilizes frequency diversity initially suggested by Goldstein and subsequently studied in the microwave radar domain by others. It is expected that the application of the frequency diversity method in the coherent lidar domain will eventually provide greater efficiency and speed in the return signal averaging needed to obtain accurate intensity estimates. The frequency diversity method recognizes that the transmitted lidar pulse is very long compared to a wavelength and consequently a given phase, theta sub i, is repeated many times within the pulse. In order to test this concept, a fairly simple laboratory experiment was designed which simulates scattering of a lidar pulse from atmospheric aerosol. The testing of the frequency diversity method is discussed.

Schotland, R. M.↗