Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Cloud Scaling Properties and Cloud Parameterization

Cloud liquid and cloud traction variability is studied as a function of horizontal scale in the ECMWF forecast model during several 10-day runs at the highest available model resolution, recently refined from approximately 60 km (T213) down to approximately 20 km (T639). At higher resolutions, model plane-parallel albedo biases are reduced, so that models may be tuned to have larger, more realistic, cloud liquid water amounts, However, the distribution of cloud liquid assumed -within- each gridbox, for radiative and thermodynamic computations, depends on ad hoc assumptions that are not necessarily consistent with observed scaling properties, or with scaling properties produced by the model at larger scales. To study the larger-scale cloud properties, ten locations on the Earth are chosen to coincide with locations having considerable surface data available for validation, and representing a variety of climatic regimes, scaling exponents are determined from a range or scales down to model resolution, and are re-computed every three hours, separately for low, medium and high clouds, as well as column-integrated cloudiness. Cloud variability fluctuates in time, due to diurnal, synoptic and other' processes, but scaling exponents are found to be relatively stable. various approaches are considered for applying computed cloud scaling to subgrid cloud distributions used for radiation, beyond simple random or maximal overlap now in common use. Considerably more work is needed to compare model cloud scaling with observations. This will be aided by increased availability of high-resolution surface, aircraft and satellite data, and by the increasing resolution of global models,

Cahalan, R. F.↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

Lidar Measurements of Stratospheric Ozone, Aerosols and Temperature during the SAUNA Campaign at Sodankyla, Finland

The Sodankyla Total Column Ozone Intercomparison (SAUNA) campaign took place at the Finnish Meteorological Institute Arctic Research Center (FMI-ARC) at Sodankyla, Finland (67.37 N) in two separate phases during early spring 2006, and winter 2007. These campaigns has several goals: to determine and improve the accuracy of total column ozone measurements during periods of low solar zenith angle and high total column ozone; to determine the effect of ozone profile shape on the total column retrieval; and to make validate satellite ozone measurements under these same conditions. The GSFC Stratospheric Ozone Lidar (STROZ), which makes profile measurements of ozone temperature, aerosols and water vapor participated in both phases of the campaign. During the deployments, more than 30 profile measurements were made by the lidar instrument, along with Dobson, Brewer, DOAS, ozonesonde, and satellite measurements. The presentation will concentrate on STROZ lidar results from the second phase of the campaign and comparisons with other instruments will be discussed. This will include both ground-based and satellite comparisons.

McGee, T.↗

Micro-machined planar field asymmetric ion mobility spectrometer as a gas chromatographic detector

A planar high field asymmetric waveform ion mobility spectrometer (PFAIMS) with a micro-machined drift tube was characterized as a detector for capillary gas chromatography. The performance of the PFAIMS was compared directly to that of a flame ionization detector (FID) for the separation of a ketone mixture from butanone to decanone. Effluent from the column was continuously sampled by the detector and mobility scans could be obtained throughout the chromatographic analysis providing chemical inforrmation in mobility scans orthogonal to retention time. Limits of detection were approximately I ng for measurement of positive ions and were comparable or slightly better than those for the FID. Direct comparison of calibration curves for the FAIMS and the FID was possible over four orders of magnitude with a semi-log plot. The concentration dependence of the PFAIMS mobility scans showed the dependence between ion intensity and ion clustering, evident in other mobility spectrometers and atmospheric pressure ionization technologies. Ions were identified using mass spectrometry as the protonated monomer and the proton bound dimer of the ketones. Residence time for column effluent in the PFAIMS was calculated as approximately 1 ms and a 36% increase in extra-column broadening versus the FID occurred with the PFAIMS.

NASA Discipline Life Sciences Technologies↗

The Broad-Band X-Ray Spectrum of IC 4329A from a Joint NuSTAR/Suzaku Observation

We have obtained a deep, simultaneous observation of the bright, nearby Seyfert galaxy IC 4329A with Suzaku and NuSTAR (Nuclear Spectroscopic Telescope Array). Through a detailed spectral analysis, we are able to robustly separate the continuum, absorption, and distant reflection components in the spectrum. The absorbing column is found to be modest (approximately 6 times 10 (sup 21) per square centimeter), and does not introduce any significant curvature in the Fe K band. We are able to place a strong constraint on the presence of a broadened Fe K alpha line (E (sub rest) equals 6.46 (from plus 0.08 to minus 0.07) kiloelectronvolts with sigma equals 0.33 (from plus 0.08 to minus 0.07) kiloelectronvolts and EW equals 34 (from plus 8 to minus 7) electronvolts), though we are not able to constrain any of the parameters of a relativistic reflection model. These results highlight the range in broad Fe K line strengths observed in nearby, bright, active galactic nuclei (roughly an order of magnitude), and imply a corresponding range in the physical properties of the inner accretion disk in these sources. We have also updated our previously reported measurement of the high-energy cutoff of the hard X-ray emission using both observatories rather than just NuSTAR alone: E (sub cut) equals 186 plus or minus 14 kiloelectronvolts. This high-energy cutoff acts as a proxy for the temperature of the coronal electron plasma, enabling us to further separate this parameter from the plasmas optical depth and to update our results for these parameters as well. We derive kT 50 (from plus 6 to minus 3) kiloelectronvolts with tau equals 2.34 (from plus +0.16 to minus 0.11) using a spherical geometry, kT equals 61 plus or minus1 kiloelectronvolt with tau equals 0.68 plus or minus 0.02 for a slab geometry, with both having an equivalent goodness-of-fit.

Dynamics - stars↗

Microgravity electrophoresis: A study of the factors that affect free-fluid separation

Electrophoresis experiments have been performed in the microgravity environment of the Space Shuttle. Test particles (fixed human and rabbit erythrocytes) migrated as expected in a static column and test macromolecules (human serum albumin, ovalbumin, hemoglobin A, and Pneumococcus polysaccharide 6B) migrated as expected in a continuous flow apparatus. The concentrations studied exceeded those that can be used in free-fluid separation and purification processes at unit gravity.

Source record↗

Laboratory and field observations of the growth of columnar and plate crystals from frozen droplets

A laboratory experiment was initiated to grow the banded columnar crystals found in cirrus clouds and to determine if they nucleated through a freezing nucleus. Banded columnar crystals were collected in cirrus clouds and also grown in a laboratory cold box over a temperature range of -20 to -46C. They were observed to grow from a frozen droplet through several distinct crystalline transitions. The first distinct crystalline form observed following the growth of a frozen droplet was a polyhedral crystal. With further growth, the polyhedral crystal developed end plates, and it appeared to be a 'double plate.' Then the separation between the plates nearly filled in to leave the characteristic band. Certain columns (-6 to -10C) and plates (-10 to -20C) were also observed to grow from a frozen droplet and showed similar crystalline transitions.

Heymsfield, A. J.↗

Isoelectric focusing of proteins and peptides

Egg-white solution was chosen as the reference solution in order to assess the effects of operational parameters (voltage, flow rate, ampholine pH range and concentration, and protein concentration) of the RIEF apparatus on protein resolution. Topics of discussion include: (1) comparison of RIEF apparatus to conventional IEF techniques (column and PAG) with respect to resolution and throughput; (2) peptide and protein separation (AHF, Thymosin - Fraction 5, vasoactive peptide, L-asparaginase and ACP); and (3) detection of peptides - dansyl derivatives of amino acids and peptides, post-focusing fluorescent labeling of amino acids, peptides and proteins, and ampholine extraction from focused gels.

Egen, N.↗

Radiography in High Mass X-Ray Binaries: Micro-Structure of the Stellar Wind Through Variability of the Column Density

Context. In high mass X-ray binaries, an accreting compact object orbits a high mass star, which loses mass through a dense and in homogeneous wind. Aims. Using the compact object as an X-ray backlight, the time variability of the absorbing column density in the wind can be exploited in order to shed light on the micro-structure of the wind and obtain unbiased stellar mass-loss rates for high mass stars. Methods. We developed a simplified representation of the stellar wind where all the matter is gathered in spherical “clumps” that are radially advected away from the star. This model enables us to explore the connections between the stochastic properties of the wind and the variability of the column density for a comprehensive set of parameters related to the orbit and to the wind micro-structure, such as the size of the clumps and their individual mass. In particular, we focus on the evolution with the orbital phase of the standard deviation of the column density and of the characteristic duration of enhanced absorption episodes. Using the porosity length, we derive analytical predictions and compare them to the standard deviations and coherence time scales that were obtained. Results. We identified the favorable systems and orbital phases to determine the wind micro-structure. The coherence time scale of the column density is shown to be the self-crossing time of a single clump in front of the compact object. We thus provide a procedure to get accurate measurements of the size and of the mass of the clumps, purely based on the observable time variability of the column density. Conclusions. The coherence time scale grants direct access to the size of the clumps, while their mass can be deduced separately from the amplitude of the variability. We further show how monitoring the variability at superior conjunctions can probe the onset of the clump-forming region above the stellar photosphere. If the high column density variations in some high mass X-ray binaries are due to unaccreted clumps which are passing by the line-of-sight, this would require high mass clumps to reproduce the observed peak-to-peak amplitude and coherence time scales. These clump properties are marginally compatible with the ones derived from radiative-hydrodynamics simulations. Alternatively, the following components could contribute to the variability of the column density: larger orbital scale structures produced by a mechanism that has yet to be identified or a dense environment in the immediate vicinity of the accretor, such as an accretion disk, an outflow, or a spherical shell surrounding the magnetosphere of the accreting neutron star.

stars: mass loss↗

Sunspots and the physics of magnetic flux tubes. IX - Umbral dots and longitudinal overstability

The dynamical properties of the sunspot field and of a column of hot gas confined by such a vertical magnetic field are examined in order to understand the umbral dot within the context of the magnetic sunspot structure. Attention is given to the conditions necessary for gas intrusion, longitudinal as well as convective overstability, the growing modes, and the even mode. With the hypothesis that the subsurface magnetic field of a sunspot splits into many separate flux tubes with field-free gas between, it is suggested that the field-free columns occasionally punch their way up through the overlying magnetic field to the surface, appearing there as the bright, field-free umbral dots. Effects fostering the phenomenon are also discussed, that is, the enhanced temperature of a column of rising gas, the strongly reduced overhead magnetic pressure, and the initiated upward intrusion; these effects are illustrated with examples.

Parker, E. N.↗

A method of isolating organic compounds present in water

Water sample is passed through a column containing macroreticular resin, which absorbs only nonionic organic compounds. These compounds are selectively separated using aqueous eluents of varying pH, or completely exuded with small amount of an organic eluent.

Calder, G. V.↗

Analysis of a spacecraft instrument ball bearing assembly lubricated by a perfluoroalkylether

An analysis of a spacecraft instrument ball bearing assembly, subjected to a scanning life test, was performed to determine the possible case of rotational problems involving these units aboard several satellites. The analysis indicated an ineffective transfer of a fluorinated liquid lubricant from a phenolic retainer to the bearing balls. Part of the analysis led to a novel HPLC separation method employing a fluorinated mobile phase in conjunction with silica based size exclusion columns.

Morales, W.↗

Multiplex gas chromatography for use in space craft

Gas chromatography is a powerful technique for the analysis of gaseous mixtures. Some limitations in this technique still exist which can be alleviated with multiplex gas chromatography (MGC). In MGC, rapid multiple sample injections are made into the column without having to wait for one determination to be finished before taking a new sample. The resulting data must then be reduced using computational methods such as cross correlation. In order to efficiently perform multiplexgas chromatography, experiments in the laboratory and on board future space craft, skills, equipment, and computer software were developed. Three new techniques for modulating, i.e., changing, sample concentrations were demonstrated by using desorption, decomposition, and catalytic modulators. In all of them, the need for a separate gas stream as the carrier was avoided by placing the modulator at the head of the column to directly modulate a sample stream. Finally, the analysis of an environmental sample by multiplex chromatography was accomplished by employing silver oxide to catalytically modulate methane in ambient air.

Valentin, J. R.↗

Investigation of porous polymer gas chromatographic packings for atmospheric analysis of extraterrestrial bodies

Measurement of the permanent gases in the atmospheres of mission targets is a major objective. A 16 meter long Porapak N column was used on the Venus probe and required a rather high carrier gas flow rate. The researchers have, therefore, surveyed commercial porous polymer types which had some ability to resolve nitrogen, oxygen, argon and carbon monoxide gases. Porapaks N and Q appeared superior to most. Batch to batch variation, however, was quite wide, so the researchers learned how to synthesize porous polymer and investigated some of the factors affecting the separations. A polymer was synthesized which was superior to all commercial products and allowed at least a 50% reduction in length and flow rate of carrier gas. Similar studies were made concerning the separation of hydrocarbons and new porous polymers have been synthesized which represent significant improvements in time of analysis, column, and carrier gas flow rate.

Pollock, G. E.↗

The determination of HNO3 column amounts from tunable diode laser heterodyne spectrometer spectra taken at Jungfruajoch, Switzerland

In May of 1991 a tunable diode laser heterodyne spectrometer built by the National Physical Laboratory was operated at the International Scientific Station of the Jungfraujoch (46.5 deg N, 8.0 deg E, altitude 3.56 km). Nitric acid spectra in the region of 868 wavenumbers were recorded at sunset and sunrise on two separate days at a resolution of 0.0013 wavenumbers with a signal-to-noise ratio of approximately 130:1. A vertical column amount of HNO3 of 1.61 x 10(exp 16) molecules/sq cm was determined using an atmospheric transmission model developed at the University of Denver. The mean of a number of mid-latitude, northern hemisphere profiles was used as the initial profile for the inversion. A comparison of different initial profiles provides information on the sensitivity of the retrieved column amount of 1.61 x 10(exp 16) molecules/sq cm lies within the range of values published in the World Meteorological Organization Report no. 16 (1986), but is considerably larger than the value of (0.99 - 1.29) x 10(exp 16) reported by Rinsland et al. (1991) for June during the period 1986 to 1990.

Fogal, P. F.↗

Comparative chromatography of chloroplast pigment

Methods for isolation of low concentration pigments of the cocklebur species are described. The methods entail two step chromatography so that the different sorption properties of the various pigments in varying column parameters can be utilized. Columnar and thin layer methods are compared. Many conditions influence separability of the chloroplasts.

Grandolfo, M.↗

Coefficients of associated Legendre functions

The exact coefficients for the explicit forms of the associated Legendre functions Pm for integer values of m,n=0,1,2,...25 are presented in tabular form together with two cross-referenced listings of the zeroes for these functions rounded to five decimal places. The unfactored coefficients and the interger coefficients are presented in adjacent columns for each function. The greatest common factor and divisor have been removed and listed separately for the integer coefficients.

Peasley, Q. D.↗