Search NASA⌕ Search

SEARCH · Search NASA

Results for “computation time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Space-Dependent Wielandt Shifts for Multigroup Diffusion Eigenvalue Problems

We present a new concept—the space-dependent Wielandt shift (SDWS)—for accelerating the convergence of the power iteration (PI) scheme for multigroup diffusion k-eigenvalue problems. The SDWS improves on standard Wielandt shift (WS) techniques, which are empirical in nature and are typically effective only when the current estimate of the solution is reasonably converged. By accounting for the physics of the problem through SDWS, we are able to improve the acceleration for the initial iterates when the current estimate of the solution is not close to convergence. Numerical results from one-dimensional problems suggest that, compared to standard WS techniques, the new SDWS techniques can provide upward of a 46% reduction in the number of PIs required for convergence and a 40% reduction in the computational time required. This improvement is sensitive to several problem-dependent factors, such as the geometry and energy-dependence of the problem, the spatial discretization, and the initial guess. The reduction in computational time is also dependent on the linear solver in the PI scheme, as it is well known that WSs can significantly worsen the conditioning of the diffusion linear system. In this paper, we provide a detailed study of the impact of WSs on the performance of several iterative linear solvers. Results from our implementation of SDWS in the three-dimensional (3D) code MPACT show that SDWS can provide similar speedups for 3D multigroup diffusion eigenvalue problems. These results also show that moderate speedups can be obtained by applying SDWS to the coarse mesh finite difference (CMFD) solver in a CMFD-accelerated transport scheme. However, the benefit of doing this may be limited because all but the first few CMFD solves are relatively easy to converge, regardless of the WS used.

Nuclear Science & Technology↗

Development of a Suspension System for the Road Transportation of Cryomodule SSR1 through a Multilevel Finite Element-Multibody Approach

The on-road transportation of cryomodules (CM) is a critical phase during which the structure may be subject to relevant dynamic loading. Thus, an accurate design of Transportation Tool (TT), equipped with a proper suspension system, is mandatory. In this paper the TT design for the PIP-II proto SSR1 CM is presented. A finite element (FE) model was developed considering the main CM parts. However, the full model was not suited for the design of the suspension system because of its computational time. Thus, it was exported as a Modal Neutral File to a multibody (MB) software, where minor components were modeled as rigid bodies or lumped stiffnesses. The reduced MB model considerably shortened the computational time and it was exploited for the design of the TT, which includes helical isolators (HI) acting as a mechanical filter. A real 3D acceleration profile, acquired during the transportation of a LCLS-II CM from Fermilab to SLAC, was used to validate the TT effectiveness in reducing the vibrational loading. In addition, the results of the MB analysis were used to perform FE analysis of critical components, such as bellows.

43 PARTICLE ACCELERATORS↗

Pin-by-Pin Core Calculation with an NEM-Based Two-Level Hybrid CMFD Algorithm

In the near future, systematic pin-by-pin core calculations are expected to provide a high level of accuracy. These are being developed in pursuit of high-fidelity tools for analyzing the reactor configurations. One such tool that has recently gained significant attention is the pin-by-pin core calculation via local-global iteration using nonlinear acceleration scheme, such as the One-Node CMFD (Coarse-Mesh Finite Difference) nonlinear algorithm. The One-Node CMFD method uses two correction factors to preserve the interface current, in contrast to the one correction term employed by conventional nonlinear iterative methods such as that proposed by Kord. S. Smith. These correction factors are updated with surface flux and net current which are obtained from a high order local problem. With two correction factors, One-Node CMFD can reduce computing time of local FMFD (Fine-Mesh Finite Difference) as it nonlinearly couples the CMFD and FMFD methods in global-local iterations. Nonetheless, very small mesh size is still required and it consequently requires long computing time for high accuracy. As such, a more flexible approach is needed to address this challenge. This paper presents one such possible approach named the hCMFD (Hybrid CMFD) method. In this method, One-Node CMFD is used to solve the global problem, while Two-Node NEM (Nodal Expansion Method) CMFD replaces FMFD as the solver for the local problem. In this paper, two kinds of CMFD methods has been simultaneously implemented for a global-local nonlinear iteration in order to do pin-by-pin heterogeneous reactor calculations. The global problem is solved by a one-node CMFD which uses two correction factors, while the local fixed-source problem is solved by the conventional two-node NEM CMFD which use one correction factor on a surface. From solution of the global eigenvalue problem, incoming partial current is obtained and it is used as boundary condition of the local fixed-source problems. It has been shown that over 99% of the whole calculations can be done in parallel with the new CMFD method for 2-D problems and the algorithm can be easily parallelized by using the OpenMP parallel scheme. The hCMFD method will enable an efficient pin-by-pin reactor analysis since a very efficient parallel calculation is possible with the hCMFD method. In future works, the hCMFD method will be extended to three-dimensional reactor problem. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Graphics processing units accelerated semiclassical initial value representation molecular dynamics

This paper presents a Graphics Processing Units (GPUs) implementation of the Semiclassical Initial Value Representation (SC-IVR) propagator for vibrational molecular spectroscopy calculations. The time-averaging formulation of the SC-IVR for power spectrum calculations is employed. Details about the GPU implementation of the semiclassical code are provided. Four molecules with an increasing number of atoms are considered and the GPU-calculated vibrational frequencies perfectly match the benchmark values. The computational time scaling of two GPUs (NVIDIA Tesla C2075 and Kepler K20), respectively, versus two CPUs (Intel Core i5 and Intel Xeon E5-2687W) and the critical issues related to the GPU implementation are discussed. The resulting reduction in computational time and power consumption is significant and semiclassical GPU calculations are shown to be environment friendly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-D-206-01: Employing a Novel Consensus Optimization Strategy to Achieve Iterative Cone Beam CT Reconstruction On a Multi-GPU Platform

Purpose: While compressed sensing-based cone-beam CT (CBCT) iterative reconstruction techniques have demonstrated tremendous capability of reconstructing high-quality images from undersampled noisy data, its long computation time still hinders wide application in routine clinic. The purpose of this study is to develop a reconstruction framework that employs modern consensus optimization techniques to achieve CBCT reconstruction on a multi-GPU platform for improved computational efficiency. Methods: Total projection data were evenly distributed to multiple GPUs. Each GPU performed reconstruction using its own projection data with a conventional total variation regularization approach to ensure image quality. In addition, the solutions from GPUs were subject to a consistency constraint that they should be identical. We solved the optimization problem with all the constraints considered rigorously using an alternating direction method of multipliers (ADMM) algorithm. The reconstruction framework was implemented using OpenCL on a platform with two Nvidia GTX590 GPU cards, each with two GPUs. We studied the performance of our method and demonstrated its advantages through a simulation case with a NCAT phantom and an experimental case with a Catphan phantom. Result: Compared with the CBCT images reconstructed using conventional FDK method with full projection datasets, our proposed method achieved comparable image quality with about one third projection numbers. The computation time on the multi-GPU platform was ∼55 s and ∼ 35 s in the two cases respectively, achieving a speedup factor of ∼ 3.0 compared with single GPU reconstruction. Conclusion: We have developed a consensus ADMM-based CBCT reconstruction method which enabled performing reconstruction on a multi-GPU platform. The achieved efficiency made this method clinically attractive.

60 APPLIED LIFE SCIENCES↗

RESOLVING THE ELECTROCHEMICAL EQUATIONS OF A SOLID OXIDE FUEL CELL FOR USE IN TRANSIENT SIMULATION AND INTEGRATION INTO CYBER-PHYSICAL SYSTEMS

A major challenge with complex cyber-physical systems stems from long model computational time that creates a mismatch between the model system and the physical system. The numerical modeling of solid oxide fuel cells (SOFCs) presents particular challenges due to the highly coupled nature of the underlying equations and the multiphysics needed to fully resolve their behavior during a transient event. To this end current approaches revolve around splitting the computational efforts into resolving temperature effects and resolving electrochemical effects. Current methods employed for the transient simulation of an SOFC for implementation in the Hybrid Performance (HyPer) facility cyberphysical plant at the National Energy Technology Laboratory reveal a distinct need for accelerated results with a high degree of stability. To this aim, an investigation into the computational time for the code reveals that the underlying electrochemical algorithm takes an order of magnitude more time than its thermal counterpart and has a tendency to vary in terms of iteration time and as such a rework of the underlying system is proposed. The primary method for accelerated electrochemical algorithm solutions is to employ higher order root finding recipes for the resolution of the highly coupled electrochemical equations. This is done with the intention to reduce the overall number of subiterations necessary for resolving voltage, current density, and species concentration, properties of the fuel cell that are all directly coupled and require nested iterative approaches. The overall objective of this approach is an order of magnitude reduction in calculation time without sacrificing stability and increasing accuracy. Specific approaches involve using both bounded and unbounded techniques, such as the False Position method and the Secant method (or if applicable Newton-Raphson) respectively, the drawbacks being slower convergence for False Position and instability for the Secant or Newton-Raphson methods. Current preliminary results on simplified versions of the parent functions involved for electrochemical calculations indicate a reduction in computational steps by a factor of two for the secant method and a factor of three for Newton-Raphson. When implemented into new modified electrochemical algorithms, the results indicate a possible order of magnitude reduction in calculation time.

Arias, Jesus↗

Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer

Purpose: To compare the dosimetric performance of Acuros XB (AXB), anisotropic analytical algorithm (AAA), and x-ray voxel Monte Carlo (XVMC) in heterogeneous phantoms and lung stereotactic body radiotherapy (SBRT) plans. Methods: Water- and lung-equivalent phantoms were combined to evaluate the percentage depth dose and dose profile. The radiation treatment machine Novalis (BrainLab AG, Feldkirchen, Germany) with an x-ray beam energy of 6 MV was used to calculate the doses in the composite phantom at a source-to-surface distance of 100 cm with a gantry angle of 0°. Subsequently, the clinical lung SBRT plans for the 26 consecutive patients were transferred from the iPlan (ver. 4.1; BrainLab AG) to the Eclipse treatment planning systems (ver. 11.0.3; Varian Medical Systems, Palo Alto, CA). The doses were then recalculated with AXB and AAA while maintaining the XVMC-calculated monitor units and beam arrangement. Then the dose-volumetric data obtained using the three different radiation dose calculation algorithms were compared. Results: The results from AXB and XVMC agreed with measurements within ±3.0% for the lung-equivalent phantom with a 6 × 6 cm{sup 2} field size, whereas AAA values were higher than measurements in the heterogeneous zone and near the boundary, with the greatest difference being 4.1%. AXB and XVMC agreed well with measurements in terms of the profile shape at the boundary of the heterogeneous zone. For the lung SBRT plans, AXB yielded lower values than XVMC in terms of the maximum doses of ITV and PTV; however, the differences were within ±3.0%. In addition to the dose-volumetric data, the dose distribution analysis showed that AXB yielded dose distribution calculations that were closer to those with XVMC than did AAA. Means ± standard deviation of the computation time was 221.6 ± 53.1 s (range, 124–358 s), 66.1 ± 16.0 s (range, 42–94 s), and 6.7 ± 1.1 s (range, 5–9 s) for XVMC, AXB, and AAA, respectively. Conclusions: In the phantom evaluations, AXB and XVMC agreed better with measurements than did AAA. Calculations differed in the density-changing zones (substance boundaries) between AXB/XVMC and AAA. In the lung SBRT cases, a comparative analysis of dose-volumetric data and dose distributions with XVMC demonstrated that the AXB provided better agreement with XVMC than AAA. The computation time of AXB was faster than that of XVMC; therefore, AXB has better balance in terms of the dosimetric performance and computation speed for clinical use than XVMC.

60 APPLIED LIFE SCIENCES↗

Mesh Adaptive Search Optimization in SERPENT2 Stereolithography Geometry

SERPENT2 Monte Carlo program has the capability to model reactor cores by stereolithography (STL) geometry. In this geometry, volumes are defined by the union of triangulated surfaces. Using the STL geometry offers unique benefits, including: 1) the model can be printed on 3D printers; 2) the possibility to use directly geometrical models from Computer-Aided Design (CAD); 3) the capability to perform multi-physics simulations coupling neutronics, thermal-hydraulics, and material science computations. In this work the STL geometry has been created by the CUBIT software, which is designed for finite elements mesh generation. The materials in the STL geometry have been assigned by a simple C program using the colors of the volumes in the CUBIT model. The goal of this work is to minimize the SERPENT2 computing time using mesh adaptive search algorithms. The basic idea is to split the geometry of the core into two zones: one zone containing the fuel elements (including the moderator and the coolant) and the other containing the reflector (and the target zone of the core, if it is driven by an external neutron source). By performing this splitting, two separate meshes are used, which results in a considerable computing time saving. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Organic scintillation detector response simulation using non-analog MCNPX-PoliMi

Organic liquid scintillation detectors are valuable for the detection of special nuclear material since they are capable of detecting both neutrons and gamma rays. Scintillators can also provide energy information which is helpful in identification and characterization of the source. In order to design scintillation based measurement systems appropriate simulation tools are needed. MCNPX-PoliMi is capable of simulating scintillation detector response; however, simulations have traditionally been run in analog mode which leads to long computation times. In this paper, non-analog MCNPX-PoliMi mode which uses variance reduction techniques is applied and tested. The non-analog MCNPX-PoliMi simulation test cases use source biasing, geometry splitting and a combination of both variance reduction techniques to efficiently simulate pulse height distribution and then time-of-flight for a heavily shielded case with a {sup 252}Cf source. An improvement factor (I), is calculated for distributions in each of the three cases above to analyze the effectiveness of the non-analog MCNPX-PoliMi simulations in reducing computation time. It is found that of the three cases, the last case which uses a combination of source biasing and geometry splitting shows the most improvement in simulation run time for the same desired variance. For pulse height distributions speedup ranging from a factor 5 to 25 is observed, while for time-of-flights the speedup factors range from 3 to 10. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Poster — Thur Eve — 44: Linearization of Compartmental Models for More Robust Estimates of Regional Hemodynamic, Metabolic and Functional Parameters using DCE-CT/PET Imaging

Quantitative analysis of dynamic positron emission tomography (PET) data usually involves minimizing a cost function with nonlinear regression, wherein the choice of starting parameter values and the presence of local minima affect the bias and variability of the estimated kinetic parameters. These nonlinear methods can also require lengthy computation time, making them unsuitable for use in clinical settings. Kinetic modeling of PET aims to estimate the rate parameter k{sub 3}, which is the binding affinity of the tracer to a biological process of interest and is highly susceptible to noise inherent in PET image acquisition. We have developed linearized kinetic models for kinetic analysis of dynamic contrast enhanced computed tomography (DCE-CT)/PET imaging, including a 2-compartment model for DCE-CT and a 3-compartment model for PET. Use of kinetic parameters estimated from DCE-CT can stabilize the kinetic analysis of dynamic PET data, allowing for more robust estimation of k{sub 3}. Furthermore, these linearized models are solved with a non-negative least squares algorithm and together they provide other advantages including: 1) only one possible solution and they do not require a choice of starting parameter values, 2) parameter estimates are comparable in accuracy to those from nonlinear models, 3) significantly reduced computational time. Our simulated data show that when blood volume and permeability are estimated with DCE-CT, the bias of k{sub 3} estimation with our linearized model is 1.97 ± 38.5% for 1,000 runs with a signal-to-noise ratio of 10. In summary, we have developed a computationally efficient technique for accurate estimation of k{sub 3} from noisy dynamic PET data.

60 APPLIED LIFE SCIENCES↗

A deep learning-guided automated workflow in LipidOz for detailed characterization of fungal fatty acid unsaturation by ozonolysis

Understanding fungal lipid biology and metabolism is critical for antifungal target discovery as lipids play central roles in cellular processes. Nuances in lipid structural differences can significantly impact their functions, making it necessary to characterize lipids in detail to enable and understanding of their roles in these complex systems. In particular, lipid double bond (DB) locations are an important component of lipid structure that can only be determined using a few specialized analytical techniques. Ozone-induced dissociation mass spectrometry (OzID-MS) is one such technique that uses ozone to break lipid DBs, producing pairs of characteristic fragments that allow the determination of DB positions. In this work we apply OzID-MS and LipidOz software to analyze the complex lipids of Saccharomyces cerevisiae yeast strains transfected with different fatty acid desaturases from Histoplasma capsulatum to determine the specific unsaturated lipids produce. The automated data analysis in LipidOz made the determination of DB positions from this large dataset more practical, but manual verification for all targets was still time-consuming. The DL model reduces manual involvement in data analysis, but since it was trained using mammalian lipid extracts, the prediction accuracy on yeast-derived data was reduced. We addressed both shortcomings by retraining the DL model to act as a pre-filter to prioritize targets for automated analysis, providing confident manually verified results but requiring less computational time and manual effort. Our workflow resulted in the determination of novel DB positions and enzymatic specificity.

mass spectrometry, deep learning, Lipidomics, doub↗

A hyperbolic-equation system approach for magnetized electron fluids in quasi-neutral plasmas

A new approach using a hyperbolic-equation system (HES) is proposed to solve for the electron fluids in quasi-neutral plasmas. The HES approach avoids treatments of cross-diffusion terms which cause numerical instabilities in conventional approaches using an elliptic equation (EE). A test calculation reveals that the HES approach can robustly solve problems of strong magnetic confinement by using an upwind method. The computation time of the HES approach is compared with that of the EE approach in terms of the size of the problem and the strength of magnetic confinement. The results indicate that the HES approach can be used to solve problems in a simple structured mesh without increasing computational time compared to the EE approach and that it features fast convergence in conditions of strong magnetic confinement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MCTP system model based on linear programming optimization of apertures obtained from sequencing patient image data maps

Purpose: The authors present a hybrid direct multileaf collimator (MLC) aperture optimization model exclusively based on sequencing of patient imaging data to be implemented on a Monte Carlo treatment planning system (MC-TPS) to allow the explicit radiation transport simulation of advanced radiotherapy treatments with optimal results in efficient times for clinical practice. Methods: The planning system (called CARMEN) is a full MC-TPS, controlled through aMATLAB interface, which is based on the sequencing of a novel map, called “biophysical” map, which is generated from enhanced image data of patients to achieve a set of segments actually deliverable. In order to reduce the required computation time, the conventional fluence map has been replaced by the biophysical map which is sequenced to provide direct apertures that will later be weighted by means of an optimization algorithm based on linear programming. A ray-casting algorithm throughout the patient CT assembles information about the found structures, the mass thickness crossed, as well as PET values. Data are recorded to generate a biophysical map for each gantry angle. These maps are the input files for a home-made sequencer developed to take into account the interactions of photons and electrons with the MLC. For each linac (Axesse of Elekta and Primus of Siemens) and energy beam studied (6, 9, 12, 15 MeV and 6 MV), phase space files were simulated with the EGSnrc/BEAMnrc code. The dose calculation in patient was carried out with the BEAMDOSE code. This code is a modified version of EGSnrc/DOSXYZnrc able to calculate the beamlet dose in order to combine them with different weights during the optimization process. Results: Three complex radiotherapy treatments were selected to check the reliability of CARMEN in situations where the MC calculation can offer an added value: A head-and-neck case (Case I) with three targets delineated on PET/CT images and a demanding dose-escalation; a partial breast irradiation case (Case II) solved with photon and electron modulated beams (IMRT + MERT); and a prostatic bed case (Case III) with a pronounced concave-shaped PTV by using volumetric modulated arc therapy. In the three cases, the required target prescription doses and constraints on organs at risk were fulfilled in a short enough time to allow routine clinical implementation. The quality assurance protocol followed to check CARMEN system showed a high agreement with the experimental measurements. Conclusions: A Monte Carlo treatment planning model exclusively based on maps performed from patient imaging data has been presented. The sequencing of these maps allows obtaining deliverable apertures which are weighted for modulation under a linear programming formulation. The model is able to solve complex radiotherapy treatments with high accuracy in an efficient computation time.

60 APPLIED LIFE SCIENCES↗

Application of the TITAN Hybrid Deterministic Transport Code to Medical Physics - Paper 118

The TITAN code is a 3-dimensional parallel deterministic transport code that solves the linear Boltzmann equation. The TITAN code has hybrid algorithms that are ideal for medical physics applications: i) SN and characteristics method and ii) SN with a fictitious quadrature set and ray-tracing. These hybrid algorithms have been used in the simulation of computed tomography (CT) and single photon emission computed tomography (SPECT) In this paper, the hybrid algorithms developed for medical physics applications in the TITAN code are discussed. First, the TITAN code's block-oriented approach for utilizing SN and characteristic solvers for CT is presented and results for a simple test case are given. Second, the paper describes a hybrid formulation for SPECT with an SN solver in the phantom, a fictitious quadrature set for directions from the phantom surface passing through the collimator, and a simplified ray-tracing algorithm for particle transport to the detector. Finally, ongoing work is described and concluding remarks are given. The TITAN code's hybrid algorithms allow it to efficiently solve problems with low-scatter regions, which are frequently found in medical physics applications. The TITAN code has been used to solve a simplified CT problem and generate projection images for SPECT simulations. The WCOS technique was developed to improve the TITAN code's collimator representation. For these applications, the TITAN code was shown to require significantly less computation time than MCNP5. Work is currently underway to implement an iterative image reconstruction algorithm in the TITAN code. A script that calls the TITAN code to complete the forward projection step in SPECT has already been used to reconstruction a 2-dimensional phantom. The ability of TITAN to fully model particle transport in the patient in short computation times is expected to be a great advantage to iterative reconstruction. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-BRA-13: Knowledge-Based Treatment Planning for Prostate LDR Brachytherapy Based On Principle Component Analysis

Purpose: To create a knowledge-based algorithm for prostate LDR brachytherapy treatment planning that standardizes plan quality using seed arrangements tailored to individual physician preferences while being fast enough for real-time planning. Methods: A dataset of 130 prior cases was compiled for a physician with an active prostate seed implant practice. Ten cases were randomly selected to test the algorithm. Contours from the 120 library cases were registered to a common reference frame. Contour variations were characterized on a point by point basis using principle component analysis (PCA). A test case was converted to PCA vectors using the same process and then compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. The seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Computational time was recorded. Any subsequent modifications were recorded that required input from a treatment planner to achieve an acceptable plan. Results: The computational time required to register contours from a test case and evaluate PCA similarity across the library was approximately 10s. Five of the ten test cases did not require any seed additions, deletions, or moves to obtain an acceptable plan. The remaining five test cases required on average 4.2 seed modifications. The time to complete manual plan modifications was less than 30s in all cases. Conclusion: A knowledge-based treatment planning algorithm was developed for prostate LDR brachytherapy based on principle component analysis. Initial results suggest that this approach can be used to quickly create treatment plans that require few if any modifications by the treatment planner. In general, test case plans have seed arrangements which are very similar to prior cases, and thus are inherently tailored to physician preferences.

60 APPLIED LIFE SCIENCES↗

Using Green's Functions to Compute 3 Dimensional Neutron Flux Maps - 16016

The knowledge of the radionuclide content of radioactive waste is of utmost importance for safety and waste management reasons. Numerical simulations are used by EDF-DP2D to anticipate dismantling and radioactive waste management. The main numerical activation schemes include the computing of a 3 dimensional neutron flux map, obtained on the basis of a neutron propagation calculation. The codes used solve the transport equation called the Boltzmann equation without simplification. The Monte Carlo method is used to solve the Boltzmann equation. Random series of numbers are used to simulate the lives of millions of neutrons. The codes follow each neutron individually, from its birth to its disappearance by leakage, absorption, or fission, and then the neutron flux map is calculated at the nominal power rating conditions. The main drawback of the Monte Carlo codes is the large computing time needed to converge within acceptable statistical criteria. This extended time period is incompatible with the multiple fuel managements used by EDF to operate its NPPs because it is necessary to make a Monte Carlo calculation for each fuel loading pattern. The solution developed by EDF-DP2D is to use the importance factors of Green's Functions to simplify the computing of the 3 dimensional neutron flux maps. Physicists talk about Green's Functions where mathematicians talk about elementary solutions of linear equations with constant coefficients. With an activation scheme based on the Green's Functions approach the 3D neutron flux is obtained on the basis of the convolution of the normalized source contributions (i.e. normalized response matrices) with the neutrons emitted by the fuel assemblies. The response matrices to unitary sources are computed with the Monte Carlo code MCNP for different tallies of interest and the neutron sources emitted by the fuel are computed with a core code for different fuel loading patterns. The principal interest of this approach is the calculation of the response matrices to unitary sources that can be used for all power distributions, thus limiting the Monte Carlo computing time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of surface termination by directional elastic peak electron spectroscopy: Experiment and theory

Experimental and theoretical details concerning the directional elastic peak electron spectroscopy are presented. The application of this experimental method to the identification of a crystalline structure of surface layers is shown for Cu(111) and Ru(0001), which enables the analysis of different surface terminations associated with different sequences of atoms along the surface normal. Theoretical data are obtained by applying the multiple scattering theory and different sources of phase shifts. The quantitative analysis performed by an R-factor reveals almost the same populations of A and B terminated (0001) terraces and proves explicitly the presence of steps of atomic height on the clean Ru(0001) surface. This is not the case for the Cu(111) surface, where the terrace termination does not affect the distribution of atomic directions within the first few atomic layers. The averaging of theoretical data versus scattering volume defined by the sphere radius R{sub max} around the emitter site is discussed in view of the computation time optimization. - Highlights: • We examined the structure and surface termination of fcc and hcp monocrystals. • Crystalline structure within the first few atomic layers was determined by DEPES. • Multiple scattering formalism was used to obtain theoretical results. • Populations of terraces with different terminations were determined. • Scattering parameters are discussed in the context of computation time optimization.

36 MATERIALS SCIENCE↗

Accelerated deep self-supervised ptycho-laminography for three-dimensional nanoscale imaging of integrated circuits

Three-dimensional inspection of nanostructures such as integrated circuits is important for security and reliability assurance. Two scanning operations are required: ptychographic to recover the complex transmissivity of the specimen, and rotation of the specimen to acquire multiple projections covering the 3D spatial frequency domain. Two types of rotational scanning are possible: tomographic and laminographic. For flat, extended samples, for which the full 180° coverage is not possible, the latter is preferable because it provides better coverage of the 3D spatial frequency domain compared to limited-angle tomography. It is also because the amount of attenuation through the sample is approximately the same for all projections. However, both techniques are time consuming because of extensive acquisition and computation time. Here, we demonstrate the acceleration of ptycho-laminographic reconstruction of integrated circuits with 16 times fewer angular samples and 4.67 times faster computation by using a physics-regularized deep self-supervised learning architecture. We check the fidelity of our reconstruction against a densely sampled reconstruction that uses full scanning and no learning. As already reported elsewhere [ Opt. Express 28 , 12872 ( 2020 ) OPEXFF 1094-4087 10.1364/OE.379200 ], we observe improvement of reconstruction quality even over the densely sampled reconstruction, due to the ability of the self-supervised learning kernel to fill the missing cone.

47 OTHER INSTRUMENTATION↗