Search NASA⌕ Search

SEARCH · Search NASA

Results for “conduction cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Geothermal-integrated thermally anisotropic building envelope for energy and peak-demand reduction

Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.

Howard, Daniel [Southern Adventist University]↗

Hot, cold, or just right? An infrared biometric sensor to improve occupant comfort and reduce overcooling in buildings via closed-loop control

To improve occupant comfort and save energy in buildings, we have developed a closed-loop air conditioning (AC) sensor-controller that predicts occupant thermal sensation from the thermographic measurement of skin temperature distribution, then uses this information to reduce overcooling (cooling-energy overuse that discomforts occupants) by regulating AC output. Taking measures to protect privacy, it combines thermal-infrared (TIR) and color (visible spectrum) cameras with machine vision to measure the skin-surface temperature profile. Since the human thermoregulation system uses skin blood flow to maintain thermoneutrality, the distribution of skin temperature can be used to predict warm, neutral, and cool thermal states. We conducted a series of human-subject thermal-sensation trials in cold-to-hot environments, measuring skin temperatures and recording thermal sensation votes. We then trained random-forest classification machine-learning models (classifiers) to estimate thermal sensation from skin temperatures or skin-temperature differences. The estimated thermal sensation was input to a proportional integral (PI) control algorithm for the AC, targeting a sensation level between neutral and warm. Our sensor-controller includes a sensor assembly, server software, and client software. The server software orients the cameras and transmits images to the client software, which in turn assesses occupant skin temperature distribution, estimates occupant thermal sensation, and controls AC operation. A demonstration conducted in a conference room in an office building near Houston, TX showed that our system reduced overcooling, decreasing AC load by 42% when the room was occupied while improving occupant comfort (fraction of “comfortable” votes) by 15 percentage points.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In situ temperature profile measurements with high-energy X-rays as a probe of optical floating zone crystal growth environment

The ability of optical floating zone (OFZ) furnaces to rapidly produce large single crystals of complex emerging materials has had a transformative effect on many scientific fields that require samples of this type. However, the crystal growth process within the OFZ furnace is not well understood owing to the challenges involved in monitoring the high-temperature crystal growth process. Novel beamline-compatible optical furnaces that approximate the inhomogeneous growth environment within an OFZ furnace have been fabricated and tested in high-energy synchrotron beamlines. In this paper, it is demonstrated that temperature profiles can be effectively extracted from powder diffraction data collected on polycrystalline ceramic rods heated at their tip. Furthermore, these measured temperature profiles can be accurately reproduced using a heat-transfer model that accounts for solid-state thermal conduction, partial sample lamp power absorption, convective air cooling and radiative cooling, allowing key thermal parameters such as thermal conductivity to be extracted from experimental data.

36 MATERIALS SCIENCE↗

Safety Testing of AGR-5/6/7 Compacts 2-2-2 and 2-2-4

Compacts 2-2-2 and 2-2-4 from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s final irradiation campaign (AGR-5/6/7) were each separately subjected to a thermal soak at 1600°C for 300 h under flowing helium to simulated conditions experienced during a postulated high-temperature gas-cooled reactor (HTGR) depressurization conduction cooldown event. The safety testing of the fuel compacts’ performance under accident conditions was conducted in the Oak Ridge National Laboratory (ORNL) Core Conduction Cooldown Test Facility (CCCTF), which utilizes a stand-alone hot cell at the Irradiated Fuels Examination Laboratory (IFEL). The CCCTF heats fuel to temperatures up to 1900°C in a non-oxidizing environment while continuously monitoring the sweep gas for radioactive 85 Kr to detect release levels associated with hermetic failure of the tristructural-isotropic (TRISO) coating surrounding each fuel kernel. In addition, certain metallic radionuclides that escape the fuel compact are collected on deposition cups that are periodically exchanged with a new cup to obtain information on the overall retention behavior of the TRISO coating layers. Because cesium can diffuse through intact pyrocarbon layers, abnormal degradation of the silicon carbide (SiC) layer in the absence of holistic TRISO coating failure is indicated by release of 134 Cs at levels equivalent to an individual particle inventory in the absence of significant 85 Kr release (Hunn et al. 2014). Additional description of the CCCTF system is provided in Appendix A.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Examining Graphite Degradation in Molten Salt Environments: A Chemical, Physical, and Material Analysis

Molten-salt reactors (MSRs) are Generation IV nuclear reactors that use liquid salt as a coolant and/or fuel. In several MSR designs, graphite serves as a moderator and/or reflector. However, due to limited experimental data and operational experience, our understanding of graphite behavior in molten salt environments remains incomplete. This report aims to identify the degradation mechanisms of nuclear graphite in MSRs, detail the mechanisms of each factor, and provide an initial assessment of their impact on the structural integrity of graphite components. This assessment is based on an extensive literature review and insights from subject matter experts. Furthermore, given the limited data, a modeling strategy using existing Grizzly software is proposed for a more thorough analysis where appropriate. Additionally, it presents mitigation strategies where applicable. The report covers physical degradation mechanisms such as infiltration, erosion, and abrasion, as well as chemical degradation mechanisms including fluorination, intercalation, corrosion, and oxidation. Molten salt can infiltrate the porous structure of graphite, leading to several detrimental effects. Entrapment of fissile products within the graphite pores can cause radiation damage and could pose challenges in the handling and disposal of contaminated components. The differential thermal expansion between the infiltrated salt and graphite, along with internal stress from pressurized molten salt and volumetric heating, can compromise the structural integrity of graphite. To mitigate these effects, employing ultra-fine graphite grades and applying sealants and coatings are effective strategies. A computational model based on coupled solid mechanics and heat transfer phenomena could be used to predict the internal stresses using Grizzly software. In pebble-bed MSRs, graphite fuel pebbles can cause abrasion against reactor components due to friction and wear. The severity of wear is influenced by various factors such as temperature, environment, and the presence of lubricants. Tribological studies reveal that higher temperatures and molten salt environments, such as FLiBe, significantly reduce wear rates compared to dry conditions. Additionally, the chemical composition of the salt can further optimize graphite's tribological performance. Long-term wear effects can be modeled by incorporating surface defects into the geometry and predict stresses under thermal and radiation effects using Grizzly software. Chemical degradation of graphite in a molten salt environment can occur through fluorination and intercalation. Fluorination can occur via replacement of hydrogen or oxygen atoms, or at the active sites, but does not cause structural degradation. Intercalation, on the other hand, can lead to exfoliation, where layers of graphite separate and peel away, damaging the graphite. Protective coatings can enhance graphite's resistance to intercalation. Graphite generally exhibits good chemical stability in molten salt environments, though it can corrode under specific conditions, particularly in the presence of impurities or oxidants. Studies have shown that protective coatings, such as plasma-sprayed partially stabilized zirconia (PSZ), can effectively prevent such degradation. Corrosion behavior varies significantly with different graphite grades and coating applications, underscoring the need for detailed studies on uncoated and coated graphite to understand and mitigate corrosion mechanisms in MSRs. Research indicates that the presence of oxidants and impurities can accelerate graphite degradation in molten salts, making it essential to explore acceptable impurity limits. Oxidation is another critical degradation mechanism, leading to weight loss and structural damage due to the formation of CO and CO 2 from the reaction of carbon atoms with oxygen. This process creates new porosity and compromises graphite's integrity. While extensive research on graphite oxidation has been conducted for gas-cooled reactors, studies specific to MSRs are limited. Findings from the coal industry suggest that molten alkali metal salts can significantly accelerate graphite oxidation, a hypothesis worth exploring for fluoride salts in MSRs. Understanding oxidation behavior in MSRs is vital for developing protective measures. The analysis of post-irradiated graphite from the MSRE experiment demonstrated exceptional chemical compatibility with molten fluoride salt, suggesting that the extent of chemical attack on graphite largely depends on the salt's infiltration capability. Therefore, the use of ultra-fine grade graphite could help mitigate chemical degradation effects. Existing oxidation modeling capabilities in Grizzly, which use reaction-diffusion equations to model graphite-air interactions, could be adapted to simulate the chemical degradation effects of graphite in molten salt environments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Molecular dynamics simulation of the effect of cooling rate on the structure and properties of lithium disilicate glass

The effects of cooling rate on the structure and properties of lithium disilicate (LS2) glass are investigated using molecular dynamics (MD) computer simulations. The evolution of structural features such as pair distribution function, bond angle distribution, and Li coordination distribution are determined, and correlated with dynamic and static properties to elucidate the effects of cooling rate. The density, elastic moduli, and diffusion coefficient are found to be highly sensitive to cooling rate, whereas the Si pair distribution function and bond angle distribution are weakly affected by the cooling rate. Additionally, the changes of Si-O-Si bond angle and Li coordination number suggest the formation of Li cluster at lower cooling rates. Furthermore, by comparing results from other simulations and reported experiments, we confirm that the increase of cooling rate leads to an increase of conductivity and a decrease of density. Finally, at very high cooling rates, we find that all the atoms in LS2-glass do not relax simultaneously, but do so in two distinct configurations.

36 MATERIALS SCIENCE↗

Results of the AGR-5/6/7 UCO TRISO fuel irradiation test in the Advanced Test Reactor

AGR-5/6/7 was the last in a series of irradiation experiments sponsored by the U.S. Department of Energy in support of the development and qualification of TRISO coated particle fuel for use in a high-temperature gas-cooled reactor. This experiment was conducted to verify the performance of the reference-design TRISO-coated low-enriched UCO fuel for modular high-temperature gas-cooled reactor normal operating conditions and to explore fuel performance at temperatures substantially beyond those typical of normal operation. A total of 194 UCO fuel compacts in five capsules were irradiated in the Advanced Test Reactor for 360.9 effective full-power days, achieving final burnup ranging from 5.66% to 15.26% fissions per initial heavy metal atom and fast neutron fluence ranging from 1.62 × 10 25 to 5.55 × 10 25 n/m 2 (E > 0.18 MeV). Calculated time-averaged fuel temperatures ranged from 467 °C to 1432 °C, with a peak fuel temperature of 1536 °C. During the first five irradiation cycles (∼180 effective full-power days), 85m Kr fission gas release-rate-to-birth-rate ratios were 10 −7 –10 −6 , indicating no particle failures. Near the end of the sixth cycle, a substantial number of in-pile particle failures occurred in Capsule 1. The fission gas release from this capsule impacted the readings from the other four capsules and led to unreliable fission gas release measurements for all capsules during the last four cycles. A preliminary post-irradiation examination of Capsule 1 fuel and internal components revealed the in-pile particle failures resulted from operational issues with the capsule, not subpar performance of the fuel particles.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cooled Gas Turbine and Combined Cycle Analysis for H 2 -CH 4 Fuel Mixes (Up to 100% H 2 )

In this study, a cooled gas turbine analysis was conducted for varying levels of hydrogen (H 2 ) blends with the natural gas. The ultimate goal is to have a gas turbine design that can be used for all the fuel blends (including 100% H 2 ) without any changes to the system. The technological developments in the cooling system, gas turbine design and materials that will be required for H 2 combustion were identified and analyzed in this study to develop an advanced gas turbine design for H 2 fuels. The study includes a combined cycle performance analysis with the H 2 fuel blends using the advanced gas turbine design developed in this study. A techno-economic analysis was conducted for analyzing the impact of the H 2 fuels on the levelized cost of electricity and cost sensitivities to fuel price and capacity factor.

03 NATURAL GAS↗

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Theory-guided Design of Refractory MPEAs for High-Temperature, Harsh-Service Conditions

Focusing on novel materials for harsh-service environments (oxidation, corrosion, and load), durability, higher operational temperature, and direct impact on power-generation technology, the goal was, using a quantitative theory-guided design approach integrated with high-throughput synthesis and characterization for validation, to accelerate by 50% the development of high temperature, refractory-based multi-principal element alloys (MPEAs) materials platforms (with co-designed oxidation-resistant, self-healing coatings) that demonstrate phase-stable operation with desired properties at 10-20% higher temperatures in oxidizing environments over state-ofthe- art systems (like Ni-stainless steels, i.e., Haynes 282 – used in critical gas turbine applications, and refractory TZM, i.e., molybdenum-rich Mo99.4-Ti0.5-Zr0.08-C0.02 in wt%). Notably, refractory MPEAs may achieve higher operational temperatures with superior creep strength and offer 50-100% larger thermal conductivity (140-170 W/m-K) than Ni-based systems, potentially eliminating active cooling, reducing system weight, complexity, and cost. Achieving this goal addresses DOE material challenges in energy generation and efficiency (higher-temperature operation), reduced lifecycle energy (waste-heat recovery), and accelerating materials development in support of AMO’s Strategic Plan and QTR goals. DOE’s Advanced Manufacturing Office (AMO) goal of reducing industrial energy intensity and GHG emissions is addressed by development of coated refractory MPEAs exhibiting 20%+ higher operational temperature (direct increase of Carnot efficiency), higher melting temperatures (better phase stability), superior creep strength (better lifetime with creep rate lower by factor of 10), larger (50-100%) thermal conductivity (improved cooling without active cooling), reduced complexity (single-phase alloys), self-healing coating (reliable oxidation-resistance) and cost.

36 MATERIALS SCIENCE↗

Enhanced Hanford Low-Activity Waste Glass Property Data Development: Phase 5 and Phase 6

This report summarizes the data collected on two test matrices of low-activity waste (LAW) glass compositions intended to expand the composition-property database: Low-Activity Waste (LAW) Phase 5: Expansion of LAW Glass Composition Boundaries and LAW Phase 6: High PCT and VHT Response Glass Matrix. Both matrix glass compositions were statistically designed to expand the LAW glass composition region. The analyses performed on these glasses include chemical composition (for target compositional verification), density, viscosity, electrical conductivity, crystal fraction, container centerline cooling with crystal identification, the product consistency test (PCT) response, the vapor hydration test (VHT) response, and sulfur solubility. Because of the slightly different scope of the two matrices, not all methods were applied to both matrices. Specifically, the following measurements were taken only on the LAW Phase 5: Expansion of LAW Glass Composition Boundaries glasses: crystal fraction as a function of temperature, density (ρ), viscosity (η), and electrical conductivity (EC, e). Combined, these data contribute a significant amount, 51 glasses, to the database for high LAW loaded enhanced waste glasses. Most of these data are focused near the boundaries of acceptable PCT and VHT responses, where prediction uncertainties are most impactful.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy Impact of Radiative Cooling Paints in Warehouses Under Various United States Climates

Although radiative cooling research is widely found in the literature, no comprehensive study has yet been conducted on the impact of novel radiant cooling (>0.91 reflectance) on the energy efficiency of warehouses. Here, in this work, we develop three building models based on a Department of Energy prototype warehouse model using trnsys, representing a typical warehouse with a black roof, a typical warehouse with a white roof, and a warehouse with novel radiative cooling (RC) paint on its roof. These models are run for 15 different cities, each representative of a different ASHRAE climate zone, to better understand the impact of RC in many different climates. It was found that an RC-coated roof in a warehouse could reduce the building's annual heating, ventilation, and air conditioning (HVAC) loads by up to 14.11 kWh/m 2 of the roof area compared to a black roof, resulting in a maximum reduction in energy costs of 0.55 $\$$/m 2 or $\$$2646/year for a large 4835 m 2 warehouse. Similarly, replacing the typical white roof coating with an RC coating could reduce the warehouse's energy consumption by up to 8.17 kWh/ m 2 of roof area, thus reducing energy costs by as much as 0.29 $\$$/m 2 or $\$$1386/year for a 4835 m 2 warehouse. In addition, applying RC paint to an unconditioned warehouse could reduce the building's ASHRAE Standard 55 indoor temperature exceedance by up to 1330 h/year compared to a black roof and up to 532 h/year compared to a white roof.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost-Benefit Analysis For Indonesia Building Sector: Whole-Building Cooling Solutions

The Net Zero World (NZW) Initiative Collaborative Work Program with the Government of Indonesia (GoI) includes technical assistance and investment mobilization facilitation to accelerate deployment of energy efficiency technologies and solutions for the building sector. A February 2023 U.S.–Indonesia Joint Workshop on Decarbonizing the Building Sector yielded a NZW Indonesia Building Decarbonization Working Group (NZW IBDWG) with four sub-working groups (SWG): SWG-A National Center, SWG-B Capacity Building, SWG-C Investment and Financing, and SWG-D Pilot Projects. Technical analysis of whole-building cooling solutions for tropical climates of Indonesia was conducted by SWG-A to quantify energy savings, carbon dioxide reductions, and comfort improvements offered by 12 passive or low-energy cooling strategies: ceiling fans with and without thermostat setbacks; cool roofs; cool walls; exterior awnings; exterior shades; interior shades; insulated roofs; insulated walls; low-e windows; solar window films; and natural ventilation. Leveraging the results from SWG-A, cost-benefit analysis (CBA) was conducted by SWG-C to assess the consumer and national costs and impacts associated with these 12 cooling solutions. The evaluation involved estimating life-cycle costs (LCC), payback period (PBP), net present values (NPV), annual electricity burden change for low-income households, and reduced national annual power-sector generation demand by 2030, 2040, 2050, and 2060. This evaluation can help guide Indonesia’s Just Energy Transition Partnership (JETP) investments in policies and programs to advance research, development, deployment, and commercial adoption (RDDCA) of efficient residential building sector cooling technologies and solutions in Indonesia. Four key energy conservation measures (ECM) have been identified to reduce air-conditioning (AC) energy demand in single-family housing in Indonesia: ceiling fan with temperature setback (to 28.1 °Celcius from 25 °C); insulated walls; insulated roof; and cool roof. This study found that low-income households with AC installations in Indonesia currently face a high energy cost burden of approximately 10%. However, by implementing a ceiling fan with temperature setback, this burden could decrease to 2.5% today and further reduce to 1.3% by the year 2060. The PBP for a ceiling fan with temperature setback is one year, indicating one of the lowest LCC and best NPV. In the planned upcoming phase of CBA, a series of building cooling improvement scenarios can be further defined, incorporating more than one ECM in combination with socio-economic factors evaluated in the initial CBA phase. Additionally, the analysis of ECM effects in multifamily housing can be expanded. This broader national analysis aims to encompass a holistic and comprehensive system-level perspective, including factors such as avoided power sector infrastructure investments, domestic job creation, domestic manufacturing job creation, and gross domestic product (GDP) growth.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Physical effects on compact high-velocity clouds in the circumgalactic medium

ABSTRACT We numerically investigate the evolution of compact high-velocity clouds (CHVCs) passing through a hot, tenuous gas representing the highly ionized circumgalactic medium (CGM) by applying the adaptive-mesh refinement code flash. The model clouds start from both hydrostatic and thermal equilibrium and are in pressure balance with the CGM. Here, we present 14 models, divided into two mass categories and two metallicities each and different velocities. We allow for self-gravity and thermal conduction or not. All models experience mass diffusion, radiative cooling, and external heating leading to dissociation and ionization. Our main findings are (1) self-gravity stabilizes clouds against Rayleigh–Taylor instability, which is disrupted within 10 sound-crossing times without; (2) clouds can develop Jeans-instable regions internally even though they are initially below Jeans mass; (3) all clouds lose mass by ram pressure and Kelvin–Helmholtz instability; (4) thermal conduction substantially lowers mass-loss rates, by this, extending the clouds’ lifetimes, particularly, more than doubling the lifetime of low-mass clouds; (5) thermal conduction leads to continuous, filamentary stripping, while the removed gas is heated up quickly and mixes efficiently with the ambient CGM; (6) without thermal conduction the removed gas consists of dense, cool, clumpy fragments; (7) thermal conduction might prevent CHVCs from forming stars; and (8) clouds decelerated by means of drag from the ambient CGM form head-tail shapes and collapse after they reach velocities characteristic for intermediate-velocity clouds. Conclusively, only sophisticated modelling of CHVCs as non-homogeneous and non-isothermal clouds with thermal conduction and self-gravity explains observed morphologies and naturally leads to the suppression of star formation.

Sander, Bastian↗

Ongoing Data Platform Development for High-Temperature Gas-cooled Reactor (HTGR) Thermal-Fluid Experiments Supported by Nuclear Energy University Program (NEUP) [Presentation Slides]

There are in total 30NEUP projects focusing on the thermal-fluid experiments related with High-Temperature Gas-cooled Reactor (HTGR) from FY2009 to FY2021, producing a large amount of high-quality validation data, however, these valuable data has been scattering everywhere and not been disseminated to the community well, and final reports are available only from OSTI webpage. This could potentially be a huge waste, not only for government budget but also for the HTGR research community. To improve access to this HTGR validation data and optimize the return on the significant investment made by DOE and supported by the Advanced Reactor Technologies (ART) Gas-Cooled Reactor (GCR) program, we conducted a survey to assess completed and ongoing HTGR NEUP projects with the aim to develop a public-access data platform that can be used to retrieve code validation data and guide future NEUP investments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Avoiding pitfalls in molecular simulation of vapor sorption: Example of propane and isobutane in metal–organic frameworks for adsorption cooling applications

This study introduces recommendations for conducting molecular simulations of vapor adsorption, with an emphasis on enhancing the accuracy, reproducibility, and comparability of results. The first aspect we address is consistency in the implementation of some details of typical molecular models, including tail corrections and cutoff distances, due to their significant influence on generated data. We highlight the importance of explicitly calculating the saturation pressures at relevant temperatures using methods such as Gibbs ensemble Monte Carlo simulations and illustrate some pitfalls in extrapolating saturation pressures using this method. For grand canonical Monte Carlo (GCMC) simulations, the input fugacity is usually calculated using an equation of state, which often requires the critical parameters of the fluid. We show the importance of using critical parameters derived from the simulation with the same model to ensure internal consistency between the simulated explicit adsorbate phase and the implicit bulk phase in GCMC. We show the advantages of presenting isotherms on a relative pressure scale to facilitate easier comparison among models and with experiment. Extending these guidelines to a practical case study, we evaluate the performance of various isoreticular metal–organic frameworks (MOFs) in adsorption cooling applications. This includes examining the advantages of using propane and isobutane as working fluids and identifying MOFs with a superior performance.

36 MATERIALS SCIENCE↗

Exploring the Effects of Guide Vane on Dimpled Cooling Channel of Gas Turbine Blade

Abstract The purpose of the current study is to find out the heat transfer and pressure drop phenomena of the cooling channel with dimples and guide vane and compare the results with the no guide vane dimpled cooling channel. The first leg of the cooling channel is 490 mm, and the second leg is 460 mm. The two legs relate to the 180 deg turn region. The guide vane was inserted at the bend region of the dimpled cooling channel. The study was conducted with two different guide vanes geometry at two different orientations, i.e., U-guide vane with protrusion and depression orientation and curve-guide vane with protrusion and depression orientations both experimentally and numerically. The numerical study was performed with the large eddy simulation method. The result shows that for both stationary and rotational motion, the U-guide vane with depression experiences the highest thermal performance. The friction factor is comparatively higher for curve-guide vane with protrusion under stationary motion. However, under rotation, the curve-protrusion guide encounters the highest friction factor, which is higher compared to the no guide vane cooling channel.

Energy & Fuels↗