Search NASA⌕ Search

SEARCH · Search NASA

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Steady global surface warming from 1973 to 2022 but increased warming rate after 1990

The change in global mean surface temperature is a crucial and broadly used indicator of the evolution of climate change. Any decadal scale changes in warming rate are however obfuscated by internal variability. Here we show that the surface temperature increase through the recent La Nina influenced years (2022) is consistent with the 50-year trend of 0.18 °C/decade. We use an Earth System Model based tool to filter out modulations to the warming rate by sea-surface temperature patterns and find consistent warming rates in four major global temperature data series. However, we also find clear indications, in all observational series, of a step-up in warming rate since around 1990. CMIP6 models generally do not capture this observed combination of long-term warming rate and recent increase.

58 GEOSCIENCES↗

Use of a priori spectral information in the measurement of x-ray flux with filtered diode arrays

Filtered x-ray diode (XRD) arrays are often used to measure x-ray spectra vs. time from spectrally continuous x-ray sources such as hohlraums. A priori models of the incident x-ray spectrum enable a more accurate unfolding of the x-ray flux as compared to the standard technique of modifying a thermal Planckian with spectral peaks or dips at the response energy of each filtered XRD channel. A model x-ray spectrum consisting of a thermal Planckian, a Gaussian at higher energy, and (in some cases) a high energy background provides an excellent fit to XRD-array measurements of x-ray emission from laser heated hohlraums. If high-resolution measurements of part of the x-ray emission spectrum are available, that information can be included in the a priori model. In cases where the x-ray emission spectrum is not Planckian, candidate x-ray spectra can be allowed or excluded by fitting them to measured XRD voltages. Here, examples are presented from the filtered XRD arrays, named Dante, at the National Ignition Facility and the Laboratory for Laser Energetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Scalable Monitoring for the CMS Filter Farm Based on Elasticsearch

A flexible monitoring system has been designed for the CMS File-based Filter Farm making use of modern data mining and analytics components. All the metadata and monitoring information concerning data flow and execution of the HLT are generated locally in the form of small documents using the JSON encoding. These documents are indexed into a hierarchy of elasticsearch (es) clusters along with process and system log information. Elasticsearch is a search server based on Apache Lucene. It provides a distributed, multitenant-capable search and aggregation engine. Since es is schema-free, any new information can be added seamlessly and the unstructured information can be queried in non-predetermined ways. The leaf es clusters consist of the very same nodes that form the Filter Farm thus providing natural horizontal scaling. A separate central” es cluster is used to collect and index aggregated information. The fine-grained information, all the way to individual processes, remains available in the leaf clusters. The central es cluster provides quasi-real-time high-level monitoring information to any kind of client. Historical data can be retrieved to analyse past problems or correlate them with external information. We discuss the design and performance of this system in the context of the CMS DAQ commissioning for LHC Run 2.

Andre, J. M.↗

Not all Greater-Than-Class c (GTCC) waste streams are created equal - 15373

Greater-Than-Class C (GTCC) waste is a low level radioactive waste (LLRW) that exceeds the Class C concentration limits in Part 61.55 of Title 10 of the Code of Federal Regulations. Typically, this waste consists of irradiated metal components from reactors such as core shrouds, support plates, and core barrels, as well as filters and resins from reactor operations and decommissioning. Sealed sources used at hospitals, medical schools, research facilities, and universities can also be classified as GTCC waste. A third category, 'Other Waste', consisting of contaminated equipment, rubble, scrap metal, filters, soil, and solidified sludges may be classified as GTCC waste based on their differing radionuclides and concentration levels. The Low-Level Radioactive Waste Policy Amendments Act of 1985 requires the Federal Government to take responsibility for the disposal of GTCC waste. All GTCC waste created from U.S. Nuclear Regulatory Commission (NRC) licensed activities, under the Atomic Energy Act of 1954, as amended, must be disposed of in an NRC licensed facility that has been determined to be adequate to protect public health and safety. Information from Argonne National Laboratory's supplemental report on GTCC waste from 2010 anticipates that the total volume of GTCC waste will be approximately 8,800 m{sup 3} (311,000 ft{sup 3}) and the projected activity of that waste will be 5.92 x 10{sup 6} TBq (160 MCi) with generation activities ending in 2083. Currently, there is no pathway for the disposal of GTCC waste in the United States. A performance-based approach may be used to subdivide GTCC waste into various waste streams by reviewing the characteristics of GTCC waste with its associated hazards. Characteristics of GTCC waste include half-life and concentration. In creating the 10 CFR Part 61 waste classification tables, which define GTCC concentrations, a number of assumptions were made regarding waste inventory and exposure scenarios for the inadvertent intruder for a generic LLRW disposal facility. The findings from other exposure scenarios (e.g., construction, agriculture, well drilling), together with the findings from evaluations of radiological characteristics of GTCC, could be used as part of a performance-based approach for categorizing GTCC waste. The findings may determine that some GTCC waste streams will be closer in characteristics to Class C waste, while other GTCC waste streams will have characteristics similar to high-level waste and may require a higher degree of isolation from the public. The application of a site-specific and performance-based approach to GTCC waste stream characterization could assist the NRC in developing specific technical requirements for future disposal of various types of GTCC waste. Examples of part of a performance-based approach that examine and evaluate the radiological characteristics of GTCC waste will be presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of plasma parameters with magnetic filter field and pressure to maximize H{sup −} ion density in a negative hydrogen ion source

Transverse magnetic filter field as well as operating pressure is considered to be an important control knob to enhance negative hydrogen ion production via plasma parameter optimization in volume-produced negative hydrogen ion sources. Stronger filter field to reduce electron temperature sufficiently in the extraction region is favorable, but generally known to be limited by electron density drop near the extraction region. In this study, unexpected electron density increase instead of density drop is observed in front of the extraction region when the applied transverse filter field increases monotonically toward the extraction aperture. Measurements of plasma parameters with a movable Langmuir probe indicate that the increased electron density may be caused by low energy electron accumulation in the filter region decreasing perpendicular diffusion coefficients across the increasing filter field. Negative hydrogen ion populations are estimated from the measured profiles of electron temperatures and densities and confirmed to be consistent with laser photo-detachment measurements of the H{sup −} populations for various filter field strengths and pressures. Enhanced H{sup −} population near the extraction region due to the increased low energy electrons in the filter region may be utilized to increase negative hydrogen beam currents by moving the extraction position accordingly. This new finding can be used to design efficient H{sup −} sources with an optimal filtering system by maximizing high energy electron filtering while keeping low energy electrons available in the extraction region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Making Phase-Picking Neural Networks More Consistent and Interpretable

Improving the interpretability of phase-picking neural networks remains an important task to facilitate their deployment to routine, real-time seismic monitoring. The popular phase-picking neural networks published in the literature lack interpretability because their output prediction scores do not necessarily correspond with the reliability of phase picks and can even be highly inconsistent depending on how we window the waveform data. Here, we show that systematically shifting the waveforms during training and using an antialiasing filter within the neural network architecture can substantially improve the consistency of the output prediction scores and can even make them scale with the signal-to-noise ratios of the waveforms. We demonstrate the improvements by applying these approaches to a commonly used phase-picking neural network architecture and using waveform data from the 2019 Ridgecrest earthquake sequence.

58 GEOSCIENCES↗

Trace explosive residue detection of HMX and RDX in post-detonation dust from an open-air environment

Explosives are often used in industry, geology, mining, and other applications, but it is not always clear what remains after a detonation or the fate and transport of any residual material. The goal of this study was to determine to what extent intact molecules of high explosive (HE) compounds are detectable and quantifiable from post-detonation dust and particulates in a field experiment with varied topography. We focused on HMX (1,3,5,7-Tetranitro-1,3,5,7-tetrazocane), which is less studied in field detonation literature, as the primary explosive material and RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) as the secondary material. The experiment was conducted at Site 300, Lawrence Livermore National Laboratory’s Experimental Test Site, in California, USA. Two 20.4 kg and one 40.8 kg above ground explosions (primarily comprised of LX-14, an HMX-based polymer-bonded high explosive) were detonated on an open-air firing area on separate days. The complex terrain of the firing area (e.g., buildings, berm, low-height obstacles) was advantageous to study HE deposition in relation to plume dynamics. Three types of samples were collected up to 100 m away from each shot: surface swipes of aluminum plates, surface swipes of fixed objects, and filters from air samples. We used atmospheric flow tube-mass spectrometry (AFT-MS) to quantify picogram levels of molecular residue of HE material in the post-detonation dust. An aliquot of sample extract in methanol (e.g., 1 µL of 0.5 mL) was placed onto a resistive material and then thermally desorbed into the AFT-MS. We successfully detected and quantified both HMX and RDX in many of the samples. Based on mass (pg) detected and solution dilution, we back-calculated the mass collected on the swipe or filter (ng per sample). The aerial distribution of molecular residue was consistent with the path of the plume, which was strongly determined by wind speed and direction at the time of each shot. The quantity of material detected appeared to correlate more with distance from the shot and the wind conditions than with shot size. This study demonstrates that the picogram detection levels of AFT-MS are well-suited for quantification of analytes (e.g., HMX and RDX) in environmental samples.

atmospheric flow tube-mass spectrometry (AFT-MS), ↗

Enzymatic Filter for Improved Separation of Output Signals in Enzyme Logic Systems towards 'Sense and Treat' Medicine

The major challenge for application of autonomous medical sensing systems is the noise produced by non-zero physiological concentrations of the sensed target. If the level of noise is high, then a real signal indicating abnormal changes in the physiological levels of the analytes might be hindered. Inevitably, this could lead to wrong diagnostics and treatment, and would have a negative impact on human health. Here, we report the realization of a filter system implemented to improve both the fidelity of sensing and accuracy of consequent drug release. A new filtering method was tested in the sensing system for the diagnosis of liver injury. This sensing system used the enzymes alanine transaminase (ALT) and aspartate transaminase (AST) as the inputs. Furthermore, the output of the sensing system was designed to trigger drug release, and therefore, the role of the filter in drug release was also investigated. The drug release system consists of beads with an iron - cross-linked alginate core coated with different numbers of layers of poly-L-lysine. Dissolution of the beads by the output signals of the sensing system in the presence and absence of the filter was monitored by release of encapsulated in the beads rhodamine - 6G dye mimicking release of a real drug. The obtained results offer a new view on the problem of noise reduction for systems intended to be part of sense and treat medical devices.

Mailloux, Shay↗

High-performance double-filter soft x-ray diagnostic for measurement of electron temperature structure and dynamics

A new soft x-ray (SXR) T{sub e} and tomography diagnostic has been developed for MST that can be used for simultaneous SXR spectrum measurement, tomographically reconstructed emissivity, and reconstructed and line-of-sight electron temperature. The diagnostic utilizes high-performance differential transimpedance amplifiers (gain 10{sup 5}-10{sup 9}) to provide fast time response (up to 125 kHz), allowing for the study of plasma structure dynamics. SXR double-foil T{sub e} measurements are consistent with Thomson scattering. SXR brightness through a variety of filter thicknesses has been combined with charge exchange recombination spectroscopy (CHERS) impurity density measurements to determine the plasma energy spectrum. Magnetic pickup from the fluctuating magnetic fields in the plasma (B(tilde sign){approx}20 gauss at 10-20 kHz) has been dramatically reduced by improving the detector and housing design, so that nanoampere diode currents are now measured without interference from the substantial fluctuating magnetic field incident on the plasma facing surface of the probe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of Argon ion irradiation on the thickness and structure of ultrathin amorphous carbon films

Carbon films synthesized by plasma-enhanced chemical vapor deposition (PECVD) and filtered cathodic vacuum arc (FCVA) exhibit a layered structure consisting of a bottom (interface) and a top (surface) layer rich in sp{sup 2} atomic carbon bonding and a middle (bulk) layer of much higher sp{sup 3} content. Because of significant differences in the composition, structure, and thickness of these layers, decreasing the film thickness may negatively affect its properties. In this study, transmission electron microscopy (TEM) and electron energy loss spectroscopy (EELS) were used to examine the effect of Ar{sup +} ion irradiation on the structure and thickness of ultrathin films of hydrogenated amorphous carbon (a-C:H) and hydrogen-free amorphous carbon (a-C) deposited by PECVD and FCVA, respectively. The TEM and EELS results show that 2-min ion irradiation decreases the film thickness without markedly changing the film structure and composition, whereas 4-min ion irradiation results in significant film thinning and a moderate decrease of the sp{sup 3} content of the bulk layer. This study demonstrates that Ar{sup +} ion irradiation is an effective post-deposition process for reducing the thickness and tuning the structure of ultrathin carbon films. This capability has direct implications in the synthesis of ultrathin protective carbon overcoats for extremely high-density magnetic recording applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multi‐Species Energy‐Banded Ions in the Ionosphere During the 21 January 2005 Magnetic Storm: Low‐Altitude Edge of the Warm Plasma Cloak

During the 21–22 January 2005 magnetic storm, the FAST satellite observed warm (< few keV) ions in discrete energy bands on the dayside at ∼3,000 km altitude for more than 6.5 hr. We suggest that the ionospheric energy-banded ions represent the low-altitude edge of the warm plasma cloak observed simultaneously by magnetospheric satellites. This is a clear example of the multi-species ion energy bands (10 eV to several keV) observed during strong magnetic storms by the FAST satellite, stretching from the diffuse auroral region to the plasmapause with lifetimes up to 12 hr. The close association of these energy-banded ions with magnetic storms, their broad latitudinal extent, and the presence of multiple ion species in the same energy band, rather than at the same velocity, indicate that this is a distinct phenomenon from other types of energy-banded ions. During the 21–22 January 2005 magnetic storm, the dayside ion energy band structures, centered at 10 eV (H + ), 40 eV (H + and He + ), and 160 eV (H + , He + , and O + ), were consistent with a “time-of-flight and velocity filter” formation process acting on a near-cusp, impulsive outflow of a <200 eV multi-species ion-source population, poleward and in the same hemisphere as FAST. Understanding the sources and dynamics of warm energy-banded ions and their linkage to the warm plasma cloak is important because during superstorms these ions are transported to L values as low as L ∼ 1.2 in the dawn sector, significantly altering the energetics of the mid-latitude ionosphere.

58 GEOSCIENCES↗

Spectrometer for cluster ion beam induced luminescence

A spectrometer to detect the ultra-weak luminescence originated by the collision of cluster ions on the surfaces of solid materials was constructed. This spectrometer consists of 11 photomultipliers with band-pass interference filters that can detect the luminescence within the wavelength ranging from 300 to 700 nm and of a photomultiplier without filter. The calibration of the detection system was performed using the photons emitted from a strontium aluminate fluorescent tape and from a high temperature tungsten filament. Preliminary measurements show the ability of this spectrometer to detect the cluster ion beam induced luminescence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design of a correlation electron cyclotron emission system on J-TEXT

To study the anomalous transport, a correlation electron cyclotron emission (CECE) was planned to be developed on J-TEXT for electron temperature fluctuation measurement. The spectral decorrelation method was employed for the CECE system. It was developed based on the previous 16-channel electron cyclotron emission system. They shared the optical transmission line and mixer. The CECE part consists of 4 channels. Two fixed frequency narrow band filters were used for two channels and two yttrium iron garnet (YIG) filters for the other two channels. To meet the measuring requirement, some tests have been taken for the YIG filters. The results show good performance of the filters. Gaussian optics is used to produce a good poloidal resolution. Wavenumbers resolved by the CECE diagnostic are k{sub θ} ≤ 1.5 rad/cm and k{sub r} ≤ 12 rad/cm. Some preliminary experiment results are also presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interband cascade light-emitting diodes grown on silicon substrates using GaSb buffer layer

Interband cascade light-emitting diodes (ICLEDs) offer attractive advantages for infrared applications, which would greatly expand if high-quality growth on silicon substrates could be achieved. Here, this work describes the formation of threading dislocations in ICLEDs grown monolithically on GaSb-on-Silicon wafers. The epitaxial growth is done in two stages: the GaSb-on-Silicon buffer is grown first, followed by the ICLED growth. The buffer growth involves the nucleation of a 10-nm-thick AlSb buffer layer on the silicon surface, followed by the GaSb growth. The AlSb nucleation layer promotes the formation of 90° and 60° interfacial misfit dislocations, resulting in a highly planar morphology for subsequent GaSb growth that is almost 100% relaxed. The resulting GaSb buffer for growth of the ICLED has a threading dislocation density of ~10 7 /cm 2 after ~3 μm of growth. The fabricated LEDs showed variations in device performance, with some devices demonstrating comparable light–current–voltage curves to those for devices grown on GaSb substrates, while other devices showed somewhat reduced relative performance. Cross-sectional transmission electron microscopy observations of the inferior diodes indicated that the multiplication of threading dislocations in the active region had most likely caused the increased leakage current and lower output power. Enhanced defect filter layers on the GaSb/Si substrates should provide more consistent diode performance and a viable future growth approach for antimonide-based ICLEDs and other infrared devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nontoxic nanopore electroporation for effective intracellular delivery of biological macromolecules

We present a simple nanopore-electroporation (NanoEP) platform for delivery of nucleic acids, functional protein, and Cas9 single-guide RNA ribonucleoproteins into both adherent and suspension cells with up to 80% delivery efficiency and >95% cell viability. Low-voltage electric pulses permeabilize a small area of cell membrane as a cell comes into close contact with the nanopores. The biomolecule cargo is then electrophoretically drawn into the cells through the nanopores. In addition to high-performance delivery with low cell toxicity, the NanoEP system does not require specialized buffers, expensive materials, complicated fabrication processes, or cell manipulation; it simply consists of a generic nanopore-embedded water-filter membrane and a low-voltage square-wave generator. Ultimately, the NanoEP platform offers an effective and flexible method for universal intracellular delivery.

59 BASIC BIOLOGICAL SCIENCES↗

The CMS High Level Trigger System: Experience and future development

The CMS experiment at the LHC features a two-level trigger system. Events accepted by the first level trigger, at a maximum rate of 100 kHz, are read out by the Data Acquisition system (DAQ), and subsequently assembled in memory in a farm of computers running a software high-level trigger (HLT), which selects interesting events for offline storage and analysis at a rate of order few hundred Hz. The HLT algorithms consist of sequences of offline-style reconstruction and filtering modules, executed on a farm of 0(10000) CPU cores built from commodity hardware. Experience from the operation of the HLT system in the collider run 2010/2011 is reported. The current architecture of the CMS HLT, its integration with the CMS reconstruction framework and the CMS DAQ, are discussed in the light of future development. The possible short- and medium-term evolution of the HLT software infrastructure to support extensions of the HLT computing power, and to address remaining performance and maintenance issues, are discussed.

Bauer, G.↗

Dose reduction using a dynamic, piecewise-linear attenuator

Purpose: The authors recently proposed a dynamic, prepatient x-ray attenuator capable of producing a piecewise-linear attenuation profile customized to each patient and viewing angle. This attenuator was intended to reduce scatter-to-primary ratio (SPR), dynamic range, and dose by redistributing flux. In this work the authors tested the ability of the attenuator to reduce dose and SPR in simulations. Methods: The authors selected four clinical applications, including routine full field-of-view scans of the thorax and abdomen, and targeted reconstruction tasks for an abdominal aortic aneurysm and the pancreas. Raw data were estimated by forward projection of the image volume datasets. The dynamic attenuator was controlled to reduce dose while maintaining peak variance by solving a convex optimization problem, assuminga priori knowledge of the patient anatomy. In targeted reconstruction tasks, the noise in specific regions was given increased weighting. A system with a standard attenuator (or “bowtie filter”) was used as a reference, and used either convex optimized tube current modulation (TCM) or a standard TCM heuristic. The noise of the scan was determined analytically while the dose was estimated using Monte Carlo simulations. Scatter was also estimated using Monte Carlo simulations. The sensitivity of the dynamic attenuator to patient centering was also examined by shifting the abdomen in 2 cm intervals. Results: Compared to a reference system with optimized TCM, use of the dynamic attenuator reduced dose by about 30% in routine scans and 50% in targeted scans. Compared to the TCM heuristics which are typically used withouta priori knowledge, the dose reduction is about 50% for routine scans. The dynamic attenuator gives the ability to redistribute noise and variance and produces more uniform noise profiles than systems with a conventional bowtie filter. The SPR was also modestly reduced by 10% in the thorax and 24% in the abdomen. Imaging with the dynamic attenuator was relatively insensitive to patient centering, showing a 17% increase in peak variance for a 6 cm shift of the abdomen, instead of an 82% increase in peak variance for a fixed bowtie filter. Conclusions: A dynamic prepatient x-ray attenuator consisting of multiple wedges is capable of achieving substantial dose reductions and modest SPR reductions.

61 RADIATION PROTECTION AND DOSIMETRY↗