Search NASA⌕ Search

SEARCH · Search NASA

Results for “contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

WFIRST/AFTA coronograph contrast performance sensitivity studies: simulation versus experiment

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs sequential deformable mirrors to compensate for phase and amplitude errors. Using the optical model of an Occulting Mask Coronagraph (OMC) testbed at the Jet Propulsion Laboratory, we have investigated through modeling and simulations the sensitivity of dark hole contrast in a Hybrid Lyot Coronagraph (HLC) for several error cases, including lateral and longitudinal translation errors of two deformable mirrors, DM1 and DM2, lateral and/or longitudinal translation errors of an occulting mask and a Lyot-Stop, clocking errors of DM1 and DM2, and the mismatch errors between the testbed and the model sensitivity matrices. We also investigated the effects of a control parameter, namely the actuator regularization factor, on the control efficiency and on the final contrast floor. We found several error cases which yield contrast results comparable to that observed on the HLC testbed. We present our findings in this paper.

Nemati, Bijan↗

Hybrid Lyot Coronagraph for WFIRST: High Contrast Testbed Demonstration in Flight-like Low Flux Environment

In order to validate required operation of the proposed Wide-Field InfraRed Survey Telescope (WFIRST) coronagraph instrument, we have built a testbed in Jet Propulsion Laboratory (JPL), which is analogous to the baseline WFIRST coronagraph instrument architecture. Since its birth in 2016, this testbed, named as Occulting Mask Coronagraph (OMC) testbed, has demonstrated several crucial technological milestones: Broadband high contrast demonstration in both Hybrid Lyot Coronagraph (HLC) and Shape Pupil Coronagraph (SPC) modes while the Low Order Wavefront Sensing and Control (LOWFS/C) subsystem senses and corrects the dynamic flight-like wavefront disturbances. In this paper, we present up-to-date progress of HLC mode demonstration in the OMC testbed. While injecting the flight-like low photon flux starlight with expected Line of Sight (LoS) and Wavefront Error (WFE) perturbation to the OMC testbed, we demonstrate generating high contrast dark hole images. We first study the expected photon flux in actual flight environment, and estimate detection noise and estimation accuracy of the complex electric field if the wavefront sensing algorithm is used based on the pair-wise difference imaging. Then, we introduce our improved scheme to mitigate this photon-starved flight-like low flux environment. As a result, we generate a dark hole that meets the WFIRST raw contrast requirements using the 2nd magnitude star light. We establish the key ideas, describe test setups, and demonstrate test results with data analysis.

Wilson, Daniel↗

Lessons for WFIRST CGI from Ground-Based High-Contrast Systems

The Coronagraph Instrument (CGI) for NASA’s Wide Field Infrared Survey Telescope (WFIRST) will constitute a dramatic step forward for high-contrast imaging, integral field spectroscopy, and polarimetry of exoplanets and circumstellar disks, aiming to improve upon the sensitivity of current ground-based direct imaging facilities by 2–3 orders of magnitude. Furthermore, CGI will serve as a pathfinder for future exo-Earth imaging and characterization missions by demonstrating wavefront control, coronagraphy, and spectral retrieval in a new contrast regime, and by validating instrument and telescope models at unprecedented levels of precision. To achieve this jump in performance, it is critical to draw on the experience of ground-based high-contrast facilities. We discuss several areas of relevant commonalities, including: wavefront control, post-processing of integral field unit data, and calibration and observing strategies.

Xuan, Wenhao↗

Laboratory Demonstration of High Contrast with the PIAACMC Coronagraph on an Obstructed and Segmented Aperture

Coronagraphs (together with starshades) are an important tool to directly image and characterize exoplanets, and enable the search for biomarkers in reflected light on potentially habitable worlds. Their performance and efficiency has steadily been improving over the past several decades, but has not yet reached performance limits. In particular, the expected exoplanet yield for missions such as the Astro2020-recommended “IR/O/UV Flagship” can still be improved by factors of at least 2-3, simply by continued improvements in coronagraph performance, before they plateau due to physics limits. One possible architecture that can enable at least a part of this improvement is the Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC). Itoffersthe advantages of high throughput, small inner working angle (IWA),and almost noloss inPSF sharpness, and natively supports obstructed and segmented apertures, which is essential to the Astro2020 “IR/O/UV Flagship”mission. Historically, key disadvantages of PIAA have been poor tolerance to stellar angular sizes and maturity, but latest designs and demonstrations have made significant strides in this respect.In this paper, we present the current status and overview of our program to mature the PIAACMC technology. We first review PIAACMC designs for LUVOIR-A and B, which resultedin improved expected yield of Exo-Earths relative tothe baselines for both mission concepts. In particular, for LUVOIR-B, the yield improves from 28 to 42due to improvedtolerance to stellar angular size in our design. The improvement in yield is marginal for LUVOIR-A, but our design enables detecting planets around smaller diameter stars (nearby K-dwarfs and/or farther FG stars). We also describe our modeling and vacuum demonstrationsfor the LUVOIR-A aperture(which is more challengingthan LUVOIR-B due to the central obstruction).The demonstration included a LUVOUR-A pupil mask, an on-axis PIAA set of 2 mirrors with central holes, a Boston Micromachines DM, a patterned CMC mask, Lyot stop, and supporting masks and optics. Demonstrations were conducted at JPL’s High Contrast Imaging Testbed (HCIT) using several characterization andwavefront control techniques (primarily standard EFC, several experimental techniques were attempted, as well as speckle nulling). So far, our results include 1.9e-8 raw contrast in 10% broadband light between 3.5 and 8 l/D; 4.1e-8 and 1.6e-9 coherent contrasts in monochromatic light between 2-4 and 4-8 l/D, respectively. We also present measurements and analysis of sensitivity to tip/tilt jitter and stellar angular size. Finally, we compare our test results to models, present an analysis of our limiting factors, and explorefuture prospectsfor improvement based on validated models.

Coronagraph↗

The Twin Decadal Survey Testbeds in the High Contrast Imaging Testbed facility at NASA’s Jet Propulsion Laboratory

Direct imaging of an Earth-like exoplanet will require future missions, such as the proposed HabEx or LUVOIR concepts, to achieve starlight suppression with planet/star contrast ratios on the order of 10−10 at angular separations <100 milliarcseconds in visible wavelengths. To facilitate the technology and algorithm development required to enable this ambitious scientific goal, NASA’s Exoplanet Exploration Program (ExEP) High Contrast Imaging Testbed (HCIT) facility at the Jet Propulsion Laboratory (JPL) recently commissioned the Decadal Survey Testbed (DST), a state-of-the-art, flexible, and extremely stable coronagraph testbed. This testbed integrates years of experience and lessons learned at HCIT and has now demonstrated contrast ratios as low as few times 10−10 in 10% bandwidth. Following the success of DST, the HCIT team has developed a companion testbed, the Decadal Survey Testbed 2 (DST2) that further implements lessons learned from DST, and will provide the HCIT with additional coronagraph testbed capacity and efficiency. Commissioning for DST2 is currently targeted for Fall 2021. Here we provide an update on the status of DST, and report on the design, performance modeling simulations, and status of integration and testing for DST2, highlighting updates to the design from the original DST.

Siegler, Nick↗

A New Integral Field Spectrograph for Broadband Coronagraph Demonstrations at the High Contrast Imaging Testbed Facility

An integral field spectrograph (IFS) camera may help fulfill the exoplanet characterization goals of a future Habitable Worlds Observatory. During the Nancy Grace Roman Space Telescope mission formulation phase, the Coronagraph Instrument Project established the laboratory performance baseline of a combined coronagraph and IFS system with the Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES; 1E-8 contrast over an 18% bandpass; 3--9 lambda/D bowtie-shaped control region). New laboratory demonstrations are needed to expand on this milestone in terms of contrast, bandpass, and field of view towards the requirements of a future mission capable of characterizing the atmospheres of Earth-like exoplanets. Here we present the design of a successor to PISCES that can observe a 20 lambda/D-diameter field of view with an instantaneous bandpass up to 30%, at a resolving power R > 70 at visible wavelengths. This instrument will interface with the existing coronagraph layout in the High Contrast Imaging Facility DST-2 vacuum chamber. The addition of a spectroscopic imaging camera at HCIT will benefit the wider coronagraph technology community by enabling other NASA-supported investigators to automatically obtain multi-wavelength measurements of speckles both inside and outside of their control region, and the instrument will support community-led demonstrations of high-order wavefront sensing and control techniques such as dark hole maintenance and linear dark field control.

coronagraph↗

X-ray Nanocomputed Tomography in Zernike Phase Contrast for Studying 3D Morphology of Li–O 2 Battery Electrode

In this work, we investigated the lithium peroxide (Li 2 O 2 ) and pore size distribution in lithium-O 2 battery electrodes at different states of charge using transmission X-ray microscopy coupled with Zernike phase contrast to carry out nano-Computed Tomography. We report that such technique enables, at the nanoscale, to distinguish light elements such as carbon and Li 2 O 2 in Li-O 2 battery cathode electrodes. We verified by wave-propagation simulation that this approach efficiently improves the contrast of images in comparison with the pure absorption. The Li 2 O 2 distribution and thickness, interphases, and pore network are visualized and quantified, which give a valuable insight into our cathode architecture. From this 3D analysis, we highlight modifications of the air-cathode morphology and the Li 2 O 2 spatial organization as well as their potential implication in terms of carbon surface passivation and pore-clogging. After the full recharge process, this technique can also reveal the spatial distribution of the residual Li 2 O 2 and other byproducts.

25 ENERGY STORAGE↗

Measurement of helicon waves with phase contrast imaging on DIII-D – A theoretical feasibility study

A DIII-D high-beta H-mode discharge, with I p = 850 kA, B t = 2.1 T n e = 4 10 19 m –3 , has been designed to validate full wave modeling of helicon waves by optimizing the expected response of the Phase Contrast Imaging diagnostic. Helicon waves have been predicted to have high current drive efficiency off-axis without facing the accessibility issues of lower-hybrid waves. To test these predictions experimentally, DIII-D has recently commissioned a high-power helicon antenna. To confidently predict the behavior of helicon waves in future devices, measurements of their fundamental properties and validation against models will be essential. Phase contrast imaging (PCI) is an absolutely calibrated internal reference interferometer able to measure density fluctuations with radial wavenumbers k R between 1.5 cm –1 and 20 cm –1 . For helicon waves 2 cm –1 < k R < 10 cm –1 is expected, allowing PCI to measure their envelope and wavenumber spectrum. This makes PCI a powerful tool for the validation of state-of-the-art models, like the AORSA full wave code. AORSA is used to compute the density perturbations measured by the PCI with 2D calculations corresponding to 11 different toroidal mode numbers combined to resolve the trajectory of the helicon wave in 3D. This is necessary because the waves travel 120 degrees toroidally from the antenna to the PCI. Here, a cold plasma finite element model (CPFEM) [4] is used to predict propagation through the scrape-off layer. The result of the CPFEM model is connected to AORSA by creating an artificial Gaussian antenna on the last closed flux surface. PCI shows best results for waves with small vertical wavenumbers k z . Modeling the helicon waves for several past DIII-D experiments shows that k z is minimized if the intersection of the helicon and the PCI laser beams occurs in the midplane. For such an optimized scenario the predicted signal level is two orders of magnitude larger than the background density fluctuations arising from broadband turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beyond Contrast Transfer: Spectral SNR as a Finite-Dose Metric for STEM Phase Retrieval

The contrast transfer function (CTF) is widely used to evaluate phase retrieval methods in scanning transmission electron microscopy (STEM), including center-of-mass imaging, parallax imaging, direct ptychography, and iterative ptychography. However, the CTF reflects only the maximum usable signal, neglecting the effects of finite electron fluence and the Poisson-limited nature of detection. As a result, it can significantly overestimate practical performance, especially in low-dose regimes. Here, we employ the spectral signal-to-noise ratio (SSNR), as a finite-dose statistical framework to evaluate the recoverable signal as a function of spatial frequency. Using numerical reconstructions of white-noise objects, we show that center-of-mass, parallax, and direct ptychography exhibit dose-independent SSNRs, with close-form analytic expressions. In contrast, iterative ptychography exhibits a surprising dose dependence: at low fluence, its SSNR converges to that of direct ptychography; at high fluence, it saturates at a value consistent with the maximum detective quantum efficiency predicted by recent quantum Fisher information bounds. The results highlight the limitations of CTF-based evaluation and motivate SSNR as a more accurate, finite-dose metric for assessing STEM phase retrieval methods.

STEM phase retrieval↗

High-speed quantitative X-ray multi-contrast imaging with deep learning based modulated pattern analysis

The advent of X-ray multi-contrast imaging methods, providing absorption, phase, and dark-field images, holds tremendous promise for complementary and non-destructive visualization of inner structures within materials and bio-samples. However, the low efficiency in measuring and analyzing X-ray modulated patterns has hindered their application in high-resolution in situ imaging. In this work, the Enhanced Scanning Pattern-based Imaging Neural Network (ESPINNet) is introduced as a powerful tool for achieving high-speed, high-resolution quantitative imaging. ESPINNet is faster than correlation-based speckle tracking methods such as XSVT and UMPA, and provides a balanced performance in terms of resolution and speed for data collection by using fewer scanning images. In comparison with our previously developed neural network, ESPINNet introduces the capability to generate dark-field images, further enhancing its versatility. By leveraging scanning patterns, ESPINNet significantly improves resolution and measurement precision. Furthermore, its adaptability to various modulation patterns, including those produced by sandpaper, coded masks, or gratings, ensures broad applicability. These features enable real-time 2D and 3D multi-contrast imaging, positioning ESPINNet as a transformative solution for applications in materials science and biomedical research, particularly for high-speed and in situ measurements.

X-ray at-wavelength metrology↗

High-speed phase contrast imaging of spray breakup of jet fuels under combusting conditions

X-ray phase contrast imaging is conducted at 90,517 Hz on a fuel spray to characterize the breakup of the bulk fuel into ligaments and individual droplets in a single-sector, swirl-stabilized combustor under reacting conditions. Phase contrast imaging is used to qualitatively assess spray breakup for two fuels: Jet-A, which represents a normal viscosity fuel, and a blend of JP-5 (64%) and farnesane (36% by volume), which represents a high-viscosity fuel, at three fuel-flow rates and two air inlet temperatures. Time-series images of the fuels show that atomization occurs much more rapidly at higher fuel pressure with thinner ligaments being rapidly shredded. The high-viscosity fuel is qualitatively observed to have markedly longer, thicker ligaments and larger droplet diameters after the primary breakup than the normal viscosity fuel. Using an image processing and droplet quantification strategy, the mean droplet velocity magnitudes were found to decrease with decreasing fuel pressure and fuel-flow rate. The increase in preheat temperature from 323 to 370 K results in an increase in the mean droplet velocity magnitude and a decrease in numerical average and Sauter mean diameter, indicating improved atomization. The high-viscosity fuel was found to have larger average droplet diameters at each condition than the normal viscosity fuel. The increased preheat is found to enhance the combustion efficiency, which is hypothesized to couple with the improved atomization due to the higher combustion temperatures. This indicates the importance of examining spray atomization and breakup under realistic combusting conditions for relevant fuels as the heat release directly couples with the atomization process.

42 ENGINEERING↗

Stereomotion speed perception is contrast dependent

The effect of contrast on the perception of stimulus speed for stereomotion and monocular lateral motion was investigated for successive matches in random-dot stimuli. The familiar 'Thompson effect'--that a reduction in contrast leads to a reduction in perceived speed--was found in similar proportions for both binocular images moving in depth, and for monocular images translating laterally. This result is consistent with the idea that the monocular motion system has a significant input to the stereomotion system, and dominates the speed percept for approaching motion.

Motion Perception/physiology↗

New imaging technology: measurement of myocardial perfusion by contrast echocardiography

Myocardial perfusion imaging has long been a goal for the non-invasive echocardiographic assessment of the heart. However, many factors at play in perfusion imaging have made this goal elusive. Harmonic imaging and triggered imaging with newer contrast agents have made myocardial perfusion imaging potentially practical in the very near future. The application of indicator dilution theory to the coronary circulation and bubble contrast agents is fraught with complexities and sources of error. Therefore, quantification of myocardial perfusion by non-invasive echocardiographic imaging requires further investigation in order to make this technique clinically viable.

NASA Program Biomedical Research and Countermeasur↗

Wavefront Amplitude Variation of TPF's High Contrast Imaging Testbed: Modeling and Experiment

Knowledge of wavefront amplitude is as important as the knowledge of phase for a coronagraphic high contrast imaging system. Efforts have been made to understand various contributions of the amplitude variation in Terrestrial Planet Finder's (TPF) High Contrast Imaging Testbed (HCIT). Modeling of HCIT with as-built mirror surfaces has shown an amplitude variation of 1.3% due to the phase-amplitude mixing for the testbed's front-end optics. Experimental measurements on the testbed have shown the amplitude variation is about 2.5% with the testbed's illumination pattern has a major contribution as the low order amplitude variation.

coronagraph↗

Electric Field Reconstruction in the Image Plane of a High-Contrast Coronagraph Using a Set of Pinholes around the Lyot Plane

In a setup similar to the self coherent camera, we have added a set of pinholes in the diffraction ring of the Lyot plane in a high-contrast stellar Lyot coronagraph. We describe a novel complex electric field reconstruction from image plane intensity measurements consisting of light in the coronagraph's dark hole interfering with light from the pinholes. The image plane field is modified by letting light through one pinhole at a time. In addition to estimation of the field at the science camera, this method allows for self-calibration of the probes by letting light through the pinholes in various permutations while blocking the main Lyot opening. We present results of estimation and calibration from the High Contrast Imaging Testbed along with a comparison to the pair-wise deformable mirror diversity based estimation technique. Tests are carried out in narrow-band light and over a composite 10% bandpass.

coronagraphs↗

Rapid Assessment of Contrast Sensitivity with Mobile Touch-screens

The availability of low-cost high-quality touch-screen displays in modern mobile devices has created opportunities for new approaches to routine visual measurements. Here we describe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. We will demonstrate a prototype for Apple Computer's iPad-iPod-iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing,

mobile devices↗

Studies of the Effects of Actuator Errors on the HCIT/PIAA Contrast Performance

The High Contrast Imaging Testbed Phase Induced Amplitude Apodization (HCIT/PIAA) coronagraph system at JPL relies on an Electric-Field Conjugation (EFC) wavefront correction algorithm to obtain the required high contrast. This algorithm works with one deformable mirror (DM) to estimate the electric-field to be controlled, and with one or multiple DM's to create a "dark-hole" in the image plane. We have investigated the effects of DM actuator errors on the efficiency of the EFC algorithm. The structural design of the optical system as well as the parameters of various optical elements used in the analysis are drawn from those of the HCIT/PIAA system that have been and will be implemented with one or two DM's. The simulation takes into account the surface errors of various optical elements. In this paper, we report our findings in the case of narrowband wavelength light.

PIAA↗

The Moving Group Targets of the Seeds High-Contrast Imaging Survey of Exoplanets and Disks: Results and Observations from the First Three Years

We present results from the first three years of observations of moving group (MG) targets in the Strategic Exploration of Exoplanets and Disks with Subaru (SEEDS) high-contrast imaging survey of exoplanets and disks using the Subaru telescope. We achieve typical contrasts of (is) approximately10(exp 5) at 1" and (is) approximately 10(exp 6) beyond 2" around 63 proposed members of nearby kinematic MGs. We review each of the kinematic associations to which our targets belong, concluding that five, beta Pictoris ((is) approximately 20 Myr), AB Doradus ((is) approximately 100 Myr), Columba ((is) approximately 30 Myr), Tucana-Horogium ((is) approximately 30 Myr), and TW Hydrae ((is) approximately 10 Myr), are sufficiently well-defined to constrain the ages of individual targets. Somewhat less than half of our targets are high-probability members of one of these MGs. For all of our targets, we combine proposed MG membership with other age indicators where available, including Ca ii HK emission, X-ray activity, and rotation period, to produce a posterior probability distribution of age. SEEDS observations discovered a substellar companion to one of our targets, kappa And, a late B star. We do not detect any other substellar companions, but do find seven new close binary systems, of which one still needs to be confirmed. A detailed analysis of the statistics of this sample, and of the companion mass constraints given our age probability distributions and exoplanet cooling models, will be presented in a forthcoming paper.

SEEDS high-contrast imaging survey of exoplanets↗