DGEN Aeropropulsion Research Turbofan (DART): Lossless Projection of Measured Engine Noise Spectra to a 1-Foot-Radius Arc

Baseline noise and aerodynamic data have been acquired for the DGEN Aeropropulsion Research Turbofan (DART) test rig. The DART is a fully-mobile engine test rig featuring a DGEN380 geared turbofan producing approximately 500 lbs. of thrust at sea level and a self-contained control room. Baseline noise data were acquired using 5 microphone arrays, varying distance, configuration, and angle to reflect the measurement locations at several other test facilities. Noise data were acquired at one array location on each test day to establish the repeatability of the measurements. The noise data from the different arrays is analyzed to show the limitations of projecting the results to a common radius when the noise sources are distributed and the measurement location is not in the geometric far-field.

Noise↗

Application of Digital Image Correlation in Wind Tunnel

Digital image correlation (DIC) is a non-contact measurement technique that has been used in various applications in multiple industries, from microscopic specimens all the way to large scale structures. This project involved using DIC to capture wing deflection under simulated wind loading at various angles of attack (AoA). A subscale model of a fixed-wing aircraft, shown in Figure 1, was used in the 14-footby 22-footsubsonicwind tunnel at the NASA Langley Research Center. The setup used two pairs of cameras mounted on the ceiling of the tunnel to view the starboard and port side wings. Aluminum framing was used to rigidly mount the cameras to beams in the ceiling. Camera setup challenges due to the confined space included obtaining even lighting and working around infrared (IR) cameras that were used to capture the flow over the wing. Remote connection was used to access data acquisition computers from computers in the control room. Eight measurement locations on each wing were made of 1-inch-diametercircular silver dry transfer decals that did not alter the air flow across the wing. These circles were speckled with a black ink pen and were used for the IR camera as well as for DIC systems. A mock setup outside the wind tunnel was used to optimize the camera setup and verify that the speckled tape provided sufficient correlation. DIC was used to track the position of seven locations as the AoA of the subscale model changed from −10 degrees to +10 degrees in 1-degree increments. The model was rotated at a fixed height about the center of the fuselage from −7 degrees to +10 degrees. The height of the model had to be lowered to achieve AoA slower than −7degrees due to geometric constraints of the cart supporting the model and the wind tunnel. The source of light was stationary relative to the model, so the exposure time had to be adjusted for different wing regions and AoA values. The three-dimensional (3D) visualization of the markings and the two-dimensional (2D) projection of these points onto the port wing at 0-degree AoA is shown in Figure 2.

Matlock Mennu↗

Upgrades at the Propulsion Systems Lab (PSL)

The Propulsion Systems Lab (PSL) does ground testing on full size air breathing engines. These engines range from those on commercial airplanes to fighter jets. At the PSL, engineers receive test requirements from customers and put together the necessary instrumentation, data systems, power requirements, electrical control valves, and engine controls. The engineers are also responsible for facility maintenance, repairs and upgrades. There are four major sections at the PSL; the Test floor, the Data room, the Control room and, the WDPF room. On the test floor are two test cells, cell #3 and cell #4. It is within these cells that the actual engine resides for ground testing. The cells, once sealed and taken up to altitude, are capable of reaching engine inlet temperatures of 1000 F to -90 F, and various atmospheric pressures. The engine, when operational, takes in air and gives out exhaust of up to 2000 F. The exhaust is led to another section of the cell where it is cooled to 150 F before finally redirected to the appropriate disposer. Temperature and pressure transducers detect the conditions within the cell and transmit them to the data room where the results are captured, processed, analyzed, and translated to a more comprehensive language. This is made possible with the aid of several programmable logic controllers (PLCs) and instrumentation and control systems. The translated data is then sent, via the LAN, to the control room where the results can be viewed on monitors by the engineers and customers. From the control room, the test cell conditions can be changed whenever desired. During tests, a lot takes place in the facility. The WDPF control system monitors and controls all facility parameters. This summer, I will assist the engineers; on an upgrade to the facility's distributed control and dynamic data system, in preparation for an engine test that will begin in September, the installation of control systems and various miscellaneous projects around the PSL.

Audu, Abdullahi M.↗

Fatigue response of perforated titanium for application in laminar flow control

The room temperature tensile and fatigue response of non-perforated and perforated titanium for laminar flow control application was investigated both experimentally and analytically. Results showed that multiple perforations did not affect the tensile response, but did reduce the fatigue life. A two dimensional finite element stress analysis was used to determine that the stress fields from adjacent perforations did not influence one another. The stress fields around the holes did not overlap one another, allowing the materials to be modeled as a plate with a center hole. Fatigue life was predicted using an equivalent MW flow size approach to relate the experimental results to microstructural features of the titanium. Predictions using flaw sizes ranging from 1 to 15 microns correlated within a factor of 2 with the experimental results by using a flow stress of 260 MPa. By using two different flow stresses in the crack closure model and correcting for plasticity, the experimental results were bounded by the predictions for high applied stresses. Further analysis of the complex geometry of the perforations and the local material chemistry is needed to further understand the fatigue behavior of the perforated titanium.

Johnson, W. Steven↗

Control of microbial contamination.

Two specific applications are discussed of microbial contamination control in planetary quarantine. Under the first concept, using the clean room to control environmental microorganisms, the objective is to reduce the microbial species and keep the numbers of microorganisms within an enclosure at a low level. The clean room concept is aimed at obtaining a product that has a controlled and reduced level of microbial contamination. Under the second concept, using the microbiological barrier to control microbial contamination of a specific product, the barrier techniques are designed to prevent the entry of any microorganisms into a sterile work area. Thus the assembly of space flight hardware within the confines of a microbiological barrier is aimed at obtaining a sterile product. In theory and practice, both approaches are shown to be applicable to the planetary quarantine program.

Mcdade, J. J.↗

CO2-O2 Interactions in Extension of Tolerance to Acute Hypoxia

Advantageous and/or detrimental influences associated with purposeful deviations from atmospheric levels of O2 and CO2 are studied. Specific goals have been directed to simulating situations of emergency or accidental exposure to hypoxic (10% O2) environments. They included establishing dynamic effects of hypoxia with and without CO2 (rate of acute adaptation), and stable-state (equilibrium) effects on blood and brain oxygenation. They also included effects on the physiological parameters of respiration and blood gas composition which underlie brain oxygenation. For 10% O2, a complete experiment consisted of three identical rest-exercise phases of 32 minutes duration. Following a five minute air control period, each inspired gas was administered over the next 27 minutes. The test gases were room air control, 10% +/- 0.1% O2 with 4% +/- 0.1% CO2, and 10% +/- 0.1% O2. A minimum of 45 minutes separated each phase. Relative to inspiration of 10% O2, brain oxygenation is enhanced by addition of 4% CO2. This is accomplished by increasing the rate at which O2 in arterial blood is supplied to the brain circulation (well above even the normoxic level), and on relative improvement in the arterial pressure of O2.

Lambertsen, C. J.↗

Torsional and biaxial (tension-torsion) fatigue damage mechanisms in Waspaloy at room temperature

Strain controlled torsional and biaxial (tension-torsion) low cycle fatigue behavior of Waspaloy was studied at room temperature as a function of heat treatment. Biaxial tests were conducted under proportional and nonproportional cyclic conditions. The deformation behavior under these different cyclic conditions was evaluated by slip trace analysis. For this, a Schmidt-type factor was defined for multiaxial loading conditions, and it was shown that when the slip deformation is predominant, nonproportional cycles are more damaging than proportional or pure axial or torsional cycles. This was attributed to the fact that under nonproportional cyclic conditions, deformation was through multiple slip, as opposed to single slip for other loading conditions, which gave rise to increased hardening. The total life for a given test condition was found to be independent of heat treatment. This was interpreted as being due to the differences in the cycles to initiation and propagation of cracks.

Jayaraman, N.↗

Solar heating and cooling system installed at RKL Controls Company, Lumberton, New Jersey

The final results of the design and operation of a computer controlled solar heated and cooled 40,000 square foot manufacturing building, sales office, and computer control center/display room are summarized. The system description, test data, major problems and resolutions, performance, operation and maintenance manual, equipment manufacturers' literature, and as-built drawings are presented. The solar system is composed of 6,000 square feet of flat plate collectors, external above ground storage subsystem, controls, absorption chiller, heat recovery, and a cooling tower.

Source record↗

Thin wire pointing method

A method is described for forming sharp tips on thin wires, in particular phosphor bronze wires of diameters such as one-thousandth inch used to contact micron size Schottky barrier diodes, which enables close control of tip shape and which avoids the use of highly toxic solutions. The method includes dipping an end of a phosphor bronze wire into a dilute solution of sulfamic acid and applying a current through the wire to electrochemically etch it. The humidity in the room is controlled to a level of less than 50%, and the voltage applied between the wire and another electrode in the solutions is a half wave rectified voltage. The current through the wire is monitored, and the process is stopped when the current falls to a predetermined low level.

Green, G.↗

Potato growth in response to relative humidity

Potato plants (Solanum tuberosum L. cvs. Russet Burbank, Norland, and Denali) were grown for 56 days in controlled-environment rooms under continuous light at 20C and 50% or 85% RH. No significant differences in total plant dry weight were measured between the humidity treatments, but plants grown under 85% RH produced higher tuber yields. Leaf areas were greater under 50% RH and leaves tended to be larger and darker green than at 85% RH.

Non-NASA Center↗

Environmental modification of yield and nutrient composition of 'Waldmann's Green' leaf lettuce

Leaf number, dry weight, and nutrient composition of Lactuca sativa L. cv. Waldmann's Green leaves were compared following 9 days of treatment in a controlled environment room under various combinations of photosynthetic photon flux (PPF:350 vs 800 micromoles m-2 s-1), atmospheric CO2 level (ambient vs 1500 micromoles mol-1), and single-strength (1X:15 mM) vs double-strength (2X:30 mM) nitrogen (N) as NO3- alone or as NH4(+) + NO3- (1:5 molar ratio). CO2 enrichment greatly enhanced leaf number under all PPF and N conditions, but increased leaf dry weight only at high PPF. Conditions favoring high photosynthesis enhanced leaf starch content 3-fold, and protein content increased as much as 64% with 2X NH4(+)+NO3-. Free sugar content was 6 to 9% of leaf dry weight for all treatment combinations, while fat was 1.5 to 3.5%. Ash content varied from 15 to 20% of leaf dry weight. Modified controlled environments can be used to enhance the nutritional content as well as the yield of crops to be used for life support in space-deployed, self-sustaining human habitats. Leaf lettuce is a useful model crop for demonstrating the potential of nutritional value added by environmental manipulation.

Non-NASA Center↗

A dynamic model for plant growth: validation study under changing temperatures

A dynamic simulation model to describe vegetative growth of plants, for which some functions and parameter values have been estimated previously by optimization search techniques and numerical experimentation based on data from constant temperature experiments, is validated under conditions of changing temperatures. To test the predictive capacity of the model, dry matter accumulation in the leaves, stems, and roots of tobacco plants (Nicotiana tabacum L.) was measured at 2- or 3-day intervals during a 5-week period when temperatures in controlled-environment rooms were programmed for changes at weekly and daily intervals and in ascending or descending sequences within a range of 14 to 34 degrees C. Simulations of dry matter accumulation and distribution were carried out using the programmed changes for experimental temperatures and compared with the measured values. The agreement between measured and predicted values was close and indicates that the temperature-dependent functional forms derived from constant-temperature experiments are adequate for modelling plant growth responses to conditions of changing temperatures with switching intervals as short as 1 day.

NASA Discipline Number 60-40↗

Portable superclean air column device Patent

Portable apparatus producing high velocity annular air column surrounding low velocity, filtered, superclean air central core for industrial clean room environmental control

Kiszko, W.↗