Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Transient flow thrust prediction for an ejector propulsion concept

A method for predicting transient thrust augmenting ejector characteristics is introduced. The analysis blends classic self-similar turbulent jet descriptions with a mixing region control volume analysis to predict transient effects in a new way. Details of the theoretical foundation, the solution algorithm, and sample calculations are given.

Drummond, Colin K.↗

Transient flow thrust prediction for an ejector propulsion concept

A method for predicting transient thrust augmenting ejector characteristics is introduced. The analysis blends classic self-similar turbulent jet descriptions with a mixing region control volume analysis to predict transient effects in a new way. Details of the theoretical foundation, the solution algorithm, and sample calculations are given.

Drummond, C.↗

Monte Carlo study of a model of diffusion-controlled reactions

The Monte Carlo method is used to perform averages over sink configurations in the present study of diffusion-controlled reactions occurring between solute particles and immobile spherical sinks. In order to determine the average steady state solute concentration profile in a locally perturbed solution for sink volume fractions phi of less than 0.3, the diffusion equation in the monopolar plus dipolar approximation of diffusive couplings between the sinks is solved numerically. The Monte Carlo method is shown to be the most accurate and efficient in the phi = 0.001-0.1 region, where a system of only 25 sinks suffices and the monopolar approximation alone is sufficiently accurate.

Beenakker, C. W. J.↗

Effect of Polymer Electrode Morphology on Performance of a Lithium/Polypyrrole Battery

A variety of conducting polymer batteries were described in the recent literature. In this work, a Li/Polypyrrole secondary battery is described. The effect of controlling the morphology of the polymer on enhancement of counterion diffusion in the polymer phase is explored. A method of preparing conducting polymers was developed which yields high surface area per unit volume of electrode material. A porous membrane is used as a template in which to electrochemically polymerize pyrrole, then the membrane is dissolved, leaving the polymer in a fibrillar form. Conventionally, the polymer is electrochemically polymerized as a dense polymer film on a smooth Pt disk electrode. Previous work has shown that when the polymer is electrochemically polymerized in fribrillar form, charge transport rates are faster and charge capacities are greater than for dense, conventionally grown films containing the same amount of polymer. The purpose is to expand previous work by further investigating the possibilities of the optimization of transport rates in polypyrrole films by controlling the morphology of the films. The utility of fibrillar polypyrrole as a cathode material in a lithium/polymer secondary battery is then assessed. The performance of the fibrillar battery is compared to the performance of an analogous battery which employed a conventionally grown polypyrrole film. The study includes a comparison of cyclic voltammetry, shape of charge/discharge curves, discharge time and voltage, cycle life, coulombic efficiencies, charge capacities, energy densities, and energy efficiencies.

Nicholson, Marjorie Anne↗

The ecology of microorganisms in a small closed system: Potential benefits and problems for space station

The inevitble presence on the space station of microorganisms associated with crew members and their environment will have the potential for both benefits and a range of problems including illness and corrosion of materials. This report reviews the literature presenting information about microorganisms pertinent to Environmental Control and Life Support (ECLS) on the space station. The perspective of the report is ecological, viewing the space station as an ecosystem in which biological relationships are affected by factors such as zero gravity and by closure of a small volume of space. Potential sites and activities of microorganisms on the space station and their environmental limits, microbial standards for the space station, monitoring and control methods, effects of space factors on microorganisms, and extraterrestrial contamination are discussed.

Rodgers, E. B.↗

Air Cargo Transportation Route Choice Analysis

Using a unique feature of air cargo transshipment data in the Northeast Asian region, this paper identifies the critical factors that determine the transshipment route choice. Taking advantage of the variations in the transport characteristics in each origin-destination airports pair, the paper uses a discrete choice model to describe the transshipping route choice decision made by an agent (i.e., freight forwarder, consolidator, and large shipper). The analysis incorporates two major factors, monetary cost (such as line-haul cost and landing fee) and time cost (i.e., aircraft turnaround time, including loading and unloading time, custom clearance time, and expected scheduled delay), along with other controls. The estimation method considers the presence of unobserved attributes, and corrects for resulting endogeneity by use of appropriate instrumental variables. Estimation results find that transshipment volumes are more sensitive to time cost, and that the reduction in aircraft turnaround time by 1 hour would be worth the increase in airport charges by more than $1000. Simulation exercises measures the impacts of alternative policy scenarios for a Korean airport, which has recently declared their intention to be a future regional hub in the Northeast Asian region. The results suggest that reducing aircraft turnaround time at the airport be an effective strategy, rather than subsidizing to reduce airport charges.

Obashi, Hiroshi↗

VEG-04 Pick-and-Eat Crop Production and Human Research on the International Space Station

Growing fresh, nutritious, palatable produce for crew consumption during spaceflight may provide health-promoting, bioavailable nutrients and enhance the astronaut dietary experience as we move toward longer-duration missions. Tending plants may also serve as a countermeasure for crew psychological stresses associated with spaceflight. However, requirements to support consistent growth of a variety of nutritious crops under spaceflight environmental conditions remain unclear. This study explores the potential to grow crops for consumption on the International Space Station (ISS) using the Veggie vegetable-production system. VEG-04A and B were two flight tests conducted in 2019 with the leafy green crop Mizuna mustard. Mizuna was grown in two Veggie chambers simultaneously, with the chambers set to different red-to-blue light formulations; one Veggie was programmed as “red-rich” and the second as “blue-rich.” Light quality is known to impact plant growth, nutrition, microbiology, and organoleptic characteristics on Earth, and the Veggie flight tests examined how these impacts might differ in microgravity. VEG-04A was a 35-day growth test with a single harvest. VEG-04B, a 58-day test with harvests at four, six, and eight weeks from the same plants, assessed sustained productivity. Challenges with the watering program occurred early during VEG-04A, and several plants failed to survive in both the flight and ground control operations. Thus, prior to VEG-04B, an extra test was conducted to tailor water timing and volumes. This test allowed a fine tuning of methods for VEG-04B, and generally plant survival was better in that experiment. At each harvest, the astronauts froze half of the edible plant tissue to return to Earth and weighed the remaining half using the ISS Mass Measurement Device (MMD). Weighed samples were then cleaned with produce-sanitizing wipes, and consenting crew members participated in organoleptic evaluation of the fresh produce. Organoleptic evaluations were conducted on the Mizuna crops grown in both light treatments, and data from these tests are compared to ground data collected at JSC. The remaining sanitized produce was available for crew consumption as desired. Frozen flight samples were returned for microbial and chemical analyses to assess food safety and nutritional quality. Microbial assessments included culturing and identifying aerobic bacteria, yeasts, and molds, and screening for specific human pathogens. Chemical nutrient analyses included assessing elements, antioxidants, and phenolics in plant tissues. Crew members involved in plant operations completed behavioral health surveys pre-flight, in-flight associated with plant growth and harvest activities, and post-flight. Surveys captured the amount of time spent on different plant-related operations, enjoyment of the different activities, engagement with Veggie, experience interacting with Veggie, and sensory stimulation associated with growing plants in Veggie.

Veggie↗

Madidrop for Passive Silver Dosing

Madidrop is a rectangular ceramic tablet originally designed to dose a 10-20-liter volume of water with silver to act as a biocide for remote communities with unreliable water sources. Silver as a biocide is a proposed method to control bacteria on the International Space Station or future Artemis missions. This would replace iodine currently used due to issues with a dual biocide system in place between Russian and US segments and the extra cost of iodine removal required before consumption. NASA has been reviewing this Madidrop technology and its potential application with a water reclamation system on orbit to dose silver after purifying the water. While there are a couple alternative methods to dosing silver on station, this method is like the existing passive dosing method used currently to dose iodine. Tests conducted characterize the manufacturer’s original intent to leave the tablet in a tank for a specified amount of time before removing and testing alternative passive flow-through methods. Passive flow testing involved two options: keeping the tablet intact or crushing the tablet into smaller particle sizes to increase the surface area while varying particle sizes. The results of these tests revealed a large amount of silver output at first that quickly reduced to a constant lower output within a reasonable dosing concentration range. The initial high concentration peaks after a couple days of quiescence and could be useful for shocking the initial tank water contents. Madidrop used as a passive particle doser could act as a stand-in replacement for iodine in future spaceflight water reclamation systems.

Ryan Ogilvie↗

Madidrop for Passive Silver Dosing

Madidrop is a rectangular ceramic tablet originally designed to dose a 10-20-liter volume of water with silver to act as a biocide for remote communities with unreliable water sources. Silver as a biocide is a proposed method to control bacteria on the International Space Station or future Artemis missions. This would replace iodine currently used due to issues with a dual biocide system in place between Russian and US segments and the extra cost of iodine removal required before consumption. NASA has been reviewing this Madidrop technology and its potential application with a water reclamation system on orbit to dose silver after purifying the water. While there are a couple alternative methods to dosing silver on station, this method is like the existing passive dosing method used currently to dose iodine. Tests conducted characterize the manufacturer’s original intent to leave the tablet in a tank for a specified amount of time before removing and testing alternative passive flow-through methods. Passive flow testing involved two options: keeping the tablet intact or crushing the tablet into smaller particle sizes to increase the surface area while varying particle sizes. The results of these tests revealed a large amount of silver output at first that quickly reduced to a constant lower output within a reasonable dosing concentration range. The initial high concentration peaks after a couple days of quiescence and could be useful for shocking the initial tank water contents. Madidrop used as a passive particle doser could act as a stand-in replacement for iodine in future spaceflight water reclamation systems.

Ryan Ogilvie↗

System identification of closed-loop cardiovascular control mechanisms: diabetic autonomic neuropathy

We applied cardiovascular system identification (CSI) to characterize closed-loop cardiovascular regulation in patients with diabetic autonomic neuropathy (DAN). The CSI method quantitatively analyzes beat-to-beat fluctuations in noninvasively measured heart rate, arterial blood pressure (ABP), and instantaneous lung volume (ILV) to characterize four physiological coupling mechanisms, two of which are autonomically mediated (the heart rate baroreflex and the coupling of respiration, measured in terms of ILV, to heart rate) and two of which are mechanically mediated (the coupling of ventricular contraction to the generation of the ABP wavelet and the coupling of respiration to ABP). We studied 37 control and 60 diabetic subjects who were classified as having minimal, moderate, or severe DAN on the basis of standard autonomic tests. The autonomically mediated couplings progressively decreased with increasing severity of DAN, whereas the mechanically mediated couplings were essentially unchanged. CSI identified differences between the minimal DAN and control groups, which were indistinguishable based on the standard autonomic tests. CSI may provide a powerful tool for assessing DAN.

Non-NASA Center↗

Grid Generation Techniques Utilizing the Volume Grid Manipulator

This paper presents grid generation techniques available in the Volume Grid Manipulation (VGM) code. The VGM code is designed to manipulate existing line, surface and volume grids to improve the quality of the data. It embodies an easy to read rich language of commands that enables such alterations as topology changes, grid adaption and smoothing. Additionally, the VGM code can be used to construct simplified straight lines, splines, and conic sections which are common curves used in the generation and manipulation of points, lines, surfaces and volumes (i.e., grid data). These simple geometric curves are essential in the construction of domain discretizations for computational fluid dynamic simulations. By comparison to previously established methods of generating these curves interactively, the VGM code provides control of slope continuity and grid point-to-point stretchings as well as quick changes in the controlling parameters. The VGM code offers the capability to couple the generation of these geometries with an extensive manipulation methodology in a scripting language. The scripting language allows parametric studies of a vehicle geometry to be efficiently performed to evaluate favorable trends in the design process. As examples of the powerful capabilities of the VGM code, a wake flow field domain will be appended to an existing X33 Venturestar volume grid; negative volumes resulting from grid expansions to enable flow field capture on a simple geometry, will be corrected; and geometrical changes to a vehicle component of the X33 Venturestar will be shown.

Alter, Stephen J.↗

Liquid rocket booster study. Volume 2, book 4, appendices 6-8: Reports of Rocketdyne, Pratt and Whitney, and TRW

For the pressure fed engines, detailed trade studies were conducted defining engine features such as thrust vector control methods, thrust chamber construction, etc. This was followed by engine design layouts and booster propulsion configuration layouts. For the pump fed engines parametric performance and weight data was generated for both O2/H2 and O2/RP-1 engines. Subsequent studies resulted in the selection of both LOX/RP-1 and O2/H2 propellants for the pump fed engines. More detailed analysis of the selected LOX/RP-1 and O2/H2 engines was conducted during the final phase of the study.

Source record↗

Three-Dimensional High-Order Spectral Volume Method for Solving Maxwell's Equations on Unstructured Grids

A three-dimensional, high-order, conservative, and efficient discontinuous spectral volume (SV) method for the solutions of Maxwell's equations on unstructured grids is presented. The concept of discontinuous 2nd high-order loca1 representations to achieve conservation and high accuracy is utilized in a manner similar to the Discontinuous Galerkin (DG) method, but instead of using a Galerkin finite-element formulation, the SV method is based on a finite-volume approach to attain a simpler formulation. Conventional unstructured finite-volume methods require data reconstruction based on the least-squares formulation using neighboring cell data. Since each unknown employs a different stencil, one must repeat the least-squares inversion for every cell at each time step, or to store the inversion coefficients. In a high-order, three-dimensional computation, the former would involve impractically large CPU time, while for the latter the memory requirement becomes prohibitive. In the SV method, one starts with a relatively coarse grid of triangles or tetrahedra, called spectral volumes (SVs), and partition each SV into a number of structured subcells, called control volumes (CVs), that support a polynomial expansion of a desired degree of precision. The unknowns are cell averages over CVs. If all the SVs are partitioned in a geometrically similar manner, the reconstruction becomes universal as a weighted sum of unknowns, and only a few universal coefficients need to be stored for the surface integrals over CV faces. Since the solution is discontinuous across the SV boundaries, a Riemann solver is thus necessary to maintain conservation. In the paper, multi-parameter and symmetric SV partitions, up to quartic for triangle and cubic for tetrahedron, are first presented. The corresponding weight coefficients for CV face integrals in terms of CV cell averages for each partition are analytically determined. These discretization formulas are then applied to the integral form of the Maxwell equations. All numerical procedures for outer boundary, material interface, zonal interface, and interior SV face are unified with a single characteristic formulation. The load balancing in a massive parallel computing environment is therefore easier to achieve. A parameter is introduced in the Riemann solver to control the strength of the smoothing term. Important aspects of the data structure and its effects to communication and the optimum use of cache memory are discussed. Results will be presented for plane TE and TM waves incident on a perfectly conducting cylinder for up to fifth order of accuracy, and a plane wave incident on a perfectly conducting sphere for up to fourth order of accuracy. Comparisons are made with exact solutions for these cases.

Liu, Yen↗

Low level CO2 effects on pulmonary function in humans

The purpose of the study was to determine whether chamber exposure to low levels of CO2 results in functional alterations in gas mixing and closing volume in humans. Four healthy volunteer subjects were exposed to 0.7% CO2 and to 1.2% CO2. Spirometry, lung volumes, single breath nitrogen washout, diffusing capacity for carbon monoxide (DLCO) by two methods, and cardiac output were measured in triplicate. Values were obtained over two non-consecutive days during the training period (control) and on days 2 or 3, 4, 6, 10, 13, and 23 of exposure to each CO2 level. Measurements were made during the same time of day. There was one day of testing after exposure, while still in the chamber but off carbon dioxide. The order of testing, up until measurements of DLCO and cardiac output, were randomized to avoid presentation effects. The consistent findings were a reduction in diffusing capacity for carbon monoxide and a fall in cardiac output, occurring to a similar degree with both exposures. For the group as a whole, there was no indication of major effects on spirometry, lung volumes, gas mixing or dead space. We conclude that small changes may occur in the function of distal gas exchanging units; however, these effects were not associated with any adverse health effects. The likelihood of pathophysiologic changes in lung function or structure with 0.7 or 1.2% CO2 exposure for this period of time, is therefore, low.

NASA Discipline Cardiopulmonary↗

A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

Wang, Zuwei↗

Liquid and gaseous oxygen safety review, volume 1

Materials used or contained in liquid and gaseous oxygen systems are analyzed for their compatibility; and areas of possible concern in oxygen systems are outlined. Design criteria, cleaning procedures, and quality control methods are covered in detail.

Lapin, A.↗

Microstructure and Properties of Thermally Sprayed Functionally Graded Coatings for Polymeric Substrates

The use of polymer matrix composites (PMCs) in the gas flow path of advanced turbine engines offers significant benefits for aircraft engine performance but their useful lifetime is limited by their poor erosion resistance. High velocity oxy-fuel (HVOF) sprayed polymer/cermet functionally graded (FGM) coatings are being investigated as a method to address this technology gap by providing erosion and oxidation protection to polymer matrix composites. The FGM coating structures are based on a polyimide matrix filled with varying volume fractions of WC-Co. The graded coating architecture was produced using a combination of internal and external feedstock injection, via two computer-controlled powder feeders and controlled substrate preheating. Porosity, coating thickness and volume fraction of the WC-Co filler retained in the coatings were determined using standard metallographic techniques and computer image analysis. The pull-off strength (often referred to as the adhesive strength) of the coatings was evaluated according to the ASTM D 4541 standard test method, which measured the greatest normal tensile force that the coating could withstand. Adhesive/cohesive strengths were determined for three different types of coating structures and compared based on the maximum indicated load and the surface area loaded. The nature and locus of the fractures were characterized according to the percent of adhesive and/or cohesive failure, and the tested interfaces and layers involved were analyzed by Scanning Electron Microscopy.

Ivosevic, M.↗