Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Unsupervised multimodal fusion of in-process sensor data for advanced manufacturing process monitoring

Effective monitoring of manufacturing processes is crucial for maintaining product quality and operational efficiency. Modern manufacturing environments often generate vast amounts of complementary multimodal data, including visual imagery from various perspectives and resolutions, hyperspectral data, and machine health monitoring information such as actuator positions, accelerometer readings, and temperature measurements. However, fusing and interpreting this complex, high-dimensional data presents significant challenges, particularly when labeled datasets are unavailable or impractical to obtain. This paper presents a novel approach to multimodal sensor data fusion in manufacturing processes, inspired by the Contrastive Language-Image Pre-training (CLIP) model. We leverage contrastive learning techniques to correlate different data modalities without the need for labeled data, overcoming limitations of traditional supervised machine learning methods in manufacturing contexts. Our proposed method demonstrates the ability to handle and learn encoders for five distinct modalities: visual imagery, audio signals, laser position (x and y coordinates), and laser power measurements. By compressing these high-dimensional datasets into low-dimensional representational spaces, our approach facilitates downstream tasks such as process control, anomaly detection, and quality assurance. The unsupervised nature of our method makes it broadly applicable across various manufacturing domains, where large volumes of unlabeled sensor data are common. We evaluate the effectiveness of our approach through a series of experiments, demonstrating its potential to enhance process monitoring capabilities in advanced manufacturing systems. This research contributes to the field of smart manufacturing by providing a flexible, scalable framework for multimodal data fusion that can adapt to diverse manufacturing environments and sensor configurations. The proposed method paves the way for more robust, data-driven decision-making in complex manufacturing processes.

Contrastive Learning↗

Permeability computation on a REV with an immersed finite element method

An efficient method to compute permeability of fibrous media is presented. An immersed domain approach is used to represent the porous material at its microscopic scale and the flow motion is computed with a stabilized mixed finite element method. Therefore the Stokes equation is solved on the whole domain (including solid part) using a penalty method. The accuracy is controlled by refining the mesh around the solid-fluid interface defined by a level set function. Using homogenisation techniques, the permeability of a representative elementary volume (REV) is computed. The computed permeabilities of regular fibre packings are compared to classical analytical relations found in the bibliography.

36 MATERIALS SCIENCE↗

SU-E-T-324: The Influence of Patient Positioning Uncertainties in Proton Radiotherapy On Proton Range and Dose Distributions

Purpose: Proton radiotherapy allows radiation treatment delivery with high dose gradients. The nature of such dose distributions increases the influence of patient positioning uncertainties on their fidelity when compared to photon radiotherapy. The present work quantitatively analyzes the influence of setup uncertainties on proton range and dose distributions. Methods: 38 clinical passive scattering treatment fields for small lesions in the head were studied. Dose distributions for shifted and rotated patient positions were Monte Carlo-simulated. Proton range uncertainties at the 50% and 90%-dose falloff position were calculated considering 18 arbitrary combinations of maximal patient position shifts and rotations for two patient positioning methods. Normal tissue complication probabilities (NTCPs), equivalent uniform doses (EUDs) and tumor control probabilities (TCPs) were studied for organs at risk (OARs) and target volumes of eight patients. Results: We identified a median 1σ proton range uncertainty at the 50%-dose falloff of 2.8 mm for anatomy-based patient positioning and 1.6 mm for fiducial-based patient positioning as well as 7.2 mm and 5.8 mm for the 90%-dose falloff position respectively. These range uncertainties were correlated to heterogeneity indices (HIs) calculated for each treatment field (38% < R{sup 2} < 50%). A NTCP increase of more than 10% (absolute) was observed for less than 2.9% (anatomy-based positioning) and 1.2% (fiducial-based positioning) of the studied OARs and patient shifts. TCP decreases larger than 10% (absolute) were seen for less than 2.2% of the target volumes or non-existent. EUD changes were up to 178% for OARs and 35% for target volumes. Conclusion: The influence of patient positioning uncertainties on proton range in therapy of small lesions in the human brain and target and OAR dosimetry were studied. Observed range uncertainties were correlated with HIs. The clinical practice of using multiple compensator-smeared treatment beams selected to avoid distal OAR sparing is considered to be safe. J. L. was supported by a scholarship of the University of Vienna.

60 APPLIED LIFE SCIENCES↗

The influence of patient positioning uncertainties in proton radiotherapy on proton range and dose distributions

Purpose: Proton radiotherapy allows radiation treatment delivery with high dose gradients. The nature of such dose distributions increases the influence of patient positioning uncertainties on their fidelity when compared to photon radiotherapy. The present work quantitatively analyzes the influence of setup uncertainties on proton range and dose distributions. Methods: Thirty-eight clinical passive scattering treatment fields for small lesions in the head were studied. Dose distributions for shifted and rotated patient positions were Monte Carlo-simulated. Proton range uncertainties at the 50%- and 90%-dose falloff position were calculated considering 18 arbitrary combinations of maximal patient position shifts and rotations for two patient positioning methods. Normal tissue complication probabilities (NTCPs), equivalent uniform doses (EUDs), and tumor control probabilities (TCPs) were studied for organs at risk (OARs) and target volumes of eight patients. Results: The authors identified a median 1σ proton range uncertainty at the 50%-dose falloff of 2.8 mm for anatomy-based patient positioning and 1.6 mm for fiducial-based patient positioning as well as 7.2 and 5.8 mm for the 90%-dose falloff position, respectively. These range uncertainties were correlated to heterogeneity indices (HIs) calculated for each treatment field (38% < R{sup 2} < 50%). A NTCP increase of more than 10% (absolute) was observed for less than 2.9% (anatomy-based positioning) and 1.2% (fiducial-based positioning) of the studied OARs and patient shifts. For target volumes TCP decreases by more than 10% (absolute) occurred in less than 2.2% of the considered treatment scenarios for anatomy-based patient positioning and were nonexistent for fiducial-based patient positioning. EUD changes for target volumes were up to 35% (anatomy-based positioning) and 16% (fiducial-based positioning). Conclusions: The influence of patient positioning uncertainties on proton range in therapy of small lesions in the human brain as well as target and OAR dosimetry were studied. Observed range uncertainties were correlated with HIs. The clinical practice of using multiple fields with smeared compensators while avoiding distal OAR sparing is considered to be safe.

60 APPLIED LIFE SCIENCES↗

TH-A-18C-10: Dynamic Intensity Weighted Region of Interest Imaging

Purpose: For image guidance tasks full image quality is not required throughout the entire image. With dynamic filtration of the kV imaging beam the noise properties of the CT image can be locally controlled, providing a high quality image around the target volume with a lower quality surrounding region while providing substantial dose sparing to the patient as well as reduced scatter fluence on the detector. Methods: A dynamic collimation device with 3mm copper blades has been designed to mount in place of the bowtie filter on the On-Board Imager (Varian Medical Systems). The beam intensity is reduced by 95% behind the copper filters and the aperture is controlled dynamically to conformally illuminate a given ROI during a standard cone-beam CT scan. A data correction framework to account for the physical effects of the collimator prior to reconstruction was developed. Furthermore, to determine the dose savings and scatter reduction a monte carlo model was built in BEAMnrc with specifics from the Varian Monte Carlo Data Package. The MC model was validated with Gafchromic film. Results: The reconstructed image shows image quality comparable to a standard scan in the specified ROI, with higher noise and streaks in the outer region but still sufficient information for alignment to high contrast structures. The monte carlo modeling showed that the scatter-to-primary ratio was reduced from 1.26 for an unfiltered scan to 0.45 for an intensity weighted scan, suggesting that image quality may be improved in the inner ROI. Dose in the inner region was reduced 10–15% due to reduced scatter and by as much as 75% in the outer region. Conclusion: Dynamic intensity-weighted ROI imaging allows reduction of imaging dose to sensitive organs away from the target region while providing images that retain their utility for patient setup and procedure guidance. Funding was provided in part by Varian Medical Systems and NIH Grants 1RO1CA120540, T32EB002103, S10 RR021039 and P30 CA14599. The contents of this work are solely the responsibility of the authors and do not necessarily represent the official views of any of the supporting organizations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparison of Classical and Aggregation-Based Algebraic Multigrid Preconditioners for High-Fidelity Simulation of Wind Turbine Incompressible Flows

This paper presents a comparison of parallel strong scaling performance of classical and aggregation algebraic multigrid (AMG) preconditioners in the context of wind turbine simulations. Fluid motion is governed by the incompressible Navier--Stokes equations, discretized in space with control-volume finite elements and in time with an inexact projection scheme using an implicit integrator. A discontinuous-Galerkin sliding-mesh algorithm captures rotor motion. The momentum equations are solved with iterative Krylov methods, preconditioned by symmetric Gauss--Seidel (SGS) in Trilinos and $\ell_1$ SGS in hypre. The mass-continuity equation is solved with GMRES preconditioned by AMG and can account for the majority of simulation time. Reducing this continuity solve time is crucial. Wind turbine simulations present two unique challenges for AMG preconditioned solvers: the computational meshes include strongly anisotropic elements, and mesh motion requires matrix reinitialization and computation of preconditioners at each time step. Detailed timing profiles are presented and analyzed, and best practices are discussed for both classical and aggregation-based AMG. Results are presented for simulations of two different wind turbines with up to 6 billion grid points on two different computer architectures. For moving mesh problems that require linear-system reinitialization, the well-established strategy of amortizing preconditioner setup costs over a large number of time steps to reduce the solve time is no longer valid. Instead, results show that faster time to solution is achieved by reducing preconditioner setup costs at the expense of linear-system solve costs. Standard smoothed aggregation with Chebyshev relaxation was found to perform poorly when compared with classical AMG in terms of solve time and robustness. However, plain aggregation was comparable to classical AMG.

97 MATHEMATICS AND COMPUTING↗

Chemical Upcycling of Polyethylene, Polypropylene, and Mixtures to High-Value Surfactants

Conversion of plastic wastes to fatty acids is an attractive means to supplement the sourcing of these high-value, high-volume chemicals. We report a method for transforming polyethylene (PE) and polypropylene (PP) at ~80% conversion to fatty acids with number-average molar masses of up to ~700 and 670 daltons, respectively. The process is applicable to municipal PE and PP wastes and their mixtures. Temperature-gradient thermolysis is the key to controllably degrading PE and PP into waxes and inhibiting the production of small molecules. The waxes are upcycled to fatty acids by oxidation over manganese stearate and subsequent processing. PP ..beta..-scission produces more olefin wax and yields higher acid-number fatty acids than does PE ..beta..-scission. We further convert the fatty acids to high-value, large-market-volume surfactants. Industrial-scale technoeconomic analysis suggests economic viability without the need for subsidies.

deconstruction↗

Dose-Escalated Stereotactic Body Radiation Therapy for Patients With Intermediate- and High-Risk Prostate Cancer: Initial Dosimetry Analysis and Patient Outcomes

Purpose: To report the short-term clinical outcomes and acute and late treatment-related genitourinary (GU) and gastrointestinal (GI) toxicities in patients with intermediate- and high-risk prostate cancer treated with dose-escalated stereotactic body radiation therapy (SBRT). Methods and Materials: Between 2011 and 2014, 24 patients with prostate cancer were treated with SBRT to the prostate gland and proximal seminal vesicles. A high-dose avoidance zone (HDAZ) was created by a 3-mm expansion around the rectum, urethra, and bladder. Patients were treated to a minimum dose of 36.25 Gy in 5 fractions, with a simultaneous dose escalation to a dose of 50 Gy to the target volume away from the HDAZ. Acute and late GU and GI toxicity outcomes were measured according to the National Cancer Institute Common Terminology Criteria for Adverse Events toxicity scale, version 4. Results: The median follow-up was 25 months (range, 18-45 months). Nine patients (38%) experienced an acute grade 2 GU toxicity, which was medically managed, and no patients experienced an acute grade 2 GI toxicity. Two patients (8%) experienced late grade 2 GU toxicity, and 2 patients (8%) experienced late grade 2 GI toxicity. No acute or late grade ≥3 GU or GI toxicities were observed. The 24-month prostate-specific antigen relapse-free survival outcome for all patients was 95.8% (95% confidence interval 75.6%-99.4%), and both biochemical failures occurred in patients with high-risk disease. All patients are currently alive at the time of this analysis and continue to be followed. Conclusions: A heterogeneous prostate SBRT planning technique with differential treatment volumes (low dose: 36.25 Gy; and high dose: 50 Gy) with an HDAZ provides a safe method of dose escalation. Favorable rates of biochemical control and acceptably low rates of acute and long-term GU and GI toxicity can be achieved in patients with intermediate- and high-risk prostate cancer treated with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Property Composition Models For RPP-WTP LAW Glasses (Final Report)

This report describes the development of property-composition models for low-activity waste (LAW) glasses for the River Protection Project Waste Treatment Plant (RPP-WTP) at the Hanford site. The RPP-WTP will separate Hanford tank wastes into LAW and high-level waste (HLW) streams and each stream will be vitrified separately. The development of LAW and HLW glass formulations for the RPP-WTP has been reported previously and is an ongoing activity. Acceptable formulations must meet a variety of processability, product quality, and waste loading requirements that are dictated either by the RPP-WTP contract or by the characteristics of the particular treatment processes that have been selected. These requirements amount to constraints on the acceptable ranges of certain glass properties. These properties are determined first and foremost by the composition of the glass or glass melt. Thus, while there is no direct way of controlling the glass properties of interest during production, there are simple and extremely effective methods of achieving the same result by instead controlling the glass composition. This basic principle is no different from that used to produce enormous volumes of commercial glass to meet exacting product specifications. An essential difference in waste vitrification, however, is that one of the raw materials (the waste itself) can be subject to considerable compositional uncertainty and variability. Thus, waste vitrification facilities and associated process control systems (of which, the operating envelope in glass formulation space is a key part) must, of course, be designed to be robust with respect to such variations. The determination of quantitative relationships between the glass properties that must be controlled and the glass composition can play an important role in the development of such facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Magnus: A New Resistive MHD Code with Heat Flow Terms

We present a new magnetohydrodynamic (MHD) code for the simulation of wave propagation in the solar atmosphere, under the effects of electrical resistivity—but not dominant—and heat transference in a uniform 3D grid. The code is based on the finite-volume method combined with the HLLE and HLLC approximate Riemann solvers, which use different slope limiters like MINMOD, MC, and WENO5. In order to control the growth of the divergence of the magnetic field, due to numerical errors, we apply the Flux Constrained Transport method, which is described in detail to understand how the resistive terms are included in the algorithm. In our results, it is verified that this method preserves the divergence of the magnetic fields within the machine round-off error (∼1×10{sup −12}). For the validation of the accuracy and efficiency of the schemes implemented in the code, we present some numerical tests in 1D and 2D for the ideal MHD. Later, we show one test for the resistivity in a magnetic reconnection process and one for the thermal conduction, where the temperature is advected by the magnetic field lines. Moreover, we display two numerical problems associated with the MHD wave propagation. The first one corresponds to a 3D evolution of a vertical velocity pulse at the photosphere–transition–corona region, while the second one consists of a 2D simulation of a transverse velocity pulse in a coronal loop.

79 ASTRONOMY AND ASTROPHYSICS↗

Patient geometry-driven information retrieval for IMRT treatment plan quality control

Purpose: Intensity modulated radiation therapy (IMRT) treatment plan quality depends on the planner's level of experience and the amount of time the planner invests in developing the plan. Planners often unwittingly accept plans when further sparing of the organs at risk (OARs) is possible. The authors propose a method of IMRT treatment plan quality control that helps planners to evaluate the doses of the OARs upon completion of a new plan. Methods: It is achieved by comparing the geometric configurations of the OARs and targets of a new patient with those of prior patients, whose plans are maintained in a database. They introduce the concept of a shape relationship descriptor and, specifically, the overlap volume histogram (OVH) to describe the spatial configuration of an OAR with respect to a target. The OVH provides a way to infer the likely DVHs of the OARs by comparing the relative spatial configurations between patients. A database of prior patients is built to serve as an external reference. At the conclusion of a new plan, planners search through the database and identify related patients by comparing the OAR-target geometric relationships of the new patient with those of prior patients. The treatment plans of these related patients are retrieved from the database and guide planners in determining whether lower doses delivered to the OARs in the new plan are feasible. Results: Preliminary evaluation is promising. In this evaluation, they applied the analysis to the parotid DVHs of 32 prior head-and-neck patients, whose plans are maintained in a database. Each parotid was queried against the other 63 parotids to determine whether a lower dose was possible. The 17 parotids that promised the greatest reduction in D{sub 50} (DVH dose at 50% volume) were flagged. These 17 parotids came from 13 patients. The method also indicated that the doses of the other nine parotids of the 13 patients could not be reduced, so they were included in the replanning process as controls. Replanning with an effort to reduce D{sub 50} was conducted on these 26 parotids. After replanning, the average reductions for D{sub 50} of the 17 flagged parotids and nine unflagged parotids were 6.6 and 1.9 Gy, respectively. These results demonstrate that the quality control method has accurately identified not only the parotids that require dose reductions but also those for which dose reductions are marginal. Originally, 11 of out the 17 flagged parotids did not meet the Radiation Therapy Oncology Group sparing goal of V(30 Gy)<50%. Replanning reduced them to three. Additionally, PTV coverage and OAR sparing of the original plans were compared to those of the replans by using pairwise Wilcoxon p test. The statistical comparisons show that replanning compromised neither PTV coverage nor OAR sparing. Conclusions: This method provides an effective quality control mechanism for evaluating the DVHs of the OARs. Adoption of such a method will advance the quality of current IMRT planning, providing better treatment plan consistency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-72: A Retrospective Correlation Analysis On Dose-Volume Control Points and Treatment Outcomes

Purpose: To quantify correlation between dose-volume control points and treatment outcomes. Specifically, two outcomes are analyzed: occurrence of radiation induced dysphagia and target complications. The results inform the treatment planning process when competing dose-volume criteria requires relaxations. Methods: 32 patients, treated with whole-field sequential intensity modulated radiation therapy during 2009–2010 period, are considered for this study. Acute dysphagia that is categorized into 3 grades is observed on all patients. 3 patients are observed in grade 1, 17 patients in grade 2, and 12 patients in grade 3. Ordinal logistic regression is employed to establish correlations between grades of dysphagia and dose to cervico-thoracic esophagus. Particularly, minimum (Dmin), mean (Dmean), and maximum (Dmax) dose control points are analyzed. Additionally, target complication, which includes local-regional recurrence and/or distant metastasis, is observed on 4 patients. Binary logistic regression is used to quantify correlation between target complication and four dose control points. Namely, ICRU recommended dose control points, D2, D50, D95, and D98 are analyzed. Results: For correlation with dysphagia, Dmin on cervico-thoracic esophagus is statistically significant (p-value = 0.005). Additionally, Dmean on cervico-thoracic esophagus is also significant in association with dysphagia (p-value = 0.012). However, no correlation was observed between Dmax and dysphagia (p-value = 0.263). For target complications, D50 on the target is a statistically significant dose control point (p-value = 0.032). No correlations were observed between treatment complications and D2 (p-value = 0.866), D95 (p-value = 0.750), and D98 (p-value = 0.710) on the target. Conclusion: Significant correlations are observed between radiation induced dysphagia and Dmean (and Dmin) to cervico-thoracic esophagus. Additionally, correlation between target complications and median dose to target (D50) is observed. Quantification of these correlations can inform treatment planners when any competing objectives requires relaxation of target D50 or Dmean (or Dmin) to cervico-thoracic esophagus.

60 APPLIED LIFE SCIENCES↗

Reporting the Radionuclide Inventory of the DWPF Product

In the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS), the radionuclides contained in the liquid high-level waste currently stored at SRS are being converted into a durable borosilicate glass. This glass in its sealed stainless-steel canister, the DWPF product, eventually must be sent to a federal repository for final disposal. In order to ensure that the DWPF product is suitable for acceptance by the U. S. Department of Energy’s (DOE) Civilian Radioactive Waste Management System (CRWMS)*, the DOE Office of Environmental Management (DOE-EM) established the Waste Acceptance Product Specifications for Vitrified High-Level Waste Forms (WAPS). DOE-EM is tentatively performing surrogate CRWMS waste acceptance functions, as the office was eliminated in 2009, for review and concurrence of technical baseline documents and waste form non conformances. The specifications are divided into five sections, dealing with the waste form (borosilicate glass) itself, the canister, the canistered waste form, quality assurance, and documentation and other administrative requirements. The DWPF is required to document its compliance with the specifications in the Waste Form Compliance Plan (WCP), the Waste Form Qualification Report (WQR), the Production Records, and the Storage and Shipping Records. The WCP provides general information about the DWPF process and product, and a general description of the methods and programs by which the DWPF will demonstrate compliance with each specification in the WAPS. The WCP was vital to DWPF startup with respect to operations planning and also assurance to DOE that the canistered waste forms would be acceptable for disposal at any future High-Level Waste (HLW) geologic repository. The WQR is a compilation of the results of the testing and analysis programs identified in the WCP. The WQR details the method of compliance with each specification, and the testing performed to demonstrate the effectiveness of each method. The WQR is published in separate volumes which each correspond to one or more of the specifications. The WQR also contains a description of the DWPF’s Glass Product Control Program. Each volume contains Part and Item designators which indicate the corresponding item(s) in the WCP. The Production Records, and the Storage and Shipping Records document that each DWPF product has been produced and stored in compliance with the WAPS. This document, Volume 4 of the WQR, responds to WAPS Specifications 1.2.2, 1.6, and 3.14 which require that the DWPF report the radionuclide inventory of each canistered waste form, and of each waste type. This volume describes the systems the DWPF uses to determine and report the radionuclide inventory of the glass product, and provides evidence that these systems allow the DWPF to satisfy the WAPS specification. This volume of the WQR has been prepared to establish that methods are available to determine and report the radionuclide inventory, and that the DWPF is ready to collect the facility-specific data necessary to provide definitive estimates of the errors associated with the use of these methods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Applying Infrared Thermography as a Quality-Control Tool for the Rapid Detection of Proton-Electrolyte-Membrane-Fuel-Cell Catalyst-Layer-Thickness Variations

As fuel cells become more prominent, new manufacturing and production methods are needed to enable increased volumes with high quality. One necessary component of this industrial growth will be the accurate measurement of the variability of a wide range of material properties during the manufacturing process. In this study, a method to detect defects in fuel cell catalyst layers is investigated through experiment and mathematical simulation. The method uses infrared thermography and direct-current electronic-excitation methods to detect variations in platinum-containing catalyst-layer thickness with high spatial and temporal resolution. Data analysis, operating-condition impacts, and detection limits are explored, showing the measurement of defects on the millimeter length scale. Overall, the experimental and modeling results demonstrate great potential of this technique as a nondestructive method to measure defects that is amenable to use on roll-to-roll manufacturing lines.

08 HYDROGEN↗

Adaptive Image-Guided Radiotherapy (IGRT) Eliminates the Risk of Biochemical Failure Caused by the Bias of Rectal Distension in Prostate Cancer Treatment Planning: Clinical Evidence

Purpose: Rectal distension has been shown to decrease the probability of biochemical control. Adaptive image-guided radiotherapy (IGRT) corrects for target position and volume variations, reducing the risk of biochemical failure while yielding acceptable rates of gastrointestinal (GI)/genitourinary (GU) toxicities. Methods and Materials: Between 1998 and 2006, 962 patients were treated with computed tomography (CT)-based offline adaptive IGRT. Patients were stratified into low (n = 400) vs. intermediate/high (n = 562) National Comprehensive Cancer Network (NCCN) risk groups. Target motion was assessed with daily CT during the first week. Electronic portal imaging device (EPID) was used to measure daily setup error. Patient-specific confidence-limited planning target volumes (cl-PTV) were then constructed, reducing the standard PTV and compensating for geometric variation of the target and setup errors. Rectal volume (RV), cross-sectional area (CSA), and rectal volume from the seminal vesicles to the inferior prostate (SVP) were assessed on the planning CT. The impact of these volumetric parameters on 5-year biochemical control (BC) and chronic Grades {>=}2 and 3 GU and GI toxicity were examined. Results: Median follow-up was 5.5 years. Median minimum dose covering cl-PTV was 75.6 Gy. Median values for RV, CSA, and SVP were 82.8 cm{sup 3}, 5.6 cm{sup 2}, and 53.3 cm{sup 3}, respectively. The 5-year BC was 89% for the entire group: 96% for low risk and 83% for intermediate/high risk (p < 0.001). No statistically significant differences in BC were seen with stratification by RV, CSA, and SVP in quartiles. Maximum chronic Grades {>=}2 and 3 GI toxicities were 21.2% and 2.9%, respectively. Respective values for GU toxicities were 15.5% and 4.3%. No differences in GI or GU toxicities were noted when patients were stratified by RV. Conclusions: Incorporation of adaptive IGRT reduces the risk of geometric miss and results in excellent biochemical control that is independent of rectal volume/distension while maintaining very low rates of chronic GI toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RadVolViz: An Information Display-Inspired Transfer Function Editor for Multivariate Volume Visualization

In volume visualization transfer functions are widely used for mapping voxel properties to color and opacity. Typically, volume density data are scalars which require simple 1D transfer functions to achieve this mapping. If the volume densities are vectors of three channels, one can straightforwardly map each channel to either red, green or blue, which requires a trivial extension of the 1D transfer function editor. Here, we devise a new method that applies to volume data with more than three channels. These types of data often arise in scientific scanning applications, where the data are separated into spectral bands or chemical elements. Our method expands on prior work in which a multivariate information display, RadViz, was fused with a radial color map, in order to visualize multi-band 2D images. In this work, we extend this joint interface to blended volume rendering. The information display allows users to recognize the presence and value distribution of the multivariate voxels and the joint volume rendering display visualizes their spatial distribution. We design a set of operators and lenses that allow users to interactively control the mapping of the multivariate voxels to opacity and color. This enables users to isolate or emphasize volumetric structures with desired multivariate properties. Furthermore, it turns out that our method also enables more insightful displays even for RGB data. We demonstrate our method with three datasets obtained from spectral electron microscopy, high energy X-ray scanning, and atmospheric science.

36 MATERIALS SCIENCE↗

POINT: Partially Observable Imitation Network for Traffic Signal Control

Smart traffic signals bring together transportation infrastructure and advance technologies to improve the mobility and efficiency of urban transportation network. Adaptive traffic signal control studies can be categorized into modeling-based approaches and learning-based approaches. In order to take advantages of these two systems, this study developed an offline-online combined Partial Observable Imitation Network for Traffic signal control (POINT). In the offline system, the traffic signal timing optimization problem was formulated as a Mixed Integer Nonlinear Programming (MINLP) given complete traffic information, i.e., second-by-second speeds and locations of all vehicles. Furthermore, the objective of MINLP is to minimize total travel delays considering individual vehicle trajectories under Connected Vehicle (CV) environment. The calculated optimal solutions under various traffic conditions were considered as the ”expert” decisions. In the online system, an imitation neural network model was developed to learn the ”expert” signal plans generated from offline system. Given partial observable traffic conditions in real time, e.g., the aggregate-level of traffic volume, the POINT model can compute the signal timing parameters in the online system. The numerical results demonstrated that the proposed method outperformed other state-of-the-art signal control method under high and unbalanced traffic demand levels in terms of reducing travel delays and queue length.

33 ADVANCED PROPULSION SYSTEMS↗

Development of Dose-Volume Relation Model for Gamma Knife Surgery of Non-Skull Base Intracranial Meningiomas

Purpose: To provide a dose-volume relationship for gamma knife surgery (GKS) of non-skull base intracranial meningiomas. Methods and Materials: The radiologic outcomes of GKS of 82 imaging-defined benign meningiomas located at non-skull base areas were analyzed. A total of 80 patients were included and all underwent treatment with GKS as the first and the only treatment modality. The mean patient age was 55.0 years (range, 26-78) and the mean tumor volume was 5.6 cm{sup 3} (range, 0.5-16.8). On average, 14.6 Gy (range, 10-20) was applied to the 50% isodose surface. The binary logistic regression method was applied to find prognostic factors of signal change (SC) on T{sub 2}-weighted magnetic resonance imaging after GKS. Results: The actuarial tumor control rate was 91.6% at 5 years. A total of 29 lesions (35.4%) showed newly developed or aggravated SCs. The volume irradiated {>=}14 Gy was the only statistically significant (p < .01) prognostic factor of SC. A dose-volume relation model obtained from the cases without SC estimated a 12.2% SC probability. Conclusion: This model can be used in GKS to treat small- to medium-size (<9.2 cm{sup 3}) non-skull base meningiomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗