Search NASA⌕ Search

SEARCH · Search NASA

Results for “controlled humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Understanding the Cathode Electrochemistry of Humidified Solid‐State Lithium‐Oxygen Batteries

Lithium-oxygen batteries (LOBs) possess a high theoretical energy density, making them potential candidates for next-generation energy storage. However, challenges such as reactive oxygen species-induced component degradation hinder their practical use. Inorganic solid-state electrolytes offer an alternative to degradation-prone aprotic electrolytes, while also protecting lithium anodes from potential atmospheric reactants. Here, this study explores the cathode electrochemistry of solid-state LOBs using humidified oxygen, which forms an aqueous catholyte during initial cycling, thereby improving cathode-electrolyte contact. To quantitatively analyze the cathode electrochemistry, a ‘Humidity-Incorporated’ Differential Electrochemical Gas Monitoring System (HiDEMS) is developed to control humidity and monitor gas consumption and evolution in real time. When studying a Li-O 2 cell that employs a NASICON-type Li 1.3 Al 0.3 Ti 1.7 (PO 4 ) 3 (LATP) solid electrolyte and a porous carbon cathode, a shift in discharge products from Li 2 O 2 to LiOH is observed over repeated cycles. While Li 2 O 2 evolves O 2 during charging, LiOH oxidation leads to minimal O 2 release and increased CO 2 production, originating from oxidation of carbon electrodes. Further, dissolution of Al and P from LATP is observed, likely driven by the formation of the alkaline catholyte. The findings highlight the need for carbon-free cathode materials and more stable solid-state conductors to minimize side reactions and improve rechargeability in humidified solid-state Li-O 2 batteries.

LATP degradation↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

A new method for the determination of thin film porosity

Internal reflection spectroscopy may be used to determine presence of water in thin film pores. Presence of water in such pores is function of relative humidity and pore size. Thus, one can determine pore size by controlling humidity. Fluids with surface tension different from that of water can be used to detect pores.

Beck, T. R.↗

Automation of closed environments in space for human comfort and safety

The Environmental Control and Life Support System (ECLSS) for the Space Station Freedom and future colonization of the Moon and Mars presents new challenges for present technologies. Current plans call for a crew of 8 to live in a safe, shirt-sleeve environment for 90 days without ground support. Because of these requirements, all life support systems must be self-sufficient and reliable. The ECLSS is composed of six subsystems. The temperature and humidity control (THC) subsystem maintains the cabin temperature and humidity at a comfortable level. The atmosphere control and supply (ACS) subsystem insures proper cabin pressure and partial pressures of oxygen and nitrogen. To protect the space station from fire damage, the fire detection and suppression (FDS) subsystem provides fire sensing alarms and extinguishers. The waste management (WM) subsystem compacts solid wastes for return to Earth, and collects urine for water recovery. Because it is impractical, if not impossible, to supply the station with enough fresh air and water for the duration of the space station's extended mission, these elements are recycled. The atmosphere revitalization (AR) subsystem removes CO2 and other dangerous contaminants from the air. The water recovery and management (WRM) subsystem collects and filters condensate from the cabin to replenish potable water supplies, and processes urine and other waste waters to replenish hygiene water supplies. These subsystems are not fully automated at this time. Furthermore, the control of these subsystems is not presently integrated; they are largely independent of one another. A fully integrated and automated ECLSS would increase astronauts' productivity and contribute to their safety and comfort. The Kansas State University Advanced Design Team is in the process of researching and designing controls for the automation of the ECLSS for Space Station Freedom and beyond. The approach chosen to solve this problem is to divide the design into three phases. The first phase is to research the ECLSS as a whole system and then concentrate efforts on the automation of a single subsystem. The AR subsystem was chosen for our focus. During the second phase, the system control process will then be applied to the AR subsystem.

Source record↗

Space Station environmental control and life support system distribution and loop closure studies

The NASA Space Station's environmental control and life support system (ECLSS) encompasses functional elements concerned with temperature and humidity control, atmosphere control and supply, atmosphere revitalization, fire detection and suppression, water recovery and management, waste management, and EVA support. Attention is presently given to functional and physical module distributions of the ECLSS among these elements, with a view to resource requirements and safety implications. A strategy of physical distribution coupled with functional centralization is for the air revitalization and water reclamation systems. Also discussed is the degree of loop closure desirable in the initial operational capability status Space Station's oxygen and water reclamation loops.

Humphries, William R.↗

International Space Station Atmosphere Control and Supply, Atmosphere Revitalization, and Water Recovery and Management Subsystem - Verification for Node 1

The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper provides a summary of the nominal operation of the Node 1 ACS, AR, and WRM design and detailed Element Verification methodologies utilized during the Qualification phase for Node 1.

Williams, David E.↗

International Space Station Environmental Control and Life Support Emergency Response Verification for Node 1

The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper provides a summary of the Node 1 Emergency Response capability, which includes nominal and off-nominal FDS operation, off nominal ACS operation, and off-nominal THC operation. These subsystems provide the capability to help aid the crew members during an emergency cabin depressurization, a toxic spill, or a fire. The paper will also provide a discussion of the detailed Node 1 ECLS Element Verification methodologies for operation of the Node 1 Emergency Response hardware operations utilized during the Qualification phase.

Williams, David E.↗

International Space Station Environmental Control and Life Support System Acceptance Testing for Node 1 Atmosphere Control and Supply Subsystem

The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper provides a summary of the Node 1 ECLS ACS subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for that subsystem.

Williams, David E.↗

International Space Station United States Laboratory Module Water Recovery Management Subsystem Verification from Flight 5A to Stage ULF2

The International Space Station (ISS) Environmental Control and Life Support (ECLS) system comprises of seven subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), Vacuum System (VS), Water Recovery and Management (WRM), and Waste Management (WM). This paper provides a summary of the nominal operation of the United States (U.S.) Laboratory Module WRM design and detailed element methodologies utilized during the Qualification phase of the U.S. Laboratory Module prior to launch and the Qualification of all of the modification kits added to it from Flight 5A up and including Stage ULF2.

Williams, David E.↗

Modeling Geometric Arrangements of TiO2-Based Catalyst Substrates and Isotropic Light Sources to Enhance the Efficiency of a Photocatalystic Oxidation (PCO) Reactor

The closed confined environments of the ISS, as well as in future spacecraft for exploration beyond LEO, provide many challenges to crew health. One such challenge is the availability of a robust, energy efficient, and re-generable air revitalization system that controls trace volatile organic contaminants (VOCs) to levels below a specified spacecraft maximum allowable concentration (SMAC). Photocatalytic oxidation (PCO), which is capable of mineralizing VOCs at room temperature and of accommodating a high volumetric flow, is being evaluated as an alternative trace contaminant control technology. In an architecture of a combined air and water management system, placing a PCO unit before a condensing heat exchanger for humidity control will greatly reduce the organic load into the humidity condensate loop ofthe water processing assembly (WPA) thereby enhancing the life cycle economics ofthe WPA. This targeted application dictates a single pass efficiency of greater than 90% for polar VOCs. ~ Although this target was met in laboratory bench-scaled reactors, no commercial or SBIR-developed prototype PCO units examined to date have achieved this goal. Furthermore, the formation of partial oxidation products (e.g., acetaldehyde) was not eliminated. It is known that single pass efficiency and partial oxidation are strongly dependent upon the contact time and catalyst illumination, hence the requirement for an efficient reactor design. The objective of this study is to maximize the apparent contact time and illuminated catalyst surface area at a given reactor volume and volumetric flow. In this study, a Ti02-based photocatalyst is assumed to be immobilized on porous substrate panels and illumination derived from linear isotropic light sources. Mathematical modeling using computational fluid dynamics (CFD) analyses were performed to investigate the effect of: 1) the geometry and configuration of catalyst-coated substrate panels, 2) porosity of the supporting substrate, and 3) varying the light source and spacing on contact time and illuminated catalyst area.

Richards, Jeffrey T.↗

A multiphase flow model of water droplets dielectrophoretic-induced air dehumidification phenomena

Air humidity in indoor spaces plays a critical role in human comfort and health. Dehumidification systems are used for building humidity controls, but they can take significant energy consumption, especially in geographic locations with high outdoor humidity and warm climates. Consequently, there is a growing demand for innovative dehumidification processes that consume minimal energy. Dielectrophoretic air dehumidification represents one such promising approach. However, it has not garnered significant attention due to the absence of engineering models and simulation tools capable of evaluating its performance and limitations at large-scale airflows. A new numerical multiphase CFD model, which is also experimentally validated, is developed in a customized Reacting Foam solver based on OpenFOAM® version 9. The newly developed model seeks to decrease substantial energy consumption and lower costs by leveraging the dielectrophoretic phenomenon to regulate moisture levels in the air. The solver integrates a hybrid Eulerian-Lagrangian framework to track the droplet's trajectory and growth rate while solving the continuum equations for the moist air. An electrospray produces electrically charged droplets, which grow during their in-flight trajectories as water vapor condenses onto their surfaces. The role of electrostatic forces in promoting vapor condensation within a high-gradient electrical field is investigated, and the dielectrophoretic vapor nucleation process on charged water droplets is discussed. The CFD model was validated against results from the literature and from proof-of-concept experiments conducted by the authors, which showed a 2 % air dehumidification with a single electrospray and airflow rate of 5 cubic feet per minute. The simulation results indicated that augmenting the number of electrically charged spray droplets increased the dehumidification of the air to 25 %. The initial mean droplet diameter, the orientation of the injector and relative humidity significantly influence the assessment of dehumidification. As a result, scaling up this approach to larger airflow volumes is identified as a potential future research direction.

42 ENGINEERING↗

Humidity trends imply increased sensitivity to clouds in a warming Arctic

Infrared radiative processes are implicated in Arctic warming and sea-ice decline. The infrared cloud radiative effect (CRE) at the surface is modulated by cloud properties; however, CRE also depends on humidity because clouds emit at wavelengths that are semi-transparent to greenhouse gases, most notably water vapour. Here we show how temperature and humidity control CRE through competing influences between the mid- and far-infrared. At constant relative humidity, CRE does not decrease with increasing temperature/absolute humidity as expected, but rather is found to be approximately constant for temperatures characteristic of the Arctic. This stability is disrupted if relative humidity varies. Our findings explain observed seasonal and regional variability in Arctic CRE of order 10Wm 2 . With the physical properties of Arctic clouds held constant, we calculate recent increases in CRE of 1–5Wm 2 in autumn and winter, which are projected to reach 5–15Wm 2 by 2050, implying increased sensitivity of the surface to clouds.

54 ENVIRONMENTAL SCIENCES↗

Aerosol Inlets for a Mid-Sized Uncrewed Aerial System (UAS)

The purpose of this technical report is to document the efforts to design and test two inlet systems for aerosol sampling suitable for deployment on a medium-sized fixed-wing Uncrewed Aerial System (UAS). This work, which was supported by the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility, was conducted at the Pacific Northwest National Laboratory (PNNL) for the ARM Aircraft Facility (AAF) starting in November 2017. The current work is a part of AAF efforts to instrument the ArcticShark (a mid-sized UAS owned and operated by the AAF) for atmospheric research and develop a scientific payload for deployment on a similar-sized UAS with minimal adaptation and integration. An aerosol inlet system is necessary to sample and transport ambient air sample to the scientific instrumentation with minimal distortions to the aerosols. Two isokinetic aerosol inlets were designed: the first is a simple passive system for a single instrument suitable to be installed in a wing pylon; the second is a system with active control designed to sample and distribute air among several heterogeneous instruments and to provide basic humidity control of the air sample so that the measured aerosol parameters should correspond to “dry” conditions (a common requirement). Both systems could be easily adapted for deployment on another platform and/or with a different set of instrumentation. Several conducted flight tests showed that the inlets’ performance met our design goals.

54 ENVIRONMENTAL SCIENCES↗

Aerosol Inlets for a Mid-Sized Uncrewed Aerial System (UAS)

The purpose of this technical report is to document the efforts to design and test two inlet systems for aerosol sampling suitable for deployment on a medium-sized fixed-wing Uncrewed Aerial System (UAS). This work, which was supported by the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility, was conducted at the Pacific Northwest National Laboratory (PNNL) for the ARM Aircraft Facility (AAF) starting in November 2017. The current work is a part of AAF efforts to instrument the ArcticShark (a mid-sized UAS owned and operated by the AAF) for atmospheric research and develop a scientific payload for deployment on a similar-sized UAS with minimal adaptation and integration. An aerosol inlet system is necessary to sample and transport ambient air sample to the scientific instrumentation with minimal distortions to the aerosols. Two isokinetic aerosol inlets were designed: the first is a simple passive system for a single instrument suitable to be installed in a wing pylon; the second is a system with active control designed to sample and distribute air among several heterogeneous instruments and to provide basic humidity control of the air sample so that the measured aerosol parameters should correspond to “dry” conditions (a common requirement). Both systems could be easily adapted for deployment on another platform and/or with a different set of instrumentation. Several conducted flight tests showed that the inlets’ performance met our design goals.

42 ENGINEERING↗

Requirements and Sizing Investigation for the Constellation Space Suit Portable Life Support System Trace Contaminant Control

This presentation summarized the results of a trade study that evaluated whether trace contaminant control within the Constellation Spacesuit PLSS could be achieved without a Trace Contaminant Control System (TCCS) by relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Mallory Jennings and Dr. Glenn Waguespack studied trace contaminant generation rates to verify that values reflected the latest designs for Constellation spacesuit system pressure garment materials and PLSS hardware. They also calculated TCCS sizing and conducted a literature survey to review the latest developments in trace contaminant technologies.

Jennings, Mallory A.↗

Past and present environmental control and life support systems on manned spacecraft

The spacecraft environmental control and life support systems (ECLSS) for Mercury, Gemini, Apollo, Skylab, Spacelab, the Space Shuttle Orbiter, and Space Station Freedom are reviewed, in addition to the ECLSS on Soviet spacecraft Vostok, Voskhod, Soyuz, Salyut Space Stations, the Buran Space Shuttle, and the Mir Space Station. Focus is placed on atmosphere control and supply, atmosphere revitalization, potable and supply water systems, waste-management systems, temperature and humidity control, water recovery and management, and fire detection and suppression. It is noted that the ECLSS evolution will continue during the lifetime of Space Station Freedom, leading to further simplifications and closure of the system which will become a controlled ecological life support system (CELSS).

Diamant, Bryce L.↗

Atmosphere control

Atmospheric control studies emphasized the carbon dioxide problem. Trace contaminants are removed by solid adsorbents and by catalytic oxidation. Humidity control and storage systems for atmospheric constituents are briefly summarized.

Jones, W. L.↗