Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Modeling the Contribution of Precipitation Loss to a Radiation Belt Electron Dropout Observed by Van Allen Probes

A drift-diffusion model is used to simulate the low-altitude electron distribution, accounting for azimuthal drift, pitch angle diffusion, and atmospheric backscattering effects during a rapid electron dropout event on 21st August 2013, at L = 4.5. Additional external loss effects are introduced during times when the low-altitude electron distribution cannot be reproduced by diffusion alone. Here, the model utilizes low-altitude electron count rate data from five POES/MetOp satellites to quantify pitch angle diffusion rates. Low-altitude data provides critical constraint on the model because it includes the drift loss cone region where the electron distribution in longitude is highly dependent on the balance between azimuthal drift and pitch angle diffusion. Furthermore, a newly derived angular response function for the detectors onboard POES/MetOp is employed to accurately incorporate the bounce loss cone measurements, which have been previously contaminated by electrons from outside the nominal field-of-view. While constrained by low-altitude data, the model also shows reasonable agreement with high-altitude data. Pitch angle diffusion rates during the event are quantified and are faster at lower energies. Precipitation is determined to account for all of the total loss observed for 450 keV electrons, 88% for 600 keV and 38% for 900 keV. Predictions made in the MeV range are deemed unreliable as the integral energy channels E3 and P6 fail to provide the necessary constraint at relativistic energies.

79 ASTRONOMY AND ASTROPHYSICS↗

A three-year dataset supporting research on building energy management and occupancy analytics

Abstract This paper presents the curation of a monitored dataset from an office building constructed in 2015 in Berkeley, California. The dataset includes whole-building and end-use energy consumption, HVAC system operating conditions, indoor and outdoor environmental parameters, as well as occupant counts. The data were collected during a period of three years from more than 300 sensors and meters on two office floors (each 2,325 m 2 ) of the building. A three-step data curation strategy is applied to transform the raw data into research-grade data: (1) cleaning the raw data to detect and adjust the outlier values and fill the data gaps; (2) creating the metadata model of the building systems and data points using the Brick schema; and (3) representing the metadata of the dataset using a semantic JSON schema. This dataset can be used in various applications—building energy benchmarking, load shape analysis, energy prediction, occupancy prediction and analytics, and HVAC controls—to improve the understanding and efficiency of building operations for reducing energy use, energy costs, and carbon emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Excluded volume and ion-ion correlation effects on the ionic atmosphere around B-DNA: Theory, simulations, and experiments

The ionic atmosphere around a nucleic acid regulates its stability in aqueous salt solutions. One major source of complexity in biological activities involving nucleic acids arises from the strong influence of the surrounding ions and water molecules on their structural and thermodynamic properties. Here, we implement a classical density functional theory for cylindrical polyelectrolytes embedded in aqueous electrolytes containing explicit (neutral hard sphere) water molecules at experimental solvent concentrations. Our approach allows us to include ion correlations as well as solvent and ion excluded volume effects for studying the structural and thermodynamic properties of highly charged cylindrical polyelectrolytes. Several models of size and charge asymmetric mixtures of aqueous electrolytes at physiological concentrations are studied. Our results are in good agreement with Monte Carlo simulations. Our numerical calculations display significant differences in the ion density profiles for the different aqueous electrolyte models studied. However, similar results regarding the excess number of ions adsorbed to the B-DNA molecule are predicted by our theoretical approach for different aqueous electrolyte models. These findings suggest that ion counting experimental data should not be used alone to validate the performance of aqueous DNA-electrolyte models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of distribution selection methods

Many methods have been suggested to choose between distributions. There has been relatively less study to examine whether these methods accurately recover the distributions being studied. Here, this research compares several popular distribution selection methods through a Monte Carlo simulation study and identifies which are robust for several types of discrete probability distributions. In addition, we study whether it matters that the distribution selection method does not accurately pick the correct probability distribution by calculating the expected distance, which is the amount of information lost for each distribution selection method compared to the generating probability distribution.

97 MATHEMATICS AND COMPUTING↗

A Thin Alumina Film as a Tritium Adsorption Inhibitor for Stainless Steel 316

The effect of a thin alumina coating on stainless-steel 316 (SS316) samples on tritium adsorption and transport are discussed. Compact films of alumina were produced on the surfaces of pristine SS316 samples using an atomic layer deposition (ALD) technique. Subsequently, these samples were exposed for 24 hours to a deuterium-tritium gas mixture (P T =0.5 atm, 25°C). A combination of methods including selective-etching and programmed thermal desorption were employed to assess both, the depth profile of the tritium concentration in the sample and the total quantity of tritium absorbed respectively. Tritium was quantitatively determined through the measurement of beta radioactivity using liquid-scintillation counting techniques. Data suggest that SS316 with a thin film of alumina reduces the total tritium uptake by ~25% relative to uncoated samples. Significantly, such films appear to reduce, by a factor of 200, tritium diffusion into SS316 and therefore constitute an effective barrier against tritium transport. This observation is of practical importance for tritium and, generally, reactive gas handling.

36 MATERIALS SCIENCE↗

DETERMINATION OF STOCHASTIC ACCELERATION MODEL CHARACTERISTICS IN SOLAR FLARES

Following our recent paper, we have developed an inversion method to determine the basic characteristics of the particle acceleration mechanism directly and non-parametrically from observations under the leaky box framework. Earlier, we demonstrated this method for obtaining the energy dependences of the escape time and pitch angle scattering time. Here, by converting the Fokker-Planck equation to its integral form, we derive the energy dependences of the energy diffusion coefficient and direct acceleration rate for stochastic acceleration in terms of the accelerated and escaping particle spectra. Combining the regularized inversion method of Piana et al. and our procedure, we relate the acceleration characteristics in solar flares directly to the count visibility data from RHESSI. We determine the timescales for electron escape, pitch angle scattering, energy diffusion, and direct acceleration at the loop top acceleration region for two intense solar flares based on the regularized electron flux spectral images. The X3.9 class event shows dramatically different energy dependences for the acceleration and scattering timescales, while the M2.1 class event shows a milder difference. The discrepancy between the M2.1 class event and the stochastic acceleration model could be alleviated by a turbulence spectrum that is much steeper than the Kolmogorov-type spectrum. A likely explanation of the X3.9 class event could be that the escape of electrons from the acceleration region is not governed by a random walk process, but instead is affected by magnetic mirroring, in which the scattering time is proportional to the escape time and has an energy dependence similar to the energy diffusion time.

79 ASTRONOMY AND ASTROPHYSICS↗

EURADOS INTERCOMPARISON ON MEASUREMENTS AND MONTE CARLO MODELLING FOR THE ASSESSMENT OF AMERICIUM IN A USTUR LEG PHANTOM

United States Transuranium and Uranium Registries (USTUR) Case 0102 was the first whole-body donation to the USTUR (1979), of a worker affected by a substantial accidental 241Am intake(1). Half of this man’s skeleton, encased in tissue-quivalent plastic, provides a unique human ‘phantom’ for calibrating in vivo counting systems. In this case, the 241Am skeletal activity was measured 25 y after the intake. Approximately 82 % of the 241Am remaining in the body was found in the bones and teeth. The241Am activity concentration throughout the skeleton (in all types of bone) was fairly uniform(2). A protocol has been proposed by a group of in vivo laboratories from Europe [CIEMAT-Spain, IRSN-France and Helmholtz Zentrum Mu¨nchen (HMGU)-Germany] and Canada (HML) participating in this DOS/USTUR intercomparison. The focus areas for the study included: (1) the efficiency pattern along the leg phantom using Germanium detectors (experimental and computational), (2) the comparison of Monte Carlo (MC) results with experimental values in counting efficiency data and (3) the inflence of americium distribution in the bone material (volume or surface).

61 RADIATION PROTECTION AND DOSIMETRY↗

Guidance on the Use of Hand-Held Survey Meters for radiological Triage: Time-Dependent Detector Count Rates Corresponding to 50, 250, and 500 mSv Effective Dose for Adult Males and Adult Females

In June 2006, the Radiation Studies Branch of the Centers for Disease Control and Prevention held a workshop to explore rapid methods of facilitating radiological triage of large numbers of potentially contaminated individuals following detonation of a radiological dispersal device. Two options were discussed. The first was the use of traditional gamma cameras in nuclear medicine departments operated as makeshift wholebody counters. Guidance on this approach is currently available from the CDC. This approach would be feasible if a manageable number of individuals were involved, transportation to the relevant hospitals was quickly provided, and the medical staff at each facility had been previously trained in this non-traditional use of their radiopharmaceutical imaging devices. If, however, substantially larger numbers of individuals (100 s to 1,000 s) needed radiological screening, other options must be given to first responders, first receivers, and health physicists providing medical management. In this study, the second option of the workshop was investigated by the use of commercially available portable survey meters (either NaI or GM based) for assessing potential ranges of effective dose (G50, 50Y250, 250Y500, and 9500 mSv). Two hybrid computational phantoms were used to model an adult male and an adult female subject internally contaminated with 241Am, 60Cs, 137Cs, 131I, or 192Ir following an acute inhalation or ingestion intake. As a function of time following the exposure, the net count rates corresponding to committed effective doses of 50, 250, and 500 mSv were estimated via Monte Carlo radiation transport simulation for each of four different detector types, positions, and screening distances. Measured net count rates can be compared to these values, and an assignment of one of four possible effective dose ranges could be made. The method implicitly assumes that all external contamination has been removed prior to screening and that the measurements be conducted in a low background, and possibly mobile, facility positioned at the triage location. Net count rate data are provided in both tabular and graphical format within a series of eight handbooks available at the CDC website (http://www.bt.cdc.gov/radiation/clinicians/evaluation).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Search for a Standard Model Higgs Boson in the Channel $VH\to VWW$ with Leptons and Hadronic $\tau$ in the Full CDF Run II Data Set

We present the results of the CDF search for a Standard Model Higgs boson decaying into a pair of W bosons with electrons, muons and hadronically decaying taus in the final state. In particular, we investigate a channel with three objects, two leptons and a tau. In 9.7 fb -1 of data we expect 40.0 ± 5.4 background events and 0.54 ± 0.05 signal events for a Higgs mass hypothesis of 160 GeV/c 2 , whereas in data we count 28 events. We set a 95% C.L. upper limit on σ/σSM of 12.6 for a Higgs mass hypothesis of 160 GeV/c 2 . The expected 95% C.L. upper limit for the same mass is 12.4. Results for other ninete 0 GeV/c2 to 200 GeV/c 2 are also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The QWeak Experiment's Main Detector System

The QWeak experiment will determine the weak charge of the proton Qpw to 4\% accuracy by measuring the parity violating electron scattering asymmetry from a liquid Hydrogen target at a fixed Q2. The Standard Model makes a precise prediction of the value of Qpw, and as such makes it sensitive to new physics. QWeak's main detector subsystem is comprised of eight identical 2 m long quartz bar \^{C}erenkov detectors that can operate in both integrating and counting configurations, depending on the task at hand. Where integrated detector yields are required to measure asymmetries, counting mode data acquisition is required in order to properly characterize detector performance as well as accurately measure momentum Q2. A summary and status review of the main detectors will be discussed for each running mode.

MacEwan, Scott↗

Left ventricular ejection fraction determined with the simulation of a very low-dose CZT-SPECT protocol and an additional count-calibration on planar radionuclide angiographic data

Purpose: To determine whether the left ventricular ejection fractions (EFs), measured on a high-sensitivity CZT single photon emission computed tomography (SPECT)-camera with a 70% reduction in recording times and a prevention of EF overestimation through an additional count-calibration, are concordant with reference EF from planar radionuclide angiography (2D-RNA). Methods: An additional 10-minute CZT-SPECT recording was performed in patients referred to 2D-RNA for cardiomyopathy (n = 23) or chemotherapy monitoring (n = 50) with an in vivo red blood cell labeling with 850 MBq {sup 99m}TcO{sub 4}{sup −}. The EF, obtained from CZT-SPECT with 100% (SPECT100) or 30% (SPECT30) projection times and with a SPECT-count calibration on the 2D-RNA counts of corresponding cavity volumes, were compared to EF from 2D-RNA. Results: Strong and equivalent relationships were documented between the EF from 2D-RNA and the calibrated EF from SPECT100 (y = 0.89x + 6.62; R{sup 2} = 0.87) and SPECT30 (y = 0.87x + 8.40; R{sup 2} = 0.85), and the mean EF from SPECT100 (54% ± 15%) and SPECT30 (53% ± 16%) were close to that from 2D-RNA (55% ± 15%). However, upward shifts in these mean values were documented in the absence of count calibration for both SPECT100 (60% ± 18%) and SPECT30 (60% ± 18%). Conclusion: Left ventricular EF may be determined on a high-sensitivity CZT-camera, a 70% reduction in injected activities, and an additional count-calibration for further enhancing the concordance with 2D-RNA values. [French] French Abstract: Objectif: Déterminer si les fractions d'éjection ventriculaire gauche (EF) mesurées sur une caméra CZT SPECT à haute sensibilité avec une réduction de 70% des temps d'enregistrement et une prévention de la surestimation de l'EF grâce à un étalonnage supplémentaire des coups concordent avec les EF de référence obtenues par angiographie scintigraphique planaire (2D-RNA). Méthodes: Un enregistrement CZT-SPECT supplémentaire de 10 minutes a été réalisé chez les patients référés pour évaluation de cardiomyopathie (n=23) ou suivi de chimiothérapie (n = 50) par angiographie scintigraphique planaire (2D-RNA) au globules rouges marqués avec 850 MBq 99mTcO4-. Les EF, obtenues au moyen d’une caméra CZT-SPECT avec 100% (SPECT100) ou 30% (SPECT30) de temps d’acquisition et avec étalonnage des coups SPECT sur les images 2D-RNA des volumes de cavité correspondants ont été comparés aux EF à partir de 2D-RNA. Résultats: une corrélation significative existe entre les EF obtenues par 2D-RNA et les EF étalonnées obtenues par SPECT100 (y = 0,89x + 6,62; R2 = 0,87) et SPECT30 (y = 0,87x + 8,40; R2 = 0,85). Les EF moyennes de SPECT100 (54 ± 15%) et SPECT30 (53 ± 16%) sont similaires à celles obtenues par 2D-RNA (55 ± 15%). En l'absence d'étalonnage de comptage des études SPECT100 (60 ± 18%) et SPECT30 (60 ± 18%), ces valeurs moyennes d’EF sont généralement plus élevées. Conclusion: La fonction ventriculaire gauche peut être déterminée avec une caméra CZT à haute sensibilité, une réduction des activités injectées et un étalonnage supplémentaire des coups pour améliorer la concordance avec les valeurs obtenues par 2D-RNA. [Spanish] Spanish Abstract: Propósito: Determinar si la fracción de eyección del ventrículo izquierdo, medida con la cámara CZT-SPECT con una reducción del 70% en tiempo de grabación y con la prevención de la sobreestimación mediante una calibración de cuentas adicional, que sea concordante con el valor referencia de fracción de eyección mediante radiografía planar de radionucleidos. (2D-RNA). Métodos: Una grabación adicional de 10 minutos con CZT-SPECT se realizo en pacientes referidos a radiografía planar de radionucleidos (2D-RNA) por miocardiopatías. (n = 23) o para monitorizar las quimioterapias (n = 50) con marcaje de glóbulos rojos con 850 MBq 99m TcO4. La fracción de eyección obtenida por CZT-SPECT con 100% (SPECT100) o 30% (SPECT30) de tiempo de proyección, y con SPECT con calibración de cuentas con el 2D-RNA, los volúmenes de cavidades fueron comparados con fracción de eyección . Relaciones fuertes y equivalentes fueron documentados entre fracción de eyección del 2D-RNA, y la forma calibrada de la fracción de eyección SPECT100 (y = 0.89x + 6.62; R2 = 0.87) y SPECT30 y = 0.87x + 8.40; R2 = 0.85), y la media de fracción de eyección de SPECT100 (54 ± 15%) and SPECT30 (53 ± 16%) fueron cercanos a la de el 2D-RNA (55 ± 15%). Aunque, aumentos en estas medias se documentaron en la ausencia de la calibración de cuentas para SPECT100 (60 ± 18%) y SPECT30 (60 ± 18%). Conclusión: La fracción de eyección del ventrículo izquierdo puede ser determinada con una cámara CZT de alta sensibilidad, una reducción del 70% en actividades inyectadas y la calibración de cuentas adicional para realzar la concordancia con los valores de 2D-RNA. [Chinese] Chinese Abstract: 目的: 以平面放射性核素血管造影 (2D-RNA) 测定左心室射血分数 (EF) 作为参考标准,为确定利用高灵敏度 CZT SPECT 相机在减少 70% 的记录时间, 并结合计数校准防止高估情况下测量的 EF值, 是否与 2D-RNA 测得的 EF 值一致。 方法: 对心肌病 (n = 23) 或化疗监测 (n = 50) 的患者采用体内标记法注射 850 MBq {sup 99m}TcO{sub 4} 标记的红细胞进行 2D-RNA ,随后再采集 10 分钟 CZT-SPECT。 对 CZT-SPECT 100% 投影时间 (SPECT100) 或 30% 投影时间 (SPECT30) 获得的图像进行重建, 并进行计数校准 (对相应容积获得的 2D-RNA 计数通过 SPECT 校准)获得 EF 值, 与 2D-RNA 测定的 EF 的进行比较。 结果: 2D-RNA 测定的 EF 值与 SPECT100 校准后测定的 EF 值 (y = 0.89x + 6.62; R{sup 2} = 0.87) 及 SPECT30 (y = 0.87x + 8.40; R{sup 2} = 0.85) 校准后 EF 值具有高度相关性, 并且 SPECT100 (54 ± 15%) 和 SPECT30 (53 ± 16%) 测定的 EF 平均值与 2D-RNA 测定的 EF 平均值 (55 ± 15%) 非常接近。 但是, 在没有计数校准的情况下, SPECT100 (60 ± 18%) 和 SPECT30 (60 ± 18%) 测定的 EF 平均值会被高估。 结论: 高灵敏度 CZT 相机可在减少 70% 的注射剂量情况下测定左心室 EF 值, 结合计数校准可进一步提高与 2D-RNA测得的 EF 值的一致性。 关键词: 放射性核素血管造影; 血池 SPECT; CZT 相机; 左心室射血分数; 校准曲线。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hyper Spectral Anomaly Detection

The HSA is a statistics based anomaly detection model. The model performs unsupervised anomaly detection, based on a datapoint's density and similarity within a dataset. Density and similarity data are encoded into an affinity matrix. The affinity matrix is evolved to summarize the data's structure on greater topographical scales within the data's function space. The set of evolved affinity matrices and an anomaly score vector are passed to a user defined penalized objective function. The penalized objective function of anomaly scores is then minimized. Data points where the absolute value of the z-scores of anomaly scores greater than a specified threshold are predicted as anomalies. A novel multi-filter feature has also been implemented. To reduce false positive rates, the multi-filter records the indexes of the HSA predictions. A new dataset and data loader are instantiated consisting of all the initial HSA predictions and non-anomalous data points in a 10% and 90% split respectively. The HSA is then run through this data set and a count of number of times a data point is predicted is kept. In this way the initial predictions may be compared with data spanning the entire dataset. After the multi-filter is complete, all datapoints will have an associated anomaly score, as well as a multi-filter prediction count to further filter the anomalous predictions.

Rogers, DempseyD [Idaho National Laboratory (INL),↗

Improving Detection of Disease Re-emergence Using a Web-Based Tool (RED Alert): Design and Case Analysis Study

Background: Currently, the identification of infectious disease re-emergence is performed without describing specific quantitative criteria that can be used to identify re-emergence events consistently. This practice may lead to ineffective mitigation. In addition, identification of factors contributing to local disease re-emergence and assessment of global disease re-emergence require access to data about disease incidence and a large number of factors at the local level for the entire world. This paper presents Re-emerging Disease Alert (RED Alert), a web-based tool designed to help public health officials detect and understand infectious disease re-emergence. Objective: Our objective is to bring together a variety of disease-related data and analytics needed to help public health analysts answer the following 3 primary questions for detecting and understanding disease re-emergence: Is there a potential disease re-emergence at the local (country) level? What are the potential contributing factors for this re-emergence? Is there a potential for global re-emergence? Methods: We collected and cleaned disease-related data (eg, case counts, vaccination rates, and indicators related to disease transmission) from several data sources including the World Health Organization (WHO), Pan American Health Organization (PAHO), World Bank, and Gideon. We combined these data with machine learning and visual analytics into a tool called RED Alert to detect re-emergence for the following 4 diseases: measles, cholera, dengue, and yellow fever. We evaluated the performance of the machine learning models for re-emergence detection and reviewed the output of the tool through a number of case studies. Results: Our supervised learning models were able to identify 82%-90% of the local re-emergence events, although with 18%-31% (except 46% for dengue) false positives. This is consistent with our goal of identifying all possible re-emergences while allowing some false positives. The review of the web-based tool through case studies showed that local re-emergence detection was possible and that the tool provided actionable information about potential factors contributing to the local disease re-emergence and trends in global disease re-emergence. Conclusions: To the best of our knowledge, this is the first tool that focuses specifically on disease re-emergence and addresses the important challenges mentioned above.

60 APPLIED LIFE SCIENCES↗

TagDigger: user-friendly extraction of read counts from GBS and RAD-seq data

In genotyping-by-sequencing (GBS) and restriction site-associated DNA sequencing (RAD-seq), read depth is important for assessing the quality of genotype calls and estimating allele dosage in polyploids. However, existing pipelines for GBS and RAD-seq do not provide read counts in formats that are both accurate and easy to access. Additionally, although existing pipelines allow previously-mined SNPs to be genotyped on new samples, they do not allow the user to manually specify a subset of loci to examine. Pipelines that do not use a reference genome assign arbitrary names to SNPs, making meta-analysis across projects difficult. We created the software TagDigger, which includes three programs for analyzing GBS and RAD-seq data. The first script, tagdigger_interactive.py, rapidly extracts read counts and genotypes from FASTQ files using user supplied sets of barcodes and tags. Input and output is in CSV format so that it can be opened by spreadsheet software. Tag sequences can also be imported from the Stacks, TASSEL-GBSv2, TASSEL-UNEAK, or pyRAD pipelines, and a separate file can be imported listing the names of markers to retain. A second script, tag_manager.py, consolidates marker names and sequences across multiple projects. A third script, barcode_splitter.py, assists with preparing FASTQ data for deposit in a public archive by splitting FASTQ files by barcode and generating MD5 checksums for the resulting files. TagDigger is open-source and freely available software written in Python 3. It uses a scalable, rapid search algorithm that can process over 100 million FASTQ reads per hour. TagDigger will run on a laptop with any operating system, does not consume hard drive space with intermediate files, and does not require programming skill to use.

59 BASIC BIOLOGICAL SCIENCES↗

Plutonium Basket Counter Measurement Control Q3-Q4 2023

The Plutonium Basket Counter (PBC) is a spent fuel nuclear safeguards instrument that was developed to measure spent-fuel elements from MAGNOX-type research reactors and determine their plutonium content. The instrument is designed to measure fuel elements in spent fuel cooling pools through underwater operation, but it is also able to measure radiation sources in air. The PBC determines fuel plutonium content by detecting neutrons with an array of Helium-3 detectors. The electronics make use of a JSR-15 shift register for data collection and IAEA Neutron Coincidence Counting (INCC) software for data analysis. The PBC is used to determine the 240 Pu content in spent MAGNOX fuel elements grouped into basket-like bundles, thus the instrument’s name. Reactor burnup calculations can be used in conjunction with the data from the PBC to estimate the total plutonium content in the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

R-values

I'll try to keep this short and simple. R{sub LANL} = (beta cpm of X{sub exp} on system 'A')/ (beta cpm of {sup 99}Mo{sub exp} on system 'A')/ (beta cpm of X on system 'A', from thermal on {sup 235}U)/ (beta cpm of {sup 99}Mo on system 'A', from thermal on {sup 235}U). As I understand it, the above equation is the historical (as well as current) way of determining R-values using data from beta counting at LANL. The ratio in the denominator, a little 'r', is the 'baseline' or 'calibration' value for a specific beta detector. Over time, if the detector 'drifts' one would see a variation in this 'r' during a thermal calibration measurement. This baseline is what LANL likes to track to monitor specific detector performance - this is not relevant to LLNL where gamma detection is used for determining R-values. LANL states that uncertainty is only dependent upon the count statistics for the isotopes measured. If one tries to convert this to an atom basis, the uncertainties will increase due to the incorporation of the uncertainties in the nuclear data used to convert the cpm to atoms. LLNL switched to gamma detection methods in the 1970s thus replacing our beta counting effort. The equation below is how we have since determined R-values. The numerator ratios atom values of isotopes that are determined by measuring gamma cpm (usually? using several peaks per isotope) and then converting to particle decay in dpm using detector efficiency for each peak and the appropriate branch ratio for each gamma emission. Isotope decay is then converted to atoms using specific activity, mass or volume?, and Avogadro's number. The denominator is simply the ratio of published, cumulative fission product chain yields for isotopes produced in a thermal irradiation on 235U - values of England & Ryder are used by LLNL for the NTNF program. Uncertainties in LLNL R-values are dependent upon gamma counting statistics as well as the nuclear data for each isotope. R{sub LLNL} = (Atoms of X{sub exp})/(Atoms of {sup 99}Mo{sub exp})/(Cumulative Fission Chain Yield of X, from thermal on {sup 235}U)/(Cumulative Fission Chain Yield of {sup 99}Mo, from thermal on {sup 235}U). The next page tabulates fission chain yields and 'atoms per gram' amounts measured in a recent NTNF Thermal Calibration. The R-values in the table are calculated using the LLNL method of determining R. The measure of success is demonstrated by how close to 1.00 the R-value is when determined during a Thermal Calibration. A value of 1.00 is the desired value. In the example below, only four isotopes lie outside of 1.00 by more than 3 percent. These are the four isotopic measurements that obviously need to be improved.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗